MAURY USCG vessel records Sign in
← All vessels

CENTURY LEADER NO. 3

CENTURY LEADER NO. 3 is a 1986 freight ship. The Coast Guard has recorded 79 inspections since 1986, most recently in March 2018, along with 33 deficiencies and 10 operational controls.

Records from 1986 to 2018. Most recent: inspection, 23 March 2018.

Built
1986
Last inspected
23 March 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8502468 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
268144
Flag
PANAMA
—
Maury page id
psix-268144

Inspections, by type

…with no type recorded50
Years with a record 32 calendar years (1986–2018)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it44830 - Simplified, Gross Ton
44830 - Convention (Subpart B), Gross Ton
13449 - Convention (Subpart B), Net Ton
13449 - Simplified, Net Ton
14155 - Dead Weight, Metric Ton
25986 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 79

23 March 2018 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6377131
2 February 2018 ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6348618
12 December 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6322837
21 September 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6271582
12 February 2017 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6086192
18 December 2016 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6059477
27 June 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5921217
23 February 2016 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5820454
25 January 2016 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5802382
8 August 2015 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5209497
12 June 2014 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4886272
26 February 2012 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4248334
3 January 2012 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4218364
9 August 2011 Deficiency Check · PI Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4110428
8 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4110012
8 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4110338
12 December 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 3904549
9 July 2009 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3528802
27 April 2009 Ballast Water Examination · MARPOL Annex V Examination · ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3461909
19 October 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3347345
8 September 2008 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3320199
7 August 2008 Ballast Water Examination · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3291470
8 February 2008 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3143518
30 July 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3012347
6 January 2007 Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2849403
3 January 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2849713
26 August 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2760580
24 August 2006 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2758458
3 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2560160
27 November 2005 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2540911
16 September 2005 ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2492652
14 August 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2462209
15 July 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2428067
17 April 2005 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2335641
15 December 2004 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2260198
1 November 2004 NPV Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2232627
19 July 2004 ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2136398
4 June 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2089016
27 September 2003 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1914567
25 August 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1887000
19 August 2002 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1661660
14 June 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1630926
25 April 2002 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1611132
2 August 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 292370
25 February 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 287552
21 July 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 279969
13 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 769508
6 April 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 200665
6 August 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 431487
27 March 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 52703
23 September 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 420765
29 August 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 419756
29 August 1998 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 421469
25 September 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 408202
27 September 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 395932
10 May 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 391120
5 April 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 141393
5 August 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 381429
27 June 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 380063
8 March 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 375858
8 March 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 710212
1 August 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 368978
1 August 1994 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1172041
16 March 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 365227
4 August 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 360037
5 April 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 468971
12 August 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 352671
14 April 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 501495
27 March 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 454955
6 September 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 339168
1 June 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 533429
2 December 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 334047
21 June 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 440155
20 December 1988 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 327385
1 July 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 499535
9 December 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 320235
25 August 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 512797
4 February 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 314142
2 June 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 309236

Deficiency record · 33

Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 18 December 2016 Resolved
Vessel failed to make the required 12 hour update to the vessels ETA and entered port 9 hours before the reported ETA on the vessels ANOA.
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 18 December 2016
Resolution: Vessel was issued a Letter of Warning.
Lifesaving › Lifeboat › Seating
Issued 25 January 2016 Resolved
0610; Before the ship leaves port an at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. Maintenance, testing and inspection of life-saving appliances shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring reliability of such appliances. See Narrative.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 February 2016
Resolved 23 February 2016
Resolution: Corrected to the satisfaction of the attending Classification Representative.
Operations/Management › Ballast Water Managment › Sediments
Issued 25 January 2016 Resolved
2510; Vessel must maintain a Bio-Fouling plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel does not have Bio-fouling management plan on board. 33 CFR 151.2050(g), IMO RES., 207(62), 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 February 2016
Resolved 23 February 2016
Resolution: Corrected to the satisfaction of the attending Classification Representative.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 January 2016 Resolved
2120; Every ship of 400GT an above shall carry a Garbage Management Plan which the crew shall follow. Each discharge into the sea or to a reception facility or a completed incineration shall be recorded tin the garbage record book. Vessel has a Garbage Management Plan that is not being followed by no recording the correct codes in the garbage record book, MAPOL 73/78 Annex V, Reg., 10.3.1, 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 February 2016
Resolved 23 February 2016
Resolution: Corrected to the satisfaction of the attending Classification Representative.
Documentation › Logs/Records › Oil Record Book
Issued 25 January 2016 Resolved
1710; Every ship of 400GT an above shall be provided with an Oil Record Book part 1. Each operation of this regulation shall be fully recorded so that all entries in the book appropriate to that operation are completed. The oil Record Book are missing dates and signatures and manual transfer were not recorded, MARPOL 73/78 Annex 1, REG., 17, 40AC.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 February 2016
Resolved 23 February 2016
Resolution: Corrected to the satisfaction of the attending Classification Representative.
Construction/Loadline › Hull › Transverse Frame
Issued 12 June 2014 Resolved
0981-After any survey of the ship under regulations 7,8,9, or 10 of this chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey without sanction of the administration. The follow cracks were found during the examination. Continued in narratative Act#4886272 - 74SOLAS I/11 (40ac)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2014
Resolved 1 July 2014
Resolution: Addressed and or corrected to the satisfaction of the attending Classification Society.
Lifesaving › Lifeboat Equipment › Sea-anchor
Issued 12 June 2014 Resolved
0611;The normal equipment of every lifeboat shall consist of:(vi)a mast or masts, with galvanized wire stays together with sails,(ix)A sea-anchor of approved size,(xxiii)a suitable locker for stowage of equipment items. Locker unsuitable to carry all small items in both lifeboats, Sea-anchor is missing on starboard, and sailing equipment is incomplete on port lifeboat, 74SOLAS (81) III/11 (a) 40ac
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2014
Resolved 1 July 2014
Resolution: Addressed and or corrected to the satisfaction of the attending Classification Society.
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 12 June 2014 Resolved
0680; Suitable arrangements shall be made for embarkation into the lifeboats. All four ladders provided at lifeboat arrangements are at least two meters short and unsuitable for embarkation, 74SOLAS (81) III/19 (a) - (40ac).
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2014
Resolved 1 July 2014
Resolution: Addressed and or corrected to the satisfaction of the attending Classification Society.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 12 June 2014 Resolved
2120; Vessel must maintain a Ballast Water Management Plan developed specifically for the vessel, including Bio-Fouling. Vessel does not have Bio-Fouling implemented on-board and crew unfamiliar, 33CFR 151.2050 (g), Ref. MEPC 207 (62) (10c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 12 June 2014
Resolution: Crew was provided instruction on implementation of a Bio-Fouling Plan and given a sample Bio-Fouling Plan to use as guidance.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 June 2014 Resolved
2120; Every ship of 100 GT and above shall carry a Garbage Management Plan which the crew shall follow. Procedures for disposal of Garbage, collection listing containers not being completed or followed onboard Vessel's Garbage Management Plan by crew members, MARPOL V/ 9.2 (10c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 12 June 2014
Resolution: Crew was instructed on implementation of Garbage Management Plan and given guidance to be in compliance with Vessel''''''''s Garbage Management Plan.
Documentation › Logs/Records › Oil Record Book
Issued 12 June 2014 Resolved
1710; Every ship 400 GT and above shall be provided with an Oil Record Book. All entries shall consist of a Date, Code, Item Number, and Signed. Vessel's Oil Record Book was missing dates and signatures since 17JUL13 to present, MARPOL I/36 (10c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 12 June 2014
Resolution: Crew was given guidance on correct format for the Oil Record Book.
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 June 2014 Resolved
1705; Every ship 400 GT and above shall carry a Shipboard Oil Pollution Emergency Plan. The plan shall be prepared, and shall have a list of Authorities to be contacted in case of Emergency. Vessel has incorrect Local Contacts as per Section 2.3.2 and Appendix 3 of the SOPEP. MARPOL I/ 37.2.4 (10c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 12 June 2014
Resolution: Crew/Vessel was provided proper documentation on implementation of correct Local Contacts for the Vessel''''''''s SOPEP plan.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 12 June 2014 Resolved
2535; he company and ship shall comply with the requirements of the International Safety Management Code. The crew fail to exhibit knowledge about lifeboat procedures, fuel change-over procedures, and emergency steering operations. SOLAS 74 (09) cons, IX/ 3.1 and ISM Code Part A.7 (10c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 12 June 2014
Resolution: Gave Master/Crew guidance on improving procedures for lifeboat procedures, fuel change-over procedures, and emergency steering operations.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 12 June 2014 Resolved
0799; Suitable instructions and components spare for testing and maintenance shall be provided. Vessel is using open flame to test heat and flame detectors, 74 SOLAS (81) 11-2/ 13.1.1.2 (40a,c).
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 June 2014
Resolved 1 July 2014
Resolution: Addressed and or corrected to the satisfaction of the attending Classification Society.
Engineering › Diesel Engine (propulsion-electric) › Pump, High Pressure (fuel injection)
Issued 27 April 2009 Resolved
0750 GENERATOR #1 & #2 DRAIN LINE FROM COFFER DAM IS NOT OF AN APPROVED TYPE (RUBBER HOSE). CLASS TO ATTEST TO REPLACEMENT AND PROPER REPAIR. ( SOLAS 74/78 CH. II-2/51(g) )
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 9 July 2009
Resolution: Class report received attesting to repairs. No further action required.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 October 2008 Resolved
1530 - Radar - 3cm radar inoperable. Certified repair is needed to return unit into normal operating secifications.
Action required: 705 - Other - as specified
Due 19 November 2008
Resolved 19 November 2008
Resolution: 19OCT08: Received tech report for 3cm radar. Replaced scanner and motor brushes. Radar is now fully operational via tech report from Mackay Communications. LOD rescinded.
Engineering › Lubricating Oil Service System › Pump Prime Mover
Issued 7 August 2008 Resolved
Vessel has temporary ventilation ducting and a fan set up for cooling the number 2 lube oil service pump for the main engine, for artificial cooling of electrical motor, vessel is to provide adequate arrangements to keep the motor cool for all areas of operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 8 September 2008
Resolution: Received report from NKK that shows deficiency has been dealt with.
Engineering › Lubricating Oil Service System › Valve
Issued 7 August 2008 Resolved
Vessel has a leak on the number 2 lube oil sludge tank drain valve stem, vessel is to make permanent repairs to the satisfaction of classification society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 September 2008
Resolved 8 September 2008
Resolution: Received report from NKK that shows deficiency has been dealt with.
Operations/Management › Pollution › Control of Garbage
Issued 8 February 2008 Resolved
Mixed garbage found throughout ship. Batteries and bulbs were mixed with bottles and cans, food waste mixed with combustibles, gasket material and metal found in ash. The crew are not following procedures on their garbage management plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 8 February 2008 Resolved
Hole found on A-0 bulkhead between passage way and ship's office. Fire boundary not maintained. Crew had no information for reasons of the hole. Make necessary repairs to the satisfaction of class.
Action required: 705 - Other - as specified
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Engineering › Compressed Air System (control) › Piping
Issued 8 February 2008 Resolved
Soft patches fond on #2 compressor in AC room. The captain was not aware of the repairs made. No reports made to fix. Repairs will be made to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Lifesaving › Lifeboat › Stability
Issued 8 February 2008 Resolved
Improper equipment noted for lifeboats: Port - Sails rotten, Mast stays missing turn buckles, missing covers. Stbd - Missing covers. Make corrections to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 8 February 2008 Resolved
SOLAS training manual not ship specific. No detail found for launching lifeboats and installation of covers. Make corrections to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Construction/Loadline › Structures › Door
Issued 8 February 2008 Resolved
Structural deficiencies found: Electrical conduct box aft of of accomodation space is cracked, E.R. Damper MV20 holed; cracks found in areas around weather doors, cracks on bulkhead of engine control room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 8 February 2008 Resolved
Sewage tank wasted holed. Epoxy patches used to seal holes; unit is leaking and must be repaired to the satisfaction of class. 33 CFR 159.121(b)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Communications › Audible Communications › SPD (Other)
Issued 8 February 2008 Resolved
Audible alarms for sliding doors in E.R not operating; Manual states alarm will sound under operation. Manual M-3-37 pg. 17
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Electrical › Electric Generation Source (emergency) › Generator
Issued 8 February 2008 Resolved
Starter for Emerfency Generator has weak, grinding operation during testing; it is recommended that the unit is replaced.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Documentation › Logs/Records › Oil Record Book
Issued 8 February 2008 Resolved
Oil record book lists inaccurate amount for weekly checks compared to IOPP; sludge not authorized to be burned in incinerator and dates missing in oil record book- items incomplete on Code "D".
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 March 2008
Resolution: Corrected under the direction of the attending Classification Society Representative.
Engineering › Steering Gear System
Issued 25 August 2003 Resolved
CLEAN UP EXCESSIVE HYDRAULIC FLUID IN STEERING GEAR ROOM PRIOR TO ENTERING U.S. PORT AFTER SAILING FOREIGN.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 September 2003
Resolution: Conducted visual inspection confirming hydraulic fluid cleaned up.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 April 2002 Resolved
Issued Letter of Deviation for inop radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2002
Resolution: Rcvd fax from technician confirming repair of radar. Vsl cleared to sail.
Fire Fighting
Issued 29 August 1998 Resolved
Perform maintenance on the main discharge valve to the low pressure CO2 system to allow the remote station at the bridge to be operable. SOLAS 74 I/11. Correct to the satisfaction of class prior to next US port after sailing foreign.
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Documentation
Issued 12 August 1992 Resolved
Vessels dangerous cargo manifest did not contain the stowage location of the vehicles.
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Documentation
Issued 12 August 1992 Resolved
Vessels oil transfer procedures did not contain all the required information.
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.