Records from 2012 to 2026. Most recent: inspection, 6 April 2026.
Inspection history · 30
6 April 2026
COI Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8320631
23 February 2026
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8314397
7 April 2025
Deficiency Check · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8103503
7 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8089319
2 April 2024
MTSA/ISPS Verification · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7888939
4 March 2024
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7874035
31 October 2023
Appeal
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818321
19 September 2023
In-Service Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7795224
18 September 2023
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7818103
17 April 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670467
21 March 2023
Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7654641
8 March 2023
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7649484
2 November 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7588345
26 April 2022
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7435613
16 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7413176
20 October 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7336613
12 April 2021
MTSA Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7173936
19 March 2021
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7159443
11 May 2020
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6950319
18 March 2020
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6928516
5 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6831069
19 September 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6821841
20 March 2019
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6646197
21 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6545772
16 April 2018
COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6388349
14 March 2018
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6371757
19 April 2017
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6119959
20 March 2017
Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6107993
4 April 2016
COI Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5846791
21 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5837385
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 6 April 2026
No resolution recorded
Owner/master medical certificate expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 April 2026
Resolved
First aid kit medication expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 7 April 2026
Resolution: New first aid medication purchased and on board.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 April 2026
Resolved
CO2 fixed fire fighting system warning placard missing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2026
Resolved 7 April 2026
Resolution: Confirmed placard installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2025
Resolved
Remote fuel shutoff valve failed during testing. Repair the damaged fuel shutoff valve and demonstrate operation to the attending Coast Guard marine inspector.
Cite: 46 CFR 182.455(b)(4).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 April 2025
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2025
Resolved
There was no fire detector in the wheelhouse. Install an integrated fire detector in the wheelhouse and demonstrate operation to the attending Coast Guard marine inspector. The detector must be in compliance with 46 CFR 181.450.
Cite: 46 CFR 181.405(c).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 April 2025
Resolution: Witnessed satisfactory test.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 April 2025
Resolved
One of the vessel's ring buoys was found to be excessively worn. Replace the affected ring buoy. To be rectified by 07 May 2025.
Cite: 46 CFR 180.70.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 29 May 2025
Resolution: Ring was repalced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2024
Resolved
One of the starboard genset fuel filters has a broken flame impingement bowl installed. Replace with a manufacturer approved flame impingement bowl. To be rectified by 02 May 2024.
Cite: 46 CFR 182.455
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 8 April 2024
Resolution: Received pictures of the replaced flame impingement bowl.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 April 2024
Resolved
The machinery guards are missing for the fly wheels on both MDEs. Install a machinery guard over the fly wheels to the satisfaction of the attending USCG marine inspector. To be rectified by 02 May 2024.
Cite: 46 CFR 182.01-5 (Old-T).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 2 May 2024
Resolution: New guards have been fabricated and installed over the fly wheels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 September 2023
Resolved
Vessel reported a failure of the starboard reduction gear. The failure occurred on the non-metallic vibration coupling that connects the main engine to the reduction gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 September 2023
Resolution: Reduction gear coupling was replaced in-kind.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 21 March 2023
Resolved
Bridge Operating Station missing a interconnected smoke alarm and detection sensor. Install integrated smoke
detector unit and verify satisfactory operational test.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2023
Resolution: Deficiency corrected; received picture.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 21 March 2023
Resolved
Aft Passenger accommodations and main deck Salon does not have secondary means of egress meeting requirements in 46 CFR 177.500. You must submit plans for approval to the U.S. Coast Guard Officer in Charge of Marine Inspection (OCMI) at the below email addressing all the listed items.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 April 2025
Resolution: Means of escape approvaed and verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 March 2023
Resolved
01 deck portside life ring buoy light marker stowage bracket broken; replace with approved bracket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 3 April 2023
Resolution: Deficiency corrected; received picture.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 March 2023
Resolved
Engine room switchboard indicator light covers missing;
repair to the satisfaction of the attending CG Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2023
Resolved 3 April 2023
Resolution: Deficiency corrected; received picture.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021
Resolved
Variable nozzle excessive leaking during inspection. Replace in kind.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2021
Resolved 16 April 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021
Resolved
ort-side Engine room fixed fire fighting Pull Station Glass broken & signage for pull station instructions not posted. Replace glass and install pull station instructions.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2021
Resolved 16 April 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021
Resolved
Manual circuit breaker mechanical Interlock inoperative; failed to restrict circuit breaker operation between alternate shore & Ships power. Replace or repair in kind.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 16 April 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021
Resolved
Fuel Oil transfer pump in engine room not properly mounted/secured. Re-secure.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 16 April 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 April 2021
Resolved
Excessive accumulation of oil in engine room. Remove oil from bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2021
Resolved 16 April 2021
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 12 April 2021
Resolved
Fuel supply line at STBD Main Engine not properly secured; Stand-off securing bracket to forward hose broken. Provide replacement in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2021
Resolved 16 April 2021
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, and over current protection.
Action required: 705 - Other - as specified
Due 5 January 2020
Resolved 17 October 2019
Resolution: Plans sent via email to Sector; [name withheld]
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 5 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Due 5 October 2019
Resolved 5 October 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 21 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 11 October 2019
Resolution: Verified in VIVS.
Engineering › Fuel Oil Service System › Filter
Issued 16 April 2018
Resolved
Replace fuel filters on port gen-set with marine type filters and flame impingement bowls.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 17 April 2018
Lifesaving › Lifebuoys › Serviceable
Issued 16 April 2018
Resolved
Repair or replace the identified damaged life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 17 April 2018
Navigation › Piloting/Steering › Marine Charts
Issued 16 April 2018
Resolved
Provide updated navigation charts.
Action required: 705 - Other - as specified
Due 23 April 2018
Resolved 17 April 2018