← All vessels
MEDI KOBE
MEDI KOBE is a 2001 freight ship. The Coast Guard has recorded 7 inspections since 2001, most recently in September 2011, along with 3 deficiencies and 1 operational control.
Records from 2001 to 2011. Most recent: operational control imposed, 9 September 2011.
- Built
- 2001
- Last inspected
- 9 September 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9215737 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DYFP
26884
Flag
PHILIPPINES
—
Maury page id
psix-26884
Inspections, by type
…with no type recorded2
Years with a record
6 calendar years (2001–2011)
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it75924 - Dead Weight, Ton
85937 - Displacement, Ton
39126 - Convention (Subpart B), Gross Ton
25373 - Convention (Subpart B), Net Ton
85937 - Displacement, Ton
39126 - Convention (Subpart B), Gross Ton
25373 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
9 September 2011
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4135111
3 September 2010
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3834103
19 February 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3149680
19 November 2007
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3100793
11 November 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3096872
24 January 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2569930
26 November 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 295841
Deficiency record · 3
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 September 2011
Resolved
0715 - Detection - Fire detection systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO discovered a plastic bag covering the smoke detector above the main air compressors. Upon expansion, engineering crew stated they were unaware it was covered. - SOLAS 74a, II-2/14.2.1.1
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 9 September 2011
Resolved
1499 - Other (Prop. & Aux. Machinery) - Each emergency generating set must have a second source of energy for additional 3 starts within 30 minutes. Vsl can start EDG with battery set #2, but not battery set #1. Vsl requested new batteries on 7 Aug. 11 but operator has not yet provided. - SOLAS 74a, II-1/44
Operations/Management › Ballast Water Managment › Submission of Report
Issued 24 January 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.