ROYAL STAR

ROYAL STAR is a 1986 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in April 2026, along with 25 deficiencies — 1 with no resolution recorded — and 5 casualty investigations between 2012 and 2023.

Records from 2012 to 2026. Most recent: inspection, 6 April 2026.

Built
1986
Last inspected
6 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 April 2026
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE8229
268184
Flag
UNITED STATES
Maury page id
psix-268184

Documentation record

Registered dimensions (L × B × D)82.8 ft × 24.0 ft × 6.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPOOLE BOAT COMPANY · CHULA VISTA CA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

6 April 2026 COI Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8320631
23 February 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8314397
7 April 2025 Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8103503
7 March 2025 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8089319
2 April 2024 MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7888939
4 March 2024 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7874035
31 October 2023 Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818321
19 September 2023 In-Service Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7795224
18 September 2023 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818103
17 April 2023 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670467
21 March 2023 Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7654641
8 March 2023 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7649484
2 November 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7588345
26 April 2022 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7435613
16 March 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7413176
20 October 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7336613
12 April 2021 MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7173936
19 March 2021 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7159443
11 May 2020 COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950319
18 March 2020 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928516
5 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6831069
19 September 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821841
20 March 2019 Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6646197
21 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6545772
16 April 2018 COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6388349
14 March 2018 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6371757
19 April 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6119959
20 March 2017 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6107993
4 April 2016 COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5846791
21 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5837385

Deficiency record · 25

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 April 2026 No resolution recorded
Owner/master medical certificate expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2026 Resolved
First aid kit medication expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 7 April 2026
Resolution: New first aid medication purchased and on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2026 Resolved
CO2 fixed fire fighting system warning placard missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 7 April 2026
Resolution: Confirmed placard installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2025 Resolved
Remote fuel shutoff valve failed during testing. Repair the damaged fuel shutoff valve and demonstrate operation to the attending Coast Guard marine inspector. Cite: 46 CFR 182.455(b)(4).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 April 2025
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2025 Resolved
There was no fire detector in the wheelhouse. Install an integrated fire detector in the wheelhouse and demonstrate operation to the attending Coast Guard marine inspector. The detector must be in compliance with 46 CFR 181.450. Cite: 46 CFR 181.405(c).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 April 2025
Resolution: Witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2025 Resolved
One of the vessel's ring buoys was found to be excessively worn. Replace the affected ring buoy. To be rectified by 07 May 2025. Cite: 46 CFR 180.70.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 29 May 2025
Resolution: Ring was repalced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2024 Resolved
One of the starboard genset fuel filters has a broken flame impingement bowl installed. Replace with a manufacturer approved flame impingement bowl. To be rectified by 02 May 2024. Cite: 46 CFR 182.455
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 8 April 2024
Resolution: Received pictures of the replaced flame impingement bowl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2024 Resolved
The machinery guards are missing for the fly wheels on both MDEs. Install a machinery guard over the fly wheels to the satisfaction of the attending USCG marine inspector. To be rectified by 02 May 2024. Cite: 46 CFR 182.01-5 (Old-T).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 2 May 2024
Resolution: New guards have been fabricated and installed over the fly wheels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2023 Resolved
Vessel reported a failure of the starboard reduction gear. The failure occurred on the non-metallic vibration coupling that connects the main engine to the reduction gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2023
Resolution: Reduction gear coupling was replaced in-kind.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 21 March 2023 Resolved
Bridge Operating Station missing a interconnected smoke alarm and detection sensor. Install integrated smoke detector unit and verify satisfactory operational test.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2023
Resolution: Deficiency corrected; received picture.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 March 2023 Resolved
Aft Passenger accommodations and main deck Salon does not have secondary means of egress meeting requirements in 46 CFR 177.500. You must submit plans for approval to the U.S. Coast Guard Officer in Charge of Marine Inspection (OCMI) at the below email addressing all the listed items.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 April 2025
Resolution: Means of escape approvaed and verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2023 Resolved
01 deck portside life ring buoy light marker stowage bracket broken; replace with approved bracket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 3 April 2023
Resolution: Deficiency corrected; received picture.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2023 Resolved
Engine room switchboard indicator light covers missing; repair to the satisfaction of the attending CG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 3 April 2023
Resolution: Deficiency corrected; received picture.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021 Resolved
Variable nozzle excessive leaking during inspection. Replace in kind.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2021
Resolved 16 April 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021 Resolved
ort-side Engine room fixed fire fighting Pull Station Glass broken & signage for pull station instructions not posted. Replace glass and install pull station instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2021
Resolved 16 April 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021 Resolved
Manual circuit breaker mechanical Interlock inoperative; failed to restrict circuit breaker operation between alternate shore & Ships power. Replace or repair in kind.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 16 April 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021 Resolved
Fuel Oil transfer pump in engine room not properly mounted/secured. Re-secure.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 16 April 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 April 2021 Resolved
Excessive accumulation of oil in engine room. Remove oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2021
Resolved 16 April 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021 Resolved
Fuel supply line at STBD Main Engine not properly secured; Stand-off securing bracket to forward hose broken. Provide replacement in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 16 April 2021
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 5 January 2020
Resolved 17 October 2019
Resolution: Plans sent via email to Sector; [name withheld]
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 5 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 5 October 2019
Resolved 5 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2019
Resolution: Verified in VIVS.
Engineering › Fuel Oil Service System › Filter
Issued 16 April 2018 Resolved
Replace fuel filters on port gen-set with marine type filters and flame impingement bowls.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 17 April 2018
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2018 Resolved
Repair or replace the identified damaged life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 17 April 2018
Navigation › Piloting/Steering › Marine Charts
Issued 16 April 2018 Resolved
Provide updated navigation charts.
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 17 April 2018

Casualty record · 5

28 May 2012Routine · role: Involved in a Marine Casualty · 1 dead · activity 4327692
12 June 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4627149
11 July 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 4652592
19 September 2019Routine · role: Involved in a Marine Casualty · 1 injured · activity 6821841
18 September 2023Routine · role: Involved in a Marine Casualty · activity 7818103
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.