Records from 1986 to 2008. Most recent: inspection, 28 November 2008.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 November 2008
Resolved
Replace E/R light fixture on overhead near PMDE damaged by fire on 11.28.08.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 5 May 2009
Resolution: Completed.
Electrical › Electric Supply System (service) › Cable
Issued 28 November 2008
Resolved
Renew conductors damaged by E/R fire on 11.28.08.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 5 May 2009
Resolution: Completed
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 November 2008
Resolved
Renew damaged exhaust pipe lagging on port diesel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 5 May 2009
Resolution: Completed
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 November 2008
Resolved
Clean soot from underdeck fire boundary insulation above port diesel engine. Replace/repair material as necessary to maintain boundary. Insure material used is acceptable by USCG as fire boundary insulation
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 January 2009
Resolved 5 May 2009
Resolution: Completed
Stability › Incline Test › General
Issued 12 June 2008
No resolution recorded
Submit stability calculations to MSC, for determination of changes to vessel's lightship characteristics since the last stability test, in 1998.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2009 — due date passed with no resolution recorded
Construction/Loadline › Structures › Door
Issued 12 June 2008
Resolved
Repair door latch, maind deck, aft/port
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 June 2008
Resolved
Repair door latch for galley electrical panel.
Due 19 June 2008
Resolved 19 June 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2008
Resolved
Provide eye wash for first aid kit.
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 June 2008
Resolved
Replace breaker switches with bad handles as discussed in bridge 12vdc panel
Due 19 June 2008
Resolved 19 June 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 June 2008
Resolved
Replace waterlight with cracked casing on port upper deck.
Due 19 June 2008
Resolved 19 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 June 2008
Resolved
Provide proof of pre-employment drug testing prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2008
Resolved 16 June 2008
Resolution: Spoke directly with Land, Sea, & Air: 5 crewmembers enrolled.
Lifesaving › Rescue Boat › Construction
Issued 12 June 2008
Resolved
Repair wasted and seized components on rescue boat davit (winch and turntable).
Due 19 June 2008
Resolved 19 June 2008
Lifesaving › Rescue Boat › Construction
Issued 12 June 2008
Resolved
Provide a guard for the rescue boat davit winch gear chain
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 12 June 2008
Resolved
Provide non conducting floor mats at all switchboards.
Due 19 June 2008
Resolved 19 June 2008
Engineering › Pressure Vessel › Foundation
Issued 12 June 2008
Resolved
Securely mount head water pressure tank and associated piping
Due 19 June 2008
Resolved 19 June 2008
Engineering › Steering Gear System › Interlock
Issued 12 June 2008
Resolved
Repair/adjust/provide limit switches to prevent rudder from contacting mechanical stops. Secure and do not use auto pilot until repaired, or remove completely. Do not use aft rudder angle indicator until repaired.
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 June 2008
Resolved
Repair door on electrical panel in security room.
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2008
Resolved
Repair spliced wire in security room overhead. All spliced wire is required to be in junction box.
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 June 2008
Resolved
Galley - repair steam table jucntion box cover
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 12 June 2008
Resolved
Galley - seal/repair jucntion box on stbd side.
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 June 2008
Resolved
Galley - repair cover for breaker panel
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 June 2008
Resolved
3rd deck - replace receptacle cover behind tv
Due 19 June 2008
Resolved 19 June 2008
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 12 June 2008
Resolved
3rd deck - steam table receptacle (440v) needs cover, prior to carrying passengers.
Due 19 June 2008
Resolved 19 June 2008
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 12 June 2008
Resolved
400 KW room generator - permanently repair air box j/w elbow
Due 19 June 2008
Resolved 19 June 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 12 June 2008
Resolved
400 KW generator - renew all 3 flexible hoses
Due 19 June 2008
Resolved 19 June 2008
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 12 June 2008
Resolved
400 kw generator - repair cooling water pipe brackets
Due 19 June 2008
Resolved 19 June 2008
Engineering › Freshwater System (air cooling) › Piping
Issued 12 June 2008
Resolved
440 room - a/c sea water cooling piping - make repairs to broken pipe.
Due 19 June 2008
Resolved 19 June 2008
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 12 June 2008
Resolved
On all diesel engines - apply hose clamps as discussed, specifically hoses from air boxes to murphy gauges.
Due 19 June 2008
Resolved 19 June 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2008
Resolved
make repairs to stbd m/e engine r/w ovbd where pinhole leaks exist.
Due 19 June 2008
Resolved 19 June 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 12 June 2008
Resolved
Repair port m/e exhaust lagging.
Due 19 June 2008
Resolved 19 June 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 June 2008
Resolved
Repair port main engine r/w piping at transmission cooler
Due 19 June 2008
Resolved 19 June 2008
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 June 2008
Resolved
Emergency escape from 440V generator room does not meet requirements of 46 CFR 177.500. Submit a proposal in writing to local OCMI to alter the existing configuration to meet the code. Much more detail: see 835 of 6/12/08
Action required: 705 - Other - as specified
Due 25 July 2009
Resolved 31 August 2009
Resolution: Company has proposed an alternative solution to the requirement.
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 March 2008
Resolved
Crop and renew longs as marked in aft void
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2008
Resolution: Longs are replaced
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 March 2008
Resolved
Repair and repack stuffing tubes under flying bridge platform, port and stbd.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 3 June 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 March 2008
Resolved
Inspect deck railing throughout vessel. Repair or replace as needed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 June 2008
Construction/Loadline › Structures › Superstructure
Issued 4 March 2008
Resolved
Crop and renew the bulkheads of the 3rd deck stairwell aft, entry into the lounge area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 3 June 2008
Fire Fighting › Fire Pumps › Location
Issued 4 March 2008
Resolved
Brace the fire pump and sprinkler system piping.
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 7 March 2008
Resolution: System is braced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 March 2008
Resolved
Properly pack bulkhead penetration between the engine room and the generator room.
Action required: 705 - Other - as specified
Due 4 April 2008
Resolved 3 June 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 4 March 2008
Resolved
Crop and renew tow longs in #2 void. Crop and renew the transverse frame in #2void on the stbd side of the stbd bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 March 2008
Resolution: The frame and the longs are replaced.
Fire Fighting › Fire Hydrants › Condition
Issued 26 February 2008
Resolved
Repair the station riser on the 3rd deck, stbd.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 April 2008
Resolved 27 March 2008
Resolution: Riser pipe was cropped and renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 15 December 2007
Resolved
While u/w, noticed smoke coming from the port transmission. Shut the engine down and returned to port using the stbd engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2007
Resolution: transmission repaired and satisfactory sea tril conducted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 December 2007
Resolved
Vessel must effect repairs to rails throughtout the vessel, but particularly on the after decks.
Condition: Improper/Lack of Maintenance
Due 30 June 2008
Resolved 12 June 2008
Resolution: Good progress has been made toward this deficiency
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 November 2007
Resolved
Prove proper operation of compass light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Compass light replaced and working.
Navigation › Piloting/Steering › Marine Charts
Issued 7 November 2007
Resolved
Provide current/corrected charts for Little River Inlet & AICW
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Current/corrected charts provided.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 November 2007
Resolved
Prove proper operation of both radars & GPS unit
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Both radars and GPS unit verified operational.
Communications › Audible Communications › Horn/Whistle
Issued 7 November 2007
Resolved
Prove proper operation of horn or whistle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Horn tested and operational
Lifesaving › Visual Distress Signals (General) › Storage
Issued 7 November 2007
Resolved
Provide container for flares and mark w/ 'Distress Signals'
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Flares and container provided.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 November 2007
Resolved
Prove proper oepration of pilot house control of propulsion and steering.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Sea trial conducted.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 November 2007
Resolved
Provide suitable arrangement for rail stringers on 2nd deck bow and stern; and any other passenger decks
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Rail courses corrected to four inches"
Communications › Alarms/Indicators › General Alarm
Issued 7 November 2007
Resolved
Prove proper operation of general alarm sounding on all decks.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: General alarm tested and operational on all decks
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 November 2007
Resolved
Prove proper operation of engine over-speed shutdowns & low-lube pressure alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Shut downs and alarms tested and operational
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 7 November 2007
Resolved
Prove proper operation of all pilot house and engine room gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: All guages and indicators checked and operational.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 November 2007
Resolved
Conduct satisfactory man over-board, fire fighting, anchor, and security drill.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Drills conducted--All Sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 November 2007
Resolved
Properly repair all splices in wiring and secure wiring with metal brackets every 24"
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: All wiring properly repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 November 2007
Resolved
Prove proper operation of bilge high water alarms and bilge suction system.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Bilge water management system tested and operational
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 November 2007
Resolved
Provide servicing report for fire equipment and IBA's
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Servicing reports provided.
Documentation › Certificates/Documents › Stability Letter
Issued 7 November 2007
Resolved
Provide new stability calculations to account for modifications made on 3rd deck.
Condition: Improper Installation
Due 21 December 2007
Resolved 7 March 2008
Resolution: New stability calcs provided and reviewed by MSC
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2007
Resolved
Vessel must be operated in accordance with the requirements in the proposal letter from southern elegance casino to CID charleston dated 19 NOV 07
Condition: Improper/Lack of Maintenance
Due 1 April 2008
Resolved 7 March 2008
Resolution: Vessel has made repairs to hull condition during yard period.
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2007
Resolved
Vessel must begin drydock NLT 14 MAR 2007
Condition: Improper/Lack of Maintenance
Due 14 March 2008
Resolved 7 March 2008
Resolution: Vessel completed credit drydock/ISE in Jax, FL
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 November 2007
Resolved
Vessel must effect repairs to deck railings NLT 31 MAY 2008 as per agreement on exiting yard period.
Condition: Improper/Lack of Maintenance
Due 31 May 2008
Resolved 3 June 2008
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 March 2007
Resolved
Remove fuel and oil from main integral fuel tank, gas free and make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Engineering › Bilge Water Management System › Piping
Issued 14 March 2007
Resolved
Prove proper operation of remote bilge shut-off valve in forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 14 March 2007
Resolved
Remove excessive rust scale from forepeak bilge to prevent clogging bilge strainer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Stability › Watertight Integrity › General
Issued 14 March 2007
Resolved
Replace hatch gaskets in way of forepeak and #1 void hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Stability › Watertight Integrity › General
Issued 14 March 2007
Resolved
Perform chalk test on both watertight doors in HVAC space and adjust as necessary.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 14 March 2007
Resolved
Repair emergency light in HVAC space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 14 March 2007
Resolved
Replace missing lighting fixture IVO obsolete sprinker valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Fire Fighting › Fire Main › Condition
Issued 14 March 2007
Resolved
Make permanent repairs to holed piping in engine compartment in way of #2 fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 March 2007
Resolved
Remove oil from bilges in auxiliary machinery space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2007
Resolved
Make permanent repairs to two punctures in bottom plating as indicated by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Construction/Loadline › Hull › Weld
Issued 14 March 2007
Resolved
Make permanent repairs to washed out/wasted weld in insert at bottom plating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2007
Resolved
Provide gauging report for areas immediately surrounding punctures in bottom plating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Engineering › Freshwater System (jacketwater cooling) › Suction Strainer
Issued 14 March 2007
Resolved
Remove screens on screens on port side and aft starboard side cooling water intakes and make ready for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2007
Construction/Loadline › Structures › Transverse Bulkhead
Issued 14 March 2007
Resolved
Make repairs to penetrations in watertight bulkhead between generator space and steering void.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 March 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 24 May 2006
Resolved
Provide valid safety radiotelephony certificate prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 May 2006
Resolution: Sighted certificate on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 May 2006
Resolved
Post vessel's stability letter and Certificate of Inspection.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted posted certificate and letter in pilothouse.
Fire Fighting › Fire Bucket › Stenciling
Issued 24 May 2006
Resolved
Stencil vessel's name on upper deck fire ax.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted name stenciled on ax.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 May 2006
Resolved
Display hailing port on vessel's stern.
Due 31 May 2006
Resolved 30 June 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Communications › Alarms/Indicators › General Alarm
Issued 24 May 2006
Resolved
Prove proper operation of general alarm bell in void 4, and on exterior upper deck.
Due 26 May 2006
Resolved 26 May 2006
Resolution: General alrm functioned to the satisfaction of the attending MI.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 24 May 2006
Resolved
Prove annual servicing of IBAs.
Due 24 June 2006
Resolved 17 November 2006
Resolution: Per fax receipt sent by O/O, receipt scanned into documents for this activity.
Lifesaving › Inflatable Buoyant Apparatus › Float Free
Issued 24 May 2006
Resolved
Provide new hydrostatic releases for IBAs.
Due 24 June 2006
Resolved 17 November 2006
Resolution: Per fax receipt sent by O/O, receipt scanned into documents for this activity.
Lifesaving › Launching Appliances › Lines
Issued 24 May 2006
Resolved
Replace rescue boat lifting straps.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted new straps.
Lifesaving › Rescue Boat › Markings
Issued 24 May 2006
Resolved
Stencil rescue boat with capacity.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted correct stenciling.
Lifesaving › Rescue Boat › Markings
Issued 24 May 2006
Resolved
Stencil rescue boat with correct hailing port.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted proper stenciling.
Fire Fighting › Ventilation Systems › Ducts
Issued 24 May 2006
Resolved
Prove proper operation of starboard side engineroom vent closure.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted proper operation of closure.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 May 2006
Resolved
Provide electrical insulating mat in way of switchboard.
Due 26 May 2006
Resolved 30 June 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2006
Resolved
Repair stuffing tubes on port A/C cooloing pump, A/C circulating pump controller, fire/bilge pump #2.
Due 24 June 2006
Resolved 30 June 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 May 2006
Resolved
Remove J-box in wireway on port side engineroom overhead.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted by attending MI.
Fire Fighting › Fire Pumps › Pressure
Issued 24 May 2006
Resolved
Replace gauge face on main fire pump pressure gauge.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted by attending MI.
Construction/Loadline › Structures › Manhole
Issued 24 May 2006
Resolved
Prove proper operation of emergency escape from engineroom.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted by atending MI.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2006
Resolved
Remove unapproved wire in engineroom raceway.
Due 26 May 2006
Resolved 26 May 2006
Resolution: Sighted by atending MI.
Operations/Management › Passenger Operations › Safety Orientation
Issued 24 May 2006
Resolved
Vessel restricted to no more than 150 passengers until vessel and facility security plans are approved- inform MSD Coram when plans are approved.
Action required: 705 - Other - as specified
Resolved 20 February 2007
Resolution: Completed a satisfactory MTSA Verifacation and security drill (Bomb threat).
Lifesaving › Rescue Boat › Carriage Requirement
Issued 24 May 2006
Resolved
Provide proper navigation lights for rescue boat prior to night operations.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 20 June 2006
Resolution: Sighted by attending MI.
Fire Fighting › Ventilation Systems › Ducts
Issued 24 May 2006
Resolved
Provide fusible link for A/C fire damper 2nd deck centerline starboard.
Due 3 June 2006
Resolved 30 June 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 17 October 2005
Resolved
Replace flame screen and vent panel on sewage vent pipe.
Condition: Unknown
Due 1 November 2005
Resolved 25 October 2005
Resolution: Installed new flame screen.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 17 October 2005
Resolved
Provide rubber insulation mat in front of circuit panel in engineer's office.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Installed new rubber matting.
Documentation › Markings/Placards › Warning Signs
Issued 17 October 2005
Resolved
Re-stencil aft emergency escape hatch.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: Stenciled hatch.
Engineering › Bilge Water Management System › Pump
Issued 17 October 2005
Resolved
Repair/replace leaking seals on bilge pump #1
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 20 October 2005
Resolution: Bilge pump replaced.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 October 2005
Resolved
Provide blank plates for generator distribution/circuit breaker board and engine room lighting circuit breaker panel.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Installed new blank plates.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 October 2005
Resolved
Permanently affix 230V outlet on inboard side of gen set circuit board by engine room ladder.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Properly mounted 230v outlet.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 October 2005
Resolved
Provide shatter guards for 02 lights in sprinkler room and light on 3rd deck aft doorway.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Installed new shatter guards.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 October 2005
Resolved
Prove proper operation of all exterior emergency deck lighting.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: Put all new bulbs in fixtures.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 October 2005
Resolved
Prove proper operation of stbd. 2nd deck emergency exit light/sign.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: Replaced light bulb.
Fire Fighting › Firemans Outfit › Axe
Issued 17 October 2005
Resolved
Permanently mount nav. bridge fire axe bracket.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: New bracket installed.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 October 2005
Resolved
Post emergency broadcast placard near radio station.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Posted placard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 October 2005
Resolved
Paint both port and stbd nav. light side screens black.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: Repainted black.
Lifesaving › Buoyant Apparatus › Marking
Issued 17 October 2005
Resolved
Repair life floats as necessary, provide lashings for all lifefloat paddles and repaint/stencil lifefloats and paddles.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: Took all corrective measures.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 October 2005
Resolved
Properly secure tv on 3rd deck to prevent movement.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Installed security straps.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 October 2005
Resolved
Properly label 3rd deck circuit breaker panel.
Condition: Improper Installation
Due 1 November 2005
Resolved 25 October 2005
Resolution: Labeled correctly.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 17 October 2005
Resolved
Provide non-combustible trash cans for all trash receptacles.
Condition: Improper Installation
Due 1 November 2005
Resolved 20 October 2005
Resolution: replaced all trash cans.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 October 2005
Resolved
Replace both life raft operating placards.
Condition: Damaged By Earlier Event
Due 1 November 2005
Resolved 20 October 2005
Resolution: Placards replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 17 October 2005
No resolution recorded
Provide proof of galley 2nd deck portable fire extinguisher servicing.
Condition: Improper Installation
Due 1 November 2005 — due date passed with no resolution recorded
Resolution: Serviced and tagged.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 October 2005
Resolved
Properly clean behind slot machine #68.
Condition: Unknown
Due 1 November 2005
Resolved 25 October 2005
Resolution: Cleaned.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 17 October 2005
Resolved
Provide proof of servicing and testing of both air receiver pressure relief valves.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: New valves installed.
Engineering › Generator (propulsion-electric) › Winding
Issued 17 October 2005
Resolved
Provide proper cleaning of oil from all generator windings in both the engine room and 400 kw room.
Condition: Improper/Lack of Maintenance
Due 1 November 2005
Resolved 25 October 2005
Resolution: Cleaned.
Engineering › Sea-water System (primary cooling) › Piping
Issued 16 December 2004
Resolved
New installation of stainless steel piping in cooling system had been joined temporarily with a soft patch.
Condition: Improper/Lack of Maintenance
Due 31 December 2004
Resolved 22 December 2004
Resolution: Welded piping sections at joint.
Engineering › Thrusters › Piping
Issued 16 December 2004
Resolved
Bow thruster hydraulic return line piping 'elbow' had a pinhole and was weeping fluid.
Condition: Unknown
Due 31 December 2004
Resolved 22 December 2004
Resolution: Clad welded piping elbow to stop weeping
Construction/Loadline › Hull › Stiffener
Issued 16 December 2004
Resolved
Fwd. peak void--stbd. #2 verticle support had cracks in the stich welds from an indenation of the shell plating.
Condition: Damaged By Earlier Event
Due 31 December 2004
Resolved 22 December 2004
Resolution: Cut out vertical support and rewelded to shell plate
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 December 2004
Resolved
Two Longitudinal frame members were rusted away in numerous areas of void #2.
Condition: Improper/Lack of Maintenance
Due 31 December 2004
Resolved 22 December 2004
Resolution: Cropped and renewed w/ new metal.
Engineering › Bilge Water Management System › Strainer
Issued 16 December 2004
Resolved
Bilge suction strainer in void #3 rusted away
Condition: Improper/Lack of Maintenance
Due 31 December 2004
Resolved 22 December 2004
Resolution: Replaced strainer
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 December 2004
Resolved
Multiple valve bodies in engine room needed to be cleaned thoroughly for inspection.
Condition: Improper/Lack of Maintenance
Due 31 December 2004
Resolved 22 December 2004
Resolution: Valve bodies cleaned
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 16 December 2004
Resolved
Provide flame safety rating data for new carpeting and furnishing that are being installed.
Condition: Unknown
Due 31 December 2004
Resolved 22 December 2004
Resolution: Data provided. Material is satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 21 October 2004
Resolved
50% of the marine crew to be CPR & First Aid certified prior to the carriage of passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2004
Resolved 26 October 2004
Resolution: 50% of the marine crew were trained and recertified in CPR & First Aid on 26 October 2004.
Documentation › Manuals/Policy Documentation › Maneuvering Information
Issued 21 October 2004
Resolved
Provide tide current tables.
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 26 October 2004
Resolution: Vsl''s rep provided proper tide currents tables.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 21 October 2004
Resolved
Remove & replace plastic trash cans with non-combustiable recepticals.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 10 November 2004
Lifesaving › Lifefloat › Lifeline
Issued 21 October 2004
Resolved
Properly repair all tag/life lines on life floats prior to operation or the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2004
Resolved 26 October 2004
Resolution: Vsl''s reps properly repaired all tag/life lines.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 October 2004
Resolved
Properly label bilge manifold.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 10 November 2004
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 21 October 2004
Resolved
Remove extension cord from 02 deck and in galley space where cooler is plugged in.
Action required: 705 - Other - as specified
Due 26 October 2004
Resolved 25 October 2004
Resolution: Vsl''s reps removed all extension cords.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 21 October 2004
Resolved
Properly repair/replace port light bulb on 02 deck, forward of door.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 26 October 2004
Resolution: Vsl''s reps replaced port light bulb on 02 deck.
Communications › Radio Communications › EPIRB
Issued 21 October 2004
Resolved
Prove proper testing of EPIRB hydro static release prior to the carriage of passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2004
Resolved 26 October 2004
Resolution: Vsl''s reps purchased and replaced EPIRB hydro static release.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 21 October 2004
Resolved
Provide updated & corrected fire control plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2004
Resolved 10 November 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 October 2004
Resolved
Properly repair wasted ladder rail on 02 deck.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 10 November 2004
Fire Fighting › Combustible Materials › Ceilings
Issued 21 October 2004
Resolved
Clean stbd sprinkler on 02 deck.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 26 October 2004
Resolution: Vsl''s reps clean stbd sprinkler on 02 deck.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 21 October 2004
Resolved
Properly repair water tight door to seal correctly in forward stbd void.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2004
Resolved 26 October 2004
Resolution: Vsl''s reps properly repaired water tight door.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 21 October 2004
Resolved
Seperate & properly stencil adult life preservers for passengers less than 90 lbs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 October 2004
Resolved 26 October 2004
Resolution: Vsl''s reps properly stenciled and seperated adult life preservers.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 October 2004
Resolved
Prove proper operation of bilge suction in aft compartments.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 26 October 2004
Resolution: Vsl''s reps proved proper operation of bilge suction in aft compartments.
Fire Fighting › Fire Pumps › Vacuum Pump
Issued 21 October 2004
Resolved
Fire pump gauge broken; replace fire pump gauge in generator room.
Action required: 705 - Other - as specified
Due 9 November 2004
Resolved 10 November 2004
Lifesaving
Issued 28 April 2003
Resolved
Repair broken life float net wire.
Due 12 May 2003
Resolved 27 August 2003
Electrical
Issued 28 April 2003
Resolved
Cover outlet box punch-out port side 2nd deck outboard.
Due 12 May 2003
Resolved 27 August 2003
Electrical
Issued 28 April 2003
Resolved
Replace breaker box blank in 2nd deck safe room.
Due 12 May 2003
Resolved 27 August 2003
Fire Fighting
Issued 28 April 2003
Resolved
Provide markings for fire extinguisher in 2nd deck safe room.
Due 12 May 2003
Resolved 27 August 2003
Electrical › Lighting (emergency)
Issued 28 April 2003
Resolved
Repair emergency light in generator room.
Due 12 May 2003
Resolved 27 August 2003
Electrical › Lighting (emergency)
Issued 28 April 2003
Resolved
Repair emergency light in engine room.
Due 12 May 2003
Resolved 27 August 2003
Accommodation/Occupational Safety
Issued 28 April 2003
Resolved
Make proper repair to cyprus room aft door hinge.
Due 12 May 2003
Resolved 27 August 2003
Lifesaving › Inflatable Liferafts
Issued 28 April 2003
Resolved
Have port liferaft serviced or replaced by 01Jun03.
Due 1 June 2003
Resolved 27 August 2003
Personnel › Manning/Qualifications
Issued 28 April 2003
Resolved
Provide additional DDE by 01Jun03.
Due 1 June 2003
Resolved 27 August 2003
Electrical › Lighting (service)
Issued 28 April 2003
Resolved
Provide cover for light in E/R.
Due 12 May 2003
Resolved 27 August 2003
Construction/Loadline
Issued 20 February 2003
Resolved
Make forepeak reachrod operable (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Construction/Loadline
Issued 20 February 2003
Resolved
Replace void #2 hatch cover and make watertight (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 March 2003
Resolution: Replaced hatch frame.
Stability › Watertight Integrity
Issued 20 February 2003
Resolved
Make watertight the two holes cut through watertight bulkhead stbd side in #2 void (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Fire Fighting › Ventilation Systems
Issued 20 February 2003
Resolved
Make all fire dampers operable in #3 void (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Fire Fighting › Ventilation Systems
Issued 20 February 2003
Resolved
Replace gaskets on fire damper covers in #3 void (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Stability › Watertight Integrity
Issued 20 February 2003
Resolved
Make all thru hull wiring cutouts, verticle and horizontal, watertight (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 20 February 2003
Resolved
Make stbd engine water pump valve operable (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Stability › Watertight Integrity
Issued 20 February 2003
Resolved
Make two lines fwd stbd side in generator room watertight (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Engineering
Issued 20 February 2003
Resolved
Put nut on bolt holding up exhaust trunk (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Engineering
Issued 20 February 2003
Resolved
Prove fwd and aft port side cutlass bearings are not worn more than 50% - If so, replace.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Resolution: Replaced all bearings.
Engineering
Issued 20 February 2003
Resolved
Make proper repair and give proper support to generator water pump supply piping in generator room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Stability › Watertight Integrity
Issued 20 February 2003
Resolved
Make thru hull penetrations in lazerette watertight watertight (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Stability › Watertight Integrity
Issued 20 February 2003
Resolved
Replace gaskets on all mahhole covers (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Construction/Loadline
Issued 20 February 2003
Resolved
Repair or replace fwd second deck stbd door (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Construction/Loadline
Issued 20 February 2003
Resolved
Provide UT shots of port sea chest. Provide extra shots one foot beyond sea chest (Issued deficiency as a worklist item only).
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2003
Resolved 28 February 2003
Resolution: Shots taken. Face of sea chest replaced.
Lifesaving › Lifebuoys › Stowage
Issued 4 October 2002
Resolved
Properly stack lifefloats. No more than 4ft high.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: deficiency corrected
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 October 2002
Resolved
prove proper operation of all fire dampers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: fire dampers operational
Fire Fighting › Means of Escape › Doorways
Issued 4 October 2002
Resolved
provide proper operation of fire doors, close and latch
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: deficiency corrected
Navigation › Piloting/Steering › Marine Charts
Issued 4 October 2002
Resolved
provide corrected and up to date charts, coast pilot, light list
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: deficiencies corrected
Stability › Watertight Integrity
Issued 4 October 2002
Resolved
provide lanyards and properly mark all water tight hatches. LEGACY COMPONENT DESC: watertight hatches
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: deficiency corrected
Documentation › Markings/Placards
Issued 4 October 2002
Resolved
properly label emergency escape hatches
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: deficiency corrected
Documentation › Markings/Placards › Capacity Marking
Issued 4 October 2002
Resolved
properly mark maximum capacity of uppermost deck.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: deficiency corrected
Fire Fighting › Automatic Sprinkler System
Issued 4 October 2002
Resolved
properly repair leaking pipe nipple in way of fire fighting sprinkler system tanks 2 and 3 LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 22 October 2002
Resolved 24 January 2003
Construction/Loadline › Structures
Issued 4 October 2002
Resolved
prove proper seal of engine room and generator room doors for CO2 release. LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Due 22 October 2002
Resolved 14 November 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 October 2002
Resolved
provide proper first aid kits LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 22 October 2002
Resolved 14 November 2002
Communications › Alarms/Indicators
Issued 4 October 2002
Resolved
provide lazarrette high level bilge alarm visual indicator LEGACY COMPONENT DESC: Bilge Alarm
Due 22 October 2002
Resolved 14 November 2002
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 October 2002
Resolved
prove proper operation of fwd void high bilge level switch
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2002
Resolved 8 October 2002
Resolution: deficiency corrected
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 October 2002
Resolved
replace lagging on all engine exhaust ports. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 22 October 2002
Resolved 14 November 2002
Fire Fighting › Automatic Sprinkler System
Issued 4 October 2002
Resolved
replace pipe nipple in sprinkler tanks 1-4 lower piping. LEGACY COMPONENT DESC: Sprinklers
Condition: Improper/Lack of Maintenance
Due 22 October 2002
Resolved 24 January 2003
Stability › Watertight Integrity
Issued 4 October 2002
Resolved
provide gasket for port lazarrette hatch cover LEGACY COMPONENT DESC: watertight hatches
Condition: Improper/Lack of Maintenance
Due 22 October 2002
Resolved 14 November 2002
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 4 October 2002
Resolved
provide updated and approved general arrangement plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 1 November 2005
Electrical › Electrical Distribution System (service)
Issued 4 October 2002
Resolved
properly label all electrical distribution panels/breakers LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Due 22 October 2002
Resolved 14 November 2002
Documentation › Safety/Response Plans/Programs
Issued 4 October 2002
Resolved
provide CO2 piping diagram LEGACY COMPONENT DESC: Fire Control Plans
Due 22 October 2002
Resolved 14 November 2002
Personnel › Training › Fire Fighting Basic
Issued 4 October 2002
Resolved
conduct man overboard and fire fighting drills
Due 22 October 2002
Resolved 8 October 2002
Resolution: deficiency corrected
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 4 October 2002
Resolved
update fire control plan LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 8 November 2002
Resolved 1 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 June 2002
Resolved
SYSTEM IS NOT SHUTTING DOWN ME's OR SSG's UPON ACTIVATION. LEGACY COMPONENT DESC: Operating Controls
Condition: Design Flaw
Due 7 October 2002
Resolved 7 October 2002
Documentation
Issued 25 October 2001
Resolved
VESSEL WAS BEING OPERATED UNDER AN INVALID CERTIFIATE OF DOCUMENTATION IN WAY OF FAILURE TO RENEW.
Condition: Unknown
Due 25 October 2001
Resolved 25 October 2001
Electrical
Issued 27 July 2001
Resolved
MAKE PROPER REPAIRS TO 400KW GENERATOR AND PROVE PROPER OPERATION
Condition: Unknown
Due 20 September 2001
Resolved 23 October 2001
Electrical
Issued 27 July 2001
Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAY FOR #2 GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 2001
Resolved 23 October 2001
Electrical
Issued 27 July 2001
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN MACHINERY SPACES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 September 2001
Resolved 23 October 2001
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 27 July 2001
Resolved
SUBMIT A PROPOSAL FOR THE PROPER INSTALLATION OF MANUAL ALARMS IN ALL ACCOMODATION SPACES IN ACCORDANCE WITH 46 CFR 118.400 (f).
Condition: Unknown
Due 27 August 2001
Resolved 1 November 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 27 July 2001
Resolved
SUBMIT A PROPOSAL FOR THE PROPER INSTALLATION OF FIXED FIRE FIGHTING SYSTEMS IN THE FOLLOWING SPACES; ENGINE ROOM, 400KW GENERATOR ROOM, AND EMERGENCY GENERATOR ROOM IN ACCORDANCE WITH 46 CFR 118.400.
Condition: Unknown
Due 27 August 2001
Resolved 1 November 2005
Engineering
Issued 27 July 2001
Resolved
PROVE PROPER OPERATION OF TACHOMETERS.
Condition: Unknown
Due 20 September 2001
Resolved 23 October 2001
Electrical
Issued 1 November 1999
Resolved
REPLACE INJECTOR FOR STBD SIDE GENERATOR.
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
CLEAN BILGE LINE STRAINER IN AFTER LAZARETTE.
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Electrical
Issued 1 November 1999
Resolved
SECURE STARTING SWITCH FOR PORT GENERATOR
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Fire Fighting
Issued 1 November 1999
Resolved
RENEW GAUGE FOR FIRE PUMP IN ENGINE ROOM.
Condition: Unknown
Due 2 November 1999
Resolved 2 November 1999
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 November 1999
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE CONDUCT EMERGENCY DRILLS.
Condition: Unknown
Due 1 December 1999
Resolved 1 November 2005
Unknown
Issued 28 July 1999
Resolved
Provide certificate of annual servicing of elevator
Condition: Unknown
Due 5 August 1999
Resolved 2 September 1999
Unknown
Issued 28 July 1999
Resolved
Properly post stability letter.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Fire Fighting
Issued 28 July 1999
Resolved
Main deck fire screen doors fail to close properly. Trouble shoot repair and prove proper operaion of fire sceen doors.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Construction/Loadline
Issued 28 July 1999
Resolved
Provide missing coaming for aft door coaming main deck and properly bolt all door coamings in place.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Electrical
Issued 28 July 1999
Resolved
Numerous wiring penetrations not properly secured in panel boxes and other penerations. Junction boxes adrift. Properly secure all wiring runs, junction boxes and fixtures.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Fire Fighting
Issued 28 July 1999
Resolved
Properly mount all portable fire extinguishers in accordance with NFPA 10.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Fire Fighting
Issued 28 July 1999
Resolved
Provide proper vent closure for the security space ventilation duct.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Electrical
Issued 28 July 1999
Resolved
Panelboard directories missing switching directories. Provide circuit directory card holder required by 46CFR 111.40-11.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Unknown
Issued 28 July 1999
Resolved
Properly secure all pipe runs in accordance with ANSI including air supply piping from air receiver #2.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Unknown
Issued 28 July 1999
Resolved
Renew oil soaked and buckled hose providing cooling water for exhaust manifold.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Unknown
Issued 28 July 1999
Resolved
Oil presure guage sending unit oil line jury jury rigged with hose. Renew sending unit oil line as original.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Unknown
Issued 28 July 1999
Resolved
Prove proper operation of Cypress deck doors and door closures.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Engineering
Issued 28 July 1999
Resolved
Emergency fuel shut off valves located in a locked space. Make emergency fuel shut off valves accessible.
Condition: Unknown
Due 5 August 1999
Resolved 30 August 1999
Lifesaving
Issued 27 January 1999
Resolved
Replace float light bracket top deck aft.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Navigation
Issued 27 January 1999
Resolved
Provide Radio Operators Permit, prior to sailing.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Lifesaving
Issued 27 January 1999
Resolved
Conduct abandon ship drill prior to operating.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Navigation
Issued 27 January 1999
Resolved
Repair rudder angle indicator in aft steering so that in operates under emergency power, prior to sailing.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Construction/Loadline
Issued 27 January 1999
Resolved
Repair water tight door alarms port/stb sides below main deck.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Documentation
Issued 27 January 1999
Resolved
Provide chief engineer license, prior to sailing
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Lifesaving
Issued 27 January 1999
Resolved
Conduct manoverboard drill prior to operating.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Navigation
Issued 27 January 1999
Resolved
Prove compliance with GMDSS requirements.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Lifesaving
Issued 27 January 1999
Resolved
Conduct firefighting drill prior to operating
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Navigation
Issued 27 January 1999
Resolved
Repair steering pump run lights in aft steeing so that they operate while using emergency power, prior to operating.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Navigation
Issued 27 January 1999
Resolved
Repair or adjust the low steering oil level alarm. Alarm level set too high and trips continuously.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Electrical
Issued 27 January 1999
Resolved
Repair low oil level alarm on #1 generator.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Electrical
Issued 31 October 1998
Resolved
PROVIDE EMERGENCY LIGHTING IN AREAS THROUGHOUT THE VESSEL WHICH OPERATES UNDER TEMPORARY EMERGENCY LOAD AS REQUIRED BY 46 CFR 112.15, 46 CFR 112.37,AND 46 CFR 112.39.
Condition: Unknown
Due 31 October 1998
Resolved 31 October 1998
Documentation
Issued 31 October 1998
Resolved
REVISE AND OBTAIN APPROVAL FROM THE CG MARINE SAFETY CENTER, FOR THE ELECTRICAL SYSTEM PLANS, WHICH REFLECT "AS BUILT" CONDITIONS ABOARD THE VESSEL.
Condition: Unknown
Due 31 October 1998
Resolved 31 October 1998
Accommodation/Occupational Safety
Issued 31 October 1998
Resolved
MAKE REPAIRS TO AND PROVE OPERATION OF THE SHIP'S PASSENGER ELEVATOR INCLUDING ALL ALARMS, COMMUNICATION DEVICES AND FAILSAFE DEVICES. UNTIL SATIFACTORILY TESTED IN THE PRESENCE OF A CG MARINE INSPECTOR, ELEVATOR TO REMAIN LOCKED-OUT, INACCESSIBLE TO PASSENGERS, AND POSTED "OUT OF ORDER".
Condition: Unknown
Due 30 November 1998
Resolved 6 November 1998
Navigation
Issued 31 October 1998
Resolved
INSTALL & PROVE OPERATION OF MOTOR RUNNING LIGHTS FOR THE STEERING MOTORS, REQUIRED IAW 46CFR58.25-25. UNTIL INSTALLED & TESTED, THE ENGINEER ON WATCHAT THE CONTROL STATION SHALL MAINTAIN CONSTANT COMS WITH THE BRIDGE, FOL- LOWING SPECIFIC WRITTEN INSTRUCTIONS DURING ANY TRANSFER OF STEERING PUMPS.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Lifesaving
Issued 31 October 1998
Resolved
PROVIDE ALL ITEMS REQUIRED BY 46 CFR 160.040-4 FOR THE ROCKET LINE THROWINGDEVICE.
Condition: Unknown
Due 6 November 1998
Resolved 12 November 1998
Documentation
Issued 31 October 1998
Resolved
OBTAIN AND POST COPIES OF THE FIRE CONTROL (SAFETY) PLAN THROUGHOUT THE VESSEL. PLAN APPROVAL TO BE CONDUCTED BY THE COAST GUARD MARINE SAFETY OFFICE, SAVANNAH, GA.
Condition: Unknown
Due 6 November 1998
Resolved 6 November 1998
Construction/Loadline
Issued 17 February 1995
Resolved
VSL IS NOT TO CARRY PASSENGERS OR MOVE FROM CURRENT MOORINGS UNTIL SUCH TIME VSL IS IN FULL COMPLIANCE WITH COI.
Condition: Unknown
Due 17 February 1995
Resolved 17 February 1995
Engineering
Issued 15 December 1994
Resolved
VSL'S ENGINES WILL NOT OPERATE DUE TO IMPROPER STORAGE. VSL SHALL BE PROPERLY WINTERIZED AND REINSPECTED PRIOR TO CARRYING PASSENGER OR LEAVING THE IMMEDIATE AREA.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Engineering
Issued 15 December 1994
Resolved
VSL'S ENGINE WILL NOT OPERATE DUE TO IMPROPER STORAGE. VSL SHALL BE PROPERLY WINTERIZED AND REINSPECTED PRIOR TO CARRYING PASSENGERS OR LEAVINGTHE IMMEDIATE AREA.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Electrical
Issued 13 September 1994
Resolved
REMOVE ENGINE TRIP ON THE HIGH TEMP. SENSOR ON THE EMERGENCY GENERATOR PER 46 CFR 112.50-1(i)
Condition: Unknown
Due 13 September 1994
Resolved 13 September 1994
Electrical
Issued 7 April 1994
Resolved
PROVIDE RUBBER MAT FOR SHORE POWER PANEL.
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Lifesaving
Issued 7 April 1994
Resolved
RELOCATE EMPLOYEE BREAK ROOM AWAY FROM EMERGENCT SWITCHBOARD
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Electrical
Issued 7 April 1994
Resolved
PROVIDE DRIP PAN FOR THE EMERGENCY SWITCHBOARD
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Electrical
Issued 7 April 1994
Resolved
PROVIDE RUBBER MAT FOR EMERGENCY SWITCHBOARD
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Fire Fighting
Issued 7 April 1994
Resolved
INSTALL CLOSURE SWITCH FOR STAIR TOWER DOORS
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Electrical
Issued 15 September 1993
Resolved
REPAIR LIGHTING CIRCUIT FOR SECONDARY STERN LIGHT.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
IN PRESENCE OF MARINE INSPECTOR SATISFACTORILY TEST OVERSPEED TRIP FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 15 September 1993
Resolved
INSTALL GENERAL ALARM BELL (RINGER) IN CREW SPACES LOCATED BELOW DECK (HOLDAREA).
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 15 September 1993
Resolved
PROPERLY LABEL GENERAL ALRM CONTACT MAKER IN PILOTHOUSE.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
REPLACE JUNCTION BOX COVERS IN POKER ROOM, CASINO DECK A/C ROOM AND AT AFT BLKD IN ENGINEROOM.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Engineering
Issued 15 September 1993
Resolved
LABEL "MURPHY" ALARMS AT AFT CONTROL STATION.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Fire Fighting
Issued 15 September 1993
Resolved
INSTALL DISCHARGE GAUGE FOR AUX FIRE PUMP.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Engineering
Issued 15 September 1993
Resolved
REPAIR/REPLACE GAUGES FOR STBD MAIN DIESEL LOCATED IN PILOTHOUSE.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
REMOVE LOOSE WIRE BUNDLE IN PILOTHOUSE.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 15 September 1993
Resolved
PROPERLY LABEL ALL GENERAL ALRM BELLS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 15 September 1993
Resolved
WATERLIGHT ON RING BUOY WAS BROKEN (CASING CRACKED).
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 15 September 1993
Resolved
"E" LIGHTS NOT LABELLED.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 15 September 1993
Resolved
SECURE GENERAL ALARM WIRING AFT MAIN DECK.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Lifesaving
Issued 15 September 1993
Resolved
PROPERLY SECURE THE GENERAL ALRM WIRING IN THE PILOTHOUSE.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
PROPERLY SECURED THE WIRING FOR THE TELEPHONE AND PA SYSTEM IN THE PILOTHOUSE.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
IN PRESENCE OF MARINE INSPECTOR SATISFACTORILY TEST THE OVERSPEED TRIP AND THE SHUTDOWN AND VISIBLE & AUDIBLE ALARMS FOR LOW LUBE OIL ON THE AUX GENERATOR (400KW).
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Fire Fighting
Issued 15 September 1993
Resolved
VERIFY IN PRESENCE OF MARINE INSPECTOR THE OPERATION OF THE POWER VENT SHUTDOWNS TO THE PASSENGER DECKS (3).
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
REPLACE ALL LIGHT GLOBES AND GUARDS THROUGHOUT THE VESSEL AS NEEDED.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
REPAIR CASINO-HURRICANE DECK STAIR LIGHT (EXTERIOR DECK - AFT).
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
DISCONNECT THE SHUTDOWNS ON THE EMERGENCY GENERATOR FOR LOW LUBE OIL AND HIGH WATER TEMPERATURE.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 15 September 1993
Resolved
INSTALL AUDIBLE ALARMS FOR LOW LUBE OIL AND HIGH WATER TEMPERATURE ON THE EMERGENCY DIESEL GENERATOR.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Engineering
Issued 18 May 1993
Resolved
DOUBLE CLAMP ALL COOLING WATER HOSE CONNECTIONS TO MAINS AND GENERATORS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Navigation
Issued 18 May 1993
Resolved
INSTALL DOUBLE NUTS ON THE RUDDER INDICATOR FEED BACK UNIT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
MOUNT ELECTRICAL OUTLET BOX HANGING OVER 400 KW GENERATOR.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
INSTALL LIFE LINES ON SIDES OF BOTH GANGWAYS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Navigation
Issued 18 May 1993
Resolved
REPAIR DEPTH FINDER.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Engineering
Issued 18 May 1993
Resolved
DEMONSTRATE OVERSPEEDS ON THE MAIN ENGINES.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
LABLE AFTER LIFE RAFT STATION.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
POST KEEP CLEAR EMERGENCY EXCAPE SIGN OUTSIDE OF AUX GENERATOR SPACE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
LABLE GENERAL ALARM BELL LOCATED ON MAIN DECK BOW.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
INSTALL MEANS TO SECURE SODA MACHINE CO2 BOTTLE IN CASINO DECK BAR.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Fire Fighting
Issued 18 May 1993
Resolved
REPAIR AUX FIRE PUMP.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
REPLACE MISSING LIGHT COVER ON LIGHT OVER AUX FIRE PUMP IN ENG. ROOM.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Unknown
Issued 18 May 1993
Resolved
PAINT NAME OF VESSEL ON BOTH SIDES OF BOW AND AGAIN ON THE STERN WITH THE HOME PORT IN AT LEAST 4 INCH LETTERS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 2 March 1993
Resolved
SUBMIT PROPOSAL FOR THE CORRECTION OF VIDEO ROOM ESCAPE PROBLEM NOTED IN THE 18 FEB 93 LETTER SER H2-30124 FROM COMDT(MSC) PARA 5._x001C_
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Fire Fighting
Issued 2 March 1993
Resolved
PROVIDE EVIDENCE THAT 3/4 INCH PIPING OF THE SPRINKLER SYSTEM IS AT LEAST SCHEDULE 40.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Accommodation/Occupational Safety
Issued 2 March 1993
Resolved
THE PASSENGER ELEVATOR ELECTRIC POWER SUPPLY MUST BE ARRANGED TO BE POWEREDFROM THE FINAL EMERGENCY POWER SOURCE, I.E., EMERGENCY GENERATOR.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Fire Fighting
Issued 2 March 1993
Resolved
INSTALL A-15 INSULATION ON THE OVERHEAD BETWEEN FRAMES 20-31 AND THE PORTION OF BULKHEAD 31 ON THE PORT SIDE IN THE AREA LABELED STORAGE. REFERENCE COMDT(MSC) LETTER 18 FEB 93, SER H2-30130 PARA. 6 OR CHANGE DESIGNATION.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Accommodation/Occupational Safety
Issued 2 March 1993
Resolved
SUBMIT THE HYDRAULIC POWER SYSTEM DRAWINGS FOR THE ELEVATOR TO THE MARINE SAFETY CENTER FOR REVIEW.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Fire Fighting
Issued 2 March 1993
Resolved
INSTALL SPRINKLER SYSTEM ON THE 03 DECK. IAW NAVICS 14-91
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Fire Fighting
Issued 2 March 1993
Resolved
INSTALL FIRE DAMPENERS IN MAIN ENGINEROOM.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Navigation
Issued 29 January 1993
Resolved
PROVIDE FCC LICENSE IN OPERATOR'S NAME.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Engineering
Issued 29 January 1993
Resolved
PROVIDE GUARD TO NO.1 SHIPS SERVICE GENERATOR FLYWHEEL.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Fire Fighting
Issued 29 January 1993
Resolved
PROVIDE STRAINER FOR AUXILIARY FIRE PUMP.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Electrical
Issued 29 January 1993
Resolved
PERMANENTLY LABEL ALL CIRCUITS IN EACH PANEL BOARD.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Fire Fighting
Issued 29 January 1993
Resolved
PROVIDE SWITCH FOR MAIN FIRE PUMP AT ENGINEER'S STATION.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Construction/Loadline
Issued 29 January 1993
Resolved
INSTALL BILGE LEVEL ALARM UNDER AUXILIARY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Lifesaving
Issued 29 January 1993
Resolved
STAMP/MARK THE VESSEL'S NAME ON THE 150 NEW PFD'S STORED UNDER BLACKJACK TABLES.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 29 January 1993
Resolved
PERMANENTLY MOUNT ALL RING LIFE BOUYS.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 29 January 1993
Resolved
PROVIDE ONE ADDITIONAL WATER LIGHT TO THE RING BOUY MOUNTED AT THE PILOT HOUSE.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
REMOVE CARPET FROM UNDERNEATH ALL FIRE DOORS.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
PERMANENTLY MOUNT HEATER IN PILOT HOUSE.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Electrical
Issued 29 January 1993
Resolved
MAKE ELECTRICAL CONNECTIONS THAT TRANSIST THROUGH WATER TIGHT BULKHEADS WATERTIGHT.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Lifesaving
Issued 29 January 1993
Resolved
PROVIDE WEAK LINKS FOR EACH LIFERAFT.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Engineering
Issued 29 January 1993
Resolved
PROVIDE GUARDS FOR PULLEYS ATTACHED TO THE VESSEL'S BOW THRUSTER.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Fire Fighting
Issued 29 January 1993
Resolved
DEMONSTRATE THE OPERATION OF A UL 1-1/2 HR FIRE DAMPER WITH REMOTE PULL. THE DAMPER IS LOCATED IN THE AUX MACH'Y SPACE VENT BOX PORT SIDE.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
REPAIR VENTILATION DUCT OUTSIDE MAIN ENGINE ROOM(STARBOARD SIDE).
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Navigation
Issued 29 January 1993
Resolved
PROVIDE THE FOLLOWING PUBLICATIONS: NOTICE TO MARINERS, LIGHT LIST, NAVIGATION RULES, AND RIVER CHART.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Documentation
Issued 29 January 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Documentation
Issued 29 January 1993
Resolved
POST OIL POLLUTION PLCARDS.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Engineering
Issued 29 January 1993
Resolved
PROVIDE OVERSPEED TRIPS ON PORT AND STB MAIN DIESEL ENGINES.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Engineering
Issued 29 January 1993
Resolved
MOUNT WRENCH FOR EMERGENCY FUEL SHUT OFF NEAR DECK FITTING.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 29 January 1993
Resolved
PROVIDE GUARDS/RAILS AROUND INFLATABLE BOUYANT APPARATUS AND REMOVE THE SAME FROM OUTBOARD OF THE INFLATABLES SO THEY WILL FLOAT FREE OR EASILY BE PUSHED OVER THE SIDE.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
THE HYDRAULIC POWER SYSTEM FOR THE ELEVATORS SHOULD BE SUBMITTED FOR REVIEW. IT WILL BE REVIEWED IN ACCORDANCE WITH 46 CFR 58.30-30. SEE 46 CFR 58.30-50. (MARINE SAFETY CENTER LTR 17710/OFFS 39 SERIAL: EMH2-30045 DATED 2 FEB 93.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
AS PER REQUIRED BY MARINE SAFETY CENTER LETTER 16710/OFFS 39 SERIAL: EMH2-30045 2 FEB 93 DWG. NO. 2, REV. 1, CONTRACT NO. 1003 CAB SHALL BE RESUBMITTED (SCHUMACHER ELKEVATOR CO. DRWG).
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Navigation
Issued 29 January 1993
Resolved
INSTALL NAVIGATION LIGHTS IN ACCORDANCE WITH 46 CFR 111.75-17 (DUAL LIGHTS/NAVIGATION LIGHT INDICATOR PANEL WITH VISUAL AND AUDIBLE SIGNAL).
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Deck/Cargo
Issued 29 January 1993
Resolved
DEMONSTRATE ANCHOR OR PROVIDE EVIDENCE THAT EXISTING ANCHOR IS ADEQUATE FORPRESENT OPERATING AREA. I.E., MISSOURI RIVER.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
PROVIDE MANUFACTURES SAFETY DATA SHEETS FOR All HAZARDOUS PRODUCTS, I.E., CLEANING SOLVENTS, DEGREASERS, ETC..
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Electrical
Issued 29 January 1993
Resolved
REPAIR LOW PRESSURE SWITCH AND REVERSE POWER SWITCH FOR #1 SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Lifesaving
Issued 29 January 1993
Resolved
PERMANENTLY MOUNT RESCUE BOAT.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 29 January 1993
Resolved
CONDUCT SATISFACTORY TEST OF FWD BILGE SUCTION.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Construction/Loadline
Issued 29 January 1993
Resolved
PROVIDE STABILITY ANALYSIS TO ALLOW PASSENGERS ON THE UPPER DECK WHILE UNDERWAY AND IN PORT.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Construction/Loadline
Issued 29 January 1993
Resolved
BILGE PIPING REMAINS UNDERSIZED. THIS ISSUE SHALL BE READDRESSED WITH MARINE SAFETY CENTER-WASHINGTON DC.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Accommodation/Occupational Safety
Issued 29 January 1993
Resolved
POTABLE WATER VENT SHALL HAVE A MEANS OF CLOSURE (46 CFR 50-85(A)(7).
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Electrical
Issued 29 January 1993
Resolved
AS STATED IN MARINE SAFETY CENTER LETTER DATED 24 NOV 92 ALL ELECTRICAL DRAWING SHALL BE RESUBMITTED AND COMMENTS ADDRESSED.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Engineering
Issued 29 January 1993
Resolved
CONDUCT NAVIGATIONAL SAFETY TEST IN PRESENCE OF COAST GUARD MARINE INSPECTOR PRIOR TO GETTING UNDERWAY WITH PASSENGERS ONBOARD.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Electrical
Issued 29 January 1993
Resolved
PROVIDE SPOTLIGHTS FROM THE "E" CIRCUIT FIR ILLUMINATION OF RESCUE BOAT ANDINFLATABLE RAFT LAUNCHING AREAS.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Engineering
Issued 29 January 1993
Resolved
CONDUCT OPERATIONAL TEST OF BOW THRUSTER.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Fire Fighting
Issued 29 January 1993
Resolved
PROVIDE FOG APPLICATOR FOR ENGINE ROOM FIRE NOZZLE.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Fire Fighting
Issued 9 December 1991
Resolved
PROVE PROPER OPERATION OF VENT SHUTDOWN FIXED EXTINGUISHING SYSTEM IN GALLEY.
Condition: Unknown
Due 9 December 1991
Resolved 9 December 1991
Fire Fighting
Issued 9 December 1991
Resolved
PROVIDE 9 (NINE) USCG. ACCEPTED (LINED) FIRE HOSES FOR ALL 9 (NINE) FIRE STATIONS.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 9 December 1991
Resolved
CLEAN GALLEY VENT HOOD.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 9 December 1991
Resolved
DEMOSTRATE PROPER OPERATION OF MSD TO USCG APPROVED SPECIFICATIONS OR REPLACE WITH USCG APPROVED DESIGN.
Condition: Unknown
Due 9 December 1991
Resolved 9 December 1991
Engineering
Issued 9 December 1991
Resolved
DEMOSTRATE PROPER OPERATION OF MDE SHUTDOWNS ON BRIDGE.
Condition: Unknown
Due 9 December 1991
Resolved 9 December 1991
Electrical
Issued 9 December 1991
Resolved
PROVE PROPER OPERATION OF OVERSPEED SHUTDOWN ON GENERATOR #2
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Accommodation/Occupational Safety
Issued 9 December 1991
Resolved
REMOVE OLD WATER HEATER UNDER LADDER IN GALLEY VOID.
Condition: Unknown
Due 22 January 1992
Resolved 22 January 1992
Navigation
Issued 9 December 1991
Resolved
DEMOSTRATE PROPER OPERATION OF SOUND POWERED PHONE IN ENGINE ROOM AND BRIDGE, ALSO VISUAL ALARM IN ENGINE ROOM. THE ABOVE REQUIREMENTS ARE TO BECOMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 December 1991
Resolved 9 December 1991
Engineering
Issued 3 December 1990
Resolved
PROVIDE PROPER INSULATION FOR VERTICAL EXHAUST PORT MDE. (APPROX. 3 FEET FROM ENGINE TO DECK ABOVE)
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Engineering
Issued 3 December 1990
Resolved
PROPERLY LABEL ALL REMOTE FUEL OIL SHUTDOWNS. (IN WAY OF GALLEY SPACE TOPSIDE).
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Electrical
Issued 3 December 1990
Resolved
PROVE PROPER OPERATION OF OVER SPEED DEVICES FOR #2 GENERATOR.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Electrical
Issued 3 December 1990
Resolved
REPLACE ALL "WIRE NUTT" CONNECTORS WITH APPROVED IN LINE CONNECTORS AND PROVIDE CONNECTORS FOR WIRING OF ORCA SANITATOR DEVICE CIRCUIT PANEL.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 3 December 1990
Resolved
PROVIDE SAFETY CHAIN ON PERSONNEL ENTRY COVERS FOR #1 FOREPEAK AND #2 COMPARTMENTS; AND STEERING COMPARTENT.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 3 December 1990
Resolved
PROVIDE PROPER PERSONNEL ENTRY LOWER FOR 2 COMPARTMENT (VOID SPACE).
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Electrical
Issued 21 December 1989
Resolved
REMOVE ELECTRICAL CABLE IN STBD OUTBOARD GALLEY STOREROOM AND PORT OUTBOARD.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Engineering
Issued 21 December 1989
Resolved
MARK PROPER LOCATION OF ALL BILGE SUCTION VALVES.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Engineering
Issued 21 December 1989
Resolved
PROVE PROPER OPERATION OF ALL ENGINE GAGES LOCATED IN THE WHEELHOUSE.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Unknown
Issued 21 December 1989
Resolved
REMOVE EXCESS OIL FROM ENGINEROOM BILGE.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Accommodation/Occupational Safety
Issued 21 December 1989
Resolved
HYDROSTATICALLY TEST BOTH AIR RECEIVERS INTHE ENGINEROOM.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Navigation
Issued 21 December 1989
Resolved
PROVIDE APPROVED NAVIGATION LIGHTS.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Lifesaving
Issued 21 December 1989
Resolved
PROPERLY MARK ALL LIFE PRESERVER CONTAINERS.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Electrical
Issued 21 December 1989
Resolved
PROVE PROPER OPERATION OF PORT AND STBD GENERATOR OVERSPEEDS.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Lifesaving
Issued 21 December 1989
Resolved
PROPERLY STORE ALL LIFE PRESERVERS.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Lifesaving
Issued 21 December 1989
Resolved
PROVIDE SIX HAND FLARES AND SIX HAND SMOKES.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Fire Fighting
Issued 21 December 1989
Resolved
PROVE PROPER OPERATION OF FIXED FIRE FIGHTING SYSTEM FOR GALLEY RANGE.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Engineering
Issued 21 December 1989
Resolved
INSTALL METAL GUARD FOR STBD ENGINE RACOR FILTER.
Condition: Unknown
Due 21 December 1989
Resolved 21 December 1989
Lifesaving
Issued 24 February 1988
Resolved
PROVIDE 45 ADDITIONAL ADULT PFD'S.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Accommodation/Occupational Safety
Issued 24 February 1988
Resolved
SECURE GALLEY HOT BOX AGAINST MOVEMENT.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Documentation
Issued 24 February 1988
Resolved
PROVIDE "OIL DISCHARGE PROHIBITED" PLACARD IN ENGINEROOM.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Accommodation/Occupational Safety
Issued 24 February 1988
Resolved
PROVIDE SAFETY RAIL 6 INCHES HIGH AROUND GALLEY STOVE TOP.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Electrical
Issued 24 February 1988
Resolved
PROVIDE PROPER ELECTRICAL HAZARD TAG FOR PANEL BOARD IN GALLEY.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Navigation
Issued 24 February 1988
Resolved
DEMONSTRATE PROPER OPERATION OF STERN LIGHT.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Construction/Loadline
Issued 24 February 1988
Resolved
REMOVE CAULKING FROM AROUND SEAM IN TONNAGE OPENING AFT ON MAIN DECK.
Condition: Unknown
Due 24 February 1988
Resolved 24 February 1988
Navigation
Issued 6 November 1987
Resolved
PROVIDE MEANS TO OPERATE SHIP'S BELL FROM WHEELHOUSE OR HURRICANE DECK.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Fire Fighting
Issued 6 November 1987
Resolved
PROVIDE MANUFACTURER'S LABEL AFFIXED TO PORTABLE FIRE EXTINGUISHER IN GALLEY HOLD.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Engineering
Issued 6 November 1987
Resolved
PROVIDE FLAME SHIELD BENEATH STORAGE TANK FUEL LINE FILTER IN ENGINEROOM.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Fire Fighting
Issued 6 November 1987
Resolved
PROVIDE SPANNERS FOR HOSE FITTINGS AT ALL FIRE STATIONS.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Lifesaving
Issued 6 November 1987
Resolved
PROVIDE 6 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Lifesaving
Issued 6 November 1987
Resolved
PROVIDE OPERABLE WATER LIGHT FOR ONE RING BUOY.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Construction/Loadline
Issued 6 March 1987
Resolved
SUBMIT DRAWINGS SHOWING CHANGES TO VESSEL'S STRUCTURAL COMPONENTS, MACHINERY AND PIPING.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Engineering
Issued 6 March 1987
Resolved
PROPERLY INSULATE HORIZONTAL EXHAUST RUNS ON BRIDGE DECK PORT AND STARBOARD
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Accommodation/Occupational Safety
Issued 6 March 1987
Resolved
PROVE PROPER INSTALLATION OF MSD AS PER APPROVED PLANS.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Construction/Loadline
Issued 6 March 1987
Resolved
SUBMIT NEW STABILITY CALCULATIONS DUE TO CHANGE IN LOCATION OF SEWAGE HOLDING TANK.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Construction/Loadline
Issued 6 March 1987
Resolved
HAVE VESSEL RE-ADMEASURED DUE TO CHANGES IN VESSEL STRUCTURAL COMPONENTS.
Condition: Unknown
Due 6 March 1987
Resolved 6 March 1987
Electrical
Issued 31 July 1986
Resolved
PROVIDE PROPER SUPPORTS FOR VESSEL'S SHIPS SERVICE GERNERATOR (GENERATOR END).
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Electrical
Issued 31 July 1986
Resolved
PERMANENTLY REMOVE ALL MULTI BULB STRIP LIGHTS WHICH DO NOT HAVE UL APPROVAL FOR MARINE USE.
Condition: Unknown
Due 31 July 1986
Resolved 31 July 1986
Engineering
Issued 7 June 1986
Resolved
PUT ALL GAUGES IN WHEELHOUSE FOR ENGINE ROOM MACHINERY
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Construction/Loadline
Issued 7 June 1986
Resolved
PROVIDE GUARDS FOR HOT DECK AREA ON HURRICANE DECK ALONG RAIL.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Unknown
Issued 7 June 1986
Resolved
TAG ALL VALVES AND VENTS THROUGHOUT VESSEL
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Lifesaving
Issued 7 June 1986
Resolved
PROVIDE EXIT SIGNS FROM INTERIOR SPACES AS APPROPRIATE
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
MOUNT MAGNETIC CONTACTER FOR THE AIR HANDLERS IN A PROPER CABINET ON THE MAIN AND SALON DECK
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
INSTALL EMERGENCY LIGHTS IN ENGINE ROOM
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Fire Fighting
Issued 7 June 1986
Resolved
INSTALL APPROVED DAMPERS IN AIR INLETS AND OUTLETS ON AIR HANDLERS ON MAIN DECK AND SALON DECK
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Fire Fighting
Issued 7 June 1986
Resolved
PROPERLY LABEL ALL FIRE DAMPERS
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Fire Fighting
Issued 7 June 1986
Resolved
PROVE PROPER OPERATION OF FIRE DAMPERS
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
CORRECT FUEL LEAK ON FRONT OF STBD MAIN ENGINE AND #1 GENERATOR ENGINE.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
OVERSPEED MAIN ENGINES, GENERATOR ENGINES AND BOW THRUSTER ENGINE.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
LAG BOW THRUSTER ENGINE EXHAUST PIPE IN STBD VOID OF SUPPLY COMPARTMENT
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Documentation
Issued 7 June 1986
Resolved
OBTAIN AN FCC CERTIFICATE PRIOR TO ISSUING OF COI
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Fire Fighting
Issued 7 June 1986
Resolved
PROVIDE DOCUMENTATION THAT DECK CARPET AND ADHESIVE MEET STRUCTURAL FIRE PROTECTION STANDARDS.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
ALL INTERIOR LIGHTS (DECORATIVE) SHALL BE UL LISTED FOR MARINE USE OR SPECIFICALLY APPROVED BY THE COGNIZANT OCMI
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
PROVIDE A RUBBER MAT IN FRONT OF SWITCHBOARD
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
INSTALL PERMANENT EDUCTOR FAN IN STACK TO VENTILATE ENGINE EXHAUST TRUNKS
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
ADJUST MAIN ENGINE GOVERNOR PORT AND STB TO LIMIT ENGINE SPEED TO 1200RPM.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
POST WARNING SIGNS ON HOT EXHAUST TRUNK AT BASE OF STACK PORT AND STBD.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Navigation
Issued 7 June 1986
Resolved
ADJUST FOLLOW UP SYSTEM IN WHEELHOUSE SO ELECTRICAL CIRCUIT COINCIDES WITH MWCHANICAL STOPS ON HELM
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
PROVIDE AND TEST A 175PSI RELIEF VALVE ON THE CONTROL AIR RECEIVER.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Engineering
Issued 7 June 1986
Resolved
TEST OPERATION OF BILGE SUCTION IN SUPPLY ROOM BILGES
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
SUBMIT AS BUILT PLANS OF VESSEL'S ELECTRICAL SYSTEM TO MSO JACKSONVILLE FOR PLAN APPROVAL.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
PROVIDE A CIRCUIT DIRECTORY FOR EACH ELECTRICAL DISTRIBUTION PANEL.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
INSTALL PERMANENT ELECTRIC CABLE FOR EXHAUST STACK EDUCTOR FAN.
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
SECURE ALL GALLEY EQUIPMENT TO DECK OR BULKHEAD
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
TERMINATE ALL ELECTRICAL CABLES IN GALLEY
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
TERMINATE ALL ELECTRICAL CABLES IN THE AIR HANDLERS ON THE MAIN AND SALON DECK
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Lifesaving
Issued 7 June 1986
Resolved
REPAIR LIFEJACKET STORAGE BOXES TO PROVIDE WEATHERTIGHT ENCLOSURE
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Lifesaving
Issued 7 June 1986
Resolved
PROVIDE ADDITIONAL STORAGE FOR LIFEJACKETS TO RELIEVE PRESENT OVERPACKING OF BOXES
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
MAKE ALL STUFFING TUBES ON WEATHER DECK WEATHERTIGHT
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Electrical
Issued 7 June 1986
Resolved
INSTALL COVERS ON BATTERY BOXES IN ENGINE ROOM AND WHEELHOUSE
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Fire Fighting
Issued 7 June 1986
Resolved
MOUNT ALL PORTABLE FIRE EXTINGUISHERS AS REQUIRED
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Documentation
Issued 7 June 1986
Resolved
PROVIDE EVIDENCE OF ADMEASUREMENT AND DOCUMENTATION PRIOR TO RECEIVING COI
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986
Documentation
Issued 7 June 1986
Resolved
MARK VESSEL WITH OFFICIAL NUMBER AND TONNAGE
Condition: Unknown
Due 7 June 1986
Resolved 7 June 1986