Records from 1986 to 2001. Most recent: inspection, 3 October 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
3 October 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 294707
5 October 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433464
2 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 429836
6 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 417743
22 May 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 403769
20 March 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 389300
16 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 376280
15 March 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 376211
14 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 714123
1 March 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 375505
12 December 1991
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1263642
6 August 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317878
6 August 1987
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1029786
7 June 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 309517
7 June 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1303953
Fire Fighting
Issued 3 October 2001
No resolution recorded
PROVIDE PERMINANT REPAIRS TO SHIPS FIREMAN IN WAY OF AFT CARGO DECK DURING SHIPS DRYDOCKING IN ACCORDANCE WITH SOLAS REGULATION 4 CHAPTER II-2.
Condition: Unknown
Due 3 October 2002 — due date passed with no resolution recorded
Navigation
Issued 3 October 2001
No resolution recorded
PROVIDE PERMENANT REPAIRS TO SHIPS STEERING AUXILIARY TANK IN WAY OF STEERING COMPARTMENT IN ACCORDANCE WITH REGULATION 29 CHAPTER II-1
Condition: Unknown
Due 3 October 2002 — due date passed with no resolution recorded
Deck/Cargo
Issued 2 June 1999
Resolved
PRIOR TO NEXT U.S. PORT, DEMONSTRATE PROPER OPERATION OF OIL DISCHARGE MONITORING EQUIPMENT INCLUDING ALL REQUIRED ALARM CONDITIONS TO SATISFACTION OF CLASSIFICATION SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Deck/Cargo
Issued 2 June 1999
Resolved
PRIOR TO NEXT U.S. PORT, DEMONSTRATE ALL REQUIRED INERT GAS SYSTEM BLOWER SHUTDOWNS AND PRODUCTION OF INERT GAS SAMPLE TO SATISFACTION OF CLASSIFICATION SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Documentation
Issued 2 June 1999
Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE RECORD OF CONTINIOUS PROFICENCY FOR [name withheld] U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Navigation
Issued 20 March 1996
Resolved
PROVIDE USCG WITH PROOF FROM CLASS SOCIETY THAT VESSEL COMPLIES WITH SOLAS CHAPTER II-I, PARAGRAPH 8.4 OF REGULATION 29 (AS PER REG. 29, PARAGRAPH 19.1) PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Construction/Loadline
Issued 1 March 1995
Resolved
VESSEL NOT FITTED WITH MECHANICAL DECK SCUPPERS. VESSEL USING RAGS AND CONCRETE TO PLUG SCUPPERS.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Deck/Cargo
Issued 1 March 1995
Resolved
CARGO PUMP SHAFT GAS TIGHT SEALS BETWEEN THE MACHINERY SPACE AND THE CARGO PUMP ROOM WERE FOUND TO BE LEAKING OIL. CLASS SOCIETY ISSUED CONDITION OF CLASS BASED UPON TEMPORARY REPAIR. PERMANENT REPAIRS TO BE MADE PRIOR TO RETURN TO U.S. WATERS AND CONDITION OF CLASS PROVIDED ATTESTING TO REPAIR
Condition: Unknown
Due 5 March 1995
Resolved 16 March 1995
Electrical
Issued 1 March 1995
Resolved
MAIN S/S GENERATOR SWITCH BOARDS MISSING/DAMAGED INSULTATION ON THE SAFETY HANDRAILS. RENEW/REPAIR AS NEEDED ALL SAFETY HANDRAIL INSULATION. SEE SOLAS 60 CHAP.II PART C REG. 27(ii)
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 1 March 1995
Resolved
FOAM LINE DRESSER COUPLING LOCATED AFT OF THE MIDSHIPS MANIFOLD, LEAKING.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Documentation
Issued 1 March 1995
Resolved
OWNERS TO PROVIDE CLASS SOCIETY "CONDITION OF CLASS" ATTESTING TO THE SAT. REPAIRS AND TESTING OF ALL VERTICAL GAS TIGHT SHAFT SEALS LOCATED IN THE BLKHD. BETWEEN THE MACH. SPACE AND THE CARGO PUMPROOM PRIOR TO THE VESSELS RETURN TO U.S. WATERS.
Condition: Unknown
Due 5 March 1995
Resolved 16 March 1995
Deck/Cargo
Issued 6 August 1987
Resolved
46 CFR 32.53-45 (A) MAKE PERMANENT REPAIRS TO INERT GAS AUXILLARY BLOWER, AS REQUIRED.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995