07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2026
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet.
MIs were unable to test fire pump due to hole in firemain piping.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2026
Resolved 18 May 2026
Resolution: Verified fire pump out put
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 May 2026
Resolved
All piping, valves, and fittings shall be in accordance with good marine practice and suitable for the purpose intended.
MI observed corrosion in firemain in the water tank void space leading to a hole in the piping.
46 CFR 181.15-5(c)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2026
Resolved 17 June 2026
Resolution: Permanent repairs inspected SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 May 2026
Resolved
A certification that the ship has passed an inspection must be entered into the ship's log by the inspecting technician. The technician conducting the inspection and providing the certification must not be the vessel's owner, operator, master, or employee or their affiliates. Additionally, the vessel owner, operator, or ship's master must certify in the station log that the inspection was satisfactory.
Vessel did not have valid certificate onboard. Restricted to 1000 feet from shore until provided.
47 CFR 80.59(a)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 June 2026
Resolved 21 May 2026
Resolution: New Safety Radiotelephony Certificate issued
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
MIs observed deteriorated and detached waterlight line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 18 May 2026
Resolution: replaced waterlight line
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 May 2026
Resolved
Each ring life buoy on a vessel must be approved Be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant.
MIs observed deteriorating life line on Type Approved lifebuoy.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 18 May 2026
Resolution: replaced ring buoy lines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge, Marine Inspection.
MIs observed 02 extinguishers not secured in a mounted bracket.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: O/o provided photos of galley and engine room fire extinguishers properly mounted in brackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2026
Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil all propulsion engine and located to be as in the view of the operator.
MI observed jacket water gauge to be covered.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 17 June 2026
Resolution: new jacket water gauge installed, SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 May 2026
Resolved
Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of multiple cable installations, and not used as a means of support.
MI observed bundles being secured and supported by plastic tie wraps. Proper metal support must be provided
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 22 May 2026
Resolution: O/o provided photos of plastic cable ties removed and replaced with steel bands.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 May 2026
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight.
MIs noticed the wire run in the stbd aft bulkhead in the water tank void was loose and not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 21 May 2026
Resolution: O/o used fire caulk to seal wire run from the Water Tank space into the engine room restoring watertight integrity.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2026
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited.
Observed wingnut on battery terminal not considered to be permanent type connection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 27 May 2026
Resolution: O/o submitted photos of battery terminals with permanent type connections.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 13 May 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to prevent electrical ignition of flammable vapors.
MI observed cable hanging in bilge on STBD side of engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 22 May 2026
Resolution: O/o provided photo of cable terminated and removed from bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2025
Resolved
The design, construction, and original testing of such approved unfired pressure vessels must meet the applicable requirements of subchapter F (Marine Engineering) of this chapter.
Vessel unfired pressure vessels are overdue for inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 16 July 2025
Resolution: MI's visually inspected the interiors of both pressure vessels on 05May2025. O/O replaced pressure relief valves on both UPVs with ASME stamped valves.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 April 2025
Resolved
Penetrations of required watertight bulkheads by any rigid plastic pipe systems are prohibited.
Watertight bulkhead between engine room and lazarette has a non-metallic through hull fitting.
46 CFR 182.40-1 (1) (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: O/O screwed a metal cap onto the bulkhead penetration. See deficiency documents for picture.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
Vessel has plastic ties instead of metal fittings holding wires to the overhead in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: Flame proof wire ties installed in the engine room. See deficiency documents for picture.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck.
Maximum number of allowable passengers on the upper deck is not marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: Passenger label installed near stairs to indicate maximum number of passengers on the upper deck. See deficiency documents for picture.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 April 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts and Coast Guard Light List.
Charts and light list are not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2025
Resolved 2 May 2025
Resolution: Updated chart placed on the vessel. See deficiency documents for picture.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 August 2024
Resolved
A self-propelled vessel must meet the applicable for main and auxiliary steering appartus in subchapters F. Main steering gear gear and rudder stock must be of adequate strength for and capable of steering the vessel at maximum ahead service speed.
Vessel experienced loss of hydraulic fluid steering while transiting the Charleston Harbor. Additional tests and report provided by 3rd party technician to satisfaction of attending marine inspector required prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2024
Resolution: replaced failed hose with hard piping for steering system in void #3
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 April 2024
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs.
Vessel reported minor damage after collision with CAROLINA BELLE.
46 CFR 176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 April 2024
Resolution: MI attended vessel and conducted satisfactory damage survey.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 February 2024
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure.
Exposed wires in galley overhead and port side of engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 26 February 2024
Resolution: Vessel rep sent photos of the removed wires in both areas.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Missing 3 type I life jackets from the required 361 needed onboard vsl.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 26 February 2024
Resolution: Vessel provided photos of new lifejackets with proper markings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 February 2024
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers.
Additional child-size life jackets were not marked with vessel name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2024
Resolved 26 February 2024
Resolution: Vessel provided photos showing life jackets have been marked properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2023
Resolved
All vessels shall be provided with
a satisfactory arrangement for draining
any watertight compartment.
Hole in bilge piping system in the engine room. All bilge suctions need to be tested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: Replaced pipe and tested all bilge suctions with PTO and fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2023
Resolved
mechanically propelled "L" vessels shall comply with the provisions of Subchapter F of this chapter.
Nonmetallic flexible hose must be in accordance with SAE J1942 (incorporated by reference; see 46 CFR 56.01–2) and may be installed only in vital and nonvital fresh and salt water systems. Nonmetallic flexible hose must have factory-assembled end fittings requiring no further adjustment or field attachable fittings. Hose end fittings must comply with SAE J1475
Flexible hose in bilge system do not meet SAE and are not needed for flexibility.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: Removed all hoses and replace one hose with J1942 hose with j1475 jic fittings.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2023
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry: (1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and (2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant.
Flares expired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2023
Resolution: Vessel placed proper flares inservice.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2023
Resolved
Adequate emergency lighting automatically actuated upon failure of the main lighting system shall be fitted along the line of escape in vessels having lounge areas below the main deck as per §177.30-7 of this subchapter.
E lights in head area were not operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: E light switch was in the off position
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 May 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears,
machinery, etc.
Both shaft guards were removed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: shaft covers were reinstalled
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 May 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 mm (2 inches) high: "EMERGENCY EXIT, KEEP CLEAR", unless such markings are deemed unnecessary by the cognizant [name withheld] on engine room scuttle top side.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: labeled emergency escape
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023
Resolved
the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary
to determine that its condition is satisfactory.
Hydraulic leak present in lazerette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 22 May 2023
Resolution: Received vendor report that hydraulic leak is repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023
Resolved
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks.
Port MDE has broken exhaust hangers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 22 June 2023
Resolution: Hangers were replaced and exhaust leak corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023
Resolved
For items not covered by standards in this subchapter,inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice.
2 A/C seawater pumps and motors and 1 Stbd not mounted at bases and only supported by piping. 1 port pump needs pipe plug since discontinued and still connected to sea chest.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 12 June 2023
Resolution: mounted pumps
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 May 2023
Resolved
For items not covered by standards in this subchapter,inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice.
P/W head tanks are being discontinued yet have exposed wiring and pump lying in bilge.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 22 May 2023
Resolution: P/W head pumps removed and wiring was placed in junction boxes since no longer ties into the pumps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2023
Resolved
Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories,
Inc.
Lighting fixture main deck near bar missing protective bulb cover.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 18 May 2023
Resolution: Vessel replaced light fixture.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 May 2023
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
first aid kit present but missing contents per 160.041
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 June 2023
Resolved 16 May 2023
Resolution: Vessel placed an approved 160.041 first aid kit in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2023
Resolved
Each life jacket kept in a stowage container must be readily available.
Second deck life jacket locker wouldn't open, latch was removed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Removed broken latch
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2023
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment, and reasonably safe from electrical shock of personnel.
Missing cover on Port mde terminal board
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 18 May 2023
Resolution: replaced terminal board with new board with cover.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 April 2022
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by FCC, as set forth in 47 CFR part 80. Vessel does not have Safety radio or Bridge to Bridge certificate. 46 CFR 121.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 30 June 2022
Resolution: Vessel obtained relevant certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 April 2022
Resolved
Be approved in accordance with 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant. Life rings on aft deck, fore deck, and 2nd deck mezzanine were cracked and un-servicable. 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 April 2022
Resolved 27 April 2022
Resolution: Replaced and remarked life rings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 April 2022
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight component. 46 CFR 182.25.
Discharge line has a hole in it.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 21 June 2022
Resolution: Vessel replaced the holed pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 April 2022
Resolved
Vital systems that are automatically or remotely controlled must be provided with instrumentation to monitor system parameters necessary for the safe and effective operation of the system. Crew was unable to test SSDG overspeed, low L/O pressure and high J/W temp.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2022
Resolved 21 June 2022
Resolution: Received report from Nixon Power that tests were satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 April 2022
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. E/R breaker panel missing blanks. 46 CFR 120.330
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: Blank installed in breaker pannel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2022
Resolved
Proposed alterations shall be approved by the Officer in Charge, Marine Inspection. Windows on main deck were replaced with plywood. 46 CFR 176.20
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: Windows were properly replaced and plywood was removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 April 2022
Resolved
Except as provided in paragraph (b) of this section, each vessel must have a stability letter issued by the Coast Guard before the vessel is placed into service. The letter sets forth conditions of operation. Stability letter states FR 21 is WTB. Sewage piping in bhd is not fully welded. Complete and conduct NDT. 46 CFR 170.120
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: Sewage piping in bhd was fully welded and verified through visual inspection.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 27 April 2022
Resolved
Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Vessel has replaced machinery that can effect deviation of compass and no deviation card is present. 46 CFR 121.402
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 5 December 2022
Resolution: Vessel provided photograph of deviation table installed. Deficiency rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 April 2022
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew spaces located below the main deck. Engine room needs another emergency light fitted to facilitate egress from back of E/R. 46 CFR 120.432
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: O/O stated wrong bulb was installed, should be verified next annual exam.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 April 2022
Resolved
The Certificate of Inspection must be posted under glass or suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where passenger observation is likely. 46 CFR 115.302
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: The Certificate of Inspection was correctly posted underglass and readily available to passengers.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 April 2022
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Emergency broadcast placard missing. 46 CFR 121.506
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: Installed in the vacinity of the helm.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 April 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Missing kit or equivalent contents. 46 CFR 121.710
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: O/O states replaced missing contents.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 April 2022
Resolved
Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. Holes in pilot house top and front present. 46 CFR 176.25
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 30 June 2022
Resolution: Holes in pilot house top and front welded for sufficient correction.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 April 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide Tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Missing up to date charts and publications. 46 CFR 121.240
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 June 2022
Resolution: O/O placed up to date chart and nav pubs in service.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 27 April 2022
Resolved
AIS must be maintained in effective operating condition. AIS broadcast information according to NAVCEN is incorrect. 33 CFR 164.46
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 5 December 2022
Resolution: Vessel provided documentation of properly operating AIS.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2021
Resolved
A power-driven fire pump shall be installed on each mechanically propelled "L" vessel. The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. Fire pump psi dropped to 50/55 psi when hose was engaged. Vessel restricted to less than 150 passengers until a satisfactory test of 60 psi is achieved with the fire main in the presence of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2021
Resolved 2 September 2021
Resolution: conducted satisfactory test of the fire main
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 June 2021
Resolved
All piping, valves, and fittings on the fire main shall be in accordance with good marine practice and suitable for the purpose intended. Vessel's fire main is leaking in three areas. Vessel restricted to less than 150 passengers until the fire main is hydrostatically tested to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 June 2021
Resolved 2 September 2021
Resolution: Hydrostatic test was completed satisfactorily
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021
Resolved
At each vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel has two holes on the fire main. One is located in the engine room and the other in void space 4. Prior to carrying passengers vessel must repair and conduct hydrostatic test of fire main to the satisfaction of the attending marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2021
Resolution: Completed hydro and functional test
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 25 May 2021
Resolved
On a vessel of more than 65 feet in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members [name withheld] system did not operate. The voltage on the bridge was reading 212V. Must prove proper operation of system prior to carrying passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 September 2021
Resolution: Corrected wiring in SSDG which corrected voltage
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021
Resolved
Repairs or alterations to the machinery that affect the safety of the vessel must not be made without the approval of the OCMI. Vessel replaced air receivers while in drydock at Thunderbolt. Vessel's air receivers did not have ASME "U" stamp, vessel to submit to USCG the Manufacturers Data Report (Form U1A).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Recieved U1A for the pressure vessels
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2021
Resolved
At each inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. Vessel has a hydraulic leak on the steering system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Replaced o-ring that was source of the leak
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 May 2021
Resolved
The minimum capacity of the power fire pump shall be 50 gals per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet shall be fitted with a pressure gage. Vessel missing gage on fire main.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Installed fire main pressure gauge
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 May 2021
Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Vessel's oil pressure gage for the MDE on bridge is inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 3 September 2021
Resolution: analog gauge was installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 May 2021
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1 inch letters: "Emergency Exit, Keep Clear". Various escapes/exits on vessel are not labeled or only labeled on one side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Marked both side of emergency exits
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 May 2021
Resolved
At each inspection all observed unsafe practices, fire hazards and other hazardous situations must be corrected. Vessel's watertight integrity is compromised due to a condensate drain in the lazarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Condensated drain was sealed to the deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2021
Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline must be at least 60 feet in length. Vessel is missing line on ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Life line was placed in service
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 May 2021
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel is missing one portable light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Portable light was placed in service
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021
Resolved
Nonmetallic piping shall not be used in gasoline and diesel fuel systems. Vessel has a PVC fill on fuel line and the fuel shut off needs support.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 2 September 2021
Resolution: Pvc was removed and replaced with aluminum
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 25 May 2021
Resolved
Batteries shall be located so that they are effectively screened by a cage or similar structure to minimize the danger of accidental spark through dropping a metal object across terminals. Battery box missing cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 September 2021
Resolution: Battery box cover and battery charger drip shield was installed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 25 May 2021
Resolved
The construction and arrangement of the vessel must allow the safe operation of the vessel giving consideration to provisions for a seaworthy hull. Hatches in the fore peak and the lazarette are leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 3 September 2021
Resolution: Hatch was adjusted and vessel rep [name withheld] attested to the repair.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2021
Resolved
Each vessel must carry at least one rescue boat unless the OCMI determines that the vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Vessel's rescue platform is too long, vessel to provide plan to correct to the USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 3 September 2021
Resolution: Vessel shorten the rescue platform.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 August 2020
Resolved
"L" vessels over 65 feet in accordance with Table 182.25-10(a) must be provided with 2 fixed power pumps. Bilge pump inoperable. Fire pump unable to dewater spaces. Prove proper operation of bilge pump arrangement prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2020
Resolution: new impeller installed
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 August 2020
Resolved
General construction for vessels that carry more than 150 passengers shall meet the requirements of subpart 72.05 of Subchapter H, including Table 72.05-10(E). Demonstrate proper A-60 boundary between engine room and accommodation space.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 20 August 2020
Resolved 8 September 2020
Resolution: a-60 insulation re-installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 August 2020
Resolved
An adult life jacket must be provided for each person carried on board. Missing (33) adult life jackets. Restricted to carriage of 320 pax until proof that one life jacket provided for each person onboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 August 2020
Resolved
A self-propelled vessel that is certificated to carry more than 150 passengers is required a Class A AIS. Currently only has a Class B AIS onboard. Prove proper installation of Class A AIS device.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2021
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 August 2020
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR." Emergency exits not labeled. Prove proper labeling of emergency exits.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2020
Resolved 14 August 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 August 2020
Resolved
Covered metal trash containers shall be provided in lounge areas. Vessel shall prove proper installation of metal trash cans.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2020
Resolved 14 August 2020
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 February 2019
Resolved
Each vessel must be provided with a visual and audible alarm to indicate high water in unmanned spaces. The audible alarm only works for 1 of 5 spaces. The audible and visual alarm for the lazarette is not operational. Make repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2019
Resolution: All alarms were tested sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2019
Resolved
Each crew member must be enrolled in a random drug testing program and pre-employment tested. One crewmember on the day of inspection has not been pre-employment tested and is not added to the company list. Crew member is not permitted to work on vessel until achieving these items.
Action required: 705 - Other - as specified
Resolved 26 March 2019
Resolution: All current crew members are enrolled in a random drug testing program.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 19 February 2019
Resolved
Lifejacket placards for donning instructions shall be posted in a conspicuous place accessible to passengers. No placards are posted. Post one port and stbd in main cabin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2019
Resolution: Placards were posted both port and starboard at main entry doors.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 February 2019
Resolved
Master and crew shall perform man overboard and fire drills. Drills not performed due to high winds.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 September 2021
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 February 2019
Resolved
Vessel is required class A AIS. Install approved class A AIS or request exception per deviations from rules (33CFR164.55). VSL currently operates in a confined geographic area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 September 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 February 2019
Resolved
Float switch wire has unapproved splice. Make appropriate repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 March 2019
Resolution: Splice has been properly installed.
Lifesaving › Lifebuoys › Serviceable
Issued 28 June 2017
Resolved
Replace the ringbuoy on the 02 deck bow.
Due 28 July 2017
Resolved 25 July 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 June 2017
Resolved
Provide reflective tape on 2 ringbuoys on main deck.
Due 28 July 2017
Resolved 25 July 2017
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 28 June 2017
Resolved
Troubleshoot and repair open grounds in three outlets on the 02 deck.
Due 28 July 2017
Resolved 25 July 2017
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 28 June 2017
Resolved
Provide outlet cover for broken cover on 02 deck.
Due 28 July 2017
Resolved 25 July 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 June 2017
Resolved
Remove hose between the bhd and valve on the waste line in the #2 void.
Due 28 July 2017
Resolved 25 July 2017
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 28 June 2017
Resolved
Troubleshoot and repair ground guage on switchboard.
Due 1 January 2018
Resolved 19 February 2019
Resolution: From discussions with O/O and manufacturer it is determined that the system is operating as designed.
Engineering › Bilge Water Management System › Piping
Issued 28 June 2017
Resolved
Properly repair the bilge pipe in the #2 void prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Resolution: Recieved photos and statement from Capt of vsl that attest to proper repairs and testing.
Stability › Watertight Integrity › General
Issued 28 June 2017
Resolved
Properly cap two open deck penetrations on the 02 weather deck.
Due 28 July 2017
Resolved 25 July 2017
Fire Fighting › Fire Pumps › Gland Sealing
Issued 28 June 2017
Resolved
Make repairs to fire pump seal.
Due 28 July 2017
Resolved 25 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2017
Resolved
Remove yellow drop wire from engine room panel.
Due 28 July 2017
Resolved 25 July 2017
Engineering › Steering Gear System › Hydraulic Hose
Issued 28 June 2017
Resolved
Renew both hydraulic hose on steering system in lazerette. Use SAE J1942 hose.
Due 28 July 2017
Resolved 25 July 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 28 June 2016
Resolved
Replace stbd exhaust flange in lazarette space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Resolution: Cleared due to duplicate entry; extended due date of primary entry to 31 DEC 2016.
Engineering › Pressure Vessel › Relief Valve
Issued 27 June 2016
Resolved
Prove proper operation of both pressure vessel relief valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Engineering › Pressure Vessel › Weld
Issued 27 June 2016
Resolved
Open pressure vessels (2) for internal exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Fire Fighting › Fire Pumps › Pressure
Issued 27 June 2016
Resolved
Prove proper operatin of fire pump (60psi).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 28 June 2016
Resolution: Verified operation of firepump.
Engineering › Bilge Water Management System › Not Operational
Issued 27 June 2016
Resolved
Prove proper operation of installed bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 28 June 2016
Resolution: Verified operation of bilge system.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 27 June 2016
Resolved
Prove proper operation of main engine shut downs from pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 June 2016
Resolved
Replace 03 ring buoys which have deteriorated grab lines.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 June 2016
Resolved
Ensure 2" emergency exit signs are posted throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 27 June 2016
Resolved
Replace 05 B-II fire extinguisher brackets with approved 809 or 895 brackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Stability › Watertight Integrity › General
Issued 27 June 2016
Resolved
Replace watertight cover on 02 deck port flood lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2016
Resolved
Remove or properly secure dead end wires on stbd main and port aft engine room by A/C.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 27 June 2016
Resolved
Secure door to constavolt in engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Lifesaving › Lifebuoys › Serviceable
Issued 27 June 2016
Resolved
Provide corrosion resistant clip for lifeline on bridge deck ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 June 2016
Resolved
Properly mount and wire power inverter for radar.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 June 2016
Resolved
Ensure all wire connection in bridge console have retaining type connectors.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Electrical › Electrical Distribution System (service) › Cable
Issued 27 June 2016
Resolved
Remove and do not use any portable cables, or electrical splitters on bridge, 01 deck, and dance floor.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 27 June 2016
Resolved
Ensure all crew are enrolled in company drug testing program.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 8 August 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 June 2016
Resolved
Crop and renew the deteriorated exhaust pipe flange on the stbd outboard exhaust pipe at the transom connection in the lazarette.
Due 31 December 2016
Resolved 11 April 2017
Resolution: Repairs made IAW the builders specs.