MAURY USCG vessel records Sign in
← All vessels

ATLANTIC MONTERREY

ATLANTIC MONTERREY is a 1986 freight ship. The Coast Guard has recorded 25 inspections since 1986, most recently in February 2012, along with 17 deficiencies and 5 operational controls.

Records from 1986 to 2012. Most recent: operational control imposed, 16 February 2012.

Built
1986
Last inspected
16 February 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8408715 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
269682
Flag
SINGAPORE
—
Maury page id
psix-269682

Inspections, by type

…with no type recorded14
Years with a record 13 calendar years (1986–2012)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it25956 - Convention (Subpart B), Gross Ton
14547 - Convention (Subpart B), Net Ton
53196 - Displacement, Ton
45263 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

16 February 2012 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4239265
20 August 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4121507
3 August 2011 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 4104241
2 February 2010 MARPOL Annex VI Survey · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3668942
12 January 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3662942
12 January 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3664190
14 April 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3450541
11 April 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3450526
11 February 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3415952
14 January 2009 ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3393396
20 August 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2753495
19 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2752859
19 August 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2896749
25 May 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2658526
28 April 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2660017
26 May 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2368586
2 February 2004 Type not recorded
No type recorded · USCGC WASHINGTON (WPB 1331) · USCG Oceania District (CGD-O) · Activity 2016842
11 October 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1923460
11 October 2003 Type not recorded
No type recorded · USCGC ASSATEAGUE (WPB 1337) · USCG Oceania District (CGD-O) · Activity 1934079
26 February 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 375422
3 October 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 339648
27 September 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 332753
23 June 1988 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 324239
23 August 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 310981
18 June 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 309393

Deficiency record · 17

Engineering › Fuel Oil Service System › Valve, Control
Issued 16 February 2012 Resolved
1710-Oil Record Book- PSCO observed the quick closing fuel shutoff valve on the diesel oil service tank for the generator blocked in the open position with a bolt. CITE: 74SOLAS (1981 Amend) II-2/14.
Due 16 February 2012
Resolved 16 February 2012
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating that the deficiency was rectified. The bolt blocking the Quick Closing Valve operation was removed. The valve was operationally tested and found to be satisfactory.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 16 February 2012 Resolved
0830-Pipes wires (insulate)- accident prev. PSCO discovered electrical lines intended to attach to radio batteries in battery space below navigation bridge which were not attached to batteries. The intended lines lead to radio panel that has not been in operation since 2003 and was properly tagged out.
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 16 February 2012
Resolution: Received, reviewed and accepted class report from American Bureau of Shipping stating the deficiency was rectified. Crew removed all old unused grounding wires for the battery package.
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 14 January 2010 Resolved
Vessel experienced a power irregularity when engine order "full ahead" was given.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2010
Resolved 14 January 2010
Resolution: Received, reviewed and accepted class report from ABS stating that the problem was most likely due to recent cold temperatures and the six days in the outer anchorage. A second Pilot came on board and noticed no irregularities while maneuvering.
Navigation › Collision/Grounding Avoidance › Radar
Issued 11 April 2009 Resolved
The vessel was granted a deviation to enter The Port of New Orleans with an inoperable radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2009
Resolved 13 April 2009
Resolution: Recieved technicians report attesting to the proper operation of the radar unit. See narrative of act #3450541 for further information.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 14 January 2009 Resolved
Observed #4 main engine lube oil supply line to exhaust valve was loose and leaking. 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2009
Resolution: Received confirmation and pictures from surveyor attesting to the satisfactory repair of the lube oil supply line. The line was fitted with a new conical washer.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 14 January 2009 Resolved
During accommodation and engineering space examination, observed several portable fire extinguishers did not have proper securing brackets. Ensure portable fire extinguishers are installed with securing brackets appropriate for all the extinguishers onboard. 70a
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2009
Resolution: Received confirmation and pictures from surveyor attesting to the satisfactory repair of portable fire extinguisher securing brackets. Securing straps were replaced.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 25 May 2006 Resolved
Improper maintenance/house keeping in meat/fish reefer stores. There is an excessive build-up of ice on the floors/piping. The ice on the floors must be removed to ensure the safety of all members of the crew entering these spaces. ILO 147
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 27 May 2006
Resolution: Class report: Ice has been removed, additional non-skid provided, and emergency escape devices are functioning as intended.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 May 2006 Resolved
Several A class doors in the main deck house passage will not close with out adjustment/excessive force and seals are warped/deteriorated. The air con door is bulging near the locking mechanism/handle and the lower right hinge is off-set. SOLAS 74 II-2 regs 3 & 51
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 27 May 2006
Resolution: Received class report stating doors had been serviced to ensure fire protection.
Lifesaving › Lifeboat › Hull
Issued 26 May 2005 Resolved
The port and starboard foam chambers have been compromised. Water has leaked into the chambers and into the food storage areas.
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 30 May 2005
Resolution: The Classification Society inspected this and repairs were made under his direction.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 26 May 2005 Resolved
Forty-four (44) lifeboat rations had to be replaced. The vacuum seal was broken and mold was growing on the outside of the packages. Believed most of this was caused from the water leaking into the flotation chambers and into the food storage space.
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 27 May 2005
Resolution: New food packages were purchased and placed on the vessel.
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 May 2005 Resolved
The ballast line in the engine room had been recently repaired by the crew. Due to the poor welding job by the crew the Classification Society was called in to check the repair.
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 30 May 2005
Resolution: The Classification representative had the crew remove the pipe and replace it along with the flange. It was successfully pressured tested 1.5 times under his supervision.
Engineering › Sea-water System (primary cooling) › Valve
Issued 26 May 2005 Resolved
The crew recently patched the main engine three (3) way cooling valve using liquid steel. The Classification Society was called in to inspect this. A condition of class was issued and the valve must be replaced by November 2005.
Action required: 705 - Other - as specified
Due 30 May 2005
Resolved 30 May 2005
Resolution: The Class inspected this and found a hole in the valve. He directed the crew to place a bolt and nut in the hole and cover the outside with plastic steel. It was tested to two (2) times the maximum pressure under his direction.
Construction/Loadline › Markings › Load Line Mark
Issued 11 October 2003 Resolved
Paint loadline marks in contrasting color to hull in accordance with ICLL Regulation 8 to the satisfaction of class prior to next U.S. port after sailing foreign.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 October 2003
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 October 2003 Resolved
Provide proof that Administration (Singapore) has accepted qualifications of the 5 deck watchstanders as per Safe Manning Certificate IAW STCW Article VI, Certificates and STCW Regulation I/14, Responsibilities of Companies.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2003
Accommodation/Occupational Safety › Washroom/Toilet
Issued 7 October 2003 Resolved
Prove proper operation of hot water in galley, hospital and crew bathrooms IAW ILO 147 prior to departure from port. LEGACY COMPONENT DESC: Hot and Cold Running Water
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 October 2003 Resolved
Provide U.S. Coast Pilot [name withheld] List, Tide Tables and COLREGS IAW 33 CFR Part 164.33
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2003
Documentation
Issued 18 June 1986 Resolved
OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL OF THE INFORMATION REQUIRED BY 33CFR155.750.
Condition: Unknown
Due 24 August 1986
Resolved 18 June 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.