MAURY USCG vessel records Sign in
← All vessels

ANCONA

ANCONA is a 1978 tank ship. The Coast Guard has recorded 15 inspections since 1986, most recently in October 2001, along with 12 deficiencies — 2 with no resolution recorded —.

Records from 1986 to 2001. Most recent: inspection, 3 October 2001.

Built
1978
Last inspected
3 October 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7342809 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
268217
Flag
NORWAY
—
Maury page id
psix-268217

Inspections, by type

…with no type recorded13
…past their stated due date2
Years with a record 9 calendar years (1986–2001)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it129576 - Convention (Subpart B), Gross Ton
125725 - Regulatory (Subpart C or D), Gross Ton
103268 - Convention (Subpart B), Net Ton
110197 - Regulatory (Subpart C or D), Net Ton
267401 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

3 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 294707
5 October 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433464
2 June 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 429836
6 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 417743
22 May 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 403769
20 March 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 389300
16 March 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 376280
15 March 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 376211
14 March 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 714123
1 March 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 375505
12 December 1991 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1263642
6 August 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317878
6 August 1987 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1029786
7 June 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 309517
7 June 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1303953

Deficiency record · 12

Fire Fighting
Issued 3 October 2001 No resolution recorded
PROVIDE PERMINANT REPAIRS TO SHIPS FIREMAN IN WAY OF AFT CARGO DECK DURING SHIPS DRYDOCKING IN ACCORDANCE WITH SOLAS REGULATION 4 CHAPTER II-2.
Condition: Unknown
Due 3 October 2002 — due date passed with no resolution recorded
Navigation
Issued 3 October 2001 No resolution recorded
PROVIDE PERMENANT REPAIRS TO SHIPS STEERING AUXILIARY TANK IN WAY OF STEERING COMPARTMENT IN ACCORDANCE WITH REGULATION 29 CHAPTER II-1
Condition: Unknown
Due 3 October 2002 — due date passed with no resolution recorded
Deck/Cargo
Issued 2 June 1999 Resolved
PRIOR TO NEXT U.S. PORT, DEMONSTRATE PROPER OPERATION OF OIL DISCHARGE MONITORING EQUIPMENT INCLUDING ALL REQUIRED ALARM CONDITIONS TO SATISFACTION OF CLASSIFICATION SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Deck/Cargo
Issued 2 June 1999 Resolved
PRIOR TO NEXT U.S. PORT, DEMONSTRATE ALL REQUIRED INERT GAS SYSTEM BLOWER SHUTDOWNS AND PRODUCTION OF INERT GAS SAMPLE TO SATISFACTION OF CLASSIFICATION SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Documentation
Issued 2 June 1999 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE RECORD OF CONTINIOUS PROFICENCY FOR [name withheld] U.S. COAST GUARD.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Navigation
Issued 20 March 1996 Resolved
PROVIDE USCG WITH PROOF FROM CLASS SOCIETY THAT VESSEL COMPLIES WITH SOLAS CHAPTER II-I, PARAGRAPH 8.4 OF REGULATION 29 (AS PER REG. 29, PARAGRAPH 19.1) PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Construction/Loadline
Issued 1 March 1995 Resolved
VESSEL NOT FITTED WITH MECHANICAL DECK SCUPPERS. VESSEL USING RAGS AND CONCRETE TO PLUG SCUPPERS.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Deck/Cargo
Issued 1 March 1995 Resolved
CARGO PUMP SHAFT GAS TIGHT SEALS BETWEEN THE MACHINERY SPACE AND THE CARGO PUMP ROOM WERE FOUND TO BE LEAKING OIL. CLASS SOCIETY ISSUED CONDITION OF CLASS BASED UPON TEMPORARY REPAIR. PERMANENT REPAIRS TO BE MADE PRIOR TO RETURN TO U.S. WATERS AND CONDITION OF CLASS PROVIDED ATTESTING TO REPAIR
Condition: Unknown
Due 5 March 1995
Resolved 16 March 1995
Electrical
Issued 1 March 1995 Resolved
MAIN S/S GENERATOR SWITCH BOARDS MISSING/DAMAGED INSULTATION ON THE SAFETY HANDRAILS. RENEW/REPAIR AS NEEDED ALL SAFETY HANDRAIL INSULATION. SEE SOLAS 60 CHAP.II PART C REG. 27(ii)
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Fire Fighting
Issued 1 March 1995 Resolved
FOAM LINE DRESSER COUPLING LOCATED AFT OF THE MIDSHIPS MANIFOLD, LEAKING.
Condition: Unknown
Due 22 March 1996
Resolved 22 March 1996
Documentation
Issued 1 March 1995 Resolved
OWNERS TO PROVIDE CLASS SOCIETY "CONDITION OF CLASS" ATTESTING TO THE SAT. REPAIRS AND TESTING OF ALL VERTICAL GAS TIGHT SHAFT SEALS LOCATED IN THE BLKHD. BETWEEN THE MACH. SPACE AND THE CARGO PUMPROOM PRIOR TO THE VESSELS RETURN TO U.S. WATERS.
Condition: Unknown
Due 5 March 1995
Resolved 16 March 1995
Deck/Cargo
Issued 6 August 1987 Resolved
46 CFR 32.53-45 (A) MAKE PERMANENT REPAIRS TO INERT GAS AUXILLARY BLOWER, AS REQUIRED.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.