MAURY USCG vessel records Sign in
← All vessels

TAKIS

TAKIS is a 1985 tank ship. The Coast Guard has recorded 6 inspections since 2001, most recently in December 2003, along with 9 deficiencies and 1 operational control.

Records from 2001 to 2003. Most recent: inspection, 30 December 2003.

Built
1985
Last inspected
30 December 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8505135 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PANAMA
—
Maury page id
psix-26852

Inspections, by type

…with no type recorded2
Years with a record 2 calendar years (2001–2003)
The 6 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8667 - Dead Weight, Ton
4925 - Regulatory (Subpart C or D), Gross Ton
2996 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 6

30 December 2003 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1971352
18 November 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1949819
27 August 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1897696
25 August 2003 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1886314
9 May 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 290692
9 May 2001 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1069516

Deficiency record · 9

Documentation › Certificates/Documents
Issued 30 December 2003 Resolved
Document expired. LEGACY COMPONENT DESC: Classification Document
Due 30 December 2003
Resolved 30 December 2003
Resolution: Received updated document via fax from agent.
Documentation › Certificates/Documents › International Load Line Certificate
Issued 30 December 2003 Resolved
Document expired.
Due 30 December 2003
Resolved 30 December 2003
Resolution: Received updated document via fax from agent.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 30 December 2003 Resolved
Document expired.
Due 30 December 2003
Resolved 30 December 2003
Resolution: Received updated document via fax from agent.
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 30 December 2003 Resolved
Document expired.
Due 30 December 2003
Resolved 30 December 2003
Resolution: Received updated document via fax from agent.
Documentation › Certificates/Documents › IOPP Certificate
Issued 30 December 2003 Resolved
Document expired.
Due 30 December 2003
Resolved 30 December 2003
Resolution: Received updated document via fax from agent.
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 30 December 2003 Resolved
Document not in MISLE.
Due 30 December 2003
Resolved 30 December 2003
Resolution: Received document via fax from agent.
Deck/Cargo › Holds/Tanks
Issued 25 August 2003 Resolved
HIGH LEVEL ALARMS NOT OPERATING CORRECTLY. LEGACY COMPONENT DESC: Tank Level Monitoring Device
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2003
Resolved 26 August 2003
Resolution: RECEIVED CLASS REPORT FROM NKK ATTESTING TO THE REPAIR AND PROPER OPERATION OF CARGO TANK HIGH LEVEL ALARMS. DEFICIENCY CLEARED.
Deck/Cargo › Holds/Tanks
Issued 25 August 2003 Resolved
CLOSING DEVICES ON DECK SAMPLE LOCK MISSING COMPONETS ON DOOR SIDE. LEGACY COMPONENT DESC: Scuttle
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 25 September 2003
Resolved 26 August 2003
Resolution: RECEIVED CLASS REPORT FROM NKK ATTESTING TO THE REPAIR OF CARGO SAMPLE DECK LOCKER DOOR LOCK. DEFICIENCY CLEARED.
Operations/Management › Lifesaving
Issued 25 August 2003 Resolved
SOLAS TRAINING MANUAL NOT UPDATED TO INCLUDE LIFEBOAT LAUNCHING INSTRUCTIONS, EPRIB, SARTS. ETC. PAGES ARE MARKED TO INSERT MANUFACTURES INSTRUCTIONS. INSTRUCTIONS NOT ENTERED. SOLAS 74(A) III/35 LEGACY COMPONENT DESC: Op Readiness/Maintenance/Inspection
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 25 September 2003
Resolved 5 November 2003
Resolution: Received fax from vessels master stating the training manual has been updated to include lifeboat-launching instructions, EPIRB, SARTS, and other manufactures instructions.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.