MAURY USCG vessel records Sign in
← All vessels

MASCO VIII

MASCO VIII is a 1986 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1986, most recently in February 2018, along with 65 deficiencies.

Records from 1986 to 2018. Most recent: inspection, 26 February 2018.

Built
1986
Last inspected
26 February 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTZ5818
268587
Flag
PANAMA
367060790 (licence lapsed)
Maury page id
psix-268587

Inspections, by type

…with no type recorded3
Years with a record 27 calendar years (1986–2018)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WTZ5818MMSI 367060790 · expired · compulsorily equipped · granted 12 February 2016, cancelled 16 May 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

26 February 2018 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6361849
26 May 2016 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5892400
19 May 2016 Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5881410
22 May 2014 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4864316
16 May 2014 Hull Examination · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4860397
25 June 2012 Annual Inspection · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4356666
22 May 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4317420
24 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4125211
12 August 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3340125
3 June 2008 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3225917
30 January 2008 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3144302
12 June 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2677923
22 May 2006 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2656142
26 May 2005 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2368566
7 June 2004 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2091586
16 September 2003 Deficiency Check
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1906005
20 August 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1882108
11 June 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1815159
6 March 2003 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1753620
4 March 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1814801
12 July 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1671187
12 June 2002 Hull Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1602686
26 July 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431083
30 May 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469624
24 June 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1450306
24 July 1998 Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795923
1 June 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436096
27 May 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414810
24 May 1996 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1454340
19 May 1995 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1438334
18 May 1994 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 869426
5 August 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 846656
13 May 1993 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143814
13 May 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 944361
12 May 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 956919
10 May 1991 COI Inspection · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212500
2 January 1991 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 931537
21 August 1990 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217843
2 February 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 906893
3 April 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1043313
1 February 1989 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1209356
28 January 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321726
21 August 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315552
26 January 1987 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1009637
25 April 1986 Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993871

Deficiency record · 65

Electrical › Electric Supply System (service) › Cable
Issued 26 May 2016 Resolved
Remove unecessary wiring thorughout vessel and secure all dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 27 May 2016
Resolution: Vessel owner made appropriate corrective action, securing dead end wires and removing wires not in service.
Engineering › Pressure Vessel › Maximum Allowable Working Pressure
Issued 22 May 2014 Resolved
Air receiver in engine room had substantial corrosion beneath information plate. MAster was instructed to hydrostatically test the vessel IAW 46 CFR 61.10-5 or to replace the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 May 2014
Resolution: Vessel submitted paperwork for successful hydrostatic test of pressure vessel.
Lifesaving › Lifefloat › Painter
Issued 22 May 2014 Resolved
Painters connecting the three life floats were not connected to one another. Instructed master to connect life floats together in daisy chain IAW 46 CFR 180.137.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2014
Resolution: Deckhand was in process of splicing line around when inspector departed, received email verification of completed repair prior to returning to office.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 22 May 2014 Resolved
Vessel did not have EPA VGP. Instructed master to apply for NOI.
Due 22 June 2014
Resolved 16 June 2014
Resolution: Master provided proof of EPA VGP NOI submission via email.
Documentation › Certificates/Documents › Stability Letter
Issued 25 June 2012 Resolved
Vessel does not comply with AAWPP IAW Policy Letter 11-03. Utilized Weight Ratio Method based on stability letter SER H2-6241S. (Max. 40 Persons x 160 lbs) / 185 lbs = 34 persons; 30 passengers and 4 crew members. Reduced total number of persons allowed onboard.
Due 10 July 2012
Resolved 10 July 2012
Resolution: See request in documents, notified vsl rep to submit request to MSC. Vsl meets subchapter "S" requirements.
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 25 June 2012 Resolved
C/R flat bar on P/S weather tight door near operating station. Bottom flat bar is deteriorated and is door is not weather tight.
Due 10 July 2012
Resolved 10 July 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 June 2012 Resolved
Place two blanks in breaker panel under operating station console.
Due 10 July 2012
Resolved 10 July 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 25 June 2012 Resolved
Provide a service report for low fuel pressure switch on P/S MDE. Electrical connection was not connected. Crew stated it was disconnected due to multiple false readings.
Due 10 July 2012
Resolved 10 July 2012
Construction/Loadline › Hull › Bottom Plating
Issued 22 May 2012 Resolved
Approx. 18" x 18" insert required due to sharp inset in bottom at port stern corner
Action required: 705 - Other - as specified
Resolved 24 May 2012
Resolution: Witnessed dye penetrant test of insert. Test sat.
Construction/Loadline › Structures › Deck Plating
Issued 22 May 2012 Resolved
Stbd stern corner deck insert approx. 4' x 4' and reinstall manhole cover
Action required: 705 - Other - as specified
Resolved 24 May 2012
Resolution: New deck plate and manhole cover installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 8 June 2006 Resolved
Properly secure all cables and wiring on the mast and pilot house top.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 8 June 2006
Resolution: strapped with metal straps.
Fire Fighting › Fire Hoses › Condition
Issued 8 June 2006 Resolved
Prior to sailing replace the port fire hose.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: replaced with new hose.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 June 2006 Resolved
Prior to sailing replace the cracked strobe light for the upper life float.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: new light installed.
Construction/Loadline › Structures › Scuttle
Issued 8 June 2006 Resolved
prior to sailing demonstrate proper operation of the emegency escape cover for the lower 10 man berthing area.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: maintenance performed, demonstrated removal.
Engineering › Fuel Oil Service System › Hose
Issued 8 June 2006 Resolved
Prior to sailing install a new fuel oil supply hose onto the starboard generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: New hose installed.
Engineering › Bilge Water Management System › Piping
Issued 8 June 2006 Resolved
Prior to sailing, complete repairs and demonstrate proper operation of the lazarette bilge suction.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: Missing weld repaired and proper operation demonstrated.
Construction/Loadline › Structures › Door
Issued 8 June 2006 Resolved
Provide dogging wrenches for all watertight doors.
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 8 June 2006
Resolution: Provided.
Communications › Alarms/Indicators › Fire Alarm
Issued 8 June 2006 Resolved
Repair or replace the smoke detector in the galley and install batteries in all other detector units.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2006
Resolved 8 June 2006
Resolution: Corrected.
Engineering › Steering Gear System › Pin
Issued 8 June 2006 Resolved
Prior to sailing install retaining pins in all steering connections of the tiller arms and jockey bar.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: Installed.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 8 June 2006 Resolved
Prior to sailing install a locking device for the sewage tank discharge valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: Installed.
Construction/Loadline › Structures › Manhole
Issued 8 June 2006 Resolved
Prior to sailing complete welding of the new manhole cover for the lazarette.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 8 June 2006
Resolved 8 June 2006
Resolution: Completed.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 8 June 2006 Resolved
Properly label the pilot house engine emergency shutdowns
Action required: 705 - Other - as specified
Due 8 July 2006
Resolved 8 June 2006
Resolution: Done.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 26 May 2005 Resolved
Install missing cover on the 12 volt electrical junction box under the pilot house console.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: installed.
Engineering › Fuel Oil Service System › Piping
Issued 26 May 2005 Resolved
Repair fuel oil leak at the shut-off valve for the port generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: corrected.
Construction/Loadline › Hull › Bottom Plating
Issued 26 May 2005 Resolved
Properly weld all rudder compartment transverse bottom angles at the slotted connections of the longitudinal bottom girders, port and starboard sides.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2005
Resolved 26 May 2005
Resolution: welded.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 May 2005 Resolved
Properly service the paint locker CO2 fire extinguisher, or remove all paint.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2005
Resolved 26 May 2005
Resolution: Replaced.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 26 May 2005 Resolved
Repair or replace the fire pump, due to excessive leaks at the impeller shaft seal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2005
Resolved 1 June 2005
Resolution: repaired and tested.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 May 2005 Resolved
Properly repair the starboard fuel oil day tank emergency shut-off reach rod.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2005
Resolved 26 May 2005
Resolution: repaired and tested.
Engineering › Fuel Oil Service System › Valve, Control
Issued 26 May 2005 Resolved
Properly label the emergency cut-off reach rod.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: labelling completed.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 May 2005 Resolved
Provide and install fixture covers on all lighting fixtures in the engine room and the generator room as required by 46 CFR 183.410 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 26 June 2005
Resolved 8 June 2006
Resolution: installed. See activity 2656142
Electrical › Electrical Distribution System (service) › Cable
Issued 26 May 2005 Resolved
Properly install and seal the 220 volt power supply cable leading from the main switch board to the generator room 220 volt power panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: installation corrected and properly sealed.
Construction/Loadline › Structures › Door
Issued 26 May 2005 Resolved
repair and properly label the watertight door open indicator panel in the pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: done.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 26 May 2005 Resolved
Properly secure the clothes dryer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: secured.
Engineering › Steering Gear System › Rudder
Issued 26 May 2005 Resolved
Renew bearing to starboard rudder assembly to the satisfaction of the attending marine inspector as per 46 CFR 182.600.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2006
Resolved 8 June 2006
Resolution: Replaced during drydock. See activity 2656142
Electrical › Lighting (service) › Lighting Fixture
Issued 26 May 2005 Resolved
Provide and install the protective cover on the lighting fixture over the air conditioning unit under the pilothouse deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 26 May 2005
Resolution: installed.
Engineering › Bilge Water Management System › Interface Detector
Issued 17 June 2004 Resolved
Label bilge alarm panel on the bridge as required by 46 CFR 182.530(c).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 17 June 2004
Resolution: Inspected the satisfactory labeling on bilge alarm panel.
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 17 June 2004 Resolved
Repair hydraulic leak on port main diesel engine reduction gear supply flexible non-metallic hose.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 17 June 2004
Resolution: Vessel representative installed new hydraulic hose.
Construction/Loadline › Hull › Bottom Plating
Issued 7 June 2004 Resolved
Crop and renew two 3ft x 3ft areas of engine room bottom plate on the port and starboard sides of the CVK in way of the forward bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 10 June 2004
Resolution: plate properly inserted and tested.
Construction/Loadline › Hull › Bottom Plating
Issued 7 June 2004 Resolved
Crop and renew 4ft x 4ft section of engine room bottom plate below the air receiver compressors where slug welded over hole.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 10 June 2004
Resolution: Bottom plate properly inserted and tested.
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 June 2004 Resolved
Crop and renew port forward fuel oil tank deck vent where holed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 17 June 2004
Resolution: Piping cropped to approximately 3 inches above the main deck and new vent piping installed.
Engineering › Bilge Water Management System › Piping
Issued 7 June 2004 Resolved
Crop and renew bilge suction line and bilge manifold piping for engine room suction line.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 10 June 2004
Resolution: Piping renewed.
Construction/Loadline › Hull › Hull Plating
Issued 7 June 2004 Resolved
Crop and renew the main deck plating at the port and starboard stern corners due to severe insets. Each insert is approximately 18" x 36".
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 10 June 2004
Resolution: Inserted.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 7 June 2004 Resolved
Pull and replace the starboard cutlass bearing due to wear.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 10 June 2004
Resolution: Replaced.
Construction/Loadline › Hull › Hull Plating
Issued 7 June 2004 Resolved
Clad weld area of pitting at side shell to chine bar connection at the starboard forward fuel oil tank.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 June 2004
Resolved 10 June 2004
Resolution: Clad welded.
Navigation › Piloting/Steering
Issued 21 August 2003 Resolved
Provide Tidal Current Tables for the Vessel. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 16 September 2003
Resolution: Procured Tidal Current Table book.
Navigation › Piloting/Steering
Issued 21 August 2003 Resolved
Prove charts are being corrected. LEGACY COMPONENT DESC: Local Notices to Mariners
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 16 September 2003
Resolution: Corrected charts for local area.
Electrical › Lighting (emergency)
Issued 21 August 2003 Resolved
Hard wire emergency lights in the engine room. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 16 September 2003
Resolution: Properly hard wired lights into outlet.
Operations/Management › Drug and Alcohol Testing
Issued 12 June 2002 Resolved
Provide proof of random drug testing as required by 46 CFR part 16. LEGACY COMPONENT DESC: Testing, Random
Due 12 July 2002
Resolved 12 July 2002
Resolution: Proof of drug testing provided to the CG Inspector.
Engineering › Shafting/Propeller Arrangements
Issued 30 May 2002 Resolved
Replace port and starboard cutless bearings. LEGACY COMPONENT DESC: Bearing
Due 30 June 2002
Resolved 12 June 2002
Resolution: Replaced bearings with new ones.
Construction/Loadline › Hull › Side Shell
Issued 30 May 2002 Resolved
Weld insert approximately 2' x 3' starboard side aft in way of steering compartment.
Condition: Damaged By Earlier Event
Due 30 June 2002
Resolved 7 June 2002
Resolution: Crop and renewed damaged shell plating using 7-68 NVIC inspection and repair of steel hulls as a guide.
Construction/Loadline › Penetrations
Issued 30 May 2002 Resolved
Replace port and starboard overboard discharge valves on main diesel engines. LEGACY COMPONENT DESC: Sea Valves
Due 30 June 2002
Resolved 12 June 2002
Resolution: Valves replaced with new gate valves.
Engineering › Shafting/Propeller Arrangements
Issued 30 May 2002 Resolved
Make shaft keyways ready for inspection. LEGACY COMPONENT DESC: Propeller Shaft
Due 30 June 2002
Resolved 12 June 2002
Resolution: Propellers removed and keyways ready for inspection.
Deck/Cargo › Ballast
Issued 30 May 2002 Resolved
Repair or replace ladder rung in #2 port ballast tank. LEGACY COMPONENT DESC: Tank ladder
Due 30 June 2002
Resolved 12 June 2002
Resolution: Removed ladder and replaced wasted ladder rung.
Deck/Cargo › Holds/Tanks
Issued 30 May 2002 Resolved
Repair or replace ladder rungs in aft steering compartment. LEGACY COMPONENT DESC: Ladder
Due 30 June 2002
Resolved 12 June 2002
Resolution: Removed and replaced damaged ladder rungs.
Navigation
Issued 24 June 1999 Resolved
VESSELS STEERING SYSTEM IS UNSATISFACTORY. THE ENTIRE STEERING LINKAGE IS BINDING, MISSING RUDDER STOPS, PULLING HOSES AND MISSING BUSHINGS FOR JOCKEY BAR. VESSEL IS IN A NO-SAIL STATUS UNTIL THIS ITEM CLEARED.
Condition: Unknown
Due 25 June 1999
Resolved 25 June 1999
Electrical
Issued 19 May 1995 Resolved
PROVIDE GUARD FOR GENERATOR PULLEY.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 19 May 1995 Resolved
PROVIDE DEVIATION TABLE FOR VESSEL.
Condition: Unknown
Due 19 May 1995
Resolved 19 May 1995
Navigation
Issued 18 May 1994 Resolved
PROVIDE ADDITIONAL VHF-FM RADIO AND PROVE ITS OPERATION TO THE SATISFACTIONOF THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 18 May 1994
Resolved 18 May 1994
Documentation
Issued 13 May 1993 Resolved
PROVIDE ON BOARD VESSEL A CURRENT FCC SAFETY CERTIFICATE
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Engineering
Issued 10 May 1991 Resolved
MAKE VESSEL'S ENGINE ROOM AIR RECEIVER AVAILABLE FOR INTERNAL EXAM OR A_x001C_ -1.5- MAWP HYDROSTATIC TEST. PROVE SATISFACTORY OPERATION OF RELIEF VALVE.
Condition: Unknown
Due 10 May 1991
Resolved 10 May 1991
Electrical
Issued 2 January 1991 Resolved
PROVIDE SUITABLE LIGHT COVERS FOR PASSENGER/CREW QUARTERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 January 1991
Resolved 2 January 1991
Deck/Cargo
Issued 2 January 1991 Resolved
PROVIDE PROTECTIVE GUARD FOR ANCHOR WINCH FAN BLADES ON FOCSLE.
Condition: Unknown
Due 2 January 1991
Resolved 2 January 1991
Engineering
Issued 2 February 1990 Resolved
PROVIDE DRIP PANS FOR RAYCOR FUEL FILTERS.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Navigation
Issued 1 February 1989 Resolved
RENEW WORN PORT JOCKEY BAR PIN IN AFTER STEERING LINKAGE.
Condition: Unknown
Due 1 February 1989
Resolved 1 February 1989
Documentation
Issued 26 January 1987 Resolved
PROVIDE A SAFETY RADIOTELEPHONY CERTIFICATE(FCC) ONBOARD THE VESSEL.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.