Records from 2001 to 2026. Most recent: inspection, 11 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 49
11 March 2026
Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8324315
16 July 2025
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8182614
8 May 2025
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8110223
19 February 2025
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8056617
20 November 2024
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8037387
22 August 2024
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7986186
9 May 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7906086
14 February 2024
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7865556
11 October 2023
Administrative Inspection · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7805933
13 July 2023
Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7741560
19 April 2023
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7671448
17 January 2023
MTSA Verification · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7622136
19 October 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7580168
21 July 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7528675
21 April 2022
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7435925
19 January 2022
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7378524
20 October 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7337662
29 July 2021
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7271339
26 May 2021
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7207655
22 April 2021
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7180278
12 January 2021
COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7123490
30 January 2020
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6899217
17 October 2019
MTSA Verification · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6836438
25 July 2019
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6761295
2 May 2019
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6675384
30 January 2019
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6617208
25 October 2018
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6568233
22 October 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6565594
19 July 2018
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6484346
1 May 2018
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6403258
9 January 2018
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6334620
16 October 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6288284
5 October 2017
Administrative Inspection · Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6284962
13 April 2017
Re-Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6123603
20 March 2017
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6107813
14 January 2017
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6071748
11 January 2017
COI Inspection · Security Plan Review - VSP
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6069416
21 December 2016
Load Line/Change of Employment
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6060872
28 November 2016
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6054752
23 November 2016
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6046658
23 November 2016
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6048240
14 November 2016
Damage Survey · Permit to Proceed
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6042615
22 September 2016
Re-Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6007110
7 September 2016
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5994712
5 August 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5963339
14 June 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5996530
29 April 2016
Hull Examination · Internal Structural Exam · Load Line/Change of Employment
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5867172
26 April 2016
Load Line/Change of Employment
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5863236
17 February 2016
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5817012
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 January 2023
Resolved
All engine designs installed shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. #1 Main Engine cylinder cover rusted and leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2023
Resolved 2 February 2023
Resolution: Observed a renewed cylinder cover on the #1 Main Engine. SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2022
Resolved
Electric installations on vessels must ensure protection of crew. Vessel has ground on main 230v bus. Vessel is required to isolate and permanently remove ground for the safety of crew, passengers and vessel to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2022
Resolved 21 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 January 2022
Resolved
At least one-half of the total number of lifebuoys on the vessel must each be fitted with a self igniting light approved under approval series 161.010. Found expired batteries in lifebuoy self igniting lights. Replace all lights with approved batteries to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2022
Resolved 21 January 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2022
Resolved
Each bus tie between the main switchboard and emergency switchboard must disconnect automatically upon loss of potential at the emergency switchboard, the auto bus transfer switch between the EDG bus and main bus is not working as designed and must be repaired/replaced to good working condition.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2022
Resolved 2 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 19 January 2022
Resolved
The hurricane deck (weather deck) deck drains are backing up to the interior passenger spaces. The weather deck must have freeing ports to allow rapid clearing of water under all weather conditions. In addition the excessive water on the deck pose a slip trip and fall hazard to passenger and crew. Prior to getting underway with passengers demonstrate that the deck drains on the hurricane deck flow freely and do not back up into any other space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 January 2022
Resolved 2 February 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 19 July 2018
Resolved
Pipe, tubing, pipe joining fittings, and piping system components, shall meet material and standard requirements of subpart 56.60 and shall meet the certification requirements of part 50 of this subchapter. The vessel has a pinhole leak in its bilge/fire main piping system. Properly repair and prove proper operation.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 July 2018
Engineering › Fuel Oil Service System › Piping
Issued 16 October 2017
Resolved
Vessel has a fuel leak that can not be stopped. Vessel must submit repair proposal and make proper repairs. 46CFR71.55-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2017
Resolution: Vessel installed new fuel lines and tested under normal operating pressure.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 20 March 2017
Resolved
Electrical installations on vessels must ensure:(1)Maintenance of services necessary under normal & emergency conditions; (2) Protection of passengers, crew, other persons & the vessel from electrical hazards. Vessel will remain out of service until starter repairs are made and tested to the satisfaction of the attending CG Marine Inspector. 46 CFR 111.01-1(a) (1) & (2)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 March 2017
Resolved 20 March 2017
Resolution: starter was replaced and tested
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 14 January 2017
Resolved
Fuel line 90 degree fitting leading to the #4 cylinder injector was fractured leading to a fuel leak.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2017
Resolution: Fitting was replaced and tested satisfactory.