Records from 2010 to 2026. Most recent: inspection, 9 April 2026.
Inspection history · 21
9 April 2026
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8345247
4 November 2025
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8264818
21 October 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8257779
8 September 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8229270
28 May 2025
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8133553
23 October 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8022253
9 September 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8012020
22 May 2024
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7917247
12 October 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7807391
16 May 2023
Annual Inspection · DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7689972
19 July 2022
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7510359
10 May 2021
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7189977
9 November 2020
Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7090241
27 May 2020
Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6961926
10 June 2019
Annual Inspection · DAPI Audit · Security Plan Review - ASP · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6710023
2 May 2018
Administrative Inspection · Deficiency Check · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6404190
27 June 2017
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6188777
8 May 2017
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6141709
12 July 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5938057
14 April 2016
MTSA Verification · COI Inspection · Administrative Inspection · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5854121
26 February 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5822880
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023
Resolved
Exhaust gas must not leak from the piping or any connections. The Port generator had an exhaust leak near the muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 20 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022
Resolved
Repair diesel fuel leak from day tank in port generator room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 21 July 2022
Resolution: fixed diesel leak, replaced elbow in piping.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 July 2022
Resolved
Replace the missing insulation from above the port main engine to maintain the fire control boundary in accordance with the vessels Fire Safety Plan.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 28 July 2022
Resolution: replaced insulation
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 July 2022
Resolved
Replace temporary patch on water line in tool room with a permanent repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 28 July 2022
Resolution: replaced rubber connection with metal connection
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Replace expired components of first aid kit and have all required equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 28 July 2022
Resolution: replaced expired first aid kit equipment
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
02 Child life jackets need new retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel replaced life jackets
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2021
Resolved
02 emergency lights not fully operational. replace or repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel replaced both emergency lights
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
replace first aid kit with non expired equipment
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2021
Resolved
Secure CO2 and helium cylinders.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel secured all gas cylinders
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020
Resolved
Destroy and replace 13 child life jackets and 1 kapok vest type life jacket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2020
Resolved 27 May 2020
Resolution: replaced prior to completion of inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020
Resolved
Replace reflective tape on 20 identified adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: tape replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2020
Resolved
Repair lagging around muffler and exhaust for heat protection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: lagging patched
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 May 2020
Resolved
Repair A/C leak in crew state room,
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 15 June 2020
Resolution: repaired
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 27 May 2020
Resolved
Repair emergency light in gift shop for proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 May 2020
Resolved
Relabel markings on PFD stowage compartment on bridge seats to state 51 Adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 15 June 2020
Resolution: relabled
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 May 2018
Resolved
1. Replace or make permanent repairs to the Port Main Engine exhaust flexible pipe joint, pipe has an exhaust leak
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: Replaced Port Main Engine exhaust flexible pipe joint, engine was ran, No leaks present
Stability › Watertight Integrity › General
Issued 2 May 2018
Resolved
Make Repairs to the Starboard side Maindeck Generator Rooms WTD dog
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: Starboard side Maindeck Generator Rooms WTD dog was loose, tightened the packing nut, door is back in full operation
Electrical › Lighting (service) › Outlet Box
Issued 8 May 2017
Resolved
Broken cover.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Replaced cover
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017
Resolved
Battery dead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Replaced battery
Documentation › Certificates/Documents › Stability Letter
Issued 2 May 2016
Resolved
Vessel does not have the most current stability letter posted at the operating station in accordance with 46CFR115.306. Vessel has 7 days to post the most current stability letter to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel does have the most current stability letter posted at the operating station in accordance with 46CFR115.306.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 May 2016
Resolved
Vessel steering system has a damaged hydraulic hose on the port side which has been determined by the marine inspector as not in suitable condition for the service it is intended for in accordance with 46CFR122.320. Vessel has 7 days to replace the hose to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel steering system damaged hydraulic hose on the port side has been replaced and it is in suitable condition for the service it is intended for in accordance with 46CFR122.320.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2016
Resolved
Vessel's 3 life rings have severely dry rotted line which has been determined by the marine inspector to not be in serviceable condition in accordance with 46CFR117.70. Vessel has 7 days to replace the the line or life rings to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Onsite Verification
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2016
Resolved
Vessel has a damaged light fixture in bow thruster compartment. Vessel has 7 days to make repairs in accordance with 46CFR120.410 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 11 May 2016
Resolution: Vessels damaged light fixture in bow thruster compartment has been replaced and repairs are in accordance with 46CFR120.410 to the satisfaction of the attending marine
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 May 2016
Resolved
Vessel has excessive hydraulic oil in bow thruster compartment which has been determined by the marine inspector as an unsafe condition in accordance with 46CFR176.830(b). Vessel has 7 days to remove hydraulic oil from compartment to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessels excessive hydraulic oil in bow thruster compartment has been removed.