MAURY USCG vessel records
← All vessels

CELEBRATION BELLE

CELEBRATION BELLE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in April 2026, along with 24 deficiencies and 2 casualty investigations between 2010 and 2012.

Records from 2010 to 2026. Most recent: inspection, 9 April 2026.

Built
1986
Last inspected
9 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY3314
268715
Flag
UNITED STATES
Maury page id
psix-268715

Documentation record

Registered dimensions (L × B × D)132.0 ft × 38.0 ft × 9.5 ft
Registered tonnagegross 78 / net 53
ITC dimensions (L × B × D)132.0 ft × 38.0 ft × 9.5 ft
ITC tonnagegross 1,230 / net 387
BuilderPATTI SHIPYARD INC · PENSACOLA, FL, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOLINE, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 3 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it78 - Regulatory (Subpart C or D), Gross Ton
1230 - Convention (Subpart B), Gross Ton
53 - Regulatory (Subpart C or D), Net Ton
387 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

9 April 2026 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8345247
4 November 2025 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8264818
21 October 2025 In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8257779
8 September 2025 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8229270
28 May 2025 MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8133553
23 October 2024 Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8022253
9 September 2024 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8012020
22 May 2024 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7917247
12 October 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7807391
16 May 2023 Annual Inspection · DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7689972
19 July 2022 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7510359
10 May 2021 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7189977
9 November 2020 Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7090241
27 May 2020 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6961926
10 June 2019 Annual Inspection · DAPI Audit · Security Plan Review - ASP · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6710023
2 May 2018 Administrative Inspection · Deficiency Check · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6404190
27 June 2017 DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6188777
8 May 2017 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6141709
12 July 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5938057
14 April 2016 MTSA Verification · COI Inspection · Administrative Inspection · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5854121
26 February 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5822880

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023 Resolved
Exhaust gas must not leak from the piping or any connections. The Port generator had an exhaust leak near the muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 20 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022 Resolved
Repair diesel fuel leak from day tank in port generator room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 21 July 2022
Resolution: fixed diesel leak, replaced elbow in piping.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 July 2022 Resolved
Replace the missing insulation from above the port main engine to maintain the fire control boundary in accordance with the vessels Fire Safety Plan.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 28 July 2022
Resolution: replaced insulation
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 July 2022 Resolved
Replace temporary patch on water line in tool room with a permanent repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 28 July 2022
Resolution: replaced rubber connection with metal connection
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 July 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Replace expired components of first aid kit and have all required equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 28 July 2022
Resolution: replaced expired first aid kit equipment
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021 Resolved
02 Child life jackets need new retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel replaced life jackets
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2021 Resolved
02 emergency lights not fully operational. replace or repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel replaced both emergency lights
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021 Resolved
replace first aid kit with non expired equipment
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2021 Resolved
Secure CO2 and helium cylinders.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel secured all gas cylinders
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020 Resolved
Destroy and replace 13 child life jackets and 1 kapok vest type life jacket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2020
Resolved 27 May 2020
Resolution: replaced prior to completion of inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020 Resolved
Replace reflective tape on 20 identified adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: tape replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2020 Resolved
Repair lagging around muffler and exhaust for heat protection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: lagging patched
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 May 2020 Resolved
Repair A/C leak in crew state room,
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 15 June 2020
Resolution: repaired
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 27 May 2020 Resolved
Repair emergency light in gift shop for proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 May 2020 Resolved
Relabel markings on PFD stowage compartment on bridge seats to state 51 Adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 15 June 2020
Resolution: relabled
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 May 2018 Resolved
1. Replace or make permanent repairs to the Port Main Engine exhaust flexible pipe joint, pipe has an exhaust leak
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: Replaced Port Main Engine exhaust flexible pipe joint, engine was ran, No leaks present
Stability › Watertight Integrity › General
Issued 2 May 2018 Resolved
Make Repairs to the Starboard side Maindeck Generator Rooms WTD dog
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: Starboard side Maindeck Generator Rooms WTD dog was loose, tightened the packing nut, door is back in full operation
Electrical › Lighting (service) › Outlet Box
Issued 8 May 2017 Resolved
Broken cover.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Replaced cover
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017 Resolved
Battery dead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Replaced battery
Documentation › Certificates/Documents › Stability Letter
Issued 2 May 2016 Resolved
Vessel does not have the most current stability letter posted at the operating station in accordance with 46CFR115.306. Vessel has 7 days to post the most current stability letter to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel does have the most current stability letter posted at the operating station in accordance with 46CFR115.306.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 May 2016 Resolved
Vessel steering system has a damaged hydraulic hose on the port side which has been determined by the marine inspector as not in suitable condition for the service it is intended for in accordance with 46CFR122.320. Vessel has 7 days to replace the hose to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel steering system damaged hydraulic hose on the port side has been replaced and it is in suitable condition for the service it is intended for in accordance with 46CFR122.320.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2016 Resolved
Vessel's 3 life rings have severely dry rotted line which has been determined by the marine inspector to not be in serviceable condition in accordance with 46CFR117.70. Vessel has 7 days to replace the the line or life rings to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Onsite Verification
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2016 Resolved
Vessel has a damaged light fixture in bow thruster compartment. Vessel has 7 days to make repairs in accordance with 46CFR120.410 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 11 May 2016
Resolution: Vessels damaged light fixture in bow thruster compartment has been replaced and repairs are in accordance with 46CFR120.410 to the satisfaction of the attending marine
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 May 2016 Resolved
Vessel has excessive hydraulic oil in bow thruster compartment which has been determined by the marine inspector as an unsafe condition in accordance with 46CFR176.830(b). Vessel has 7 days to remove hydraulic oil from compartment to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessels excessive hydraulic oil in bow thruster compartment has been removed.

Casualty record · 2

9 July 2010Routine · role: Involved in a Marine Casualty · activity 3793908
25 July 2012Routine · role: Involved in a Marine Casualty · activity 4395169
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.