Records from 2016 to 2020. Most recent: inspection, 4 September 2020.
Documentation record
Registered dimensions (L × B × D)95.4 ft × 21.0 ft × 7.3 ft
Registered tonnagegross 92 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS OF STUART INC · STUART, FL, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationNo Operation - PM · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 10
4 September 2020
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7049825
14 June 2019
Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6734949
17 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6662448
6 August 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6488951
18 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6485295
22 January 2018
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6341213
24 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6131586
2 June 2016
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5895379
7 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5792762
6 January 2016
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5792140
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 September 2020
No resolution recorded
Failure to complete inspections IAW 46 CFR 176.500 and §176.600
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2020 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 17 April 2019
Resolved
Replace/repair public address system.
46CFR184.610
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2019
Resolved 14 June 2019
Resolution: Received video recording of PA system working
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 April 2019
Resolved
Provide charts and navigation publications for intended voyage. 46CFR184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 14 June 2019
Resolution: Vessel aquired proper charts and pubs for intended voyage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2019
Resolved
Remove or properly connect wiring for winch in the bow void space. 46CFR183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 14 June 2019
Resolution: Received photos of winch wiring properly connected.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 April 2019
Resolved
Provide emergency instructions at the operating station.
46CFR185.510
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 14 June 2019
Resolution: Received photo of emergency instructions at the operating station.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 17 April 2019
Resolved
Provide garbage placards as required by 33CFR151.59
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 14 June 2019
Resolution: Received photo of garabage placard onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2018
Resolved
Replace as original exhaust loop on center main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2018
Resolved 7 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 August 2018
Resolved
Repair air leak on pneumatic controller in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 August 2018
Resolved 8 August 2018
Resolution: O/O had pneumatic rebuilt
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 August 2018
Resolved
Remove rags from galley exhaust and replace with noncombustable material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 7 November 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2018
Resolved
Remove electrical wiring not in service from electrical cabinet on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2018
Resolved 7 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 August 2018
Resolved
Inspect port main engine for exhaust leak on inboard exhaust.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2018
Resolved 7 November 2018
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2018
Resolved
Remove starter wiring from STBD diesel generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 7 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 August 2018
No resolution recorded
Provide manufacture specs for each Buoyant Apparatus/Life Float with date of manufacture and person capacity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 December 2018 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2018
Resolved
Ensure life jackets are stowed in convenient locations on main and upper deck levels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2018
Resolved 7 November 2018
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 July 2018
Resolved
Conduct permanent repairs to fore deck
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 October 2018
Resolved 10 July 2019
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2016
Resolved
Provide copy of valid FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 8 July 2016
Resolution: recd
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 9 June 2016
Resolved
Provide copy of valid FCC Bridge to Bridge Certificate.
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 8 July 2016
Resolution: recd
Communications › Radio Communications › VHF Radiotelephone
Issued 9 June 2016
Resolved
Provide proper VHF/DSC Radio and program MMSI# per MSIB.
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 8 July 2016
Resolution: completed