MAURY USCG vessel records
← All vessels

ANOTHER REWARD

ANOTHER REWARD is a 1986 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in August 2025, along with 43 deficiencies, 1 operational control and 1 casualty investigation in 2012.

Records from 2012 to 2025. Most recent: inspection, 25 August 2025.

Built
1986
Last inspected
25 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDL7307
268185
Flag
UNITED STATES
Maury page id
psix-268185

Documentation record

Registered dimensions (L × B × D)64.8 ft × 21.8 ft × 7.6 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHARKERS ISLAND, NC, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational, Registry
DocumentationValid · issued 12 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

25 August 2025 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8217648
2 January 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8056818
5 December 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8035649
26 November 2024 Deficiency Check · Damage Survey
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8040496
7 June 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7932669
7 June 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8008731
30 November 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7831842
9 December 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7608500
2 November 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7588045
10 December 2021 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7411660
16 December 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7112661
4 September 2020 Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7047551
12 December 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6872396
11 December 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6595543
4 December 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6591693
29 November 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6348058
6 December 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6053198
16 November 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6042083

Deficiency record · 43

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 2 September 2025 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel radiotelephony certificate has incorrect call sign.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: Certificate updated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 September 2025 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering hoses are worn/degrading and required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: Hoses replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 September 2025 Resolved
A hatch exposed to the weather must be watertight. Hatch gasket for the aft rudder space is partially missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: gasket replaced.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 2 September 2025 Resolved
As appropriate for the intended voyage,all vessels must carry adequate and up-to-date-(a) Charts;. Vessel electronic charts have not been updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: charts updated.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 September 2025 Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. Fuel shut off valves are missing directions for operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 8 October 2025
Resolution: Proper instruction for fuel shut off valves installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connectors. Spring clips or other temporary type clamps are not permitted. Wing nuts found on multiple battery terminals
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: wing nuts removed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 2 September 2025 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Starboard main diesel is missing protective cover on belts at the fwd of engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: guards installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025 Resolved
Electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Electrical junction box on the outboard of port mde is missing cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: junction box removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 August 2025 Resolved
At all inspections special attention shall be paid to insure that no fire hazards exist and that guards or protective devices are provided in all hazardous places. Fuel filter for the Port MDE, has plastic drain plug that needs to be replaced with metal.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 25 September 2025
Resolution: Plastic drain plug replaced with metal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 January 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel failed to complete drydock exam by the required time. Vessel is restricted from carrying passengers until completing drydock.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2025
Resolved 10 January 2025
Resolution: DD/ISE completed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 December 2024 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Records do not indicate the person conducting the inspection and do not indicate what extinguisher was inspected.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: Monthly inspections are being completed and logged.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 5 December 2024 Resolved
The master or person in charge of a ship... shall ensure that one or more garbage placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers... Vessel is not equipped with garbage placards.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: New placards installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 December 2024 Resolved
All machinery shall be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The following non-conformities were identified: 1) All engine belts on engines were found loose 2) Breaker panel on bridge and engine room missing blanks 3) Starboard generator cooling pipe leaking 4) Starboard reduction gear leaking oil 46 CFR 182.01-5(a) OLD T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: All repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 December 2024 Resolved
The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. All bilge strainers have the same area as the suction pipe. 46 CFR 182.25-5(b) OLD T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: All bilge suction strainers replaced with metal of proper size.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2024 Resolved
Batteries... shall be effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Battery by port generator not protected. 46 CFR 183.05-20 OLD T
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: Plastic box used to cover batteries
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 December 2024 Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. Two sea water inlet pipes with flexible hose connections are not equipped with double hose clamps.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: Double hose clamps installed
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 5 December 2024 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Installed compass has no light.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 6 December 2024
Resolution: Replaced compass with a new compass that had a light installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 December 2024 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Retroreflective material on most life jackets worn and no longer serviceable.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2025
Resolved 5 March 2025
Resolution: New SOLAS tape installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 November 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Port side reduction gear experienced a failure of the drive plate.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 November 2024
Resolution: Replaced drive plate with new.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 June 2024 Resolved
Vessel was boarded by FWC operating outside of its approved route.
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 5 March 2025
Resolution: Closed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2024 Resolved
Violation of Law/ Regulation by credentialed mariner by operating outside of the scope of the COI. Vessel was found outside of 3nm by FWC.
Action required: 705 - Other - as specified
Due 7 June 2024
Resolved 5 March 2025
Resolution: Closed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 November 2023 Resolved
In addition to the other requirements of this section, 46 CFR 147.60 and 147.65 of this chapter require that -Carbon dioxide cylinders of all portable, semi portable, and fixed systems be tested and marked. - NOTE - Section 147.65 of this chapter includes a requirement that the cylinder must be retested and re-marked. Cylinders retested under any of the above conditions shall have new or renewed valve and safety relief devices of the proper design installed in the cylinder. 46 CFR 176.25-25(c)(1) Provide documentation of 12 year hydrostatic testing and servicing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2023
Resolved 8 December 2023
Resolution: fixed FF
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 November 2023 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. 46 CFR 180.25-5(a) Vessel is limited to carriage of 70 passengers until total number of life preservers is in compliance with the SECTOR MIAMI issued Certificate of Inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 December 2023
Resolved 30 November 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2022 Resolved
Fix all fuel leaks created from disassembly in the dry dock
Action required: 705 - Other - as specified
Due 3 January 2023
Resolved 16 December 2022
Resolution: All fuel leaks were addressed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 December 2022 Resolved
Replace the worn shaft support bearings port and stbd.
Action required: 705 - Other - as specified
Due 3 January 2023
Resolved 16 December 2022
Resolution: All worn bearings were replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 November 2022 Resolved
Each vessel certified under 46 CFR 176 must display the Certificate of Inspection on boar the vessel at all times. The certificate was not on board the vessel for inspection and according to the operator it was lost. Previous inspections with the same results of a lost COI resulted in the issuance of this prior to carrying passengers deficiency. 46 CFR 176.01-45
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 September 2020 Resolved
Found first aid kit with missing contents and expired equipment. Provide first aid kit with contents meeting 160.041 Q specs.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Verified purchase of new first aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 September 2020 Resolved
Provide current updated navigational charts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Verified purchase of new updated navigational chart.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 September 2020 Resolved
The grab lines on the ring buoy are deteriorated. Replace grab lines on ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Witnessed install of renewed grab lines on ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2020 Resolved
Missing 17 Adult L/J. 20 Adult L/J need proper SOLAS reflective tape and proper marking. Provide the appropriate number of life jackets as stated on the COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Observed life jackets with proper marking and replaced retroreflective material.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 September 2020 Resolved
Provide appropriate life jacket donning instructions and ensure instructions are properly posted.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Posted appropriate life jacket donning instructions.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 September 2020 Resolved
Install a pressure gauge on the outlet side of the fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Pressure gauge on fire pump installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 September 2020 Resolved
Port side service generator is in process of installation. Provide proof of proper operation of service generator after completed installation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Conducted satisfactory test of generator.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 September 2020 Resolved
Vessel not meeting minimum manning requirements. Operator instructed to meet the manning requirements of their COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Conducted satisfactory MOB drill with newly installed jacob's ladder and pulley system.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 12 December 2019 Resolved
FCC Station License and Bridge to Bridge certificates were both expired. Certified technician to conduct necessary inspections and certificates to be obtained.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: CLosed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 December 2019 Resolved
Dead end wiring found on main deck, upper deck (junction boxes), in engine compartment by stbd eng, and in tank room. Remove all dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 December 2019
Resolution: All dead end wiring was removed from the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 December 2019 Resolved
Bilge piping leading to pump on stbd engine had a pin hole leak at the elbow. Repair leak.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 March 2025
Resolution: CLosed
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 December 2019 Resolved
Original COI was not on board. COI shall be kept on board at all times.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 December 2019
Resolution: COI was placed on board.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 December 2018 Resolved
two overboard discharge valves (gate valves) found to be wasted and need to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2018
Resolution: both valves replaced with new gate valves.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 December 2018 Resolved
both breaker box's in wheel house missing covers and are creating a shock hazard. Replace covers.
Due 4 December 2018
Resolved 4 December 2018
Resolution: both covers were found on board and placed back in service.
Engineering › Bilge Water Management System › Interface Detector
Issued 16 November 2016 Resolved
A visual indicator must be provided at the operating station. Visual indicator for engine compartment not working. Fix indicator light. 46 CFR 182.530(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2016
Resolution: attending marine inspector tested bilge alarm lights and all functioned properly.
Lifesaving › Lifebuoys › Size
Issued 16 November 2016 Resolved
Ring buoys on Coastwise routes must be orange and 24 inches in diameter. Ring buoy on board is white and 20 inches. Replace with proper type and properly mark.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2016
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 16 November 2016 Resolved
A waste management plan shall be in place for the vessel. No waste management plan in place for the vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 16 November 2016

Casualty record · 1

24 December 2012Routine · role: Involved in a Marine Casualty · activity 4507374
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.