MAURY USCG vessel records Sign in
← All vessels

MSC CARLA

MSC CARLA is a 1986 freight ship. The Coast Guard has recorded 40 inspections since 1986, most recently in June 2012, along with 19 deficiencies and 2 operational controls.

Records from 1986 to 2012. Most recent: operational control imposed, 15 June 2012.

Built
1986
Last inspected
15 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8419714 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
268178
Flag
PANAMA
—
Maury page id
psix-268178

Inspections, by type

…with no type recorded33
Years with a record 18 calendar years (1986–2012)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it35953 - Convention (Subpart B), Gross Ton
14861 - Convention (Subpart B), Net Ton
44442 - Dead Weight, Ton
58212 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

15 June 2012 ISPS I Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4344934
15 June 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4345106
3 January 2012 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4217783
29 December 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4215635
6 December 2010 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3905268
8 November 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3886880
17 March 2010 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3697120
29 July 2009 ISPS II Exam · Ballast Water Examination · MARPOL Annex V Examination · MARPOL Annex I Examination · PI Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3549319
27 July 2009 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3547474
17 May 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 278284
14 December 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 435866
18 June 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 429843
21 May 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 428891
7 February 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 101501
27 November 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 423086
18 July 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 393347
17 May 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 391287
23 September 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 382929
26 June 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 380060
22 December 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 477581
24 September 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 370978
24 March 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 448986
21 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 64535
26 November 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 648568
21 November 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 140439
19 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 361020
17 September 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 649763
12 March 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 649764
11 March 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 494691
19 August 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 352732
20 May 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 440353
11 May 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 495641
13 August 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 338743
14 January 1990 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 468717
16 July 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 331521
21 December 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 492724
7 July 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 324323
6 January 1988 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 507504
7 July 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 317184
2 June 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 309479

Deficiency record · 19

Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 29 December 2011 Resolved
1020- All required fire detection systems shall be capable of automatically indicating the presence of fire. Smoke sensors in purifier room were not capable of being activated during test. 74 SOLAS CH II-2 REG 13 (i)
Action required: 705 - Other - as specified
Due 5 January 2012
Resolved 4 January 2012
Resolution: Sector Charleston Port State Control Officer attended the vessel and tested each smoke detector in the purifier room with no issues. Fire alarm sounded for each detector as required.
Construction/Loadline › Hull › Hull Plating
Issued 8 November 2010 Resolved
The Vessels hull is inset on the Starboard side stern. The inset is at the top of the void space beneath the steering gear room and approximately 2" from the stern weld. Class to attest to proper repairs. ILLC 66 Annex I/1 70a. Rectify deficiency Prior to next U.S. port after sailing foreign to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 December 2010
Resolution: Received class report attesting to the following: Void space starboard aft tank (FR A-F-01) (below steering gear room). Indent noted 1m below top of tank, 0.5m from stern transom. All internal strength members not affected.
Accommodation/Occupational Safety › Ventilation › General
Issued 17 March 2010 Resolved
In the steering gear flat there is a chemical storage space. This chemical storage space had excessive fumes, as well as recent paint which has still not dried. The space lacks adequate ventilation. Rectify condition to the satisfaction of class prior to the next US port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 April 2010
Resolution: USCG deficiency 0510-Chemical storage space issued 2010-03-17 has been suitably brought in order. Chemical storage racks moved to adjacent steering gear flat which is provided with working mechanical ventilation.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 July 2009 Resolved
A-class fire door leading into carpenter shop is not smoke tight (holes around lock cylinder/thru door). Correct the same.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 6 September 2009
Resolution: After receiving confirmation (class report from DNV Job ID#59090234-1) that defs issued on 29JUL09 by USCG Sector NY (activity# 3549319) was corrected, cleared the same. Review inspection results for further details. No deficiencies remain. [name withheld]
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 July 2009 Resolved
Full acetylene tanks located on portside main deck is not secured via proper stowage racks but held by loose slings. Correct the same.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 6 September 2009
Resolution: After receiving confirmation (class report from DNV Job ID#59090234-1) that defs issued on 29JUL09 by USCG Sector NY (activity# 3549319) was corrected, cleared the same. Review inspection results for further details. No deficiencies remain. [name withheld]
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 29 July 2009 Resolved
Fixed liferaft embarkation platform located on stbd side bow is wasted. Repair the same.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 6 September 2009
Resolution: After receiving confirmation (class report from DNV Job ID#59090234-1) that defs issued on 29JUL09 by USCG Sector NY (activity# 3549319) was corrected, cleared the same. Review inspection results for further details. No deficiencies remain. [name withheld]
Documentation › Markings/Placards › Warning Signs
Issued 29 July 2009 Resolved
Various FF (IMO) placards located on deck and engine room are weathered/worn and in need of replacement. Renew the same.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 6 September 2009
Resolution: After receiving confirmation (class report from DNV Job ID#59090234-1) that defs issued on 29JUL09 by USCG Sector NY (activity# 3549319) was corrected, cleared the same. Review inspection results for further details. No deficiencies remain. [name withheld]
Construction/Loadline › Structures › Ventilators
Issued 29 July 2009 Resolved
Ventilation duct work located in engine room (above residue tank) is severely wasted (covered up with card board) in spots and in need of renewal. Correct the same.
Action required: 705 - Other - as specified
Due 12 August 2009
Resolved 6 September 2009
Resolution: After receiving confirmation (class report from DNV Job ID#59090234-1) that defs issued on 29JUL09 by USCG Sector NY (activity# 3549319) was corrected, cleared the same. Review inspection results for further details. No deficiencies remain. [name withheld]
Engineering
Issued 21 May 1999 Resolved
Repair/replace the hole in the starting air compresor cooler for the main engine. Have class inspect and verify repairs prior to departing San Francisco Bay.
Condition: Unknown
Due 18 June 1999
Resolved 18 June 1999
Engineering
Issued 21 May 1999 Resolved
Repair/replace the #3 filter pod on the OWS and also the actuation valve isnot working properly on the resert side. Have class inspect and verify the repairs prior to departing San Francisco Bay.
Condition: Unknown
Due 24 June 1999
Resolved 24 June 1999
Lifesaving
Issued 17 May 1996 Resolved
Provide the dimensions for both the port and starboard lifeboats as required by SOLAS III, reg 41.9.1.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Fire Fighting
Issued 26 June 1995 Resolved
Make permanent repairs to firemain piping. Temp patch not holding. Leak is on discharge side of main firepump in engineroom.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Fire Fighting
Issued 26 June 1995 Resolved
Make repairs to 6 fire hoses located on main deck. The wire holding the hoses on the fittings/connects are broken/missing causing the hose to separate from the connection rendering the hoses unservicable._x001C_ _x001C_
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Lifesaving
Issued 26 June 1995 Resolved
Make STBD life raft float free. Life raft is tied down.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Engineering
Issued 26 June 1995 Resolved
Provide flame screens to fuel tank vents. No flame screens are present on any fuel tank vent.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Lifesaving
Issued 26 June 1995 Resolved
Prove operation of waterlights located on main deck. Both waterlights inoperable.
Condition: Unknown
Due 28 June 1995
Resolved 28 June 1995
Navigation
Issued 13 August 1990 Resolved
VESSELS U.S.C.G. LIGHT LIST VOL. VI. 1990ed. WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(a)(2)(ii).
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Navigation
Issued 13 August 1990 Resolved
VESSELS N.O.S. CHART 18746 WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR_x001C_ 164.33(a)(1)(ii).
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Navigation
Issued 7 July 1988 Resolved
NOS CHARTS 18740, 18749 & 18746 ON BOARD BUT NOT CURRENTLY CORRECTED AS REQUIRED BY 33 CFR 164.33(A)(1)(II). NO FOREIGN EQUIVALENTS AVAILABLE ON BOARD.
Condition: Unknown
Due 7 July 1988
Resolved 7 July 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.