Records from 1986 to 2026. Most recent: inspection, 4 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 77
4 March 2026
Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8320065
3 September 2025
Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226188
26 March 2025
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 8100868
20 February 2025
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082065
3 February 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8072774
19 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7881533
4 March 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7875062
16 January 2024
Special · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7849887
15 November 2023
Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7825753
1 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7643970
14 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7636810
15 August 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7534123
2 March 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7404937
26 July 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7269746
3 March 2021
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7149413
25 February 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7145584
2 March 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6918802
23 September 2019
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822993
4 June 2019
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6704132
26 February 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6634155
5 February 2019
Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6621632
27 February 2018
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6360306
2 March 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6093677
23 February 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6088432
28 April 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5860519
28 October 2014
DAPI Audit · Plan Review "T" Boat · Hull Examination · Internal Structural Exam · COI Inspection · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4995114
1 May 2012
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4298537
9 February 2011
Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3944786
24 February 2009
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3420734
10 June 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3229073
7 June 2007
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2992634
27 February 2007
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2878382
10 August 2006
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 2743245
21 March 2006
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2606410
4 May 2005
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2348944
17 February 2005
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2289273
10 May 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2138214
19 April 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2047848
23 April 2003
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1779623
27 March 2003
Periodic Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1770574
11 February 2003
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1742330
15 May 2002
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1616964
23 April 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1458870
13 February 2001
Deficiency Check · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1362119
25 May 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1053403
15 February 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1464928
18 May 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1372679
8 March 1999
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347984
23 June 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 793073
7 May 1998
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1453481
19 February 1998
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1381138
27 May 1997
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1431890
28 May 1996
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1439742
7 March 1996
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367692
16 May 1995
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455263
29 March 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1171488
1 March 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1174172
28 April 1993
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 836899
20 April 1993
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 840194
3 June 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1263199
6 May 1992
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 955023
8 April 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1259844
8 April 1992
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1264404
10 March 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960889
1 May 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 907666
13 February 1991
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 907066
16 May 1990
Drydock Extension · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 929194
10 May 1989
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1032570
5 April 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1340972
8 February 1989
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1345281
4 May 1988
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1348585
16 March 1988
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1296423
18 November 1987
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334761
16 November 1987
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1024034
9 June 1987
Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1338485
21 October 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1317892
19 May 1986
Initial Construction-Excluding Oversight · Initial Certification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 992043
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 March 2024
Resolved
Ensure remote fuel shutoff valves fully close. Ensure remote fuel shutoff valves are labeled with service.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2024
Resolved 19 March 2024
Resolution: Corrected.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 2 March 2020
Resolved
NAVIGATION CHARTS WERE NOT CURRENT/UPDATED. VESSEL MUST CARRY ADEQUATE AND UP TO DATE CHARTS OF APPROPRIATE SCALE TO MAKE SAFE NAVIGATION POSSBILE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 March 2020
Resolved 9 March 2020
Resolution: Received documentation of updated charts.
Engineering › Bilge Water Management System › Hose
Issued 7 April 2015
Resolved
Provide Portable bildge pump hose extension.
Due 7 May 2015
Resolved 30 April 2015
Resolution: Witnessed.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 April 2015
Resolved
Provide Alcohol test strips.
Due 7 May 2015
Resolved 30 April 2015
Resolution: Witnessed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 7 April 2015
Resolved
Conduct DAPI Audit
Due 7 May 2015
Resolved 30 April 2015
Resolution: Conducted
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 April 2015
Resolved
Provide FCC Radio Telephony certificate.
Due 7 May 2015
Resolved 30 April 2015
Resolution: Witnessed.
Fire Fighting › Means of Escape › Blocked
Issued 1 May 2012
Resolved
Escape Hatch is not operable from both sides.
Condition: Placed in Improper Service
Due 15 May 2012
Resolved 10 May 2012
Resolution: Handles installed on both sides.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 May 2012
Resolved
Missing machinery guards on pulley, gears, & belts system.
Condition: Placed in Improper Service
Due 15 May 2012
Resolved 10 May 2012
Resolution: Guards installed
Engineering › Bilge Water Management System › Valve
Issued 14 February 2011
Resolved
Forward bilge system valveand reach rod were frozen in the closed postion.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2011
Resolved 28 March 2011
Resolution: New valve reach rod installed
Construction/Loadline › Penetrations › Valve Flange
Issued 14 February 2011
Resolved
Through hull fitting for live bait well was improperly installed. The valve was not bolted to the hull.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2011
Resolution: Marine grade piping installed, Valve tapped into hull.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 February 2011
Resolved
The center long does not have a drain or freeing port to allow water to drain properly to center of bilge.
Condition: Improper/Lack of Maintenance
Due 28 March 2011
Resolved 28 February 2011
Resolution: Limber holes drilled.
Fire Fighting › Means of Escape › Doorways
Issued 14 February 2011
Resolved
Escape hatch can not be opened from topside.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2011
Resolution: Handles installed on top deck.
Lifesaving › Lifefloat › Netting
Issued 14 February 2011
Resolved
Mesh netting parted when pulled on.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2011
Electrical › Lighting (service) › Lighting Fixture
Issued 14 February 2011
Resolved
Overhead lighting in berthing area, missing diffusers/covers
Action required: 705 - Other - as specified
Due 8 March 2011
Resolved 8 March 2011
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 14 February 2011
Resolved
Grounding strap improperly installed and/or missing in lazarette.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2011
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2011
Resolved
Vessel had plastic wire tie wraps in lieu of metal supports every 24 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 8 March 2011
Construction/Loadline › Penetrations › Valve Flange
Issued 24 February 2009
Resolved
Replace 1" ball valve supplying bait well.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2009
Construction/Loadline › Penetrations › Valve Flange
Issued 24 February 2009
Resolved
Replace air intake for port main diesel engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2009
Construction/Loadline › Hull › Hull Plating
Issued 24 February 2009
Resolved
Fare and repair FRP as marked in isolated areas on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2009
Engineering › Fuel Oil Service System › Valve
Issued 24 February 2009
Resolved
Replace port side fuel supply and cutoff valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 March 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 June 2008
Resolved
Demonstrate audible and visual indication for "Bilge High Water Alarm".
Due 10 July 2008
Resolved 16 September 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 June 2008
Resolved
Clean up oil on wires and deck below bridge house wheel. Remove unused wires and cables below wheelhouse.
Due 10 July 2008
Resolved 16 September 2008
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 June 2008
Resolved
Conduct and log drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2008
Electrical › Electric Supply System (service) › Battery Conductor
Issued 10 June 2008
Resolved
Remove excessive conductors from batteries; wire to panel IAW subchapter T. Excessive conductors were removed, vsl owner plans to replace wiring in kind after season. Plans may need to be submitted pending any alterations to current system.
Action required: 705 - Other - as specified
Due 7 December 2008
Resolved 3 March 2009
Construction/Loadline › Hull › Hull Plating
Issued 27 February 2007
Resolved
Found several localized minor "blisters" on hull below waterline. Repair all areas marked to as built specifications. Workmanship subject to the approval of the attending marine inspector. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 27 March 2007
Resolved 1 March 2007
Construction/Loadline › Penetrations › Valve Flange
Issued 27 February 2007
Resolved
Found hull penetration through hull fitting shut off valves for propulsion engine cooling system frozen. Open, clean, inspect and lubricate all valves and demonstrate proper operation. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 1 March 2007
Stability › Watertight Integrity › General
Issued 27 February 2007
Resolved
Make aft lazarette access hatch watertight and secure with suitable captive device as required by 46 CFR 179.360
Due 28 March 2007
Resolved 1 March 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2006
Resolved
Remove unused wiring and hoses from engine room as required by 46 CFR 183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 27 March 2006
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 March 2006
Resolved
Perform maintenance on frozen raw water valves as required by 46 CFR 182.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 27 March 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 21 March 2006
Resolved
Demonstrate proper operation of high water alarms as required by 46 CFR 182.530.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 27 March 2006
Lifesaving › Lifefloat › Serviceable
Issued 21 March 2006
Resolved
Make proper repairs to outer cover of life float as required by 46 CFR 180.200.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 27 March 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 March 2006
Resolved
Provide proof of compliance with 46 CFR 16 for deckhand.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 27 March 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 4 May 2005
Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 4 June 2005
Resolved 21 March 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 4 May 2005
Resolved
Post emergency instructions (46 CFR 185.510)
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 6 May 2005
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 4 May 2005
Resolved
Tighten fasteners on hand rails, starboard side, main deck, forward. (46 CFR 176.800)
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 6 May 2005
Lifesaving › Lifefloat › Lifeline
Issued 4 May 2005
Resolved
Replace life lines and pendants on installed life float IAW 46 CFR 180.160.010.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2005
Resolved 6 May 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 4 May 2005
Resolved
Provide serviceable electric floating light approved in accordance with 46 CFR 161.010 for life float in accordance with 46 CFR 180.175(e).
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2005
Resolved 6 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2005
Resolved
Provide first aid kit approved in accordance with 46 CFR 160.041 (or kit with equivalent contents) as required by 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 6 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 4 May 2005
Resolved
Install suitable hose clamps on all fuel oil service system flex hose assemblies that are fitted with press on connectors. (46 CFR 182.720).
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 6 May 2005
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 4 May 2005
Resolved
Make machinery space overhead, fore and aft bulkheads where penetrations for wire, cables, and ventilation pipe pass vapor tight to minimize fire hazards. (46 CFR 177.405).
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 6 May 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 May 2005
Resolved
Install emergency lighting in all passenger accommodation space located below the main deck in accordance with 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 6 June 2005
Resolved 21 March 2006
Construction/Loadline › Hull › Hull Plating
Issued 17 February 2005
Resolved
Repair eight delaminated areas on starboard side shell in accordance guidance set forth in NVIC 8-87.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 1 March 2005
Resolution: All delaminated areas were ground out, allowed to dry and renewed as per NVIC 8-87.
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 February 2005
Resolved
Renew or repair raw water intake valves for both port and starboard engines as per 46 CFR 179.350(c).
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 1 March 2005
Resolution: Both valves were replaced in kind and found satisfactory.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 February 2005
Resolved
Renew or replace intermediate cutlass bearing on port propeller shaft as per 46 CFR 176.800.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 1 March 2005
Resolution: Both the intermediate and aft cutlass bearings on port propellor shaft were renewed and found satisfactory..
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2004
Resolved
Provide proper operation of navigation lights prior to operation at night or reduced visibility. LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 10 May 2004
Resolution: Lights repaired.
Engineering › Bilge Water Management System › Pump
Issued 19 April 2004
Resolved
Prove proper operation of aft bilge pump float switch. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2004
Resolved 10 May 2004
Resolution: Bilge float switch replaced.
Electrical › Electrical Distribution System (service)
Issued 27 March 2003
Resolved
Provide J-Box for wiring on air conditioning forward. LEGACY COMPONENT DESC: Junction Box
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner provided J box for wiring on A/C.
Lifesaving › Rigid Liferafts
Issued 27 March 2003
Resolved
Replace painter on lifefloat as per 46 CFR 180.175. LEGACY COMPONENT DESC: Painter
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner replace painter on lifefloat.
Lifesaving › Rigid Liferafts
Issued 27 March 2003
Resolved
Stencil lifefloat with vessel name and capacity as per 46 CFR 185.604. LEGACY COMPONENT DESC: Markings
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner stenciled lifefloat with name and capacity.
Stability › Watertight Integrity
Issued 27 March 2003
Resolved
Replace plastic plug on overboard discharge @ stbd engineroom with metallic. LEGACY COMPONENT DESC: Overboard Discharge
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner replaced plastic plug on ovbd discharge with metallic plug.
Fire Fighting › Structural - C Class Divisions
Issued 27 March 2003
Resolved
Make E/R bulkheads vapor tight.
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 27 March 2003
Resolution: Owner made E/R bulkheads vapor tight.
Communications › Audible Communications
Issued 27 March 2003
Resolved
Prove proper operation of ship's horn and public address system. LEGACY COMPONENT DESC: Horn/Whistle
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner proved proper operation of ship''s horn and public address system.
Electrical › Electrical Distribution System (service)
Issued 27 March 2003
Resolved
Provide repairs to fwd air conditioning wiring and engineroom wiring IAW 46 CFR 183.1020 LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner provided repairs to A/C and E/R wiring.
Lifesaving › Rigid Liferafts
Issued 27 March 2003
Resolved
Provide 4' paddles for lifefloat IAW 46 CFR 185.604.
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner provided 4'' paddles for lifefloat.
Electrical › Lighting (service)
Issued 27 March 2003
Resolved
Provide guard for light at E/R entrance. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner provided guard for light at E/R entrance.
Engineering › Bilge Water Management System
Issued 27 March 2003
Resolved
Remove excessive slops in E/R bilge.
Action required: 705 - Other - as specified
Due 27 April 2003
Resolved 23 April 2003
Resolution: Owner removed excessive slops in E/R bilge.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 March 2003
Resolved
Prove proper operation of Fixed fire extinguishing system shut down IAW 46 CFR 182.465(h). LEGACY COMPONENT DESC: Control Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 April 2003
Resolved 27 March 2003
Resolution: Owner proved proper operation of Fixed Fire extinguishing system shutdown.
Documentation
Issued 7 May 1998
Resolved
PROVIDE FCC OPERATOR'S LICENSE AS PER 47 CFR 80.155.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 7 May 1998
Resolved
PROVIDE VALID RED CROSS FIRST AID AND CPR CARDS FOR 50% OF DECKHANDS AS PERNVIC 1-91.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Documentation
Issued 7 May 1998
Resolved
PROPERLY POST STABILITY LETTER AND COI AS PER 46 CFR 176.306 AND 176.302.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 7 May 1998
Resolved
RENEW TWO LIFE RING BUOYS AS PER 46 CFR 180.70.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 7 May 1998
Resolved
PROPERLY MARK RING LIFE BUOYS WITH RETROREFLECTIVE TAPE AS PER NVIC 01-87.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 7 May 1998
Resolved
PROVIDE PROPER FIRST AID KIT AS PER 46 CFR 184.710.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Accommodation/Occupational Safety
Issued 7 May 1998
Resolved
INSTALL 30X30 MESH SCREEN IN MSD TANK VENT AS PER 33 CFR 159.95.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Navigation
Issued 7 May 1998
Resolved
RENEW SIDE SHIELD ON PORT RUNNING LIGHT AS PER M16672.2C ANNEX I.5.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Accommodation/Occupational Safety
Issued 7 May 1998
Resolved
MARK UPPER DECK AS PER STABILITY LETTER AS PER 46 CFR 185.602(G).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 7 May 1998
Resolved
ATTACH LANYARDS TO ALL UNHINGED HATCH COVERS AS PER 46 CFR 179.360(A)(2).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 7 May 1998
Resolved
INSTALL FUEL STOP VALVE AT ENGINE END OF FUEL LINE ON STARBOARD MAIN ENGINEAS PER 46 CFR 182.15-40(B)(3).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Navigation
Issued 16 May 1995
Resolved
RENEW PORT AND STBD RUNNING LIGHT LENSES.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Navigation
Issued 16 May 1995
Resolved
RENEW STERN LIGHT
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Construction/Loadline
Issued 16 May 1995
Resolved
REMOVE OIL FROM BILGES
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Documentation
Issued 16 May 1995
Resolved
PROVIDE UPDATED PUBLICATIONS (46 CFR 166-199 AND COLREGS)
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Engineering
Issued 16 May 1995
Resolved
INSTALL A 30 X 30 MESH SCREEN IN FUEL TANK VENTS AND MSD STANK VENT.
Condition: Unknown
Due 16 May 1995
Resolved 16 May 1995
Accommodation/Occupational Safety
Issued 6 May 1992
Resolved
PROVIDE WASTE MANAGEMENT PLANS FOR VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Navigation
Issued 10 March 1992
Resolved
REMOVE TINT FILM FROM ALL PILOTHOUSE WINDOWS.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Engineering
Issued 1 May 1991
Resolved
REPAIR EXHAUST LEAK ON PORT ENGINE EXHAUST PIPING
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Navigation
Issued 1 May 1991
Resolved
RENEW PORT AND STBD RUNNING LIGHT LENS
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Fire Fighting
Issued 1 May 1991
Resolved
PROVIDE PROOF OF FIRE EXTINGUISHER SERVICING WITHIN THE PAST YEAR
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
INSTALL SPLICES TO ALL LINE CONNECTIONS TO LIFE SAVING EQUIPMENT IN LIEU OFKNOTS
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Fire Fighting
Issued 1 May 1991
Resolved
PROVIDE AND INSTALL MARINE TYPE FIRE EXTINGUISHER BRACKEST FOR ALL FIRE EXTINGUISHERS (5 EACH)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991
Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST COOLING SYSTEM OF BOTH MAIN ENGINES AND GENERATOR. SUCH A WARNING DEVICE SHALL BE VISIBLE OR AUDIBLE AT THE ENGINE OPERATION STATION.
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Lifesaving
Issued 1 May 1991
Resolved
PROVIDE HORN
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991
Resolved
REFASTEN ALL TURBO CHARGER HEAT SHIELDS
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991
Resolved
INSTALL FACTORY FITTING TO ALL FUEL LINES TO GENERATOR
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991
Resolved
REMOVE FLEXIBLE HOSE FROM FUEL TANK TO GENERATOR AND INSTALL RIGID PIPING
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Electrical
Issued 1 May 1991
Resolved
REPAIR OR REPLACE FREQUENCY METER TO S/S GENERATOR_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 1 May 1991
Resolved
REMOVE PETCOCKS FORM DAHL FUEL FILTERS AND INSTALL PIPE PLUG_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1991
Resolved 1 May 1991
Engineering
Issued 13 February 1991
Resolved
PROVIDE AND INSTALL U/L APPROVED MARINE TYPE FUEL FILTERS FOR GENERATOR ANDMAIN ENGINE DIESEL ENGINE_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Construction/Loadline
Issued 13 February 1991
Resolved
REPLACE GASKET FOR STERN WATERTIGHT HATCH_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Accommodation/Occupational Safety
Issued 13 February 1991
Resolved
INSTALL PLUG TO 1 INCH BALL VALVE FOR SALTWATER WASH (SPARE)
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991
Accommodation/Occupational Safety
Issued 13 February 1991
Resolved
FREE-UP BALL VALVES ON STARBOARD SIDE SEA SUCTION
Condition: Unknown
Due 13 February 1991
Resolved 13 February 1991