Records from 2016 to 2022. Most recent: inspection, 6 September 2022.
Documentation record
Registered dimensions (L × B × D)27.5 ft × 12.1 ft × 4.6 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND HOPPER INC · MARATHON SHORES, FL, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portZEPHYR COVE, NV
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 April 2021
Resolved
The Certificate of Inspection and Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible in a conspicuous place on the vessel where observation by passengers is likely.
46 CFR 176.302/46 CFR 176.306
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator posted COI/Stability Letter in vessel's cabin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 April 2021
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. The arrangement of the retroreflective material applied after March 11, 1996 must be as specified by IMP Resolution A.658(16). Discovered 05 adult life jackets did not have retroreflective material on one side of each life jacket.
46 CFR 185.604(h)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator sent photograph of additional retroreflective material for all sides of called out life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 27 April 2021
Resolved
The number of persons capacity and vessel’s name must be marked or painted in clearly legible letters and numbers on each life float. Discovered that the life float onboard did not contain the number of persons and the vessel’s name.
46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator sent photographs of properly marked life float.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 April 2021
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least .5 inches high “DISTRESS SIGNALS”. Discovered that the vessel’s portable watertight container containing the vessel’s distress flares was labeled “FLARES”.
46 CFR 185.614
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 May 2021
Resolved 27 April 2021
Resolution: Operator sent photograph of properly marked "DISTRESS SIGNALS" watertight container.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Teh manual powered bilge manifold was missing a valve handle for the FWD compartment. Replace the handle IAW 46CFR182.500(a).
46CFR182.500(a)
Action required: 10 - Deficiency Rectified
Due 12 May 2020
Resolved 12 May 2020
Resolution: The valve handle was replaced to the satisfaction of the Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 June 2019
Resolved
Except as allowed by paragraphs (e) and (f) of this section, each vessel construction of a material other than wood certificated to operate on a lakes, bays, and sounds route in cold water must be provided with life floats of an aggregate capacity that will accommodate at least 50 percent of the total number of persons permitted onboard. Inner sections of life float are tearing and are in need of service. Vessel is restricted from carriage of passengers until repaired.
46 CFR 180.200 (c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2019
Resolved 12 September 2019
Resolution: Vessel rep sent MI picture of new life float.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 25 June 2019
Resolved
Each fire drill must include: (3) Instruction in the use and location of fire alarms, extinguishers, and any other fire fighting equipment onboard. Vessel needs instructions on board indicating that the ignition must be turned in order to use FIREBOY override function.
46 CFR 185.524
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 July 2019
Resolved 12 September 2019
Resolution: Vessel rep sent MI picture of instructions for FIREBOY system posted near operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2019
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets were not stowed separately from the adult life jackets on board at the time of inspection.
46 CFR 180.78 (a)(5)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 25 June 2019
Resolved 25 June 2019
Stability › Weathertight Integrity › General
Issued 6 June 2017
Resolved
Aft Hatch, fuel fill, and Emergency Fuel Shutoff Accesses are not weathertight. All three openings need to be resealed. 46 CFR 171.24
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 18 June 2017
Resolution: Weathertight Hatch, Fuel Fill, and Emergency Shutdown Access were fitted and resealed.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 June 2017
Resolved
Applicable section of Coast Pilot is not onboard. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 10 July 2017
Resolution: Provided US Coast Pilot.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 June 2017
Resolved
Applicable section of light list is not onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 10 July 2017
Resolution: Provided Light List.
Navigation › Piloting/Steering › Marine Charts
Issued 6 June 2017
Resolved
Vessel does not have applicable updated Marine Charts onboard. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 10 July 2017
Resolution: Provided Charts.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 June 2017
Resolved
Vessel does not have a copy of inland Navigation Rules onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2017
Resolved 10 July 2017
Resolution: Provided Inland Navigation Rules.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 6 June 2017
Resolved
Emergency Brodcast Placard is not Posted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 June 2017
Resolution: Emergency Broadcast Placard Installed.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 6 June 2017
Resolved
Vessel is missing 5 Adult size life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 June 2017
Resolution: 5 new adult life jackets were labled and properly stowed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 June 2017
Resolved
Life Jacket Placard is not posted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 June 2017
Resolution: Life Jacket Placard is displayed.
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 6 June 2017
Resolved
Chains are missing from port and starboard rails at embarkation points.46 CFR 177.35-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 10 July 2017
Resolution: Installed Chains at embarkation points.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 June 2017
Resolved
Vessel does not have appropriate means for securing ventilation to the Engine Room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 June 2017
Resolution: Plugs were provided and stowed near vents for securing ventilation.
Fire Fighting › Fire Bucket › Quantity
Issued 6 June 2017
Resolved
Fire Buckets were not on vessel. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 18 June 2017
Resolution: Fire Buckets provided.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 June 2017
Resolved
Forward Engineroom Bulkhead contained hole exposing Engine Room to an accomodation space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2017
Resolved 10 July 2017
Resolution: Filled hole with fire stop.