Records from 2002 to 2026. Most recent: inspection, 20 April 2026.
Inspection history · 30
20 April 2026
Examination of Repairs · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8312914
10 March 2026
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8312927
2 April 2025
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8104387
18 April 2024
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7897350
8 April 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7891906
2 April 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7889788
14 December 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7840561
29 October 2023
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7820765
22 August 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7774279
11 April 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7670785
6 November 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7590331
18 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7432914
28 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7419626
28 March 2022
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7424738
11 September 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7311476
2 April 2021
Deficiency Check · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7167468
9 March 2021
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7150191
19 November 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7098719
13 April 2020
Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6938864
13 October 2019
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6831675
3 April 2019
DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6654872
23 April 2018
Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6395729
9 April 2018
Hull Examination · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6388301
26 July 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6221422
23 July 2017
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6222286
23 May 2017
Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6159798
20 May 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6154141
21 March 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6106542
4 April 2016
Hull Examination · Examination of Repairs · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5846913
1 March 2016
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5824510
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 11 March 2026
Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Both life floats had cracking exposing the foam interior. Repair life floats to the satisfaction of the attending MI prior to credit drydock.
46 CFR 180.202 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: Repaired both life floats to satisfaction of MI
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2026
Resolved
A vessel on an oceans route must carry six hand red flare distress signals and six hand orange smoke distress signals. Vessel had on board 6 hand red flare distress signals. Acquire 6 additional distress signals prior to nighttime operations.
46 CFR 180.68 (a)(1)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: Vessel acquired 6 additional distress signals
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2026
Resolved
Accessories, such as switches, fuses, and sockets, shall be standard National Electric Code types for the loads to be carried and shall be of types listed by, or types equal to those listed by UL. Vessel had broken electrical outlet on the port side bridge console. Replace outlet to the satisfaction of the MI.
46 CFR 183.05-35 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 April 2026
Resolution: MI confirmed replacement of electrical outlet
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 11 March 2026
Resolved
All crew and passenger spaces shall be adequately ventilated in a manner suitable to the purpose of the space. Ductwork was corroding and holes were present in ventilation for berthing at the forepeak. Repair to the satisfaction of the MI prior to credit drydock.
46 CFR 177.20-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: MI confirmed installation of new ductwork
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 March 2026
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. The system was not interconnected when MI first came on board. Vessel corrected issue on the spot.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 11 March 2026
Resolution: Corrected on spot by connecting fire detection system
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 March 2026
Resolved
A Certificate of Inspection is valid for 5 years for all other vessels. Vessel passed expiration date for COI. Complete COI renewal prior to passengers.
46 CFR 176.107 (b)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 March 2026
Resolution: Completed COI Renewal
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 April 2025
Resolved
Each vessel certificated to operate on an oceans route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 100% of the total number of persons permitted on board. Both life floats were determined to be unservicable by the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: Life floats repaired in accordance with the manuafacturers procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 09 PFD's on board were found unservicable due to deterioration of the retro-reflective material. Passenger count reduced by 08 until PFD's are repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: PFD retro reflective material was repaired on 09 PFD's.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 April 2025
Resolved
Vessels must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accomodation spaces and machinery spaces. The system was not interconnected when tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2025
Resolution: Witnessed satisfactory test of interconnected system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2025
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with vessel's name. Ring life buoy was not clearly marked with vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2025
Resolution: Vessel's name and home port stenciled in on ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 April 2024
Resolved
Propulsion machinery installed on each vessel is suitable for the vessel and its operation and that the auxiliary machinery is suitable for the purpose intended. It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. During operational tests of the main engines, the port engine was unable to be secured from the primary shutdown station located on the bridge. Repair/replace parts needed to demonstrate proper operational shutdown of port engine from primary station to the satisfaction of the attending MI.
46 CFR 182.01-5
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2024
Resolved 19 April 2024
Resolution: attended vessel and witness shut down of port MDE from bridge.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 April 2024
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel did not complete credit drydock inspection which was due by 31 MAR 2024. Vessel will need to complete drydock inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2024
Resolution: Conducted credit dry dock on 08APR2024. Cleared deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 11 April 2023
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Found structure beam above starboard main diesel engine damaged. Provide repair proposal.
46 CFR 177.01-5
Old "T"
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2023
Resolution: The beam has been reinforced with the 1/4” thick plate screwed through and the hanger was applied on top for added reinforcement. See photos.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2023
Resolved
Except as otherwise provided in this section main propulsion machinery installations shall comply with the provisions of this part. Found oil drain hose on starboard engine damaged and wrapped in duct tape. Replace damaged hose.
46 CFR 182.05-5
Old "T"
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2023
Resolved 3 May 2023
Resolution: O/O provided photo proof of newly installed hose.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 April 2023
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers. Rewrite vessel name in legible letters on Starboard side ring buoy. 46 CFR 185.604 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 3 May 2023
Resolution: O/O provided photo proof of new, legible stenciling on ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 April 2023
Resolved
Each life jacket carried on a vessel on oceans...must have a life jacket light. Found 01 child life jacket light screw top missing. Replace life jacket light. 46 CFR 180.75 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 3 May 2023
Resolution: O/O provided photo proof of properly functioning life jacket light.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 April 2022
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each unmanned space. The forepeak bilge high level alarm audible and visual indicators on the bridge were not working properly. Make effective repairs to the satisfaction of the attending marine inspector. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 4 May 2022
Resolution: Received proof of high water alarm functioning.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 18 April 2022
Resolved
At each vessel inspection, all observed hazardous situations must be corrected. The forepeak access ladder bottom rung broke during inspection due to rooted wood. Make effective repairs to the satisfaction of the attending marine inspector. 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 26 April 2022
Resolution: Received pictures of the ladder rung fixed, sat
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 April 2022
Resolved
All electrical installations shall be to the satisfaction of the officer in charge, marine inspector. Receptacle outlet in the main cabin was missing the protective cover. Replace cover to the satisfaction of the attending marine inspector. 33 CFR 183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 26 April 2022
Resolution: Received pictures of the covered installed on receptacle outlet, sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 April 2022
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and inland navigation rules. The masthead light lens cover is deteriorated. Replace to the satisfaction of the attending marine inspector. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 4 May 2022
Resolution: Recieved proof of masthead light being replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2022
Resolved
Vessel missed required due date for plan submittal of monitoring device required by 3/28/2022. Granted 30 day extension for plan submittal. Failure to meet deadline will result in another 835 issued for no passenger overnight accommodations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 April 2022
Resolved 18 April 2023
Resolution: Verified plans were submitted during inspection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 March 2022
Resolved
Vessel was issued 30 day extension to meet required plan submittal for watch monitoring device(s) per new Fire Safety of Small Passenger Vessels Federal Register/Vol 86, No. 245, dated December 27, 2021. Vessel failed to submit required plans, therefore vessel is not authorized to use overnight accommodations for passengers until plans are received and approved by local OCMI. 46 CFR 185.410(b)
Action required: 705 - Other - as specified
Due 4 May 2022
Resolved 18 April 2023
Resolution: Verified plans were submitted during this inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 March 2021
Resolved
Lazarette electric submersible pump was not secured to the deck. Secure with screw or mounting bracket. Due March 23, 2021. 46 CFR 182.520(e)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 6 April 2021
Resolution: Attending inspectors confirmed it has been secured
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 March 2021
Resolved
The 12 passenger life float has grab lines that are wasted and have separated from the float’s body. Repair and replace. Due March 23, 2021. 46 CFR 176.808(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 6 April 2021
Resolution: Confirmed lines and line retention loops have been replaced
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 March 2021
Resolved
Life float paddles were not lashed to their respective floats. Lash 2x paddles in each float. Due March 23, 2021. 46 CFR 180.175(f)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 6 April 2021
Resolution: Witness LF paddles have been lashed down.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 March 2021
Resolved
Life floats have several worn spots that need to be repaired. Repair with manufacturer approved repair kit.Due April 9, 2021. 46 CFR. 176.808(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: [name withheld] approved repair kit was used to repair worn spots.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2021
Resolved
Remove all dead end or unused wires from the boat. Dead end wires were found in the engine room and in the forepeak. Due April 9, 2021. 46 CFR 183.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: O/O consulted electrician to remove dead end and unused wires.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2021
Resolved
Remove/ replace wiring splices between 3 or more wires in the engine room. Several were found in the vicinity of the battery box. Due April 9, 2021 46 CFR 183.340
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: O/O consulted electrician to remove splices, confirmed on board.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2021
Resolved
Electric powered reels were installed on vessel without USCG plan review. No over current protection was installed on conductors. Email the following to [email withheld]: Simple wiring diagram, Wire gauge, Wire length, Amperage of installed reels, Amperage of breaker/fuse for approval. Due April 9, 2021 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2021
Resolved 6 April 2021
Resolution: Received simple wiring diagram. Uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 March 2021
Resolved
Port engine did not shutdown during Fireboy test and required adjustment by owner. CORRECTED ON THE SPOT. 46 CFR 181.420(a)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 March 2021
Resolution: Owner adjusted linkage between solenoid and fuel rack on engine. Retest was successful.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 March 2021
Resolved
Extension cord was found draped over Engine Room Fire Extinguisher. Permanently mount extra 10 B:C fire extinguisher next to starboard generator. CORRECTED ON THE SPOT. 46 CFR 176.810
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 9 March 2021
Resolution: Corrected on the spot.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 13 April 2020
Resolved
Type III Marine Sanitation Devices (MSD) must be used solely for the storage of sewage and flushwater. The forepeak individual bilge pump discharges into the Type III MSD. Redirect the bilge discharge through a through-hull located as high above the water as possible and install a positive action shutoff valve at the hull penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 April 2020
Resolved 22 April 2020
Resolution: Received photo evidence that owner routed the forepeak bilge overboard discharge to a through-hull valve w/ shutoff located as high above the water as possible.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 13 October 2019
Resolved
Install emergency lighting in passenger overnight accomodation space. Until installation is complete the installed DC lighting must be kept energized when passengers are aboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 13 November 2019
Resolution: Installed
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 13 October 2019
Resolved
Install additional foot rung, hand rung, and door latch on the forward emergency escape in the passenger overnight accomodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 13 November 2019
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 13 October 2019
Resolved
Repair electrical ground in the galley outlet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2019
Resolved 13 November 2019
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 April 2019
Resolved
All bilge level audible alarms at operating station did not work.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 3 April 2019
Resolved 3 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2019
Resolved
03 floating waterlight batteries were expired and of the wrong type.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 3 April 2019
Resolved 3 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2019
Resolved
Vessel large lifefloat had deteriorated and needed repairs identified by inspector. Small lifefloat grablines were worn and no longer attached to lifefloat
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2019
Resolved 9 April 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 April 2019
Resolved
04 paddles required for the lifefloat were deteriorated and in need replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 April 2019
Resolved 9 April 2019
Lifesaving › Lifefloat › Painter
Issued 23 April 2018
Resolved
Painter for life floats is dry rotted; renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Lifesaving › Lifefloat › Paddle
Issued 23 April 2018
Resolved
22 person life float is missing one paddle; replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Lifesaving › Lifefloat › Serviceable
Issued 23 April 2018
Resolved
10 person life float has evidence of cracking and sun damage; repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 23 April 2018
Resolved
Lifesaving inspection log is missing. Inspect lifesaving equipment, log and provide to CG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 April 2018
Resolved
Exhaust piping prior to water cooled area is missing lagging. Lag exhaust piping.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 23 April 2018
Resolved
Cracks present in exhaust piping on port side engine exhaust. Repair/replace components.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Lifesaving › Lifebuoys › Serviceable
Issued 23 April 2018
Resolved
Grabline on lifering dry rotted. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2018
Resolved 7 May 2018
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 26 July 2017
Resolved
Submit dive operations information and plan to OCMI including weight of dive gear carried on board vessel and number of persons carried. Vessel is restricted from operating as a dive vessel until information has been reviewed and any stability concerns have been addressed to the satisfaction of the attending CGMI.
Action required: 705 - Other - as specified
Resolved 28 July 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2017
Resolved
Vessel had a marine incident w/ loss of propulsion causing him to crash into the docks. Vessels port middle two wire rail courses are damaged and must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2017
Resolved 24 May 2017
Resolution: Replaced wire with new.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2017
Resolved
Vessels port upper bulwark cap is FRP damaged, must grind and remove all glass for further insp, then with approval from CGMI repair in kind
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 30 May 2017
Construction/Loadline › Hull › Hull Plating
Issued 23 May 2017
Resolved
Vessels pulpit area has many surface cracks at the top and where the pulpit meets the hull including around the stbd stanchion, must grind all loose glass to good glass for further inspection from a CGMI then with permission repair in kind to like new condition.
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 30 May 2017
Deck/Cargo › Mooring/Anchoring › Anchoring Arrangement
Issued 23 May 2017
Resolved
Owner/Operator must write in an email his intentions of where, how, species, and distance from land where he will operate with passengers until repairs are made.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2017
Resolution: Email with required information recieved
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 21 March 2017
Resolved
JB01: Vessel's bilge high level alarm in the forward compartment (forward of collision bulkhead) is inoperable. Provide working bilge high level alarm in space. 46 CFR 182.530(a). Due 04APR17
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 March 2017
Resolution: Bilge high level alarm switch was replaced and is operable
Stability › Watertight Integrity › General
Issued 21 March 2017
Resolved
JB02: Water is leaking into lazarette from port engine exhaust tube at flexible hose connection. Make port engine exhaust tube watertight. 46 CFR 176.800. Due 04APR17.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 27 March 2017
Resolution: Port Exhaust had no visible leaks in lazarrette.
Accommodation/Occupational Safety › Potable Water System › General
Issued 5 April 2016
Resolved
Plug hole in forepeak tank
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 25 April 2016
Resolution: Hole pluged in water tank
Construction/Loadline › Hull › Side Shell
Issued 5 April 2016
Resolved
Repair tabbing in bunkroom closet, starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2016
Resolved 25 April 2016
Resolution: Repair was sat.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 1 March 2016
Resolved
Vessel needs to provide current enrollment lilst for consortium. Additionally 24 testing facility must be identified. 46CR16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 14 March 2016
Resolution: Vessel provided appropriate information