Records from 2016 to 2017. Most recent: inspection, 17 March 2017.
Inspection history · 4
17 March 2017
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6106586
14 March 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6101333
29 August 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5980964
1 February 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5804559
Communications › Radio Communications › VHF Radiotelephone
Issued 14 March 2017
Resolved
Atleast three two-way VHF radiotelephone appartus shall be provided. such apparatus shall conform to performance standards by the organization. PSCO observed GMDSS backup batteries without a non-replaceable seal. 74 SOLAS (14) III/6.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 17 March 2017
Resolution: RESOLVED ADMINISTRATIVELY THROUGH PHOTOGRAHIC PROOF.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 14 March 2017
Resolved
The minimum fire integrity of bulkheads and decks shall be as preserved in tables 44.1 and 44.2. PSCO discovered several areas of missing of missing A-60 structual fire protection in CO2 room on overhead and bulkhead adjacent to paint room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 March 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 29 August 2016
Resolved
0720- IF A CARBON DIOXIDE SYSTEM IS FITTED, THE QUANTITY OF GAS AVAILABLE SHALL AT LEAST BE SUFFICIENCT TO GIVE A MINIMUM OF FREE GAS EQUAL TO 45% OF THE LARGEST CARGO SPACE. IN ORDER TO COMPLY WITH STATED REGULATION, THE CO2 SYSTEM MUST BE AT 98.5% CAPACITY TO PROTECT THE SHIPS LARGEST CARGO SPACE, WHICH REQUIRES A MINUMUM OF 34.7 TONS. PSCO'S DISCOVERED THE LOW PRESSURE CO2 SYSTEM-SEE NARRATIVE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 September 2016
Resolved 2 September 2016
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 29 August 2016
Resolved
0680- SUITABLE ARRANGEMENTS SHALL BE MADE FOR EMBARKATION INTO THE LIFERAFTS, WHICH SHALL INCLUDE SUFFICIENT LADDERS TO FACILITATE EMBARKATION. EMBARKATION LADDER WAS WITNESSED TOO SHORT AND BROKEN.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 29 August 2016
Engineering › Lubricating Oil Service System › Tank
Issued 1 February 2016
Resolved
1440-BILGE PUMPING ARRANGEMENTS-After any survey of the ship has been completed no change shall be made in the machinery equipment without the sanction of the administration. An air vent line to the S.O. tank has a drain separator modification on the pipe, draining into the bilge well. SOLAS 74 I/11
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2016
Resolved 23 February 2016
Resolution: Air vent pipe was removed and flanged off.
Engineering › Diesel Engine (auxiliary) › Blower, Centrifugal
Issued 1 February 2016
Resolved
After any survey of the ship has been completed, no change shall be made in the machinery equipment without the sanction of the administration. The auxiliary blower has unapproved temporary flexible hose being used as drain lines.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2016
Resolved 23 February 2016
Resolution: The hose was replaced by a copper tube.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 February 2016
Resolved
0950-ELECTRIC EQUIPMENT IN GENERAL. All electrical apparatus shall be so constructed and insulated as not to cause injury when handled or touched. The electrical wire covering going to the cable junction box JB-S, located forward of the fire/Bilge pump is corroded. SOLAS 74(81) II-1/45.1.3, 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 March 2016
Resolved 23 February 2016
Resolution: The electrical wire covering was replaced with flexible covering.