Records from 1986 to 2025. Most recent: inspection, 15 December 2025.
Inspection history · 88
15 December 2025
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8283343
24 July 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8193358
23 July 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8192847
13 July 2025
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8197652
30 July 2024
Administrative Inspection · In-Service Inspection · Drydock Exam · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7970317
19 September 2023
COI Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7786781
8 June 2023
In-Service Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7709493
17 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7624043
8 November 2022
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7591612
4 April 2022
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7424054
8 February 2022
Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7407808
16 November 2021
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7352203
1 March 2021
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7146777
14 January 2021
Internal Structural Exam · Drydock Exam · Examination of Repairs · Construction Oversight · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7124958
27 August 2020
Drydock Extension
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7044811
8 November 2019
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6852077
7 August 2019
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6777545
7 August 2019
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6790348
2 March 2018
Construction Oversight · Inclining Experiment · Deficiency Check · COI Inspection · Examination of Repairs · DAPI Audit · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6368051
17 March 2017
Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6110140
28 January 2017
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6080304
15 November 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6044002
16 December 2015
Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5783238
17 November 2015
MTSA Verification · Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5765550
7 October 2014
Annual Inspection · MTSA Verification · DAPI Audit · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5000686
25 August 2014
Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4965211
13 February 2012
Administrative Inspection · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4243674
12 March 2009
Administrative Inspection · Deficiency Check · Construction Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3448982
22 August 2008
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3305817
30 July 2008
Inclining Experiment
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3289566
27 November 2007
Hull Examination · Inclining Experiment · COI Inspection · Administrative Inspection · Construction Oversight · MTSA Verification · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3104706
26 September 2007
Administrative Inspection
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 3071362
2 July 2007
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2980883
1 February 2006
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2576281
9 February 2005
Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2287737
8 December 2004
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2255727
23 November 2004
Hull Examination · Internal Structural Exam
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 2247044
11 August 2004
MTSA Verification
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2162324
10 May 2004
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2063690
5 May 2004
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2059522
22 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970968
5 August 2003
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1867115
4 February 2003
COI Inspection
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1740862
10 December 2001
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1395847
3 April 2001
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1382362
31 March 2000
Damage Survey · Examination of Repairs
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1455837
10 March 2000
SIP Initial Entry
Administrative · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 2878315
3 February 2000
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1393347
20 January 2000
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1045635
14 January 2000
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1453705
5 January 2000
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 813518
29 December 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 812186
13 December 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1420237
19 October 1999
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1418623
16 March 1999
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1388930
30 June 1998
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 794117
27 April 1998
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1458516
23 May 1997
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1113773
24 April 1997
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1430387
28 March 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1097898
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099863
20 December 1996
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1094349
14 May 1996
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1084010
6 May 1996
Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1085868
5 May 1996
Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 105215
20 March 1996
Deficiency Check · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1078541
24 March 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 849441
9 March 1995
Hull Examination
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1374226
17 March 1994
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 855932
20 July 1993
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1152015
13 May 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 835282
7 May 1993
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1423773
6 May 1993
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1134989
18 March 1993
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1452933
14 December 1992
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1139569
28 April 1992
Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1257841
17 March 1992
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1011175
18 November 1991
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1246730
26 June 1991
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 911104
19 March 1991
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 928378
10 July 1990
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1243011
22 March 1990
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 903630
28 April 1989
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1194466
23 March 1989
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1352785
1 April 1988
COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1317332
30 June 1987
COI Inspection
Physical examination · MSO NASHVILLE · Activity 1010434
4 June 1987
Administrative
Administrative · MSO NASHVILLE · Activity 1029323
2 July 1986
Credit Drydock · Initial Certification
Physical examination · MSO NASHVILLE · Activity 1306155
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2025
Resolved
Must check the settings of the safety or relief valves on all pressure vessels, twice every 5 years. No more than 3 years.
Relief valve on pressure vessel has no evidence or documentation of testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 30 December 2025
Resolution: Forest Urick submitted photos of installation of new relief valve for the proper PSI and CFM.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 December 2025
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type. A space containing propulsion machinery.
Operator provided inspection results indicating horn strobe inside battery room is functional audibly but not visually.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 30 December 2025
Resolution: Forest Urick provided video of audible and visual alarm system for battery room.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 December 2025
Resolved
Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered automatically operated lights.
Batteries in 05 emergency lights were discharged.
46 CFR 184.30-5(b)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 30 December 2025
Resolution: Photos provided for new installation of 05 emergency lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 February 2025
Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT drug testing regulations. Compliance with these provisions is a material term of all such agreements and arrangements. 46 CFR 16.203(a)(3)
DAPI consortium enrollment expired December 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: Received letter from CHECKR indicating that Aramark - Fort Sumter Touors - is an active member of the USCG drug and alcohol testing program. Valid until 31DEC2025.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 February 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard Light List. Extracts from the publication may be provided instead of the complete publication. 46 CFR 121.420(a)
Vessel was not equipped with an up-to-date light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: Vessel's rep provided photographic evidence that extracts from the Light List and Coast Pilot are current.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2025
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 164.018 in subchapter Q of this chapter. 46 CFR 122.604(i)
Retro-reflective material on all ring life buoys found to be excessively degraded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Retro-reflective material refreshed on all liferings.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 February 2025
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. 46 CFR 121.502
Call sign on the Safety Radiotelephony Certificate and the Bridge-to-Bridge Radiotelephony Certificate do not match with the FCC Station License.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2025
Resolution: Vessel provided Inspectors with copies of the updated Safety Radiotelephony and the Bridge-to-bridge Radiotelephony Certificates.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 February 2025
Resolved
A self-propelled vessel of 65 feet or more in commercial service, must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. 33 CFR 164.46(b)
AIS broadcasting incorrect call sign and vessel type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2025
Resolution: Verified that company updated AIS info with NAVCEN.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2025
Resolved
The emergency lighting must automatically actuate upon failure of the main lighting system. 46 CFR 120.432(b)
Emergency light on the port side bulkhead of the engine room at the base of the stairs was energized while power was on to the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Malfunctioning emergency light replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 February 2025
Resolved
A-Class bulkheads must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test the average temperature on the unexposed side does not rise more than 250 degrees F. 46 CFR 116.415(a)(2)(i)
The A-60 insulation was not present around the watertight door between the machinery space and the battery room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: A-60 insulation replaced around watertight door beetween the machinery space and the battery room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 46 CFR 117.71(a)
5 life jackets found damaged. Passenger maximum is reduced to 520 until replacement life jackets are put into service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Replaced the 5 damaged life vests.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. 46 CFR 120.220(a)
Main engine emergency shutdown panel not fastened to console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: ESD panel in wheelhouse has been properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025
Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers. 46 CFR 116.800(a)
Materials used to replace the generator need to be removed from the vessel prior to carrying passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Crew removed the materials used to replace the generator from the vessel.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 19 September 2023
Resolved
A manned oceangoing ship of 40 feet or more in length that is documented under the laws of the United States or numbered by a state and that either is engaged in commerce or is equipped with a galley and berthing requires a Garbage Management Plan. Vessel missing Garbage Management Plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 November 2023
Resolution: A waste management plan was placed on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 19 September 2023
Resolved
The fire control plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. The fire control plan was missing areas of refuge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 20 November 2023
Resolution: Areas of safe refuge were highlighted on the Fire Control Plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 September 2023
Resolved
Tests must verify that automated vital systems are designed, constructed, and operate in accordance with all applicable requirements of part 62 of this sub chapter. Subsequent Automation Testing should be in accordance with the MSC approved DVTP at the discretion of the attending marine inspector for cause and at least once every 5 years IAW CG CVC Policy Letter 17-07. Vessel has not completed design verification test procedures and scheduled to complete them on 16NOV2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 20 November 2023
Resolution: Observed satisfactory test of the PSTPs for the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 June 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] doors and hatch from battery room not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 26 June 2023
Resolution: installed signs in the appropriate places
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 November 2022
Resolved
A space containing propulsion machinery must be equipped with a fire detection and alarm system of an approved type. The fire detection system in the battery room was not functioning as designed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2022
Resolved 15 November 2022
Resolution: Vessel operator provided documentation of servicing of the smoke detection system. Deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 November 2022
Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. The strainer and associated piping used for cooling the battery installation is leaking. Deficiency to be rectified within 7 days.
Action required: 705 - Other - as specified
Due 21 November 2022
Resolved 28 November 2022
Resolution: Vessel operator provided photograph of satisfactorily replaced piping to the strainer. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2022
Resolved
Each life jacket mist be marked with Type I retroreflective material. 09 child life jackets and 01 adult life jacket are in need of retroreflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2022
Resolved 16 November 2022
Resolution: Vessel operator provided documentation of retroreflective tape replaced on life jackets. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 November 2022
Resolved
A door in stair-tower, stairway, and man vertical zone bulkhead must be of the self-closing type capable of closing against a 3.5 list of the vessel. The fire door to the engine room could not close as designed. Deficiency rectified at next drydock.
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 10 February 2025
Resolution: Inspectors checked the function of the self-closing doors in both stairways entering the machinery space and found both to be functioning as required.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 16 November 2021
Resolved
Except when operating on lakes, bays, and sounds, or river routes in calm weather, all hatches and openings in the hull, except loading doors, of a vessel must be kept tightly closed except when being used. Watertight door from battery room to engine room did not have all points of contact when dogged down.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 5 January 2022
Resolution: Video Submitted showing full contact chalk test, and paper failing to be slipped through on water tight door dogs.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 November 2021
Resolved
A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead. Starboard door leading to engine room was missing sufficient insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted images of door being repaired.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 November 2021
Resolved
Vessel must follow approved structural fire protection detailed plans. Vessel's battery room hatch was missing adequate structural fire protection insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted media of def rectified.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 November 2021
Resolved
The minimum capacity of the power pump shall be 50 gallons per minute at a pressure of not less than 60psi. During test of fire pump, gauge read 50psi.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted video of fire pump operating and reading 60psi at the guage.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2021
Resolved
All wiring shall be run as high as practicable above bilges. Wires hanging from ceiling 3ft from bilge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted image of wires being secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2021
Resolved
Wire joints and splices shall be mechanically secure and in junction boxes. Vessel security camera cable is splices and bundled with duct tape loosely hanging in engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2021
Resolved
The number and identification of items stowed inside must be clearly marked on each container. Adult and child life jacket totals were mislabeled on container.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2021
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 02 adult lifejackets were taken out of service. Vessel restricted to 543 adults total until 02 adult lifejackets added onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2021
Resolved
Each lifejacket carried on board must be marked in accordance with 46CFR122.604. Ensure all lifejackets are clearly labeled with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2021
Resolved
All electrical installations shall be to the satisfaction of the OCMI. Vessel had inoperable lighting in the lifejacket stowage closet on the main deck, as well as in the battery room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 March 2021
Resolved
A power driven vessel underway shall exhibit a masthead light forward, a second masthead light abaft of and higher than the forward one, sidelights, and a sternlight.
Starboard running light and sternlight were non-operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2021
Resolved
A door in a bulkhead required to be A-0 Class must be of solid or hollow steel or equivalent material construction, and capable of meeting the requirements of an A-0 Class bulkhead.
A-0 door to the machinery space must be self-closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, heat resistivity as that afforded by the hull may be approved. Hole in bilge piping needs to be repaired. Prove proper operation to the Marine Inspector. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 December 2019
Resolved 13 December 2019
Resolution: Bilge piping was replaced and function test was conducted with satisfactory results.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] manufacturers data report for pressure tank (air receiver) in engine room needs to be provided to USCG. 46 CFR 119.330
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2019
Resolved 31 January 2020
Resolution: Recieved U-1A for new pressure vessel. see vessel documents
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
This part is intended to provide a minimum standard of
regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment. Provide a light switch cover plate in
scullery. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Cover plate was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Lighting in holds needs to be in working condition. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: All lighting was repaired in the hold spaces.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 December 2019
Resolved
Vessel required to have bilge high level alarm. Bilge high level alarm probe needs to be mounted. 46 CFR 119.530
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Bilge high level was secured to framing in the bilge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 December 2019
Resolved
The Rules concerning shapes shall be complied with by day. Day shapes required onboard vessel (three black balls).
33 CFR 83.20(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Day shapes were place inservice
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 December 2019
Resolved
A vessel must carry adequate and up-to-date charts and nautical publications. The following need to be updated to newest version: Charts, U.S. Coast Pilot [name withheld] List, , Inland Navigation Rules. 46 CFR 121.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Charts, U.S. Coast Pilot [name withheld] List, Inland Navigation Rules were updated.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
The materials and construction of fuel lines must comply with the requirements of tis paragraph. Remove hose from fuel stripping line and place plug in valve. 46 CFR 119.455
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: hose from fuel stripping line removed and plug placed in valve.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
The intent of this part is to insure the main propulsion machinery is suitable for the vessel and its operation. Need bolts for the glycol and seawater pump mounts are missing/broken. 46 CFR 182.01-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: bolts for the glycol and seawater pump mounts are installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
Have vessel ready for inspections of hull structure and its appurtenances, including inspection of all accessible parts of the exterior and interior of the hull. Fixed ballast in forward peak has four broken welds fix during next dry-dock. 46 CFR 115.802
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 7 April 2022
Resolution: Resolved during the same activity during follow up.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Required to have 545 adult life jackets, 31 have been taken out of service or need new retro reflective tape. Restricted to 514 passengers onboard until the 31 missing lifejackets are onboard. 46 CFR 117.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2020
Resolved 13 February 2020
Resolution: 31 life jackets were placed inservice onboard the vessel bringing life jacket count to required 545.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2019
Resolved
Propulsion machinery shall be suitable in type and design for prpulsion requirements.
Vessel had failures in cooling water system required by the hybrid propulsion system.
Repair and conduct satisfactory sea trail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2019
Resolution: Conducted satisfactory repairs by installing dedicated motor controllers for each of the cooling water pumps of the hybrid propulsion system with satisfactory sea trail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2019
Resolved
Installation of propulsion machinery of an unusual type for small passenger vessel must be given seperate consideration.
Resubmit to MSC affacted dwg by the modifications made to the system not limited to one line block, qualitative failure anylysis, and periodic safety procedures.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 1 October 2019
Resolution: Recieved notification that m/v THE SPIRIT OF THE LOW COUNTRY, O.N. 699243, Serodino Hull No 62, P013740 was submitted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
Vessel missing 5 lifejackets, restricted to 522 pax until new lifejackets are onboard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 14 November 2019
Resolution: Replaced life jackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2018
Resolved
Vessel battery bank throwing voltage fault, vessel restricted to running diesal electric until technician arrives and corrects issue. Crash test and battery propulsion mode to be tested in presence of marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 1 October 2018
Resolved
Emergency instruction list missing info on fires in battery room. Vessel to update and post.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 14 November 2019
Resolution: Posted instructions
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2018
Resolved
Fire extinguisher in galley missing bracket. Replace/repair to satisfaction of USCG.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2018
Resolved
Vessel replaced pressure tank (air reciever) in engine room. ASME manufacturers data report to be provided to USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 13 February 2020
Construction/Loadline › Structures › Deck Plating
Issued 17 March 2017
Resolved
C/R area in steering space aft riser to remove pitting on existing weld seam. Clad welded as temp repair during March 2017 dry dock.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 14 November 2019
Resolution: Verified insert was conducted to close outstanding deficiency
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 15 November 2016
Resolved
Clean Port/Stbd genset armatures
Due 15 December 2016
Resolved 30 November 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 November 2016
Resolved
Clean corrosion off battery cables.
Due 15 December 2016
Resolved 30 November 2016
Engineering › Fuel Oil Service System › Filter
Issued 15 November 2016
Resolved
Remove excess oil from Racor filter bowl on Stbd genset.
Due 15 December 2016
Resolved 30 November 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 November 2016
Resolved
Replace emergency light on 01 deck.
Due 15 December 2016
Resolved 30 November 2016
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 November 2016
Resolved
Renew injection T bar for cooling injection on port shaft dripless cutleass bearing & make vessel available for MOB drills.
Due 30 November 2016
Resolved 30 November 2016
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 November 2015
Resolved
Print 2015 Light List for operational area.
Due 17 December 2015
Resolved 16 December 2015
Navigation › Piloting/Steering › Marine Charts
Issued 17 November 2015
Resolved
Obtain currently corrected chart or correct chart onboard of operational area.
Due 17 December 2015
Resolved 16 December 2015
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 November 2015
Resolved
Log lifesaving equipment maintenence repairs/checks.
Due 17 December 2015
Resolved 16 December 2015
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 November 2015
Resolved
Renew valve handle & wire clamps.
Due 17 December 2015
Resolved 16 December 2015
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 17 November 2015
Resolved
Clean both generator armatures.
Due 17 December 2015
Resolved 16 December 2015
Electrical › Electrical Distribution System (service) › Panelboard
Issued 17 November 2015
Resolved
properly label engine room electrical panel box.
Due 17 December 2015
Resolved 16 December 2015
Fire Fighting › Means of Escape › Escape Route Signs
Issued 17 November 2015
Resolved
Remove Emergency Exit signs from doors not serving this function on 01 deck.
Due 17 December 2015
Resolved 16 December 2015
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 7 October 2014
Resolved
Make air receiver available for internal inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2014
Resolution: A satisfactory inspection was conducted on the vessel''s air receiver.
Engineering › Bilge Water Management System › Strainer
Issued 7 October 2014
Resolved
Provide strainers for the two forward compartment bilge suctions.
Condition: Improper/Lack of Maintenance
Due 24 October 2014
Resolved 23 October 2014
Resolution: New strainers were placed in service.
Construction/Loadline › Structures › Door
Issued 7 October 2014
Resolved
Properly mark inside of the E/R QAWTD.
Due 24 October 2014
Resolved 23 October 2014
Resolution: The inside of the QAWTD was labled correctly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 October 2014
Resolved
Show proper operation of the vessel's anchor light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2014
Resolution: Vessel owner showed proper operation of the anchor light.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 7 October 2014
Resolved
Replace retroflective material on child size lifejackets.
Due 24 October 2014
Resolved 23 October 2014
Resolution: Retroflective material was placed on the identified child size lifejackets.
Fire Fighting › Fire Hydrants › Location/Position
Issued 7 October 2014
Resolved
Label fire stations to match Fire Plan.
Due 24 October 2014
Resolved 23 October 2014
Resolution: Fire Station 3 was properly labled to match the Fire Plan.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 7 October 2014
Resolved
Provide annual service for elevator.
Due 24 October 2014
Resolved 23 October 2014
Resolution: The vessel''s elevator received annual servicing.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 November 2007
Resolved
Handle on Lifejacket stowage container missing on upper deck stack
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Handle replaced on container
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 November 2007
Resolved
Vessel Safety Control plan needs to be updated and mounted
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Had updated vessel safety plan and properly mounted
Communications › Public Address System › Announcing Station
Issued 27 November 2007
Resolved
P/A system was not connected to emergency power which serves as thier emergency notification system
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2008
Resolution: connected P/A system to emergency power
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2007
Resolved
Starboard search light bulb out
Condition: Improper/Lack of Maintenance
Due 20 August 2008
Resolved 20 August 2008
Resolution: Replaced light bulb
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 27 November 2007
Resolved
repair open ground on 110 Volt outlets located in front of bar, fwd bulkhead both port and starboard
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Electrical grounds repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2007
Resolved
Upper deck light fixtures exposed with no light bulbs. Unsecured wiring in heads.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Completely removed unused light fixtures and properly secured wiring on upper deck and in the heads.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 27 November 2007
Resolved
Reverse polarity in 110 Volt outlet located main deck, starboard side, amidships
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Outlet repaired and operating correctly
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 November 2007
Resolved
No plugs on the non-used thru hull penetrations
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Properly plugged all thru hull penetrations
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 November 2007
Resolved
Missing high level bilge alarm in forward void space
Condition: Placed in Improper Service
Due 20 August 2008
Resolved 20 August 2008
Resolution: Properly installed and labeled high level bilge alarm
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 27 November 2007
Resolved
vessels toilets OOC
Due 20 August 2008
Resolved 20 August 2008
Resolution: all toilets operational
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2007
Resolved
Vessels forward void and aft steering space missing light covers
Due 20 August 2008
Resolved 20 August 2008
Engineering › Compressed Air System (control) › Valve
Issued 27 November 2007
Resolved
missing relief valve on air compressor
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 November 2007
Resolved
Missing emergency lighting in vessels engine room escape ladders, both stbd and port. Emergency light OOC in engine room forward. Label all emergency lighting with E.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Resolution: Emergency lighting fixed, installed, and properly labeled.
Engineering › Fuel Oil Service System › Filter
Issued 27 November 2007
Resolved
Replace plastic fuel bowls on number 1 and 2 SSDG
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2008
Resolution: Plastic bowls replaced with metalic bowls
Electrical › Lighting (service) › Switch
Issued 27 November 2007
Resolved
Missing light switch cover in steering space
Condition: Improper Installation
Due 22 August 2008
Resolved 22 August 2008
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 27 November 2007
Resolved
Vessel is short 65 Adult Type 1 lifejackets due to updated stability test
Action required: 705 - Other - as specified
Due 15 September 2008
Resolved 5 September 2008
Resolution: Added 65 universal lifejackets.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 November 2007
Resolved
extiguished not mounted
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2008
Engineering › Bilge Water Management System › Manifold
Issued 27 November 2007
Resolved
Bilge manifold not labeled
Due 20 August 2008
Resolved 20 August 2008
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 27 November 2007
Resolved
Repair, Replace loose or Missing insulation in Engine Room overhead
Condition: Improper Installation
Due 27 August 2008
Resolved 3 September 2008
Resolution: Replaced missing insulation
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 27 November 2007
Resolved
Designate senior deck hand in writing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2008
Resolution: Cleared
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 November 2007
Resolved
Update vessels fire control plan and safety plan to match vessels current arrangement
Condition: Placed in Improper Service
Due 27 August 2008
Resolved 22 August 2008
Construction/Loadline › Penetrations › Bottom Plug Packing
Issued 27 November 2007
Resolved
Missing stuffing tubes in engine room bulkhead. PVC penetration in engine room bulkhead must be removed.
Condition: Placed in Improper Service
Due 27 August 2008
Resolved 3 September 2008
Resolution: Repaired bulkhead
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 November 2007
Resolved
Move all wiring into A/C system control box including external transformer.
Condition: Improper Installation
Due 27 August 2008
Resolved 3 September 2008
Resolution: Corrected a/c wiring
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 27 November 2007
Resolved
Test vessels MDE and Generator Alarms including all sensors and wiring
Due 1 September 2008
Resolved 5 September 2008
Resolution: General Diesel repaired alarms
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 27 November 2007
Resolved
rid ship of all plastic garbage cans
Due 1 September 2008
Resolved 3 September 2008
Resolution: Non combustible trash cans
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 27 November 2007
Resolved
Rid current man overboard ladder with a more appropriate and safe way to recover person from water
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2008
Resolution: Replaced old ladder with a cargo net
Electrical › Lighting (emergency) › Switch
Issued 27 November 2007
Resolved
Missing emergency lighting in vessels elevator
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2008
Resolved 3 September 2008
Resolution: Installed emergency lights
Construction/Loadline › Hull
Issued 5 August 2003
Resolved
Vessel must have a corrosion survey completed to determine the cause and corrective actions needed to stop/arrest corrosive action to hull of vessel in way of P&S a/c, main engine, generator coolers. upon completion of survey report shall be submitted to [name withheld] to be completed by a certified. LEGACY COMPONENT DESC: Side Shell
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 March 2004
Resolved 5 May 2004
Resolution: Vessel owner submitted corrosion survey to CID and stated vessel will be dry-docked in October to correct prblems noted in survey.
Electrical
Issued 27 April 1998
Resolved
Provide blank for the breaker panel located outside the galley on main deckport side.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Construction/Loadline
Issued 27 April 1998
Resolved
Renew the gaskets to the hatch covers to the number 1, 2 and stern voids.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Engineering
Issued 27 April 1998
Resolved
Hydrostatically test the air tank.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 27 April 1998
Resolved
Conduct emergency man overboard drill.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Accommodation/Occupational Safety
Issued 24 April 1997
Resolved
PERFORM HOUSEKEEPING UNDER BAR, UPPER DECK FORWARD.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Electrical
Issued 24 April 1997
Resolved
INSTALL SWITCHPLATE ON OUTLET, UPPER DECK BAR.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 24 April 1997
Resolved
INSTALL METALLIC HULL PENETRATION FOR GRAY WATER OVERBOARD DISCHARGE IN AFTCOMPARTMENT, STEERING FLAT.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Accommodation/Occupational Safety
Issued 24 April 1997
Resolved
Install grating on ventilation supply duct on port side aft.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Electrical
Issued 24 April 1997
Resolved
INSTALL TWO BLANKS ON POWER PANEL, PORTSIDE, MAIN GALLEY AFT.
Condition: Unknown
Due 23 May 1997
Resolved 28 April 1997
Electrical
Issued 24 April 1997
Resolved
INSTALL PLATE COVERING BUS BAR OF PANEL C-2, PORT SIDE, STOREROOM FWD OF MAIN PROP.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Electrical
Issued 24 April 1997
Resolved
DEMONSTRATE PROPER OPERATION OF EMERGENCY LIGHTS, SECOND DECK MIDSHIPS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 6 May 1996
Resolved
VESSEL MAY CARRY PASSENGERS IAW O/O PROPOSAL DATED 07MAY96. REMAINING PROPULSION ENGINE MUST BE IN IMMEDIATE STANDBY TO ENGAGE IN THE EVENT OF ANEMERGENCY.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Engineering
Issued 6 May 1996
Resolved
ANY OPERTATIONAL CHANGES DEVIATING FROM O/O PROPOSED OPERATIONS DATED 07MAY96 MUST BE TO THE SATISFACTION FO THE OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Lifesaving
Issued 20 March 1996
Resolved
ISSUED CG835 REQUIREMENT FOR VESSEL TO CONDUCT UNDERWAY DRILLS TO USCG SATISFACTION NLT 19APR96
Condition: Unknown
Due 19 April 1996
Resolved 17 April 1996
Lifesaving
Issued 24 March 1995
Resolved
PROVIDE CHAIN GUARD ON STEERING CABLE-CHAIN-SPROKET ASSEMBLY 2ND DECK FORWARD IMMEDIATELY BELOW PILOT HOUSE.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Lifesaving
Issued 24 March 1995
Resolved
CONDUCT SATISFACTORY UNDERWAY DRILLS.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Accommodation/Occupational Safety
Issued 24 March 1995
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF FWD MEN AND WOMEN'S RESTROOM FACILITIES.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Documentation
Issued 13 May 1993
Resolved
Provide evidence that the vessel has applied to a U.S. Coast Guard Documentation Officer for an official change of name and hailing port designation._x001C_ 46 CFR 67.25-3 & 46 CFR 67.25-5
Condition: Unknown
Due 13 May 1993
Resolved 13 May 1993
Construction/Loadline
Issued 18 March 1993
Resolved
PROPERLY LABEL PORT AND STBD BOW WITH VESSEL NAME.
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Lifesaving
Issued 18 March 1993
Resolved
PROPERLY LABEL ALL RING BUOYS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Construction/Loadline
Issued 18 March 1993
Resolved
PROPERLY LABEL ALL BILGE PIPING AT THE BILGE MANIFOLD.
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Navigation
Issued 18 March 1993
Resolved
PROPERLY ALIGN NAVIGATION LIGHTS TO MEET NAVIGATION RULES. LIGHTS ARE AT THE LOWER PORTION OF LENS. NEEDS TO BE IN THE MIDDLE._x001C_ _x001C_ COMDTINST M16672.2B_x001C_
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Lifesaving
Issued 18 March 1993
Resolved
VESSEL IS RESTRICTED TO 394 PASSENGERS DUE TO INSUFFIENT PFDs._x001C_ _x001C_ _x001C_ 46 CFR 180.25-5
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Lifesaving
Issued 18 March 1993
Resolved
PROVIDE ONE RING BUOY WITH A 60 FOOT LINE._x001C_ _x001C_ _x001C_ 46 CFR 180.30-10
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Construction/Loadline
Issued 18 March 1993
Resolved
PROVIDE A 3 INCH COAMING ON ALL MAIN DECK WEATHERTIGHT DOORS GIVING ACCESS TO BELOW DECK COMPARTMENTS._x001C_ _x001C_ 46 CFR 171.124(d)
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Construction/Loadline
Issued 18 March 1993
Resolved
MAKE PROPER REPAIRS TO BILGE PUMP TO MEET THE 50 GPM REQUIREMENT._x001C_ _x001C_ _x001C_ 46 CFR TABLE 182.25-10(a)
Condition: Unknown
Due 18 March 1993
Resolved 18 March 1993
Electrical
Issued 17 March 1992
Resolved
CLEAR BOXES FOR ACCESS TO PANEL "E" ON THE TENNESSEE DECK AND LABEL CIRCUITS IN THE ADJACENT PANEL.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Construction/Loadline
Issued 17 March 1992
Resolved
INSTALL PIPE PLUGS IN UNUSED OVERBOARD DISCHARGE THROUGH HULL PENETRATIONS,1 IN #3 COMPT PORT SIDE AND 1 IN #5 COMPT PORT SIDE.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Accommodation/Occupational Safety
Issued 17 March 1992
Resolved
REMOVE OR REPAIR LEAKING PIPE IN #5 COMPT, PORT SIDE.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Electrical
Issued 17 March 1992
Resolved
LABEL CIRCIUTS IN SWITCH PANEL "C".
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Construction/Loadline
Issued 17 March 1992
Resolved
INSTALL PIPE PLUGS IN UNUSED WIRE WAY PENETRATIONS THROUGH BULKHEADS: #3 COMPT FWD BULKHEAD (1), #4 COMPT AFT BULKHEAD (1), AND #6 COMPT NEAR LADDER (1).
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Electrical
Issued 17 March 1992
Resolved
CONNECT OR PROPERLY TERMINATE LOOSE WIRES INSIDE PILOT HOUSE CONTROL CONSOLE.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Lifesaving
Issued 17 March 1992
Resolved
NUMBER OF ADULT PASSENGERS ALLOWED ON BOARD IS REDUCED TO 499 UNTIL 1 ADDITIONAL ADULT SIZE LIFE PRESERVER IS PROVIDED ON BOARD.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Lifesaving
Issued 17 March 1992
Resolved
POST EMERGENCY CHECK OFF LIST ON MAIN DECK AND TENNESSEE DECK (01 DECK) SO AS TO BE VISIBLE TO CREW AND PASSENGERS.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Unknown
Issued 30 June 1987
Resolved
LEAK IN FUEL LINE THREADED JOINTS FILL SIDE OF TANK
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Electrical
Issued 30 June 1987
Resolved
EMERGENCY LIGHTS ON PORT AND STB STAIRWAT TO SECOND DECK FAILED DURING TEST
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
IMPROPERLY MARKED LIFE PRESERVER STOWAGE
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Unknown
Issued 30 June 1987
Resolved
IMPROPERLY MARKED FUEL REMOTE SHUTOFF
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987