Records from 1986 to 2007. Most recent: inspection, 23 November 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
23 November 2007
ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3099238
18 May 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2071600
30 May 2002
MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection · Passenger/Freight Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1622090
10 November 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 434656
30 November 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 5661
28 October 1998
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 421873
23 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 646464
13 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399483
1 June 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 182170
30 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387214
20 November 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 384991
28 December 1994
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 373774
28 December 1994
Uninspected Other
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 851564
3 December 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 363146
17 July 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 331397
12 June 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 323852
2 June 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 316619
5 December 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 498345
16 June 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 309553
Navigation
Issued 13 January 1997
Resolved
Vessel was missing required chart 18746, chart 18740 was a 14 Oct 95 35th Edition with no corrections, and chart 18751 was a 21 Jul 84 30th Edition slast corrections where from 88.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 28 December 1994
Resolved
MAKE PERMANENT REPAIRS TO THE LEAKING, PORT SIDE, LOWER LEVEL, FORWARD OUTBOARD CHECK VALVE. PROVIDE (NKK) REPORT ON THE CORRECTION, PRIOR TO RETURN TO A U. S. PORT, PER ILLC CHAPT II REG 22 (1).
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Lifesaving
Issued 28 December 1994
Resolved
REPLACE OR REPAIR LIGHT ON RING BUOY (STARBOARD SIDE), PRIOR TO DEPARTURE, PER SOLAS CHPT III REG 21.
Condition: Unknown
Due 27 January 1995
Resolved 29 December 1994
Fire Fighting
Issued 28 December 1994
Resolved
PROVIDE AUTOMATIC CLOSING DEVICE FOR THE FIRE DOORS TO THE STEERING GEAR SPACE AND EMERGENCY GENERATOR ROOM, PRIOR TO RETURN TO A U. S. PORT, PER SOLAS CHPT II-2 REG 46 (1).
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Lifesaving
Issued 28 December 1994
Resolved
REMOVE PAINT CANS FROM STEERING GEAR ROOM, PRIOR TO DEPARTURE, PER SOLAS CHPT II-1 REG 45._x001C_ _x001C_ X
Condition: Unknown
Due 27 January 1995
Resolved 29 December 1994
Lifesaving
Issued 28 December 1994
Resolved
PROVIDE 2 PERSONAL LIFEJACKETS FOR ENGINEROOM PERSONNEL IN CONTROL ROOM, PRIOR TO DEPARTURE, PER SOLAS CHPT III REG 22.
Condition: Unknown
Due 27 January 1995
Resolved 29 December 1994
Fire Fighting
Issued 28 December 1994
Resolved
REMOVE HOLD BACK DEVICES FROM THE FIRE DOORS ON THE STAIRWAYS AND ENGINEROOM FIREDOORS (TAKE HOOKS OFF), PRIOR TO RETURN, PER SOLAS CHPT II-2REG 47(2).
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995
Construction/Loadline
Issued 28 December 1994
Resolved
MAKE PERMANENT REPAIRS TO THE LOCKING RAM'S PATCHED LINES ON THE #2 HATCH COVERS (PORT AND STARBOARD), PRIOR TO RETURN TO A U. S. PORT. (COTP ORDER)
Condition: Unknown
Due 28 November 1995
Resolved 28 November 1995