Records from 1986 to 2026. Most recent: inspection, 9 April 2026.
Inspection history · 149
9 April 2026
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8345247
4 November 2025
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8264818
21 October 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8257779
8 September 2025
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8229270
28 May 2025
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8133553
23 October 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8022253
9 September 2024
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8012020
22 May 2024
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7917247
12 October 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7807391
16 May 2023
Annual Inspection · DAPI Audit · In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7689972
19 July 2022
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7510359
10 May 2021
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7189977
9 November 2020
Examination of Repairs · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7090241
27 May 2020
Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6961926
10 June 2019
Annual Inspection · DAPI Audit · Security Plan Review - ASP · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6710023
2 May 2018
Administrative Inspection · Deficiency Check · DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6404190
27 June 2017
DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6188777
8 May 2017
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6141709
12 July 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5938057
14 April 2016
MTSA Verification · COI Inspection · Administrative Inspection · MARPOL Annex VI Survey · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5854121
26 February 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5822880
18 November 2015
Deficiency Check · Administrative Inspection · Spot Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5766189
15 September 2015
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5719694
16 June 2014
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4898213
26 July 2012
Damage Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4392260
25 July 2012
Type not recorded
No type recorded · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4395169
12 June 2012
DAPI Audit · Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4342211
19 September 2011
Drydock Extension
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4184268
28 May 2008
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3221473
30 July 2007
MTSA Verification · Re-Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3014557
11 October 2006
Hull Examination
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2797723
1 May 2006
COI Inspection · MTSA Verification
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2635840
29 September 2004
MTSA Verification
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2265602
26 May 2004
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2062024
16 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970572
23 October 2003
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1938468
6 May 2003
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1787871
2 April 2003
Administrative Inspection
Administrative · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1767205
6 May 2002
Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1613652
8 May 2001
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1448289
8 August 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1453796
17 November 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 810322
20 October 1999
Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1369390
13 October 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1372831
17 August 1999
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1112831
26 May 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455711
28 April 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 758413
21 April 1999
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 204414
8 April 1999
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441516
2 September 1998
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 419983
18 August 1998
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 796621
2 June 1998
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1427564
4 May 1998
Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1125207
25 March 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1465361
4 December 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 776704
12 November 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 785468
18 September 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 778027
8 September 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1439910
4 September 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1121526
21 July 1997
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 780094
10 June 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 707534
2 June 1997
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 117837
29 May 1997
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435933
5 March 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1442529
16 January 1997
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1099109
22 December 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 11575
3 December 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1380707
3 November 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 173323
16 September 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 758391
9 September 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 204415
5 September 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1418012
17 July 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 758396
16 July 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 204413
27 June 1996
Examination of Repairs · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1247880
25 June 1996
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 90252
29 May 1996
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1448764
13 March 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1437062
13 December 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 877038
7 December 1995
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435700
17 November 1995
Deadweight Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 881416
16 November 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 51024
31 October 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1188392
17 October 1995
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1190530
4 October 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 872212
30 September 1995
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 87627
1 September 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1434299
5 July 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1192230
14 June 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1186953
1 June 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 876155
15 May 1995
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224187
26 April 1995
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 911568
13 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159193
23 December 1994
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 848189
7 December 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 830689
22 November 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 862028
10 October 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 102865
8 October 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 138223
25 September 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 170428
16 September 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 49473
11 September 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 6765
11 September 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 187223
7 September 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 65339
7 September 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1440851
2 June 1994
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1333194
31 May 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1169718
11 May 1994
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 643067
11 May 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 861629
21 March 1994
Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 855865
14 February 1994
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 856413
21 January 1994
Deficiency Check · Sanitary Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1373968
11 January 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1163520
15 October 1993
Sanitary Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1151443
13 October 1993
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 842764
22 September 1993
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1151714
21 September 1993
Re-Inspection · Sanitary Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1377065
15 June 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1133493
2 June 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1354364
26 April 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 833187
25 March 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 838469
17 December 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1403570
16 October 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 957878
10 September 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1458973
10 June 1992
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 948675
3 June 1992
Deficiency Check · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1410736
3 April 1992
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 82806
26 March 1992
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 86929
10 March 1992
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 12988
20 January 1992
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 169712
13 December 1991
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 643066
22 November 1991
Deficiency Check · Sanitary Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 941031
22 November 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1250140
10 November 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1250909
24 October 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1245976
22 October 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1468682
13 August 1991
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 937099
26 July 1991
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1257103
6 July 1991
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 219864
12 June 1991
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 937070
31 May 1991
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1322477
30 November 1990
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 899844
21 March 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 928049
1 April 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1041905
12 January 1989
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1199166
24 March 1988
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1351137
24 March 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1018801
21 August 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 988023
25 June 1986
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1303366
13 June 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1303702
24 May 1986
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993612
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 May 2023
Resolved
Exhaust gas must not leak from the piping or any connections. The Port generator had an exhaust leak near the muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 20 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022
Resolved
Repair diesel fuel leak from day tank in port generator room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 21 July 2022
Resolution: fixed diesel leak, replaced elbow in piping.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 July 2022
Resolved
Replace the missing insulation from above the port main engine to maintain the fire control boundary in accordance with the vessels Fire Safety Plan.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 28 July 2022
Resolution: replaced insulation
09 - Working and Living Conditions › 091 - Living Conditions › Water, pipes, tanks
Issued 19 July 2022
Resolved
Replace temporary patch on water line in tool room with a permanent repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2022
Resolved 28 July 2022
Resolution: replaced rubber connection with metal connection
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 July 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Replace expired components of first aid kit and have all required equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 August 2022
Resolved 28 July 2022
Resolution: replaced expired first aid kit equipment
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2021
Resolved
02 Child life jackets need new retro-reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel replaced life jackets
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2021
Resolved
02 emergency lights not fully operational. replace or repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel replaced both emergency lights
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 May 2021
Resolved
replace first aid kit with non expired equipment
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 May 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2021
Resolved
Secure CO2 and helium cylinders.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 May 2021
Resolution: vessel secured all gas cylinders
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020
Resolved
Destroy and replace 13 child life jackets and 1 kapok vest type life jacket.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2020
Resolved 27 May 2020
Resolution: replaced prior to completion of inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2020
Resolved
Replace reflective tape on 20 identified adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: tape replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2020
Resolved
Repair lagging around muffler and exhaust for heat protection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: lagging patched
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 27 May 2020
Resolved
Repair A/C leak in crew state room,
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 15 June 2020
Resolution: repaired
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 27 May 2020
Resolved
Repair emergency light in gift shop for proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 11 June 2020
Resolution: repaired
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 May 2020
Resolved
Relabel markings on PFD stowage compartment on bridge seats to state 51 Adult life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2020
Resolved 15 June 2020
Resolution: relabled
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 May 2018
Resolved
1. Replace or make permanent repairs to the Port Main Engine exhaust flexible pipe joint, pipe has an exhaust leak
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: Replaced Port Main Engine exhaust flexible pipe joint, engine was ran, No leaks present
Stability › Watertight Integrity › General
Issued 2 May 2018
Resolved
Make Repairs to the Starboard side Maindeck Generator Rooms WTD dog
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2018
Resolved 10 May 2018
Resolution: Starboard side Maindeck Generator Rooms WTD dog was loose, tightened the packing nut, door is back in full operation
Electrical › Lighting (service) › Outlet Box
Issued 8 May 2017
Resolved
Broken cover.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Replaced cover
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017
Resolved
Battery dead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 8 May 2017
Resolution: Replaced battery
Documentation › Certificates/Documents › Stability Letter
Issued 2 May 2016
Resolved
Vessel does not have the most current stability letter posted at the operating station in accordance with 46CFR115.306. Vessel has 7 days to post the most current stability letter to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel does have the most current stability letter posted at the operating station in accordance with 46CFR115.306.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 May 2016
Resolved
Vessel steering system has a damaged hydraulic hose on the port side which has been determined by the marine inspector as not in suitable condition for the service it is intended for in accordance with 46CFR122.320. Vessel has 7 days to replace the hose to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessel steering system damaged hydraulic hose on the port side has been replaced and it is in suitable condition for the service it is intended for in accordance with 46CFR122.320.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2016
Resolved
Vessel's 3 life rings have severely dry rotted line which has been determined by the marine inspector to not be in serviceable condition in accordance with 46CFR117.70. Vessel has 7 days to replace the the line or life rings to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 24 May 2016
Resolution: Onsite Verification
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2016
Resolved
Vessel has a damaged light fixture in bow thruster compartment. Vessel has 7 days to make repairs in accordance with 46CFR120.410 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 11 May 2016
Resolution: Vessels damaged light fixture in bow thruster compartment has been replaced and repairs are in accordance with 46CFR120.410 to the satisfaction of the attending marine
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 2 May 2016
Resolved
Vessel has excessive hydraulic oil in bow thruster compartment which has been determined by the marine inspector as an unsafe condition in accordance with 46CFR176.830(b). Vessel has 7 days to remove hydraulic oil from compartment to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 11 May 2016
Resolution: Vessels excessive hydraulic oil in bow thruster compartment has been removed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 November 2015
Resolved
Ring-weld potable water pipe on the portside of the #4 void in WTB pentration between the #4 and #5 voids.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 18 November 2015
Resolution: Onsite verification that they welded pipe.
Electrical › Electrical Distribution System (service) › Cable
Issued 12 November 2015
Resolved
Replace damaged wiring adjacent to the starboard rudder post in the lazerette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 18 November 2015
Resolution: Damaged wire replaced
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 November 2015
Resolved
Ensure wire splices for heat tape for the drain line in the lazarette are enclosed in an approved junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 18 November 2015
Resolution: Splices have been placed in a approved junction box
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 June 2014
Resolved
Vessel has not submitted a Nontank Vessel Response Plan (NTVRP) and does not meet minimum standard applicability and compliance required by 33CFR155.5015 and 33CFR155.5065. Owner must identify salvage response resources through written consent by contract or other approved means (see Definition 33CFR155.5020), that the resource provider agrees to provide the services that are listed in 33 CFR 155.
Action required: 705 - Other - as specified
Resolved 1 July 2014
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 June 2014
Resolved
4. Vessel has not submitted a Nontank Vessel Response Plan (NTVRP) and does not meet minimum standard applicability and compliance required by 33CFR155.5015 and 33CFR155.5065. 1. Owner must submit a NTVRP to the Coast Guard for approval per 33CFR155.5065 and 33CFR155.5023. Vessel has until 31JUL14 (to complete or will be restricted from carrying passengers underway until corrected to th
Action required: 705 - Other - as specified
Due 31 July 2014
Resolved 17 July 2014
Resolution: IOA approved to expire 31OCT14
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 June 2014
Resolved
2. Vessel has not submitted a Nontank Vessel Response Plan (NTVRP) and does not meet minimum standard applicability and compliance required by 33CFR155.5015 and 33CFR155.5065. Owner must ensure the availability of a Oil spill removal organization (OSRO), through contract or other approved means (see Definition 33CFR155.5020), the response resources necessary to respond to a discharge up to the ves
Action required: 705 - Other - as specified
Resolved 1 July 2014
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 16 June 2014
Resolved
1. Vessel has not submitted a Nontank Vessel Response Plan (NTVRP) and does not meet minimum standard applicability and compliance required by 33CFR155.5015 and 33CFR155.5065. Owner must identify a Qualified Individual and alternate as who meet the requirements of 33CFR155.1026. Vessel has 7 days (23JUN14) to complete or will be restricted from carrying passengers underway until corrected to the s
Action required: 705 - Other - as specified
Resolved 1 July 2014
Engineering › Steering Gear System › Rudder
Issued 26 July 2012
Resolved
Prior to carrying passengers make permanent repairs to the steering system and to the satisfaction of the local OCMI
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 27 July 2012
Resolution: Made permanent repairs to the steering system.
Engineering › Steering Gear System › Pin
Issued 26 July 2012
Resolved
Make permanent weld repairs to the retaining ring that holds the pin that connects the rudder arm to the rudder post in place.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 3 August 2012
Resolution: Made permanent weld repairs to the retaining ring that holds the pin that connects the rudder arm to the rudder post in place.
Documentation › Logs/Records › Logbook (official)
Issued 12 June 2012
Resolved
Provide pre-underway check off log
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Provided pre-underway check off log
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 12 June 2012
Resolved
Provide FCC license for Captain (operator)
Action required: 705 - Other - as specified
Resolved 26 July 2012
Resolution: Provided FCC license for Captain (operator)
Stability › Severe Wind/Roll › General
Issued 12 June 2012
Resolved
Provide passenger capacity signs for decks
Action required: 705 - Other - as specified
Resolved 27 June 2012
Resolution: Passenger capacity signs are located on each deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 30 July 2007
Resolved
Overhead light fixtures in engine room had no guards and were missing covers. Instructed owner that explosion proof fixtures were needed. Several fixtures were the propper type, but unserviceable. Provided owner with CFR sites and requirements to effect corrections.
Condition: Improper/Lack of Maintenance
Due 30 August 2007
Resolved 28 May 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 30 July 2007
Resolved
Safety Radio Telephone Certificate not on board.
Condition: Unknown
Due 30 August 2007
Resolved 30 August 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 11 October 2006
Resolved
PROPERLY SUPPORT EXTERNAL EXHAUST PIPES ON THE STARBOARD SIDE OF THE VESSEL AFT.
Due 30 October 2006
Resolved 11 October 2006
Construction/Loadline › Structures › Plowshare Breakwater
Issued 11 October 2006
Resolved
GRIND OUT DEEP PITS IN THE BOWTHRUSTER TUBE AND FILL WITH WELDMENT.
Due 30 October 2006
Resolved 11 October 2006
Construction/Loadline
Issued 20 October 1999
Resolved
INSTALL STRAINER ON FOREPEAK BILGE PIPING.
Condition: Unknown
Due 20 October 1999
Resolved 20 October 1999
Electrical
Issued 26 May 1999
Resolved
REPLACE OR REPAIR ALL NON-FUNCTIONAL "E" LIGHTS.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Electrical
Issued 26 May 1999
Resolved
INSULATE ELECTRICAL WIRING IN THE SECOND DECK AIR HANDLER CLOSET.
Condition: Unknown
Due 27 June 1999
Resolved 1 June 1999
Engineering
Issued 26 May 1999
Resolved
REPAIR GAUGES (OIL PRESSURE) TO THE MAIN AND #1 GENERATOR.
Condition: Unknown
Due 26 May 1999
Resolved 26 May 1999
Lifesaving
Issued 26 May 1999
Resolved
RENUMBER AND LABEL LIFE JACKET LOCKER AFT OF THE PILOT HOUSE ON THE THIRD DECK.
Condition: Unknown
Due 28 May 1999
Resolved 1 June 1999
Navigation
Issued 26 May 1999
Resolved
REPLACE BURNED OUT LIGHT BULBS FOR VISUAL ALARM WITH STEERING FAILURE ALARMPANEL.
Condition: Unknown
Due 27 June 1999
Resolved 1 June 1999
Lifesaving
Issued 4 December 1997
Resolved
THIS VESSEL IS NOT TO CARRY PASSENGERS UNTIL A COMPLETE INSPECTION IS DONE BY A COAST GUARD MARINE INSPECTOR AND THE SATISFACTORY COMPLETION OF ALL SAFETY DRILLS.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Accommodation/Occupational Safety
Issued 12 November 1997
Resolved
REPLACE BROKEN WINDOWS IN AFT 3RD DECK POKER ROOM PRIOR TO CARRYING PASSENGERS UNDERWAY.
Condition: Unknown
Due 12 November 1997
Resolved 12 November 1997
Fire Fighting
Issued 8 September 1997
Resolved
INSTALL BRACKET FOR FIRE EXTINGUISHER ON THE THIRD DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Electrical
Issued 8 September 1997
Resolved
REPAIR PORT GENERATOR
Condition: Unknown
Due 8 September 1997
Resolved 8 September 1997
Accommodation/Occupational Safety
Issued 4 September 1997
Resolved
REPLACE BROKEN WINDOWS IN AFT 3RD DECK POKER ROOM PRIOR TO CARRYING PASSENGERS UNDERWAY.
Condition: Unknown
Due 4 September 1997
Resolved 4 September 1997
Accommodation/Occupational Safety
Issued 21 July 1997
Resolved
REPLACE BROKEN WINDOW IN AFT 3RD DECK POKER ROOM.
Condition: Unknown
Due 21 July 1997
Resolved 21 July 1997
Electrical
Issued 29 May 1997
Resolved
SECURE ALL LOOSE CABLE/WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Fire Fighting
Issued 29 May 1997
Resolved
REPLACE MISSING DOOR KNOBS IN DOORS.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Electrical
Issued 29 May 1997
Resolved
REPAIR OR REPLACE NON-FUNCTIONAL "E" LIGHTS PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Lifesaving
Issued 29 May 1997
Resolved
RELABEL "EMERGENCY EXIT KEEP CLEAR" PLACARD IN ENGINE ROOM.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Lifesaving
Issued 29 May 1997
Resolved
REPLACE MISSING CHILD LIFEJACKET PRIOR TO THE CARRIAGE OF PASSENGERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Fire Fighting
Issued 29 May 1997
Resolved
REPAIR FWD BLKHEAD IN HARD COUNT ROOM.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Accommodation/Occupational Safety
Issued 29 May 1997
Resolved
REPLACE BROKEN WINDOW IN AFT 3RD DECK POKER ROOM.
Condition: Unknown
Due 29 May 1997
Resolved 29 May 1997
Lifesaving
Issued 29 May 1996
Resolved
REPLACE WORN LIFE RINGS (3) PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 30 May 1996
Resolved 31 May 1996
Fire Fighting
Issued 29 May 1996
Resolved
MOUNT FIRE EXTINGUISHER IN HARD AND SOFT COUNT.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Electrical
Issued 29 May 1996
Resolved
REPAIR/REPLACE EMERGENCY LIGHT IN ENGINEROOM.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Engineering
Issued 7 December 1995
Resolved
PROVIDE FUEL OIL CUT-OFF VALVES WITH PROPER MARKINGS TO GENERATORS.
Condition: Unknown
Due 28 December 1995
Resolved 3 January 1996
Fire Fighting
Issued 7 December 1995
Resolved
REMOVE CARPET FROM WALLS AND STACHIONS.
Condition: Unknown
Due 28 January 1996
Resolved 3 January 1996
Engineering
Issued 7 December 1995
Resolved
PROVIDE MARKINGS FOR FUEL OIL CUT-OFF VALVE TO ENGINEROOM WITH DIRECTIONAL ARROWS.
Condition: Unknown
Due 28 December 1995
Resolved 3 January 1996
Accommodation/Occupational Safety
Issued 7 December 1995
Resolved
PROVIDE WIRE INSERTED GLASS TO SECOND DECK DOOR FORWARD.
Condition: Unknown
Due 28 December 1995
Resolved 3 January 1996
Documentation
Issued 31 October 1995
Resolved
FOLLOWING CHANGEOUT OF SLOT MACHINES CONDUCT DEADWEIGHT SURVEY OF VESSEL.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Electrical
Issued 1 September 1995
Resolved
REPAIR WIRING IN JUNCTION BOX IN SLOT OFFICE.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Electrical
Issued 1 September 1995
Resolved
PERMANENTLY MOUNT AIR PURIFIER ON THIRD DECK.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Electrical
Issued 1 September 1995
Resolved
REMOVE EXTENSION CORD IN SURVEILLANCE AND MOUNT POWER STRIP.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Accommodation/Occupational Safety
Issued 1 September 1995
Resolved
PROVIDE INSECT SCREEN TO POTABLE WATER TANK.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Lifesaving
Issued 1 September 1995
Resolved
PROVIDE SEPARATE STOWAGE OF CHILD AND ADULT LIFE JACKETS MAIN DECK.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Engineering
Issued 1 September 1995
Resolved
PROVIDE MACHINERY GUARDS FOR BOTH MDE.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Electrical
Issued 1 September 1995
Resolved
REPLACE BATTERY FOR EMERGENCY LIGHT IN ENGINERROM.
Condition: Unknown
Due 1 September 1995
Resolved 1 September 1995
Navigation
Issued 1 June 1995
Resolved
HAVE AIR RECEIVER ACCESSIBLE FOR MARINE INSPECTOR.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Deck/Cargo
Issued 1 June 1995
Resolved
ATTACH LINE TO ANCHOR.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Lifesaving
Issued 1 June 1995
Resolved
PROVIDE SAFETY HARNESS FOR PICK-UP MAN DURING MAN OVERBOARD EVOLUTIONS.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Accommodation/Occupational Safety
Issued 1 June 1995
Resolved
PROVIDE INSECT SCREEN FOR POTABLE WATER TANK.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Electrical
Issued 1 June 1995
Resolved
PROVIDE COVER FOR LIGHT IN LIQUOR LOCKER AND "GREEN" VOID.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Electrical
Issued 1 June 1995
Resolved
REMOVE ALL PORTABLE HEATERS IN AFT STEERING VOID.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Electrical
Issued 1 June 1995
Resolved
PLACE "E" ON ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Fire Fighting
Issued 1 June 1995
Resolved
PROPERLY MOUNT FIRE EXTINGUISHER IN SECURITY.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Electrical
Issued 1 June 1995
Resolved
PROPERLY HANG WIRES IN BOW THRUSTER ROOM.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Navigation
Issued 1 June 1995
Resolved
MARK VESSEL'S NAME ON STERN OF VESSEL.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Electrical
Issued 1 June 1995
Resolved
WATER PROOF CONTROLLER FOR CAPSTAN.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Electrical
Issued 1 June 1995
Resolved
PROPERLY HANG WIRES IN LIQUOR LOCKER.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Electrical
Issued 1 June 1995
Resolved
PROVIDE NEW BATTERY FOR E-LIGHT IN HARD COUNT.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Lifesaving
Issued 1 June 1995
Resolved
MARK NAME ON RING BUOY.
Condition: Unknown
Due 1 July 1995
Resolved 16 June 1995
Engineering
Issued 1 June 1995
Resolved
PROVIDE FLAME SCREENS FOR FUEL TANK.
Condition: Unknown
Due 1 July 1995
Resolved 5 July 1995
Electrical
Issued 13 April 1995
Resolved
PROVIDE PROPER WIRE TIES (STEEL) THROUGHOUT VESSEL.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Lifesaving
Issued 13 April 1995
Resolved
PROPERLY MOUNT CO2 BOTTLES ON 3RD DECK AND IN LIQUOR LOCKER.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
REMOVE EXTENSION CORDS IN SLOTS OFFICE AND HARD COUNT.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
PROPERLY MOUNT SURGE PROTECTORS THROUGHOUT VESSEL.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
PROVIDE MACHINERY GUARDS FOR BOTH GENERATORS.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
REMOVE DEADENDED WIRE ON BRIDGE AND IN AIR HANDLER ROOM THIRD DECK.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 13 April 1995
Resolved
REPAIR WIRE TO BEER COOLER THIRD DECK.
Condition: Unknown
Due 13 April 1995
Resolved 13 April 1995
Electrical
Issued 22 November 1994
Resolved
CHECK AND CHANGE AS NECESSARY ALL 'E' LIGHTS BATTERIES FOR PROPER OPERATION
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Accommodation/Occupational Safety
Issued 22 November 1994
Resolved
CLEAN EXCESS OIL FROM ENGINE ROOM AND STBB GENERATOR ROOM
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Lifesaving
Issued 22 November 1994
Resolved
REMOVE LIQUOR OR INSTALL LIQUOR LOCKER FOR ALL ALCOHOL ON VESSEL
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Deck/Cargo
Issued 22 November 1994
Resolved
REPLACE PLUG IN AIR RECEIVER IN #2 COMPRESSOR STBD GENERATOR ROOM.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 7 September 1994
Resolved
REDO FIRE STATION / FIRE EXT. MARKING SYSTEM.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Fire Fighting
Issued 7 September 1994
Resolved
REPLACE HAND FIRE PUMP WITH ONE THAT MEETS THE REQUIREMENTS IN 46CFR181.10.
Condition: Unknown
Due 7 September 1994
Resolved 7 September 1994
Engineering
Issued 7 September 1994
Resolved
MACHINERY GUARD OVER STBD SHAFT IS RUBBING HYDRO LINES.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 7 September 1994
Resolved
ELECTRICAL MAT STBD GEN ROOM IS A TRIPPING HAZ. CUT TO FIT PROPERLY.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 7 September 1994
Resolved
REDO/REPAIR SAFETY CHAINS FOR CO2 BOTTLES.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Construction/Loadline
Issued 7 September 1994
Resolved
INSTALL BRACKET FOR DOGGING WRENCH TO FORWARD VOID.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Lifesaving
Issued 2 June 1994
Resolved
REPAIR/ REPLACE ALL RING BOUYS ABOARD VSL.
Condition: Unknown
Due 2 July 1994
Resolved 30 June 1994
Electrical
Issued 11 May 1994
Resolved
ISSUED VIOLATION FOR OUTSTANDING REQUIREMENT._x001C_ IDENT/ DAV5 ISSUED 12JUN91 BY SLMMS CASE/ MI91025084 _x001C_ PROVIDE APPROVED ELECTRICAL PLANS FOR NEW ELECTRICAL INSTALLATION FOR _x001C_ HAVC AND GAMING EQUIPMENT.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Fire Fighting
Issued 14 February 1994
Resolved
SUBMIT PLANS DESCRIBING HOW CORRECTIONS WILL BE MADE TO CORRECTION THE LACKOF AN A-0 VENTILATION SYSTEM IN THE GENERATOR ROOMS.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Fire Fighting
Issued 14 February 1994
Resolved
MAKE CORRECTIONS TO THE VENTILATION SYSTEMS IN THE GENERATOR ROOMS, IAW SUBMITTED PLANS TO SATISFATION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 February 1994
Resolved 14 February 1994
Fire Fighting
Issued 21 January 1994
Resolved
THE VENT OPENINGS TO THE ENGINE ROOM DON'T HAVE FIRE DAMPERS AS REQUIRED BY46 CFR 72.05. SUBMIT ROUGH PLANS AND WRITEN PROPOSAL TO OCMI ON HOW YOU WILL CORRECT THIS PROBLEM.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Fire Fighting
Issued 21 January 1994
Resolved
UPON RECEIPT OF APPROVED PROPOSAL, INSTALL ENGINE ROOM VENT FIRE DAMPERS.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Electrical
Issued 11 January 1994
Resolved
REPLACE COVER TO THERMOSTAT IN 2ND DECK HEATING COMPARMENT
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Electrical
Issued 11 January 1994
Resolved
REPLACE MISSING OUTLET COVER 2ND DECK HEATING ROOM
Condition: Unknown
Due 11 February 1994
Resolved 11 February 1994
Lifesaving
Issued 2 June 1993
Resolved
PROVIDE COPIES OF FIRE EQUIPMENT AND ELEVATOR SERVICING REPORTS.
Condition: Unknown
Due 2 July 1993
Resolved 18 June 1993
Lifesaving
Issued 2 June 1993
Resolved
PROVIDE NEW LIFE LINE FOR RESCUE MAN ON STAGES . LINE SHALL BE MADE WITH AT LEAST 3/8" LINE AND ATTACHED WITH A SNAP HOOK.
Condition: Unknown
Due 2 July 1993
Resolved 18 June 1993
Documentation
Issued 25 March 1993
Resolved
THERE IS NO COPY OF THE RULES OF THE ROAD ON BOARD THE VSL.
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Fire Fighting
Issued 25 March 1993
Resolved
REPAIR AND LABEL REMOTE VENTIALTION SHUT DOWNS ON VSL._x001C_
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Lifesaving
Issued 25 March 1993
Resolved
PROVIDE AN OPENING ON THE THIRD DECK THROUGH THE CANVAS COVERING, TO ALLOW PASSENGERS ACCESS THE THE STAIRWAY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 March 1993
Resolved 25 March 1993
Unknown
Issued 3 June 1992
Resolved
PLACE NAME OF VESSEL ON THE PORT / STBD SIDES FORWARD AND STERN OF VESSEL.
Condition: Unknown
Due 3 July 1992
Resolved 1 July 1992
Lifesaving
Issued 3 June 1992
Resolved
PROVIDE SIX ADULT PFD'S. TOTAL PERSONS IS REDUCED TO 594 UNTIL THESE PFD'SARE ON BOARD.
Condition: Unknown
Due 3 July 1992
Resolved 1 July 1992
Lifesaving
Issued 10 November 1991
Resolved
Provide suitable rescue boat for winter mooring._x001C_ (boat not required once river is frozen over)
Condition: Unknown
Due 10 November 1991
Resolved 10 November 1991
Accommodation/Occupational Safety
Issued 22 October 1991
Resolved
ADD COAMING AROUND STBD ENGINE ROOM VENT LOUVERS AND FAN._x001C_ PUT 1" CHECK VALVE IN THE BASE TO DRAIN.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Unknown
Issued 22 October 1991
Resolved
ADD LOUVERS TO EXTERIOR ENGINE ROOM DOOR (FR. 61)_x001C_ NOT LOWER THAN 27" FROM DECK.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 12 June 1991
Resolved
RENEW RED NIGHT AND DAY ORANGE SMOKE DISTRESS FLARES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Documentation
Issued 12 June 1991
Resolved
PROVIDE APPROVED ELECTRICAL PLANS FOR NEW ELECTRICAL INSTALLATION FOR HVAC AND GAMING EQUIPMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 12 June 1991
Resolved
PLACE ON BOARD OIL POLLUTION PREVENTION PLACARD._x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Accommodation/Occupational Safety
Issued 12 June 1991
Resolved
PLACE ON BOARD THROUGHOUT VESSEL MARPOL ANNEX V THRASH PLACARDS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Lifesaving
Issued 12 June 1991
Resolved
PROVIDE TO [name withheld] PLAN, SHOWING LOCATION AND TYPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 25 June 1986
Resolved
REPLACE 4-DOG DOOR IN FWD BULKHEAD OF ENG ROOM, STBD SIDE, WITH A QUICK ACTING TYPE WATER TIGHT DOOR.
Condition: Unknown
Due 25 June 1986
Resolved 25 June 1986
Documentation
Issued 24 May 1986
Resolved
OBTAIN AND PLACE ONBOARD VESSEL THE CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 May 1986
Resolved 24 May 1986
Documentation
Issued 24 May 1986
Resolved
OBTAIN AND POST ONBOARD VESSEL THE FCC COMMUNICATIONS SAFETY ACT RADIOTELEPHONY CERT.
Condition: Unknown
Due 24 May 1986
Resolved 24 May 1986
Lifesaving
Issued 24 May 1986
Resolved
PLACE ONBOARD ADDITIONAL 59 ADULT PFD'S FOR TOTAL OF 850; 5 ADDITIONAL CHILDREN PFD'S FOR A TOTAL OF 85 AND PROVIDE ADEQUATE STOWAGE FOR ALL PFD'S ONBOARD.
Condition: Unknown
Due 24 May 1986
Resolved 24 May 1986