MAURY USCG vessel records Sign in
← All vessels

ANOTHER REWARD

ANOTHER REWARD is a 1986 passenger vessel (inspected). The Coast Guard has recorded 74 inspections since 1986, most recently in August 2025, along with 215 deficiencies, 2 operational controls and 1 casualty investigation in 2012.

Records from 1986 to 2025. Most recent: inspection, 25 August 2025.

Built
1986
Last inspected
25 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL7307
268185
Flag
UNITED STATES
367423860
Maury page id
psix-268185

Inspections, by type

…with no type recorded7
Years with a record 35 calendar years (1986–2025)
The 74 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.8 ft × 21.8 ft × 7.6 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · HARKERS ISLAND, NC, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 19 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7307MMSI 367423860 · active · compulsorily equipped · granted 20 August 2020, expires 20 August 2030
WDF2014MMSI 367423860 · expired · compulsorily equipped · granted 1 September 2009, cancelled 2 November 2019
WDE6856MMSI 367385770 · expired · compulsorily equipped · granted 25 November 2008, cancelled 16 February 2019
WCY7301MMSI not assigned · expired · voluntarily equipped · granted 14 October 1998, cancelled 20 December 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 74

25 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8217648
2 January 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8056818
5 December 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8035649
26 November 2024 Deficiency Check · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8040496
7 June 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7932669
7 June 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008731
30 November 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7831842
9 December 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7608500
2 November 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7588045
10 December 2021 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411660
16 December 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7112661
4 September 2020 Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7047551
12 December 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6872396
11 December 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6595543
4 December 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6591693
29 November 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6348058
6 December 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6053198
16 November 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6042083
3 September 2015 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5233976
14 August 2015 Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5216025
13 August 2015 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5222481
2 December 2010 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3902512
1 September 2010 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3838406
2 December 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3643183
3 February 2009 Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3411522
24 November 2008 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3368293
26 February 2008 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3154071
11 January 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3128246
10 January 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3127909
8 January 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3127339
10 January 2007 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2854630
6 September 2005 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2485496
2 December 2004 Annual Inspection · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2251750
21 October 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1932651
17 December 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1719749
30 October 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1698244
9 October 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1441913
21 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 189540
21 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 769434
11 September 2000 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1423439
12 October 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1122063
24 September 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1404835
18 November 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1461093
23 September 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 800176
22 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 778274
29 September 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116481
11 February 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1109054
26 November 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1359307
9 July 1996 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092977
2 July 1996 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1380564
26 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 109951
9 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 872815
9 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 876277
30 October 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184173
17 November 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840670
1 November 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 865595
25 January 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162027
7 December 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 850251
22 November 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 849261
12 November 1992 Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134754
26 November 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944857
28 October 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314381
16 August 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936254
16 August 1991 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245568
17 December 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910455
28 November 1990 Deficiency Check · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1211734
26 February 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916131
29 January 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1222618
27 February 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032950
8 February 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203831
4 March 1988 Re-Inspection · Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1336484
13 October 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017045
2 March 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314409
26 April 1986 Initial Construction-Excluding Oversight · Initial Certification · Credit Drydock
Physical examination · THE UNKNOWN UNIT · Activity 990490

Deficiency record · 215

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 2 September 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel radiotelephony certificate has incorrect call sign.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: Certificate updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2025 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering hoses are worn/degrading and required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: Hoses replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 September 2025 Resolved
A hatch exposed to the weather must be watertight. Hatch gasket for the aft rudder space is partially missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: gasket replaced.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 2 September 2025 Resolved
As appropriate for the intended voyage,all vessels must carry adequate and up-to-date-(a) Charts;. Vessel electronic charts have not been updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: charts updated.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 September 2025 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Fuel shut off valves are missing directions for operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 8 October 2025
Resolution: Proper instruction for fuel shut off valves installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are not permitted. Wing nuts found on multiple battery terminals
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: wing nuts removed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 2 September 2025 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Starboard main diesel is missing protective cover on belts at the fwd of engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: guards installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025 Resolved
Electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Electrical junction box on the outboard of port mde is missing cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: junction box removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 August 2025 Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. Fuel filter for the Port MDE, has plastic drain plug that needs to be replaced with metal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: Plastic drain plug replaced with metal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 January 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel failed to complete drydock exam by the required time. Vessel is restricted from carrying passengers until completing drydock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2025
Resolved 10 January 2025
Resolution: DD/ISE completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Records do not indicate the person conducting the inspection and do not indicate what extinguisher was inspected.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: Monthly inspections are being completed and logged.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 5 December 2024 Resolved
The master or person in charge of a ship... shall ensure that one or more garbage placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers... Vessel is not equipped with garbage placards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: New placards installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 December 2024 Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The following non-conformities were identified: 1) All engine belts on engines were found loose 2) Breaker panel on bridge and engine room missing blanks 3) Starboard generator cooling pipe leaking 4) Starboard reduction gear leaking oil 46 CFR 182.01-5(a) OLD T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: All repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 December 2024 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. All bilge strainers have the same area as the suction pipe. 46 CFR 182.25-5(b) OLD T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: All bilge suction strainers replaced with metal of proper size.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2024 Resolved
Batteries... shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Battery by port generator not protected. 46 CFR 183.05-20 OLD T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: Plastic box used to cover batteries
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2024 Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. Two sea water inlet pipes with flexible hose connections are not equipped with double hose clamps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: Double hose clamps installed
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 December 2024 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Installed compass has no light.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 December 2024
Resolution: Replaced compass with a new compass that had a light installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 December 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Retroreflective material on most life jackets worn and no longer serviceable.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: New SOLAS tape installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 November 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port side reduction gear experienced a failure of the drive plate.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2024
Resolution: Replaced drive plate with new.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 June 2024 Resolved
Vessel was boarded by FWC operating outside of its approved route.
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 5 March 2025
Resolution: Closed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2024 Resolved
Violation of Law/ Regulation by credentialed mariner by operating outside of the scope of the COI. Vessel was found outside of 3nm by FWC.
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 5 March 2025
Resolution: Closed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2023 Resolved
In addition to the other requirements of this section, 46 CFR 147.60 and 147.65 of this chapter require that -Carbon dioxide cylinders of all portable, semi portable, and fixed systems be tested and marked. - NOTE - Section 147.65 of this chapter includes a requirement that the cylinder must be retested and re-marked. Cylinders retested under any of the above conditions shall have new or renewed valve and safety relief devices of the proper design installed in the cylinder. 46 CFR 176.25-25(c)(1) Provide documentation of 12 year hydrostatic testing and servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2023
Resolved 8 December 2023
Resolution: fixed FF
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2023 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. 46 CFR 180.25-5(a) Vessel is limited to carriage of 70 passengers until total number of life preservers is in compliance with the SECTOR MIAMI issued Certificate of Inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 30 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2022 Resolved
Fix all fuel leaks created from disassembly in the dry dock
Action required: 705 - Other - as specified
Due 3 January 2023
Resolved 16 December 2022
Resolution: All fuel leaks were addressed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2022 Resolved
Replace the worn shaft support bearings port and stbd.
Action required: 705 - Other - as specified
Due 3 January 2023
Resolved 16 December 2022
Resolution: All worn bearings were replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2022 Resolved
Each vessel certified under 46 CFR 176 must display the Certificate of Inspection on boar the vessel at all times. The certificate was not on board the vessel for inspection and according to the operator it was lost. Previous inspections with the same results of a lost COI resulted in the issuance of this prior to carrying passengers deficiency. 46 CFR 176.01-45
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 September 2020 Resolved
Found first aid kit with missing contents and expired equipment. Provide first aid kit with contents meeting 160.041 Q specs.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Verified purchase of new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 September 2020 Resolved
Provide current updated navigational charts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Verified purchase of new updated navigational chart.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2020 Resolved
The grab lines on the ring buoy are deteriorated. Replace grab lines on ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Witnessed install of renewed grab lines on ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2020 Resolved
Missing 17 Adult L/J. 20 Adult L/J need proper SOLAS reflective tape and proper marking. Provide the appropriate number of life jackets as stated on the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Observed life jackets with proper marking and replaced retroreflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2020 Resolved
Provide appropriate life jacket donning instructions and ensure instructions are properly posted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Posted appropriate life jacket donning instructions.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2020 Resolved
Install a pressure gauge on the outlet side of the fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Pressure gauge on fire pump installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2020 Resolved
Port side service generator is in process of installation. Provide proof of proper operation of service generator after completed installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Conducted satisfactory test of generator.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 September 2020 Resolved
Vessel not meeting minimum manning requirements. Operator instructed to meet the manning requirements of their COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Conducted satisfactory MOB drill with newly installed jacob's ladder and pulley system.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 12 December 2019 Resolved
FCC Station License and Bridge to Bridge certificates were both expired. Certified technician to conduct necessary inspections and certificates to be obtained.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: CLosed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2019 Resolved
Dead end wiring found on main deck, upper deck (junction boxes), in engine compartment by stbd eng, and in tank room. Remove all dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2019
Resolution: All dead end wiring was removed from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 December 2019 Resolved
Bilge piping leading to pump on stbd engine had a pin hole leak at the elbow. Repair leak.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: CLosed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 December 2019 Resolved
Original COI was not on board. COI shall be kept on board at all times.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2019
Resolution: COI was placed on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 December 2018 Resolved
two overboard discharge valves (gate valves) found to be wasted and need to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2018
Resolution: both valves replaced with new gate valves.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2018 Resolved
both breaker box's in wheel house missing covers and are creating a shock hazard. Replace covers.
Due 4 December 2018
Resolved 4 December 2018
Resolution: both covers were found on board and placed back in service.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 November 2016 Resolved
A visual indicator must be provided at the operating station. Visual indicator for engine compartment not working. Fix indicator light. 46 CFR 182.530(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2016
Resolution: attending marine inspector tested bilge alarm lights and all functioned properly.
Lifesaving › Lifebuoys › Size
Issued 16 November 2016 Resolved
Ring buoys on Coastwise routes must be orange and 24 inches in diameter. Ring buoy on board is white and 20 inches. Replace with proper type and properly mark.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 16 November 2016 Resolved
A waste management plan shall be in place for the vessel. No waste management plan in place for the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 16 November 2016
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 3 September 2015 Resolved
Provide watertight covers for E/R outlets and switches
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 September 2015 Resolved
Provide a cover for the generator batteries
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 September 2015 Resolved
Renew batteries in all floating lights prior to operating at night
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Construction/Loadline › Structures › Door
Issued 3 September 2015 Resolved
Renew watertight door gasket for E/R watertight door
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Documentation › Certificates/Documents › Stability Letter
Issued 3 September 2015 Resolved
Post COI and Stability Letter
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 3 September 2015 Resolved
Provide updated copy of Nav Rules
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 10 September 2015
Engineering › Diesel Engine (propulsion-direct drive) › Piston
Issued 14 August 2015 Resolved
Provide repair proposal for STBD engine. Upon repair approval and completion of repairs conduct sea trials with marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2015
Construction/Loadline › Structures › Deck Plating
Issued 8 December 2010 Resolved
Make repairs to rotted ply wood deck IAW repair proposal.
Action required: 705 - Other - as specified
Resolved 30 July 2011
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 December 2010 Resolved
Replace shaft bearings; >50% wasted (4)
Action required: 705 - Other - as specified
Resolved 8 December 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 December 2010 Resolved
Remove or properly dead-end wires in forepeak, lazarette, and overhead aft deck. 46 CFR 183.05-50
Action required: 705 - Other - as specified
Resolved 8 December 2010
Construction/Loadline › Hull › Side Shell
Issued 2 December 2010 Resolved
Crop and renew wasted plank forward stbd side chine. Provide a repair plan. NVIC 7-95
Action required: 705 - Other - as specified
Resolved 8 December 2010
Construction/Loadline › Hull › Hull Plating
Issued 2 December 2010 Resolved
Crop and renew wasted plank midship STBD side chine. Provide repair plan. NVIC 7-95
Action required: 705 - Other - as specified
Resolved 8 December 2010
Construction/Loadline › Structures › Superstructure
Issued 2 December 2010 Resolved
Provide repair proposal for wasted upper deck, port aft.
Action required: 705 - Other - as specified
Resolved 6 December 2010
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 September 2010 Resolved
Provide most recent Coast Guard Light List.
Due 15 September 2010
Resolved 15 September 2010
Resolution: CG Light List provided on vessel
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 1 September 2010 Resolved
Provide latest Coast Guard Tidal Current Tables.
Due 15 September 2010
Resolved 15 September 2010
Resolution: CG Tidal Tables provided on vessel.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 September 2010 Resolved
Provide copy of 72 COLREGS.
Due 15 September 2010
Resolved 15 September 2010
Resolution: 72 COLREGS provided on vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2010 Resolved
Properly terminate wires IWO battery box, aft engineroom port side and remove water from battery box.
Due 15 September 2010
Resolved 15 September 2010
Resolution: Wires terminated from battery box, water removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 September 2010 Resolved
Make permanent repair WRT wire cap for starter on port main engine.
Due 15 September 2010
Resolved 15 September 2010
Resolution: Wire cap removed and repairs made IWO attaching wires to permanent connection.
Engineering › Bilge Water Management System › Pump
Issued 1 September 2010 Resolved
Provide sufficient length suction hose for hand operated fire/bilge pump.
Due 15 September 2010
Resolved 15 September 2010
Resolution: Hose for hand operated fire/bilge pump provided.
Engineering › Fuel Oil Service System › Valve, Control
Issued 1 September 2010 Resolved
Repair reach rods for both emergency fuel shut-offs.
Due 15 September 2010
Resolved 22 September 2010
Resolution: Reach rods repairs and proper operation prooven.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 December 2009 Resolved
Replace 7 missing Type 1 adult lifejackets.
Action required: 705 - Other - as specified
Due 2 December 2009
Resolved 3 December 2009
Communications › Public Address System › Loudspeaker
Issued 2 December 2009 Resolved
Replace missing port forward PA speaker.
Action required: 705 - Other - as specified
Due 16 December 2009
Resolved 3 December 2009
Communications › Public Address System › Loudspeaker
Issued 2 December 2009 Resolved
Repair starboard side forward PA speaker.
Action required: 705 - Other - as specified
Due 16 December 2009
Resolved 3 December 2009
Lifesaving › Lifefloat › Paddle
Issued 2 December 2009 Resolved
Replace one missing life float paddle.
Action required: 705 - Other - as specified
Due 16 December 2009
Resolved 3 December 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 2 December 2009 Resolved
Provide operating instructions for CO2 system.
Action required: 705 - Other - as specified
Due 16 December 2009
Resolved 3 December 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 December 2009 Resolved
Remove extension cord in galley space.
Due 16 December 2009
Resolved 2 December 2009
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Stiffener
Issued 3 February 2009 Resolved
Crop out rotten wood around steering compartment hatch IWO starboard deck longitudinal beam.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Generator (propulsion-electric) › Cable
Issued 3 February 2009 Resolved
Replace all flex exhaust hose on Port & Stbd generators in steering gear compartment.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Construction/Loadline › Hull › Hull Plating
Issued 3 February 2009 Resolved
Replace transom through hull fitting for live well with metallic fitting.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 February 2009 Resolved
Make repairs to stbd exhaust muffler leak in steering compartment.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Steering Gear System › Rudder Stock
Issued 3 February 2009 Resolved
Tighten loose bolts on stbd rudder in steering compartment.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 February 2009 Resolved
Crop out rotten wood on longitudinal stbd side of tool box in engine room.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Bilge Water Management System › Piping
Issued 3 February 2009 Resolved
Replace intake and discharge hose for bilge pump on stbd main engine.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 February 2009 Resolved
Replace lagging on exhaust piping on main engines.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Sea-water System (primary cooling) › Piping
Issued 3 February 2009 Resolved
Replace seal on port side raw water intake.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 February 2009 Resolved
Crop out rotten wood in sewage compartment, aft bulkhead stbd side.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 3 February 2009 Resolved
Make repairs to aft bulkhead in engine room IWO stbd shaft (crop out wasted wood).
Action required: 705 - Other - as specified
Resolved 10 February 2009
Engineering › Bilge Water Management System › Strainer
Issued 3 February 2009 Resolved
Remove debris under tool box in engine room and throughout bilges.
Action required: 705 - Other - as specified
Resolved 24 February 2009
Construction/Loadline › Hull › Side Shell
Issued 3 February 2009 Resolved
Make proper repairs to hull as indicated at stem of vessel.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Stability › Weathertight Integrity › General
Issued 3 February 2009 Resolved
Complete deficiencies from previous annual inspection dated 11/24/2009.
Action required: 705 - Other - as specified
Resolved 10 February 2009
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 November 2008 Resolved
Prove proper operation of smoke detector on bridge.
Due 3 December 2008
Resolved 3 December 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 24 November 2008 Resolved
Replace missing smoke detector in galley.
Due 3 December 2008
Resolved 3 December 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 November 2008 Resolved
Replace oxidized Port and Stbd running lights.
Due 3 December 2008
Resolved 3 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 November 2008 Resolved
Remove or properly terminate dead end wires under operating station and engine room.
Due 3 December 2008
Resolved 3 December 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 November 2008 Resolved
Replace cover for breaker box stbd side engine room, foward bulkhead.
Due 3 December 2008
Resolved 3 December 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 24 November 2008 Resolved
Replace outlet cover in galley stbd side.
Due 3 December 2008
Resolved 3 December 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 November 2008 Resolved
Replace hose clamp on stbd side sxhaust piping in fuel compartment.
Due 3 December 2008
Resolved 3 December 2008
Documentation › Certificates/Documents › FCC SSL
Issued 24 November 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 3 December 2008
Construction/Loadline › Structures › Superstructure
Issued 24 November 2008 Resolved
The A/C units in the superstructure bulkhead have been removed and are being replaced. Properly repair superstructure bulkheads to aproved structural standards or replace a/c units. Prior to credit dry-dock.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 10 February 2009
Stability › Weathertight Integrity › General
Issued 24 November 2008 Resolved
Replace cracked window in pilot house. Prior to credit dry-dock.
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 24 February 2009
Fire Fighting › Fire Pumps › Pressure
Issued 11 January 2008 Resolved
Prove proper operation of electric fire pump.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Fire Fighting › Fire Main › Valves
Issued 11 January 2008 Resolved
Install valve handle on manifold for fire main system.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 11 January 2008 Resolved
Provide operating instructions for bilge and fire main system.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 11 January 2008 Resolved
Make repairs to leaking thru-hull valve for bilge discharge.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 11 January 2008 Resolved
Install fresh water pump for potable water and sewage system.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 January 2008 Resolved
Make repairs to leaking flex hose supply line on sewage system.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 11 January 2008 Resolved
Properly secure blue tank for sewage system.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 January 2008 Resolved
Make sewage system breaker box weather tight.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 January 2008 Resolved
Doubble clamp port generator exhust hose.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Electric Generation Source (service) › Power Requirement
Issued 11 January 2008 Resolved
Provide caps for batteries in engine room.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 11 January 2008 Resolved
Replace raw water intake hose on port generator.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 January 2008 Resolved
Replace missing bolts for main diesel engine exhust support brackets.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Electrical › Lighting (service) › Outlet Box
Issued 11 January 2008 Resolved
Properly end wires in overhead main deck.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Lighting (service) › Outlet Box
Issued 11 January 2008 Resolved
Properly cover electrical outlet box IWO ladder to rod compartment.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2008 Resolved
Provide cover for light in pilot house.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2008 Resolved
Provide guards for main deck lights port & stbd sides.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 24 November 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 January 2008 Resolved
Prove proper operation of smoke detectors on main deck.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 11 January 2008 Resolved
Replace grab line on lifering bouy.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 11 January 2008 Resolved
Properly secure microwave oven.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Engineering › Bilge Water Management System › Valve
Issued 11 January 2008 Resolved
Repair or replace bilge pump valve in lazerette
Action required: 705 - Other - as specified
Resolved 18 January 2008
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 11 January 2008 Resolved
Properly repair dogging mechanism and replace gasket for lazerteet water-tight hatch.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 January 2008 Resolved
Provide origional certificate of documentation.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 11 January 2008 Resolved
Provide proof of CPR qualification.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 January 2008 Resolved
Prove proper operation of stern light.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Lifesaving › Lifefloat › Serviceable
Issued 11 January 2008 Resolved
Provide proof of serviceability of lifefloat or replace.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 January 2008 Resolved
Provide bracket for portable fire extinguisher on bridge.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2008 Resolved
Properly secure deck railing on Stbd. side, upper deck.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 10 June 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 January 2008 Resolved
Properly install blanks on bridge panel box.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 January 2008 Resolved
Install cover plate on electrical box in engine room port side foward.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2008 Resolved
Repair indicator lights for bilge pump bow compartment and tank compartment.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 January 2008 Resolved
Provide list of all crewmembers enrolled in drug testing program.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 January 2008 Resolved
Provide signed copy of drug testing program contract.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 January 2008 Resolved
Post EAP hotline numbers.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 January 2008 Resolved
Provide alcohol testing devices.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 11 January 2008 Resolved
Label breaker box in engine room.
Action required: 705 - Other - as specified
Resolved 18 January 2008
Electrical › Electric Supply System (service) › Cable
Issued 11 January 2008 Resolved
Repair indicator light for water tight door in engine room.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 26 February 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2008 Resolved
Vessel is restricted from carrying passengers on the upper deck until repairs to the railing is completed.
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 10 June 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 January 2008 Resolved
Vessel restricted from operating until annual exam has been completed. Inspectors took possession of COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 February 2008
Construction/Loadline › Hull › Keel
Issued 10 January 2007 Resolved
Provide repair proposals and make proper repairs to wasted areas of the keel, bow, cracked beams in the transom, split seams on the side shell and rotted frame member in fuel oil space.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Engineering › Bilge Water Management System › Valve
Issued 10 January 2007 Resolved
Install positive closing valves on all discharge pump lines.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Construction/Loadline › Hull › Hull Plating
Issued 10 January 2007 Resolved
Renew wasted butt block IWO stbd aft engine room.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 10 January 2007 Resolved
Renew clamps on port shaft flexible boot.
Action required: 705 - Other - as specified
Resolved 30 January 2007
Construction/Loadline › Hull › Hull Plating
Issued 10 January 2007 Resolved
Renew backing block on portside sewage tank discharge valve.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Construction/Loadline › Hull › Side Shell
Issued 10 January 2007 Resolved
Seal and arrest wood rot in stbd steering gear compartment.
Action required: 705 - Other - as specified
Resolved 26 January 2007
Engineering › Bilge Water Management System › Not Operational
Issued 10 January 2007 Resolved
Prove proper operation of bilge dewatering system.
Action required: 705 - Other - as specified
Resolved 30 January 2007
Lifesaving › Lifefloat › Serviceable
Issued 7 September 2005 Resolved
Renew/Repair 25 Man Lifefloat prior to operating beyond headlands with more then 74 persons onboard.
Action required: 705 - Other - as specified
Resolved 8 September 2005
Engineering › Steering Gear System › Rudder
Issued 7 September 2005 Resolved
Repair port rudder post leak.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 15 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 September 2005 Resolved
Provide servicing report on fixed and protable fire extinguishing systems by 30SEP05.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 15 September 2005
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 7 September 2005 Resolved
Repair Broken Handrail on Port side prior to 30 Sep 05.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 15 November 2005
Construction/Loadline › Hull › Keel
Issued 14 December 2004 Resolved
Complete hull repairs to areas marked.
Due 14 January 2005
Resolved 16 December 2004
Construction/Loadline › Penetrations › Gasket
Issued 14 December 2004 Resolved
Renew gasket at forepeak hatch.
Due 14 January 2005
Resolved 16 December 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 14 December 2004 Resolved
Tighten up hand rail at deck ladder ( bow to upper deck).
Due 14 January 2005
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2004 Resolved
Provide independent support for electrical wires in overhead. ( metal/ 24" spacing).
Due 14 January 2005
Resolved 16 December 2004
Construction/Loadline › Penetrations › Pipe Flange
Issued 14 December 2004 Resolved
Make proper penetration at aft bulkhead of PVC pipe. (metal pipe, valves on both sides)
Due 14 January 2005
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2004 Resolved
Cable splice at fresh water pump must be in an enclouser.
Due 14 January 2005
Resolved 16 December 2004
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 14 December 2004 Resolved
Provide a vent outside of space (wx deck) and remove hose being used as a sight glass from oil storage tank.
Due 14 January 2005
Resolved 16 December 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 December 2004 Resolved
Provide complete first aid kit.
Due 31 December 2004
Resolved 16 December 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 December 2004 Resolved
Remove or repair dead ended cables in engine room.
Due 31 December 2004
Resolved 16 December 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 2 December 2004 Resolved
Provide documentation of drills held.
Due 31 December 2004
Resolved 16 December 2004
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 2 December 2004 Resolved
Re-install exhaust heat coverings on all engines.
Due 31 December 2004
Resolved 16 December 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 2 December 2004 Resolved
Provide a fire service report showing the weight of bottles of CO2.
Due 31 December 2004
Resolved 14 December 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 2 December 2004 Resolved
Provide proper fire extingisher brackets at engine room
Due 31 December 2004
Resolved 14 December 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 2 December 2004 Resolved
Provide separate motor controller for fire pump.
Due 31 December 2004
Resolved 14 December 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 2 December 2004 Resolved
Provide light fixture cover on bridge.
Due 31 December 2004
Resolved 14 December 2004
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 December 2004 Resolved
Replace retro tape on lifejackets identified prior to night time operation.
Due 31 December 2004
Resolved 14 December 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 2 December 2004 Resolved
Complete repairs to bulkwork at upper deck.
Due 14 January 2005
Resolved 16 December 2004
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 October 2003 Resolved
Maintain log entries for crew training, and drills.
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 16 December 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 October 2003 Resolved
Renew light covers as need throughout vessel.
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 16 December 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 October 2003 Resolved
Marke the stowage location for the Childs Lifejackets.
Condition: Improper Installation
Due 22 November 2003
Resolved 16 December 2004
Construction/Loadline › Structures › Deck Plating
Issued 21 October 2003 Resolved
Renew wooden bulwarks IWO upper deck prior to completion of next dry-dock. Extisting bulwark is showing sign of rot. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 31 December 2004
Resolved 14 December 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 October 2003 Resolved
Renew lagging IWO of engine exhaust repairs.
Condition: Improper/Lack of Maintenance
Due 22 November 2003
Resolved 14 December 2004
Engineering › Reduction Gearing/Clutches
Issued 30 October 2002 Resolved
Renew/replace rear main oil seal. LEGACY COMPONENT DESC: Rear Main Seal
Condition: Unknown
Due 1 November 2002
Resolved 5 November 2002
Engineering › Reduction Gearing/Clutches
Issued 30 October 2002 Resolved
Properly repair marine gear oil cooler to stop water intrusion into oil sump, and stop oil emulsification. LEGACY COMPONENT DESC: Oil Cooler
Condition: Damaged By Earlier Event
Due 1 November 2002
Resolved 5 November 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, replace weak link on existing sea painter, repair waterlight on port side BA & repaint/repair canvass loops on port side BA.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, provide new retro on all BAs.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Replace/renew sign for "employees only" on fwd stairs.
Condition: Unknown
Due 23 October 2001
Resolved 30 October 2002
Electrical
Issued 9 October 2001 Resolved
Trouble shoot (starting problem) and repair stbd ship's service generator and provide report to MSO.
Condition: Unknown
Due 23 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, repair/replace retro-tape on 17 adult and 04 children lifejackets.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, provide a separate sea painter & weak link for the port side BA.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, replace all lines & repair all cracks on BAs.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Label/mark aft stairs for second deck to identify proper number of pax or crew allowed topside; make sure fwd and aft stair signage match.
Condition: Unknown
Due 23 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Provide missing cover for light fixture in the pilot house.
Condition: Unknown
Due 23 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, repair/replace retro tape on aft life ring buoy.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Lifesaving
Issued 9 October 2001 Resolved
Prior to the carriage of passengers, provide a total of six red flares for specified route.
Condition: Unknown
Due 9 October 2001
Resolved 30 October 2002
Navigation
Issued 9 October 2001 Resolved
Provide current copy of the U.S. Coast Pilot; vsl had the 4th Edition.
Condition: Unknown
Due 23 October 2001
Resolved 30 October 2002
Lifesaving
Issued 11 September 2000 Resolved
Provide new PFD donning placard.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Lifesaving
Issued 11 September 2000 Resolved
Renew retro-reflective tape on 65 adult and 8 child lifejackets.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Navigation
Issued 11 September 2000 Resolved
Provide updated charts for area transiting, new Tidal currents table and light list.
Condition: Unknown
Due 27 September 2000
Resolved 27 September 2000
Navigation
Issued 24 September 1999 Resolved
Correctly install stern navigation light prior to the carriage of passengers.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Fire Fighting
Issued 24 September 1999 Resolved
Weigh CO2 cylinders for fixed fire fighting system and tag system.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Lifesaving
Issued 24 September 1999 Resolved
Repair/replace buoyant apparatus wastage prior to the carriage of passengers.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Lifesaving
Issued 24 September 1999 Resolved
Repair starboard hand railing amidships-weld cracked at base of railing.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Electrical
Issued 24 September 1999 Resolved
Repair/Remove port generator block heater.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Construction/Loadline
Issued 24 September 1999 Resolved
Label bilge high level alarm panel in pilothouse.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Construction/Loadline
Issued 24 September 1999 Resolved
Install bilge high level visual alarms that meet 46 CFR 182.530.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Construction/Loadline
Issued 24 September 1999 Resolved
Provide hawse pipe downflooding closures on hawse pipes to chain locker.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Construction/Loadline
Issued 24 September 1999 Resolved
Provide gooseneck on ventilation pipe to forepeak to prevent down flooding.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Construction/Loadline
Issued 24 September 1999 Resolved
Repair hole in starboard side, forward engine room bulkhead beneath fixed system piping installation.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Engineering
Issued 24 September 1999 Resolved
Provide flame shield for starboard MDE fuel strainer.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Fire Fighting
Issued 24 September 1999 Resolved
Amend emergency fire fighting instructions to include fixed fire system operation and provide training in use of system to the crew.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Navigation
Issued 24 September 1999 Resolved
Provide charts and publications for vessel's area of operation.
Condition: Unknown
Due 24 September 1999
Resolved 24 September 1999
Lifesaving
Issued 29 September 1997 Resolved
REPLACE (02) WATERLIGHTS FOR BUOYANT APPARATUS.
Condition: Unknown
Due 29 September 1997
Resolved 29 September 1997
Documentation
Issued 29 September 1997 Resolved
PROVE PROPER COMPLIANCE WITH RANDOM DRUG TESTING PROGRAM PER 46 CFR 16.230.
Condition: Unknown
Due 6 October 1997
Resolved 22 October 1997
Lifesaving
Issued 11 February 1997 Resolved
Provide proper ring buoy & painter prior to operating with passengers.
Condition: Unknown
Due 12 February 1997
Resolved 12 February 1997
Lifesaving
Issued 30 October 1995 Resolved
RENEW SUN ROTTED PENDANTS ON BOTH 20 MAN BUOYANT APPARATI PRIOR TO SERVICE.
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Lifesaving
Issued 30 October 1995 Resolved
REMARK ALL LIFESAVING EQUIPMENT WITH VESSEL'S NEW NAME PRIOR TO SERVICE.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Fire Fighting
Issued 30 October 1995 Resolved
RESECURE FIRE HOSE WHERE CONNECTED TO STANDPIPE PRIOR TO SERVICE.
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Construction/Loadline
Issued 30 October 1995 Resolved
REPLACE LEAKING BILGE PUMP FLEX HOSE IN AFT COMPT. PRIOR TO SERVICE
Condition: Unknown
Due 30 October 1995
Resolved 30 October 1995
Engineering
Issued 17 November 1994 Resolved
REPAIR OR REPLACE AFT STRUT BEARINGS.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Navigation
Issued 17 November 1994 Resolved
REPACK BOTH RUDDER SEALS.
Condition: Unknown
Due 14 December 1994
Resolved 14 December 1994
Construction/Loadline
Issued 1 November 1994 Resolved
REPLACE PACKING IN RUDDER POSTS (PORT & STARBOARD) AT NEXT DRYDOCK.
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Construction/Loadline
Issued 22 November 1993 Resolved
FREE DOGS ON MAIN DECK HATCHES.
Condition: Unknown
Due 17 December 1993
Resolved 17 December 1993
Navigation
Issued 22 November 1993 Resolved
ADJUST PACKING GLAND NUTS ON RUDDER STOCK.
Condition: Unknown
Due 17 December 1993
Resolved 17 December 1993
Lifesaving
Issued 22 November 1993 Resolved
REPAIR OR REPLACE 12 PERSON BUOYANT APPARATUS. THE MAXIMUM PERSONS, INCLUDING CREW, ALLOWED ABOARD IS REDUCED TO 80 UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 22 November 1993
Resolved 22 November 1993
Accommodation/Occupational Safety
Issued 17 December 1990 Resolved
PROVIDE A MEANS TO LOCK SEWAGE OVERBOARD VALVE IN THE CLOSED POSITION AND POST SIGN STATING VALVE IS NOT TO BE OPEN WHILE OPERATING WITHIN TERRITORIAL WATERS.
Condition: Unknown
Due 17 December 1990
Resolved 17 December 1990
Lifesaving
Issued 28 November 1990 Resolved
PROVIDE ONE NEW RING BUOY
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Accommodation/Occupational Safety
Issued 28 November 1990 Resolved
RENEW SEWAGE HOLDING TANK.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Navigation
Issued 28 November 1990 Resolved
PROVIDE APPROVED NAVIGATION LIGHTS.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Construction/Loadline
Issued 29 January 1990 Resolved
PORT MAIN DIESEL ENG SEA SUCTION VALVE RENEWED.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Engineering
Issued 29 January 1990 Resolved
PORT & STBD PROPS RECONDITIONED.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Deck/Cargo
Issued 4 March 1988 Resolved
PROVE OPERATION OF ANCHOR WINCH.
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Documentation
Issued 26 April 1986 Resolved
OBTAIN FCC RADIOTELEPHONE SAFETY CERTFICATE
Condition: Unknown
Due 26 April 1986
Resolved 26 April 1986

Casualty record · 1

24 December 2012Routine · role: Involved in a Marine Casualty · activity 4507374
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record