← All vessels
FIONA 7
FIONA 7 is a 1985 freight ship. The Coast Guard has recorded 22 inspections since 1986, most recently in April 2005, along with 12 deficiencies and 5 operational controls.
Records from 1986 to 2005. Most recent: operational control imposed, 2 April 2005.
- Built
- 1985
- Last inspected
- 2 April 2005
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8314639 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FFD9
268369
Flag
PANAMA
—
Maury page id
psix-268369
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it15893 - Convention (Subpart B), Gross Ton
8092 - Convention (Subpart B), Net Ton
17850 - Dead Weight, Ton
26770 - Displacement, Ton
8092 - Convention (Subpart B), Net Ton
17850 - Dead Weight, Ton
26770 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
2 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2325002
23 March 2005
MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2316713
6 January 2005
PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2270262
19 October 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2224107
5 October 2004
ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2213924
28 May 2004
MTSA/ISPS Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2080710
23 April 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2051466
7 January 2004
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1977523
26 December 2003
MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1969696
24 July 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280295
24 February 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 275577
15 June 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 429711
24 November 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 422845
15 May 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415885
11 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403568
20 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 398577
13 June 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 392288
8 April 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 389839
2 December 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 373002
13 February 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 341980
18 July 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 331478
19 June 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309568
Deficiency record · 12
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 January 2005
Resolved
Fire control plan is missing: 1. IMO symbols for fire plan in at least two locations 2. Indication of automatic closing doors. 3. Indications of classification of doors. ***USCG inspector identified Class "A" boundaries as difficult to understand, this may have caused by black and white copies posted. Recommend color copies posted. Ensure corrections to fire plan are recorded.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 6 January 2005
Resolved
Fire flap in stack is frozen and will not close.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 October 2004
Resolved
Handrails on main deck severely corroded or missing. Repair (replace as necessary) prior to 13Nov04
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 5 October 2004
Resolved
Fire Control Plan does not clearly show "A" Class boundary Divisions & means of access to various compartments. Correct by 13Nov04
Stability › Watertight Integrity › Weathertight Enclosure
Issued 5 October 2004
Resolved
Main deck Port & STBD doors to superstructure are unable to seal. Correct prior to departure from Tampa
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 5 October 2004
Resolved
Insure all Fuel oil vents have proporly Installed Flame Screens Before 13Nov04
Deck/Cargo › Holds/Tanks › Ventilation Air Intake
Issued 5 October 2004
Resolved
Insure all Ventilation closures have properly installed gaskets Prior to 13Nov04
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 5 October 2004
Resolved
Insure all lighting & junction boxes in the Pipe Tunnel & Access are free of Electrical Shock Hazzards by 13 Nov04
Documentation
Issued 13 June 1996
Resolved
Invalid Certificate of Financial Responsibility.
Documentation
Issued 13 June 1996
Resolved
Update all Vessel's Certificates according to Class (BV).
Accommodation/Occupational Safety
Issued 8 April 1996
Resolved
REPLACE BROKEN AND MISSING LIGHT COVERS THROUGH OUT ENGINE ROOM.
Engineering
Issued 8 April 1996
Resolved
PROVIDE SATISFACTORY CLASS SOCIETY REPORT ATTESTING TO THE CONDITION OF THE#5 PORT HIGH PRESSURE FUEL PUMP FOR THE MAIN ENGINE. SOLAS
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.