13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2025
Resolved
Must check the settings of the safety or relief valves on all pressure vessels, twice every 5 years. No more than 3 years.
Relief valve on pressure vessel has no evidence or documentation of testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 30 December 2025
Resolution: Forest Urick submitted photos of installation of new relief valve for the proper PSI and CFM.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 December 2025
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type. A space containing propulsion machinery.
Operator provided inspection results indicating horn strobe inside battery room is functional audibly but not visually.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 30 December 2025
Resolution: Forest Urick provided video of audible and visual alarm system for battery room.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 December 2025
Resolved
Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered automatically operated lights.
Batteries in 05 emergency lights were discharged.
46 CFR 184.30-5(b)
(OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 December 2025
Resolved 30 December 2025
Resolution: Photos provided for new installation of 05 emergency lights.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 February 2025
Resolved
All agreements and arrangements, written or unwritten, between and among employers and service agents concerning the implementation of DOT drug testing requirements are deemed, as a matter of law, to require compliance with all applicable provisions of this part and DOT drug testing regulations. Compliance with these provisions is a material term of all such agreements and arrangements. 46 CFR 16.203(a)(3)
DAPI consortium enrollment expired December 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: Received letter from CHECKR indicating that Aramark - Fort Sumter Touors - is an active member of the USCG drug and alcohol testing program. Valid until 31DEC2025.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 February 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard Light List. Extracts from the publication may be provided instead of the complete publication. 46 CFR 121.420(a)
Vessel was not equipped with an up-to-date light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: Vessel's rep provided photographic evidence that extracts from the Light List and Coast Pilot are current.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2025
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 164.018 in subchapter Q of this chapter. 46 CFR 122.604(i)
Retro-reflective material on all ring life buoys found to be excessively degraded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Retro-reflective material refreshed on all liferings.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 February 2025
Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. 46 CFR 121.502
Call sign on the Safety Radiotelephony Certificate and the Bridge-to-Bridge Radiotelephony Certificate do not match with the FCC Station License.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2025
Resolution: Vessel provided Inspectors with copies of the updated Safety Radiotelephony and the Bridge-to-bridge Radiotelephony Certificates.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 10 February 2025
Resolved
A self-propelled vessel of 65 feet or more in commercial service, must have on board a properly installed, operational Coast Guard type-approved AIS Class A device. 33 CFR 164.46(b)
AIS broadcasting incorrect call sign and vessel type.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 February 2025
Resolution: Verified that company updated AIS info with NAVCEN.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 February 2025
Resolved
The emergency lighting must automatically actuate upon failure of the main lighting system. 46 CFR 120.432(b)
Emergency light on the port side bulkhead of the engine room at the base of the stairs was energized while power was on to the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Malfunctioning emergency light replaced.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 10 February 2025
Resolved
A-Class bulkheads must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test the average temperature on the unexposed side does not rise more than 250 degrees F. 46 CFR 116.415(a)(2)(i)
The A-60 insulation was not present around the watertight door between the machinery space and the battery room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: A-60 insulation replaced around watertight door beetween the machinery space and the battery room.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 46 CFR 117.71(a)
5 life jackets found damaged. Passenger maximum is reduced to 520 until replacement life jackets are put into service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Replaced the 5 damaged life vests.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025
Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. 46 CFR 120.220(a)
Main engine emergency shutdown panel not fastened to console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 24 February 2025
Resolution: ESD panel in wheelhouse has been properly secured.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2025
Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers. 46 CFR 116.800(a)
Materials used to replace the generator need to be removed from the vessel prior to carrying passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 February 2025
Resolved 12 February 2025
Resolution: Crew removed the materials used to replace the generator from the vessel.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 19 September 2023
Resolved
A manned oceangoing ship of 40 feet or more in length that is documented under the laws of the United States or numbered by a state and that either is engaged in commerce or is equipped with a galley and berthing requires a Garbage Management Plan. Vessel missing Garbage Management Plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2023
Resolved 20 November 2023
Resolution: A waste management plan was placed on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 19 September 2023
Resolved
The fire control plan must show escape routes, areas of refuge, embarkation stations, the location of fire protection/emergency equipment, compartment titles and hazard classification of accommodation and service spaces, and structural fire protection boundaries. The fire control plan was missing areas of refuge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 20 November 2023
Resolution: Areas of safe refuge were highlighted on the Fire Control Plan.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 September 2023
Resolved
Tests must verify that automated vital systems are designed, constructed, and operate in accordance with all applicable requirements of part 62 of this sub chapter. Subsequent Automation Testing should be in accordance with the MSC approved DVTP at the discretion of the attending marine inspector for cause and at least once every 5 years IAW CG CVC Policy Letter 17-07. Vessel has not completed design verification test procedures and scheduled to complete them on 16NOV2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2023
Resolved 20 November 2023
Resolution: Observed satisfactory test of the PSTPs for the vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 June 2023
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant [name withheld] doors and hatch from battery room not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 26 June 2023
Resolution: installed signs in the appropriate places
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 November 2022
Resolved
A space containing propulsion machinery must be equipped with a fire detection and alarm system of an approved type. The fire detection system in the battery room was not functioning as designed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2022
Resolved 15 November 2022
Resolution: Vessel operator provided documentation of servicing of the smoke detection system. Deficiency rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 November 2022
Resolved
A suitable hull strainer must be installed in the circulating raw water intake line of an engine cooling water system. The strainer and associated piping used for cooling the battery installation is leaking. Deficiency to be rectified within 7 days.
Action required: 705 - Other - as specified
Due 21 November 2022
Resolved 28 November 2022
Resolution: Vessel operator provided photograph of satisfactorily replaced piping to the strainer. Deficiency rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 November 2022
Resolved
Each life jacket mist be marked with Type I retroreflective material. 09 child life jackets and 01 adult life jacket are in need of retroreflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 November 2022
Resolved 16 November 2022
Resolution: Vessel operator provided documentation of retroreflective tape replaced on life jackets. Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 November 2022
Resolved
A door in stair-tower, stairway, and man vertical zone bulkhead must be of the self-closing type capable of closing against a 3.5 list of the vessel. The fire door to the engine room could not close as designed. Deficiency rectified at next drydock.
Action required: 705 - Other - as specified
Due 31 January 2023
Resolved 10 February 2025
Resolution: Inspectors checked the function of the self-closing doors in both stairways entering the machinery space and found both to be functioning as required.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 16 November 2021
Resolved
Except when operating on lakes, bays, and sounds, or river routes in calm weather, all hatches and openings in the hull, except loading doors, of a vessel must be kept tightly closed except when being used. Watertight door from battery room to engine room did not have all points of contact when dogged down.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2022
Resolved 5 January 2022
Resolution: Video Submitted showing full contact chalk test, and paper failing to be slipped through on water tight door dogs.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 November 2021
Resolved
A door in a bulkhead required to be A-60, A-30, or A-15 Class must be of hollow steel or equivalent material construction, solidly filled with approved structural insulation, and capable of meeting the requirements of an A-15 Class bulkhead. Starboard door leading to engine room was missing sufficient insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted images of door being repaired.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 November 2021
Resolved
Vessel must follow approved structural fire protection detailed plans. Vessel's battery room hatch was missing adequate structural fire protection insulation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted media of def rectified.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 November 2021
Resolved
The minimum capacity of the power pump shall be 50 gallons per minute at a pressure of not less than 60psi. During test of fire pump, gauge read 50psi.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted video of fire pump operating and reading 60psi at the guage.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2021
Resolved
All wiring shall be run as high as practicable above bilges. Wires hanging from ceiling 3ft from bilge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 4 April 2022
Resolution: Vessel rep submitted image of wires being secured.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2021
Resolved
Wire joints and splices shall be mechanically secure and in junction boxes. Vessel security camera cable is splices and bundled with duct tape loosely hanging in engine room.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2021
Resolved
The number and identification of items stowed inside must be clearly marked on each container. Adult and child life jacket totals were mislabeled on container.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2021
Resolved
An adult lifejacket must be provided for each person carried on board a vessel. 02 adult lifejackets were taken out of service. Vessel restricted to 543 adults total until 02 adult lifejackets added onboard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 November 2021
Resolved
Each lifejacket carried on board must be marked in accordance with 46CFR122.604. Ensure all lifejackets are clearly labeled with vessel name.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 November 2021
Resolved
All electrical installations shall be to the satisfaction of the OCMI. Vessel had inoperable lighting in the lifejacket stowage closet on the main deck, as well as in the battery room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2022
Resolved 19 January 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 March 2021
Resolved
A power driven vessel underway shall exhibit a masthead light forward, a second masthead light abaft of and higher than the forward one, sidelights, and a sternlight.
Starboard running light and sternlight were non-operational.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 March 2021
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 March 2021
Resolved
A door in a bulkhead required to be A-0 Class must be of solid or hollow steel or equivalent material construction, and capable of meeting the requirements of an A-0 Class bulkhead.
A-0 door to the machinery space must be self-closing.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, heat resistivity as that afforded by the hull may be approved. Hole in bilge piping needs to be repaired. Prove proper operation to the Marine Inspector. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 31 December 2019
Resolved 13 December 2019
Resolution: Bilge piping was replaced and function test was conducted with satisfactory results.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
All unfired pressure vessels must be installed to the satisfaction of the cognizant [name withheld] manufacturers data report for pressure tank (air receiver) in engine room needs to be provided to USCG. 46 CFR 119.330
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2019
Resolved 31 January 2020
Resolution: Recieved U-1A for new pressure vessel. see vessel documents
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
This part is intended to provide a minimum standard of
regulations for electrical installations and equipment
that will result in a vessel that is reasonably safe
from fire caused by and/or originating in electrical
equipment. Provide a light switch cover plate in
scullery. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Cover plate was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Lighting in holds needs to be in working condition. 46 CFR 183.01-15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: All lighting was repaired in the hold spaces.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 December 2019
Resolved
Vessel required to have bilge high level alarm. Bilge high level alarm probe needs to be mounted. 46 CFR 119.530
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Bilge high level was secured to framing in the bilge.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 December 2019
Resolved
The Rules concerning shapes shall be complied with by day. Day shapes required onboard vessel (three black balls).
33 CFR 83.20(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Day shapes were place inservice
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 December 2019
Resolved
A vessel must carry adequate and up-to-date charts and nautical publications. The following need to be updated to newest version: Charts, U.S. Coast Pilot [name withheld] List, , Inland Navigation Rules. 46 CFR 121.420
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: Charts, U.S. Coast Pilot [name withheld] List, Inland Navigation Rules were updated.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
The materials and construction of fuel lines must comply with the requirements of tis paragraph. Remove hose from fuel stripping line and place plug in valve. 46 CFR 119.455
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: hose from fuel stripping line removed and plug placed in valve.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
The intent of this part is to insure the main propulsion machinery is suitable for the vessel and its operation. Need bolts for the glycol and seawater pump mounts are missing/broken. 46 CFR 182.01-5
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 13 February 2020
Resolution: bolts for the glycol and seawater pump mounts are installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 December 2019
Resolved
Have vessel ready for inspections of hull structure and its appurtenances, including inspection of all accessible parts of the exterior and interior of the hull. Fixed ballast in forward peak has four broken welds fix during next dry-dock. 46 CFR 115.802
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 7 April 2022
Resolution: Resolved during the same activity during follow up.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 November 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Required to have 545 adult life jackets, 31 have been taken out of service or need new retro reflective tape. Restricted to 514 passengers onboard until the 31 missing lifejackets are onboard. 46 CFR 117.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2020
Resolved 13 February 2020
Resolution: 31 life jackets were placed inservice onboard the vessel bringing life jacket count to required 545.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2019
Resolved
Propulsion machinery shall be suitable in type and design for prpulsion requirements.
Vessel had failures in cooling water system required by the hybrid propulsion system.
Repair and conduct satisfactory sea trail.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2019
Resolution: Conducted satisfactory repairs by installing dedicated motor controllers for each of the cooling water pumps of the hybrid propulsion system with satisfactory sea trail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 August 2019
Resolved
Installation of propulsion machinery of an unusual type for small passenger vessel must be given seperate consideration.
Resubmit to MSC affacted dwg by the modifications made to the system not limited to one line block, qualitative failure anylysis, and periodic safety procedures.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2019
Resolved 1 October 2019
Resolution: Recieved notification that m/v THE SPIRIT OF THE LOW COUNTRY, O.N. 699243, Serodino Hull No 62, P013740 was submitted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2018
Resolved
Vessel missing 5 lifejackets, restricted to 522 pax until new lifejackets are onboard.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 14 November 2019
Resolution: Replaced life jackets
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2018
Resolved
Vessel battery bank throwing voltage fault, vessel restricted to running diesal electric until technician arrives and corrects issue. Crash test and battery propulsion mode to be tested in presence of marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 1 October 2018
Resolved
Emergency instruction list missing info on fires in battery room. Vessel to update and post.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 14 November 2019
Resolution: Posted instructions
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 October 2018
Resolved
Fire extinguisher in galley missing bracket. Replace/repair to satisfaction of USCG.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 16 October 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2018
Resolved
Vessel replaced pressure tank (air reciever) in engine room. ASME manufacturers data report to be provided to USCG.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 October 2018
Resolved 13 February 2020
Construction/Loadline › Structures › Deck Plating
Issued 17 March 2017
Resolved
C/R area in steering space aft riser to remove pitting on existing weld seam. Clad welded as temp repair during March 2017 dry dock.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 14 November 2019
Resolution: Verified insert was conducted to close outstanding deficiency
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 15 November 2016
Resolved
Clean Port/Stbd genset armatures
Due 15 December 2016
Resolved 30 November 2016
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 November 2016
Resolved
Clean corrosion off battery cables.
Due 15 December 2016
Resolved 30 November 2016
Engineering › Fuel Oil Service System › Filter
Issued 15 November 2016
Resolved
Remove excess oil from Racor filter bowl on Stbd genset.
Due 15 December 2016
Resolved 30 November 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 November 2016
Resolved
Replace emergency light on 01 deck.
Due 15 December 2016
Resolved 30 November 2016
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 November 2016
Resolved
Renew injection T bar for cooling injection on port shaft dripless cutleass bearing & make vessel available for MOB drills.
Due 30 November 2016
Resolved 30 November 2016