Records from 1985 to 2005. Most recent: inspection, 28 January 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
28 January 2005
Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2282758
1 December 2004
ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2249157
7 September 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1672239
7 September 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1672600
30 April 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 289213
3 July 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 279423
19 February 1999
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 425775
2 April 1996
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 389463
26 March 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 488166
4 March 1994
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 364845
14 March 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 349437
3 February 1991
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 341699
30 August 1990
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 490613
5 February 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 335185
28 March 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 329416
13 October 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 326263
2 July 1986
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 310058
18 August 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 303669
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 1 December 2004
Resolved
Provide mechanical means of closure for discharge containment.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 23 May 2009
Resolved 23 May 2009
Resolution: Mechanical means for closure of containment was verified.
Lifesaving
Issued 3 July 2000
Resolved
Starboard lifeboat forward davit would not release. Davit arm hanging up and catching on roller guide. Class to attend and observe the lowering/release and stowing of both life boats and submit written report to USCG.
Condition: Unknown
Due 4 July 2000
Resolved 7 July 2000
Electrical
Issued 3 July 2000
Resolved
Emergency Generator would not start.
Condition: Unknown
Due 4 July 2000
Resolved 3 July 2000
Fire Fighting
Issued 3 July 2000
Resolved
Fire Hydrant #8 on main deck unable to close. Hydrant spraying when charged. Class to attend and submit written report to USCG.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 3 July 2000
Resolved
Windows on lifeboats are covered with cement dust. Unable to see out of windows. Wipers broken on both port and starboard lifeboats.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Accommodation/Occupational Safety
Issued 3 July 2000
Resolved
Doors to Bosn stores will not close. Class to attend and submit written report to USCG.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Fire Fighting
Issued 3 July 2000
Resolved
Fire Station #2 on main deck blocked with sand blasting equipment.
Condition: Unknown
Due 4 July 2000
Resolved 3 July 2000
Lifesaving
Issued 3 July 2000
Resolved
STARBOARD LIFE BOAT EMBARKATION LADDER HAND RAILS WASTED. CLASS TO ATTEND AND SUBMIT WRITTEN REPORT TO USCG.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 3 July 2000
Resolved
Starboard Lifeboat rollers not greased. Forward davit failed to move when released.
Condition: Unknown
Due 3 August 2000
Resolved 7 July 2000
Navigation
Issued 19 February 1999
Resolved
FOUND EXCESSIVE HYDRAULIC OIL LEAKAGE IN THE STEERING SYSTEM. DNV CLASS REPORT REQUIRED BEFORE DEPARTURE. _x001C_ _x001C_ 20FEB99, RCVD CLASS REPORT
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Unknown
Issued 4 March 1994
Resolved
A VIO OF 33 C.F.R. 155.730 IN THAT THE VESSEL'S PERSONNEL WERE NOT IN COMPLIANCE WITH THEIR OWN TRANSFER PROCEDURES DUE TO THE SECOND AND THIRD ENGINEERS BEING IN THE RACK AT THE TIME OF THE TRANSFER.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Unknown
Issued 4 March 1994
Resolved
A VIO OF 33 C.F.R. 156.160 IN THAT THE PERSON IN CHARGE OF TRANSFER OPERATIONS, WAS NOT AT THE SITE OF THE TRANSFER DURING A TRANSFER.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994
Documentation
Issued 3 February 1991
Resolved
EACH OPERATION WAS NOT SIGNED BY PERSON IN CHARGE IN OIL RECORED BOOK,_x001C_ VIOLATION OF 33 CFR 151.25(h)
Condition: Unknown
Due 3 February 1991
Resolved 3 February 1991
Navigation
Issued 18 August 1985
Resolved
VESSEL FAILED TO CONDUCT OR LOG EMERGENCY EQUIPMENT TESTS AS REQUIRED.
Condition: Unknown
Due 28 March 1989
Resolved 18 August 1985
Navigation
Issued 18 August 1985
Resolved
VESSEL HAD ON BOARD COAST PILOT #7, 1984 ISSUE, WITH NO CORRECTIONS,AND 1984 LIGHT LIST VOL. III WITH NO CORRECTIONS.
Condition: Unknown
Due 18 August 1985
Resolved 18 August 1985
Accommodation/Occupational Safety
Issued 18 August 1985
Resolved
VESSEL HAS INSTALLED TOILET FACILITIES WITH A TYPE II MARINE SANITATION DEVICE. THE UNIT WAS TURNED OFF AND THE VALVES WERE ALIGNED TO ALLOW RAW SEWAGE TO BE DISCHARGED INTO U.S. WATERS.
Condition: Unknown
Due 18 August 1985
Resolved 18 August 1985