MAURY USCG vessel records Sign in
← All vessels

THERESA BALTIC

THERESA BALTIC is a 1986 tank ship. The Coast Guard has recorded 21 inspections since 1986, most recently in December 2009, along with 13 deficiencies — 4 with no resolution recorded — and 2 operational controls.

Records from 1986 to 2009. Most recent: operational control imposed, 9 December 2009.

Built
1986
Last inspected
9 December 2009
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8308123 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
268838
Flag
TUVALU
—
Maury page id
psix-268838

Inspections, by type

…with no type recorded11
…past their stated due date4
Years with a record 10 calendar years (1986–2009)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it41766 - Convention (Subpart B), Gross Ton
25855 - Convention (Subpart B), Net Ton
77769 - Dead Weight, Ton
92677 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

9 December 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3647632
9 December 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3648302
9 December 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3648550
4 December 2009 MARPOL Annex II Examination · COC-CHEM Renew · Ballast Water Examination · Deficiency Check · MARPOL Annex I Examination · ISPS I Exam · MARPOL Annex VI Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3640324
3 December 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3640325
13 July 2005 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2423843
27 September 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2204143
13 November 2003 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1947120
10 June 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 290941
10 June 2001 Tank Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1067723
27 April 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 277372
27 April 2000 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369664
28 February 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 275568
25 February 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 275054
24 May 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 428970
24 May 1999 Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1424760
9 April 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 414325
8 April 1998 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1122732
17 October 1994 Tank Vessel Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1356854
7 July 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 999648
6 July 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 309935

Deficiency record · 13

Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 9 December 2009 Resolved
The #2 Auxiliary Engine was leaking jacket water resulting in a high temp alarm, reducing the RPM.
Action required: 705 - Other - as specified
Due 9 December 2009
Resolved 10 December 2009
Resolution: Received, reviewed, and accepted class report satisfying the requirement.
Engineering › Diesel Engine (auxiliary) › Connecting Rod
Issued 4 December 2009 Resolved
1430 - Auxiliary Engine - The #3 cylinder on the #2 Auxiliary Engine is leaking jacket water. - SOLAS 74 I/11
Action required: 705 - Other - as specified
Due 18 December 2009
Resolved 10 December 2009
Resolution: Received, reviewed and accepted class report from DNV stating the deficiency has been rectified. The o-ring packing for the jacket water cooling connection was changed by the crew. The engine was inspected in running condition and no leakages were noted.
Engineering › Lubricating Oil Storage/Transfer System › Piping
Issued 4 December 2009 No resolution recorded
1150 - Loadings and unloading equipment - There are numerous hydraulic leaks for the actuators for the cargo valves. - SOLAS 74 I/11
Action required: 705 - Other - as specified
Due 18 December 2009 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Electric Bonding
Issued 4 December 2009 No resolution recorded
0999 - Other (general safety) - On deck there are numerous cargo pipes with missing or damaged bonding straps. - BCH Code III/3.7
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2009 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 4 December 2009 No resolution recorded
9800 - Other (clearly hazardous) - In the cargo area on deck, the vessel has filled the scuppers with concrete. This is not an acceptable means of plugging the scuppers. The vessel is authorized a one time waiver and must remove all concrete plugs and install mechanical means prior to next cargo operations in the U.S. after sailing foreign to the satisfaction of the Coast Guard. - 33 CFR 155.310
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2009 — due date passed with no resolution recorded
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 4 December 2009 No resolution recorded
1899 - Other (tanks) - The crew could not demonstrate proper operation of the Inert Gas System. The vessel is prohibited from conducting cargo operations in the U.S. that require the use of inert gas until proper operation and testing of the inert gas system is demonstrated to the satisfaction of the certificate issuing authority. - SOLAS 74/78 II-2/4.5.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 4 December 2009 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 13 July 2005 Resolved
Excessive amount of engine room light fixtures cracked. Replace/repair lenses to the satisfaction of Certificate Issuing Authority NLT 30 September 2005, SOLAS 74 II-1/45.1.3;
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 4 December 2009
Resolution: Cleared deficiency after successful examination.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 July 2005 Resolved
10cm by 30 cm rectangular cut-out in bulk head between purifier room and engine room with removable plate. Verify approval of through bulkhead fitting by Certificate Issuing Authority NLT 30 September 2005, SOLAS 74 II-2/42.4;
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 3 January 2010
Resolution: Cleared deficiency after successful examination.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 13 July 2005 Resolved
Standard Discharge Connection and Sewage Discharge Connection are labeled improper. Verify labeling is correct to the satisfaction of Certificate Issuing Authority NLT 30 September 2005, MARPOL 73/78 Annex I Reg 19.
Action required: 705 - Other - as specified
Due 30 September 2005
Resolved 4 December 2009
Resolution: Cleared deficiency after successful examination.
Navigation
Issued 28 February 2000 Resolved
PROVE OPERATION OF STEERAGE FROM PORT BRIDGEWING STEERAGE POSITION. SLOW/SLUGUISH RESPONSE POSSIBLY DUE FROM CORROSION AT/AROUND CONTROL LEVER ROTATION JOINT.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Accommodation/Occupational Safety
Issued 28 February 2000 Resolved
REMOVE OBSTRUCTION BLOCKING ACCESS TO EMERGENCY ESCAPE TRUNK IN ENGINEROOM.ENGINE PARTS PLACED IMMEDIATELY IN FRONT OF DOOR PREVENTING IT FROM OPENINGCOMPLETELY.
Condition: Unknown
Due 8 March 2000
Resolved 8 March 2000
Deck/Cargo
Issued 6 July 1986 Resolved
46 CFR 32.53 UNABLE TO TEST INERT GAS SYSTEM DUE TO FAULTY VALVE
Condition: Unknown
Due 6 July 1986
Resolved 6 July 1986
Navigation
Issued 6 July 1986 Resolved
33 CFR 164.33(A)(2)(I) NOS COAST PILOT VOL 7 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 6 July 1986
Resolved 6 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.