CHARLESTON PRINCESS

CHARLESTON PRINCESS is a 1986 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1986, most recently in May 2026, along with 177 deficiencies and 5 casualty investigations between 2006 and 2024.

Records from 1986 to 2026. Most recent: inspection, 8 May 2026.

Built
1986
Last inspected
8 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK9315
268782
Flag
UNITED STATES
368102480
Maury page id
psix-268782

Inspections, by type

…with no type recorded8
Years with a record 37 calendar years (1986–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)97.8 ft × 28.0 ft × 2.3 ft
Registered tonnagegross 97 / net 87
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC · PATTERSON, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHARLESTON, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
87 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK9315MMSI 368102480 · active · compulsorily equipped · granted 28 June 2019, expires 28 June 2029
WDK4664MMSI 367368970 · cancelled · compulsorily equipped · granted 6 September 2018, cancelled 13 May 2019
WCY6342MMSI 367368970 · terminated · compulsorily equipped · granted 17 July 2008, cancelled 4 September 2018
WCZ4495MMSI not assigned · expired · voluntarily equipped · granted 12 August 1999, cancelled 17 October 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

8 May 2026 Deficiency Check · Vessel Attendance · Annual Inspection · MSP Additional Oversight - Risk Assessment · MTSA Verification
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8369329
21 April 2025 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8117198
10 January 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8060773
25 August 2024 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7989075
25 August 2024 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7996185
25 April 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7901087
13 February 2024 COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7862806
10 May 2023 Deficiency Check · Administrative Inspection · MTSA Verification · Annual Inspection · In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7685528
20 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7612060
27 April 2022 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7439363
4 September 2021 In-Service Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7304124
7 June 2021 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7221480
24 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7205110
23 February 2021 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7144767
10 August 2020 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7176712
5 November 2019 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6849620
4 November 2019 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6849378
13 August 2019 Examination of Repairs · In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6780898
19 February 2019 DAPI Audit · Deficiency Check · COI Inspection · Security Plan Review - VSP · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6628197
15 June 2018 Administrative Inspection · Drydock Exam · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6443842
15 October 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6304258
28 June 2017 MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6189292
25 June 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6206743
11 April 2017 Deficiency Check · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6122716
8 August 2016 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5968431
27 June 2016 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5921740
7 June 2016 Drydock Exam · Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5899803
31 March 2016 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5844375
27 May 2014 Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4872114
21 March 2014 Administrative Inspection · Drydock Extension
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 4831933
20 July 2012 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 4418863
29 June 2012 Periodic Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4376260
29 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3717918
7 April 2009 MTSA Verification · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3447905
28 March 2008 Drydock Exam
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3173126
6 November 2007 MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3090330
15 March 2007 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2888618
6 July 2006 Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2703257
8 March 2006 Hull Examination
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2598414
17 February 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2587047
28 January 2005 MTSA Verification · Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2282321
11 March 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2020235
28 January 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1986728
21 November 2002 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1708974
28 October 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1689951
27 February 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1489750
8 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075686
9 October 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1425219
17 February 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1378991
28 October 1999 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1429264
23 November 1998 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 806897
28 October 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1468891
17 November 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1383719
14 October 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1112053
24 February 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1100106
4 December 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1093329
24 September 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1142054
29 September 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1191863
31 January 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143530
12 January 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863112
15 December 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830878
14 October 1994 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175576
7 October 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861445
13 October 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 830193
17 November 1992 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1469746
29 October 1992 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132750
22 October 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954266
19 August 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941864
10 July 1992 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1259435
16 June 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265740
16 April 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261640
12 December 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265289
2 August 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933166
19 February 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225348
12 December 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1215454
15 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 929116
14 February 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230404
6 February 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1227910
8 March 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 967321
22 February 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346051
11 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1353150
19 February 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330378
27 March 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319369
27 March 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336681
17 July 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988901
23 May 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989244
19 May 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301823

Deficiency record · 177

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2026 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. MIs were unable to test fire pump due to hole in firemain piping.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2026
Resolved 18 May 2026
Resolution: Verified fire pump out put
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2026 Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended. MI observed corrosion in firemain in the water tank void space leading to a hole in the piping. 46 CFR 181.15-5(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2026
Resolved 17 June 2026
Resolution: Permanent repairs inspected SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2026 Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. The technician conducting the inspection and providing the certification must not be the vessel's owner, operator, master, or employee or their affiliates. Additionally, the vessel owner, operator, or ship's master must certify in the station log that the inspection was satisfactory. Vessel did not have valid certificate onboard. Restricted to 1000 feet from shore until provided. 47 CFR 80.59(a)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 June 2026
Resolved 21 May 2026
Resolution: New Safety Radiotelephony Certificate issued
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. MIs observed deteriorated and detached waterlight line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 18 May 2026
Resolution: replaced waterlight line
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026 Resolved
Each ring life buoy on a vessel must be approved Be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. MIs observed deteriorating life line on Type Approved lifebuoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 18 May 2026
Resolution: replaced ring buoy lines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection. MIs observed 02 extinguishers not secured in a mounted bracket.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: O/o provided photos of galley and engine room fire extinguishers properly mounted in brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2026 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil all propulsion engine and located to be as in the view of the operator. MI observed jacket water gauge to be covered.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 17 June 2026
Resolution: new jacket water gauge installed, SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2026 Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support. MI observed bundles being secured and supported by plastic tie wraps. Proper metal support must be provided
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 22 May 2026
Resolution: O/o provided photos of plastic cable ties removed and replaced with steel bands.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 May 2026 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. MIs noticed the wire run in the stbd aft bulkhead in the water tank void was loose and not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 21 May 2026
Resolution: O/o used fire caulk to seal wire run from the Water Tank space into the engine room restoring watertight integrity.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2026 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Observed wingnut on battery terminal not considered to be permanent type connection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: O/o submitted photos of battery terminals with permanent type connections.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 13 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors. MI observed cable hanging in bilge on STBD side of engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 22 May 2026
Resolution: O/o provided photo of cable terminated and removed from bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2025 Resolved
The design, construction, and original testing of such approved unfired pressure vessels must meet the applicable requirements of subchapter F (Marine Engineering) of this chapter. Vessel unfired pressure vessels are overdue for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 July 2025
Resolution: MI's visually inspected the interiors of both pressure vessels on 05May2025. O/O replaced pressure relief valves on both UPVs with ASME stamped valves.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 April 2025 Resolved
Penetrations of required watertight bulkheads by any rigid plastic pipe systems are prohibited. Watertight bulkhead between engine room and lazarette has a non-metallic through hull fitting. 46 CFR 182.40-1 (1) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: O/O screwed a metal cap onto the bulkhead penetration. See deficiency documents for picture.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Vessel has plastic ties instead of metal fittings holding wires to the overhead in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: Flame proof wire ties installed in the engine room. See deficiency documents for picture.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2025 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Maximum number of allowable passengers on the upper deck is not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: Passenger label installed near stairs to indicate maximum number of passengers on the upper deck. See deficiency documents for picture.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and Coast Guard Light List. Charts and light list are not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: Updated chart placed on the vessel. See deficiency documents for picture.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 August 2024 Resolved
A self-propelled vessel must meet the applicable for main and auxiliary steering appartus in subchapters F. Main steering gear gear and rudder stock must be of adequate strength for and capable of steering the vessel at maximum ahead service speed. Vessel experienced loss of hydraulic fluid steering while transiting the Charleston Harbor. Additional tests and report provided by 3rd party technician to satisfaction of attending marine inspector required prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2024
Resolution: replaced failed hose with hard piping for steering system in void #3
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 April 2024 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel reported minor damage after collision with CAROLINA BELLE. 46 CFR 176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: MI attended vessel and conducted satisfactory damage survey.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Exposed wires in galley overhead and port side of engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 26 February 2024
Resolution: Vessel rep sent photos of the removed wires in both areas.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Missing 3 type I life jackets from the required 361 needed onboard vsl.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 26 February 2024
Resolution: Vessel provided photos of new lifejackets with proper markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2024 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers. Additional child-size life jackets were not marked with vessel name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 26 February 2024
Resolution: Vessel provided photos showing life jackets have been marked properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2023 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Hole in bilge piping system in the engine room. All bilge suctions need to be tested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: Replaced pipe and tested all bilge suctions with PTO and fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2023 Resolved
mechanically propelled "L" vessels shall comply with the provisions of Subchapter F of this chapter. Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference; see 46 CFR 56.01–2) and may be installed only in vital and nonvital fresh and salt water systems. Nonmetallic flexible hose must have factory-assembled end fittings requiring no further adjustment or field attachable fittings. Hose end fittings must comply with SAE J1475 Flexible hose in bilge system do not meet SAE and are not needed for flexibility.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: Removed all hoses and replace one hose with J1942 hose with j1475 jic fittings.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2023 Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Flares expired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2023
Resolution: Vessel placed proper flares inservice.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2023 Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per §177.30-7 of this subchapter. E lights in head area were not operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: E light switch was in the off position
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 May 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Both shaft guards were removed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: shaft covers were reinstalled
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 May 2023 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 mm (2 inches) high: "EMERGENCY EXIT, KEEP CLEAR", unless such markings are deemed unnecessary by the cognizant [name withheld] on engine room scuttle top side.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: labeled emergency escape
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023 Resolved
the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory. Hydraulic leak present in lazerette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 22 May 2023
Resolution: Received vendor report that hydraulic leak is repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023 Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Port MDE has broken exhaust hangers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 22 June 2023
Resolution: Hangers were replaced and exhaust leak corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023 Resolved
For items not covered by standards in this subchapter,inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. 2 A/C seawater pumps and motors and 1 Stbd not mounted at bases and only supported by piping. 1 port pump needs pipe plug since discontinued and still connected to sea chest.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 12 June 2023
Resolution: mounted pumps
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023 Resolved
For items not covered by standards in this subchapter,inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. P/W head tanks are being discontinued yet have exposed wiring and pump lying in bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 22 May 2023
Resolution: P/W head pumps removed and wiring was placed in junction boxes since no longer ties into the pumps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2023 Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Lighting fixture main deck near bar missing protective bulb cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 18 May 2023
Resolution: Vessel replaced light fixture.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. first aid kit present but missing contents per 160.041
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 16 May 2023
Resolution: Vessel placed an approved 160.041 first aid kit in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2023 Resolved
Each life jacket kept in a stowage container must be readily available. Second deck life jacket locker wouldn't open, latch was removed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Removed broken latch
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2023 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Missing cover on Port mde terminal board
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: replaced terminal board with new board with cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 April 2022 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by FCC, as set forth in 47 CFR part 80. Vessel does not have Safety radio or Bridge to Bridge certificate. 46 CFR 121.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 30 June 2022
Resolution: Vessel obtained relevant certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2022 Resolved
Be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. Life rings on aft deck, fore deck, and 2nd deck mezzanine were cracked and un-servicable. 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2022
Resolved 27 April 2022
Resolution: Replaced and remarked life rings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2022 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight component. 46 CFR 182.25. Discharge line has a hole in it.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 21 June 2022
Resolution: Vessel replaced the holed pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 April 2022 Resolved
Vital systems that are automatically or remotely controlled must be provided with instrumentation to monitor system parameters necessary for the safe and effective operation of the system. Crew was unable to test SSDG overspeed, low L/O pressure and high J/W temp.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 21 June 2022
Resolution: Received report from Nixon Power that tests were satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2022 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. E/R breaker panel missing blanks. 46 CFR 120.330
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: Blank installed in breaker pannel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2022 Resolved
Proposed alterations shall be approved by the Officer in Charge, Marine Inspection. Windows on main deck were replaced with plywood. 46 CFR 176.20
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: Windows were properly replaced and plywood was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2022 Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. The letter sets forth conditions of operation. Stability letter states FR 21 is WTB. Sewage piping in bhd is not fully welded. Complete and conduct NDT. 46 CFR 170.120
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: Sewage piping in bhd was fully welded and verified through visual inspection.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 27 April 2022 Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel has replaced machinery that can effect deviation of compass and no deviation card is present. 46 CFR 121.402
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 5 December 2022
Resolution: Vessel provided photograph of deviation table installed. Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2022 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew spaces located below the main deck. Engine room needs another emergency light fitted to facilitate egress from back of E/R. 46 CFR 120.432
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: O/O stated wrong bulb was installed, should be verified next annual exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2022 Resolved
The Certificate of Inspection must be posted under glass or suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where passenger observation is likely. 46 CFR 115.302
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: The Certificate of Inspection was correctly posted underglass and readily available to passengers.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 April 2022 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast placard missing. 46 CFR 121.506
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: Installed in the vacinity of the helm.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 April 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Missing kit or equivalent contents. 46 CFR 121.710
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: O/O states replaced missing contents.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 April 2022 Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. Holes in pilot house top and front present. 46 CFR 176.25
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: Holes in pilot house top and front welded for sufficient correction.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 April 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide Tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Missing up to date charts and publications. 46 CFR 121.240
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: O/O placed up to date chart and nav pubs in service.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 April 2022 Resolved
AIS must be maintained in effective operating condition. AIS broadcast information according to NAVCEN is incorrect. 33 CFR 164.46
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 5 December 2022
Resolution: Vessel provided documentation of properly operating AIS.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2021 Resolved
A power-driven fire pump shall be installed on each mechanically propelled "L" vessel. The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. Fire pump psi dropped to 50/55 psi when hose was engaged. Vessel restricted to less than 150 passengers until a satisfactory test of 60 psi is achieved with the fire main in the presence of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 2 September 2021
Resolution: conducted satisfactory test of the fire main
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2021 Resolved
All piping, valves, and fittings on the fire main shall be in accordance with good marine practice and suitable for the purpose intended. Vessel's fire main is leaking in three areas. Vessel restricted to less than 150 passengers until the fire main is hydrostatically tested to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2021
Resolved 2 September 2021
Resolution: Hydrostatic test was completed satisfactorily
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021 Resolved
At each vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel has two holes on the fire main. One is located in the engine room and the other in void space 4. Prior to carrying passengers vessel must repair and conduct hydrostatic test of fire main to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2021
Resolution: Completed hydro and functional test
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 25 May 2021 Resolved
On a vessel of more than 65 feet in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] system did not operate. The voltage on the bridge was reading 212V. Must prove proper operation of system prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2021
Resolution: Corrected wiring in SSDG which corrected voltage
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021 Resolved
Repairs or alterations to the machinery that affect the safety of the vessel must not be made without the approval of the OCMI. Vessel replaced air receivers while in drydock at Thunderbolt. Vessel's air receivers did not have ASME "U" stamp, vessel to submit to USCG the Manufacturers Data Report (Form U1A).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Recieved U1A for the pressure vessels
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2021 Resolved
At each inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. Vessel has a hydraulic leak on the steering system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Replaced o-ring that was source of the leak
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021 Resolved
The minimum capacity of the power fire pump shall be 50 gals per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet shall be fitted with a pressure gage. Vessel missing gage on fire main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Installed fire main pressure gauge
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 May 2021 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Vessel's oil pressure gage for the MDE on bridge is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 3 September 2021
Resolution: analog gauge was installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 May 2021 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1 inch letters: "Emergency Exit, Keep Clear". Various escapes/exits on vessel are not labeled or only labeled on one side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Marked both side of emergency exits
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 May 2021 Resolved
At each inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. Vessel's watertight integrity is compromised due to a condensate drain in the lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Condensated drain was sealed to the deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2021 Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline must be at least 60 feet in length. Vessel is missing line on ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Life line was placed in service
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 May 2021 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel is missing one portable light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Portable light was placed in service
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021 Resolved
Nonmetallic piping shall not be used in gasoline and diesel fuel systems. Vessel has a PVC fill on fuel line and the fuel shut off needs support.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Pvc was removed and replaced with aluminum
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2021 Resolved
Batteries shall be located so that they are effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Battery box missing cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2021
Resolution: Battery box cover and battery charger drip shield was installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 May 2021 Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Hatches in the fore peak and the lazarette are leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 3 September 2021
Resolution: Hatch was adjusted and vessel rep [name withheld] attested to the repair.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2021 Resolved
Each vessel must carry at least one rescue boat unless the OCMI determines that the vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Vessel's rescue platform is too long, vessel to provide plan to correct to the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 3 September 2021
Resolution: Vessel shorten the rescue platform.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 August 2020 Resolved
"L" vessels over 65 feet in accordance with Table 182.25-10(a) must be provided with 2 fixed power pumps. Bilge pump inoperable. Fire pump unable to dewater spaces. Prove proper operation of bilge pump arrangement prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2020
Resolution: new impeller installed
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 August 2020 Resolved
General construction for vessels that carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H, including Table 72.05-10(E). Demonstrate proper A-60 boundary between engine room and accommodation space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 8 September 2020
Resolution: a-60 insulation re-installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2020 Resolved
An adult life jacket must be provided for each person carried on board. Missing (33) adult life jackets. Restricted to carriage of 320 pax until proof that one life jacket provided for each person onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 August 2020 Resolved
A self-propelled vessel that is certificated to carry more than 150 passengers is required a Class A AIS. Currently only has a Class B AIS onboard. Prove proper installation of Class A AIS device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 August 2020 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR." Emergency exits not labeled. Prove proper labeling of emergency exits.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2020
Resolved 14 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2020 Resolved
Covered metal trash containers shall be provided in lounge areas. Vessel shall prove proper installation of metal trash cans.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2020
Resolved 14 August 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 February 2019 Resolved
Each vessel must be provided with a visual and audible alarm to indicate high water in unmanned spaces. The audible alarm only works for 1 of 5 spaces. The audible and visual alarm for the lazarette is not operational. Make repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2019
Resolution: All alarms were tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2019 Resolved
Each crew member must be enrolled in a random drug testing program and pre-employment tested. One crewmember on the day of inspection has not been pre-employment tested and is not added to the company list. Crew member is not permitted to work on vessel until achieving these items.
Action required: 705 - Other - as specified
Resolved 26 March 2019
Resolution: All current crew members are enrolled in a random drug testing program.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 February 2019 Resolved
Lifejacket placards for donning instructions shall be posted in a conspicuous place accessible to passengers. No placards are posted. Post one port and stbd in main cabin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2019
Resolution: Placards were posted both port and starboard at main entry doors.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 February 2019 Resolved
Master and crew shall perform man overboard and fire drills. Drills not performed due to high winds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 February 2019 Resolved
Vessel is required class A AIS. Install approved class A AIS or request exception per deviations from rules (33CFR164.55). VSL currently operates in a confined geographic area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2019 Resolved
Float switch wire has unapproved splice. Make appropriate repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Splice has been properly installed.
Lifesaving › Lifebuoys › Serviceable
Issued 28 June 2017 Resolved
Replace the ringbuoy on the 02 deck bow.
Due 28 July 2017
Resolved 25 July 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 June 2017 Resolved
Provide reflective tape on 2 ringbuoys on main deck.
Due 28 July 2017
Resolved 25 July 2017
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 28 June 2017 Resolved
Troubleshoot and repair open grounds in three outlets on the 02 deck.
Due 28 July 2017
Resolved 25 July 2017
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 28 June 2017 Resolved
Provide outlet cover for broken cover on 02 deck.
Due 28 July 2017
Resolved 25 July 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 June 2017 Resolved
Remove hose between the bhd and valve on the waste line in the #2 void.
Due 28 July 2017
Resolved 25 July 2017
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 28 June 2017 Resolved
Troubleshoot and repair ground guage on switchboard.
Due 1 January 2018
Resolved 19 February 2019
Resolution: From discussions with O/O and manufacturer it is determined that the system is operating as designed.
Engineering › Bilge Water Management System › Piping
Issued 28 June 2017 Resolved
Properly repair the bilge pipe in the #2 void prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Resolution: Recieved photos and statement from Capt of vsl that attest to proper repairs and testing.
Stability › Watertight Integrity › General
Issued 28 June 2017 Resolved
Properly cap two open deck penetrations on the 02 weather deck.
Due 28 July 2017
Resolved 25 July 2017
Fire Fighting › Fire Pumps › Gland Sealing
Issued 28 June 2017 Resolved
Make repairs to fire pump seal.
Due 28 July 2017
Resolved 25 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2017 Resolved
Remove yellow drop wire from engine room panel.
Due 28 July 2017
Resolved 25 July 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 June 2017 Resolved
Renew both hydraulic hose on steering system in lazerette. Use SAE J1942 hose.
Due 28 July 2017
Resolved 25 July 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 28 June 2016 Resolved
Replace stbd exhaust flange in lazarette space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Resolution: Cleared due to duplicate entry; extended due date of primary entry to 31 DEC 2016.
Engineering › Pressure Vessel › Relief Valve
Issued 27 June 2016 Resolved
Prove proper operation of both pressure vessel relief valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Engineering › Pressure Vessel › Weld
Issued 27 June 2016 Resolved
Open pressure vessels (2) for internal exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Fire Fighting › Fire Pumps › Pressure
Issued 27 June 2016 Resolved
Prove proper operatin of fire pump (60psi).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 28 June 2016
Resolution: Verified operation of firepump.
Engineering › Bilge Water Management System › Not Operational
Issued 27 June 2016 Resolved
Prove proper operation of installed bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 28 June 2016
Resolution: Verified operation of bilge system.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 27 June 2016 Resolved
Prove proper operation of main engine shut downs from pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 June 2016 Resolved
Replace 03 ring buoys which have deteriorated grab lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 June 2016 Resolved
Ensure 2" emergency exit signs are posted throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 June 2016 Resolved
Replace 05 B-II fire extinguisher brackets with approved 809 or 895 brackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Stability › Watertight Integrity › General
Issued 27 June 2016 Resolved
Replace watertight cover on 02 deck port flood lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2016 Resolved
Remove or properly secure dead end wires on stbd main and port aft engine room by A/C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 June 2016 Resolved
Secure door to constavolt in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Lifesaving › Lifebuoys › Serviceable
Issued 27 June 2016 Resolved
Provide corrosion resistant clip for lifeline on bridge deck ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 June 2016 Resolved
Properly mount and wire power inverter for radar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2016 Resolved
Ensure all wire connection in bridge console have retaining type connectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 27 June 2016 Resolved
Remove and do not use any portable cables, or electrical splitters on bridge, 01 deck, and dance floor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 June 2016 Resolved
Ensure all crew are enrolled in company drug testing program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 June 2016 Resolved
Crop and renew the deteriorated exhaust pipe flange on the stbd outboard exhaust pipe at the transom connection in the lazarette.
Due 31 December 2016
Resolved 11 April 2017
Resolution: Repairs made IAW the builders specs.
Electrical › Electric Supply System (service) › Cable
Issued 29 June 2012 Resolved
Remove wire nuts on the water heater electrical supply and install wire through proper clamp.
Due 19 July 2012
Resolved 19 July 2012
Accommodation/Occupational Safety › Potable Water System › General
Issued 29 June 2012 Resolved
Mount the potable water pump to the deck in the engineroom.
Due 19 July 2012
Resolved 19 July 2012
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 June 2012 Resolved
Mount the A/C water pump to the deck in the engineroom.
Due 19 July 2012
Resolved 19 July 2012
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 29 June 2012 Resolved
Mount the toilet water pump to the deck located in the engineroom
Due 19 July 2012
Resolved 19 July 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 June 2012 Resolved
Replace the hose for exhaust cooling water on the starboard engine
Due 19 July 2012
Resolved 19 July 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 29 June 2012 Resolved
Ensure all electrical panels accessible to passengers are able to be locked.
Due 19 July 2012
Resolved 19 July 2012
Fire Fighting › Means of Escape › Escape Route Signs
Issued 29 June 2012 Resolved
Provide emergency exit signs for hatch in male head, one above deck and one on the door to the head.
Due 19 July 2012
Resolved 19 July 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 June 2012 Resolved
Provide proper light bulb for starboard nav light.
Due 19 July 2012
Resolved 19 July 2012
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2012 Resolved
Replace the forward life ring buoy on upper deck due to deteriorated grab line
Due 19 July 2012
Resolved 19 July 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 June 2012 Resolved
Replace the battery in the waterlight on the upper deck ring buoy
Due 19 July 2012
Resolved 19 July 2012
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Closure Devices
Issued 29 June 2012 Resolved
Replace the closure devices in all goose neck vents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2012
Stability › Watertight Integrity › General
Issued 29 June 2012 Resolved
Due to deterioration, crop and renew to good metal the lower portion of the bulkhead between the engine room and lazarette. A repair proposal is to be submitted prior to commencing repairs.
Action required: 705 - Other - as specified
Due 15 January 2013
Resolved 8 March 2013
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 March 2010 Resolved
Lap in disks on (5) sea valves and prove proper seating with blue fit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 March 2010 Resolved
Repair all fractures in the hand rail on fore peak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Construction/Loadline › Hull › Transverse Frame
Issued 29 March 2010 Resolved
Repair one fracture in forepeak IWO under deck frame as discussed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Stability › Watertight Integrity › General
Issued 29 March 2010 Resolved
Clean or replace hatch gaskets and properly adjust water tight hatches throughout vessel. 46 CFR 116-1160.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Fire Fighting › Fire Main › Valves
Issued 29 March 2010 Resolved
Remove electrical tape and corrosion from the skin valve connection in the engine room port side forward (fire pump overboard).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Construction/Loadline › Structures › Transverse Bulkhead
Issued 29 March 2010 Resolved
Scale off all epoxy coating on forward bulkhead IWO steering room and provide ultrasonic thickness readings IAW 46 CFR 116.300 (b).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Engineering › Freshwater System (air cooling) › Hose
Issued 29 March 2010 Resolved
Renew raw water hoses for air conditioning cooling system IWO steering space IAW 46 CFR 119.720 and 46 CFR Sub F (CG approved hoses).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Lifesaving › Lifebuoys › Serviceable
Issued 29 March 2010 Resolved
Renew Ring Life buoys as needed IAW 46 CFR 117.70.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 March 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 March 2010 Resolved
Install guards over both propeller shafts IWO the engine room IAW 46 CFR 116.960 NLT 29APR2010.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 31 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 March 2010 Resolved
Renew the starboard main engine exhaust pipe and flange IWO the steering room IAW 46 CFR 119.430 NLT 29APR10.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 31 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 March 2010 Resolved
Repair all main engine exhaust pipe hangers IWO steering space NLT 29APR10.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 31 March 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 29 March 2010 Resolved
Install pipe insulation on all exhaust piping and mufflers IWO steering space IAW 46 CFR 116.970 NLT 29APR10.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 31 March 2010
Engineering › Steering Gear System › Helix Shaft
Issued 29 March 2010 Resolved
Renew the linear activator (RAM) IWO the main steering system NLT 28APR10, IAW 46 CFR 119.600.
Action required: 705 - Other - as specified
Due 29 April 2010
Resolved 31 March 2010
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 29 March 2010 Resolved
Install rail courses IWO upper deck IAW 46 CFR 116.900 (f) (1) and 177.35-1 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2010
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 April 2009 Resolved
Provide proof that the crew has received EAP training.
Due 21 April 2009
Resolved 17 April 2009
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 7 April 2009 Resolved
Provide proof that the Master has received one hour supervisor training.
Due 21 April 2009
Resolved 17 April 2009
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 7 April 2009 Resolved
Provide proof that the marine employer has contact information for the substance abuse professional.
Due 21 April 2009
Resolved 17 April 2009
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 7 April 2009 Resolved
Provide proof that the MIS report has been submitted.
Due 21 April 2009
Resolved 17 April 2009
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 April 2009 Resolved
Provide proof of contract with the consortium.
Due 21 April 2009
Resolved 17 April 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 April 2009 Resolved
Provide the vessel with a copy of the CG Light List.
Due 7 May 2009
Resolved 11 June 2009
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 7 April 2009 Resolved
Post exit signs throughout the passenger accommodation spaces in a manner in which they can be seen from any location within the space.
Due 7 May 2009
Resolved 11 June 2009
Construction/Loadline › Penetrations › Weld
Issued 7 April 2009 Resolved
Remove two plastic pipe deck penetrations IWO the engine room overhead and replace with metallic pipe.
Due 7 May 2009
Resolved 11 June 2009
Electrical › Electric Supply System (service) › Cable
Issued 7 April 2009 Resolved
Remove the dead end wires IWO the engine room.
Due 7 May 2009
Resolved 11 June 2009
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 April 2009 Resolved
Repair or replace the latch on the stairway door on the main deck.
Due 7 May 2009
Resolved 11 June 2009
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 March 2007 Resolved
Exhaust leak in steering gear compartment.
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 25 April 2007
Resolution: Satisfactory repairs conducted on exhaust piping in steering gear compartment
Engineering › Thrusters › Motor
Issued 15 March 2007 Resolved
Bow Thurster is inoperable.
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 25 April 2007
Resolution: Conducted satisfactory operational test of bow thruster
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 15 March 2007 Resolved
Unable to conduct MOB drills due to exhaust leak preventing vessel from operating. Drills to be conducted upon completion of repairs.
Action required: 705 - Other - as specified
Resolved 25 April 2007
Resolution: Satisfactory Man Overboard Drills conducted
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 February 2006 Resolved
Audio alarm of bilge system not working.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 February 2006
Resolved 17 February 2006
Resolution: Problem corrected before departure of marine inspector. Relay replaced.
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 January 2005 Resolved
PROVIDE CREW FOR DRILLS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 November 2007
Resolved 6 November 2007
Resolution: Conducted drills
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 28 January 2005 Resolved
RENEW HYDROSTAIC RELEASE SERVING EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2005
Resolved 9 February 2005
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 28 January 2005 Resolved
SHOW PROOF OF EPIRB REGISTRATION.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 January 2005 Resolved
SHOW PROOF OF COMPLIANCE WITH CG DRUG TESTING REGS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2005
Lifesaving › Visual Distress Signals (General)
Issued 28 October 2002 Resolved
RENEW BATTERY SERVING EPIRB BEFORE VESSEL SAILS ON A COASTWISE ROUTE OR NLT 28NOV2002. LEGACY COMPONENT DESC: Condition
Due 28 November 2002
Resolved 21 November 2002
Lifesaving
Issued 28 October 1999 Resolved
PROPERLY STENCIL 01 ADULT PFD.
Condition: Unknown
Due 29 October 1999
Resolved 24 November 1999
Fire Fighting
Issued 28 October 1999 Resolved
PROVE PROPER OPERATION OF FIRE PUMP.
Condition: Unknown
Due 29 October 1999
Resolved 24 November 1999
Fire Fighting
Issued 28 October 1999 Resolved
VESSEL SHALL NOT OPERATE UNTIL FIRE PUMP MANIFOLD IS PROPERLY REPAIRED.
Condition: Unknown
Due 29 October 1999
Resolved 24 November 1999
Electrical
Issued 28 October 1999 Resolved
PROPERLY SECURE WIRING AND JUNCTION BOX FOR SANITARY PUMP IN ENGINE ROOM.
Condition: Unknown
Due 29 October 1999
Resolved 24 November 1999
Lifesaving
Issued 28 October 1999 Resolved
REPLACE REFLECTIVE TAPE ON LOWER LIFEFLOAT STBD SIDE.
Condition: Unknown
Due 29 October 1999
Resolved 24 November 1999
Electrical
Issued 28 October 1999 Resolved
PROVIDE BREAKER BLANK IN EMPTY LOCATION IN E/R DISTRIBUTION PANEL.
Condition: Unknown
Due 29 October 1999
Resolved 24 November 1999
Lifesaving
Issued 28 October 1998 Resolved
VESSEL IS RESTRICTED TO CARRIAGE OF 176 TOTAL PERSONS ON COASTWISE NMT 20 VOYAGES, AND 293 TOTAL PERSONS ON LAKES, BAYS, AND SOUNDS VOYAGES. RESTRICTION IS APPLICABLE UNTIL SUFFICIENT ADDITIONAL LIFE FLOATS OR BUOYANT APPARATUS ARE PROVIDED.
Condition: Unknown
Due 28 October 1998
Resolved 28 October 1998
Construction/Loadline
Issued 31 January 1995 Resolved
REPAIR REACH ROD FOR FOREPEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Construction/Loadline
Issued 31 January 1995 Resolved
INSTALL STUFFING TUBE IN FORWARD BULKHEAD IN LAZARETTE & TARBOARD SIDE.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Construction/Loadline
Issued 31 January 1995 Resolved
PERMANENTLY LABEL FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Engineering
Issued 15 December 1994 Resolved
PERMANENTLY LABEL FUEL SHUT-OFF VALVE. THESE REQUIREMENTS MAY BE CLEARED WITH A SIGNED STATEMENT FROM THE VESSEL MASTER STATING THAT WORK HAS BEEN COMPLETED. FAX STATEMENT TO MIO NEW YORK ATTN: JONATHAN MCDERMOTT AT [phone withheld].
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Engineering
Issued 15 December 1994 Resolved
REPAIR REACH ROD FOR FOREPEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Electrical
Issued 15 December 1994 Resolved
INSTALL STUFFING TUBE IN FORWARD BULKHEAD IN LAZARETTE, STARBOARD SIDE.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994
Documentation
Issued 14 October 1994 Resolved
DRYDOCK VESSEL FOR EXAMINATION NOT LATER THAN 16 DEC 94. A (45) FORTY FIVEDAY EXTENSION OF THE DRYDOCK INTERVAL HAS BEEN GRANTED EFFECTIVE 31 OCT 94._x001C_ _x001C_
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 7 October 1994 Resolved
MAKE PERMANENT REPAIRS TO BILGE MANIFOLD
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Lifesaving
Issued 7 October 1994 Resolved
RENEW WORN SEA PAINTER FOR LIFE FLOATS.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Lifesaving
Issued 7 October 1994 Resolved
CLEAN LIFE FLOATS / REPAINT AS NECESSARY.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Fire Fighting
Issued 7 October 1994 Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Documentation
Issued 29 October 1992 Resolved
PRIOR TO CARRYING PASSENGERS IN THE SAVANNAH, GA. MARINE INSPECTION ZONE YOU ARE TO CONTACT THE [name withheld] AT [phone withheld] AND PRESENT THIS VESSEL FOR EXAMINATION BY A COAST GUARD INSPECTOR.
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Construction/Loadline
Issued 22 October 1992 Resolved
REPAIR CRACKED WELD IN WAY OF STBD # FIVE FRAME AND DECK PLATE.
Condition: Unknown
Due 5 November 1992
Resolved 7 December 1992
Engineering
Issued 22 October 1992 Resolved
REPLACE PORT CUTLASS BEARINGS. PROVIDE OLD BEARINGS FOR EXAMINATION BY MARINE INSPECTOR OR PROOF OF PURCHASE OF NEW BEARINGS.
Condition: Unknown
Due 5 November 1992
Resolved 7 December 1992
Lifesaving
Issued 14 February 1990 Resolved
RENEWED PENDANTS ON LIFE FLOATS.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Accommodation/Occupational Safety
Issued 19 May 1986 Resolved
PROVIDE PREPURGE IN ACCORDANCE WITH 46CFR 63.10-20(C) ON BOTH DIESEL FIXED HEATING UNITS.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Fire Fighting
Issued 19 May 1986 Resolved
SATISFY STRUCTURAL FIRE PROTECTION PLAN APPROVAL COMMENTS OF 15MAY86 G-PRTTLETTER AND PROVIDE INFORMATION ON FIRE RETARDANT CARPETING INSTALLED PRIOR TO CARRYING MORE THAN 149 PASSENGERS.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986
Construction/Loadline
Issued 19 May 1986 Resolved
MAKE THE VESSEL AVAILABLE TO THE OFFICER IN CHARGE, MARINE INSPECTION, NEW YORK CITY, NY, PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 19 May 1986
Resolved 19 May 1986

Casualty record · 5

6 July 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2703257
25 June 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3536602
25 June 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6206743
7 June 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7221480
25 August 2024Routine · role: Involved in a Marine Casualty · activity 7996185
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ROYAL WINNER PRINCESS II (2006–2017). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.