Records from 1986 to 2026. Most recent: inspection, 28 July 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 62
28 July 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8448711
6 July 2026
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8430638
27 June 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8172875
31 January 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8072744
15 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8063995
24 June 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7941365
19 May 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7699668
9 January 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7618549
15 August 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7534063
24 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7234858
19 February 2021
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7143095
28 January 2021
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7132617
22 January 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7131974
18 June 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6980271
29 May 2020
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6963484
17 April 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6667773
23 January 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6615765
18 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6395410
24 July 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6219389
16 May 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6206742
24 January 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6076888
18 October 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6025475
16 March 2016
DAPI Audit · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5834609
6 June 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4882834
15 November 2010
Deficiency Check · Hull Examination · Simplified Stability Test · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3959000
27 July 2009
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3548292
27 March 2009
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3493075
19 June 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3240688
23 April 2007
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2913410
20 March 2007
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2888292
12 February 2007
Drydock Extension
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 2870994
5 June 2006
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2671044
24 March 2006
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2591371
8 April 2005
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2329104
18 March 2005
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2361242
9 April 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2040885
27 March 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1763642
19 February 2003
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1746721
19 April 2002
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1606626
20 March 2002
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1494934
28 June 2001
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469695
26 March 2001
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1370069
30 March 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1426352
8 March 2000
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469614
7 April 1999
Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1467137
9 April 1998
Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1441359
3 April 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1466456
19 March 1996
Hull Examination · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1404097
20 March 1995
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417757
31 March 1994
Re-Inspection · Hull Examination · Inclining Experiment
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1379953
23 March 1993
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1149629
2 March 1992
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 945138
12 November 1991
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 935195
8 April 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 928275
26 March 1991
Re-Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 924367
10 April 1990
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1239634
8 March 1990
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1213424
23 February 1989
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1197083
4 March 1988
Re-Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1337295
26 January 1988
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1016833
6 May 1987
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1326927
10 July 1986
Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 998894
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 July 2026
Resolved
Oceans, coastwise, limited coastwise, and Great Lakes routes. A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—(1) Six hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.121; and(2) Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Only three red flares were on board.
46CFR180.68
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2026
Resolution: Received photo of all flares. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 July 2026
Resolved
A hatch exposed to the weather must be watertight, except that the following hatches may be weathertight.
Cabin hatch has no securing device.
46CFR179.360
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2026
Resolution: Received photo of hatch being ablbe to be secured.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 6 July 2026
No resolution recorded
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. EPIRB battery, hydrostatic release, and registration were expired. Vessel is restricted to Lakes, Bays, and Sounds route.
46CFR176.808(b)
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 6 July 2026
No resolution recorded
Each EPIRB, other than an EPIRB in an inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. No record of monthly test on board.
46CFR185.728
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 6 July 2026
No resolution recorded
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. No FCC Safety Radiotelephony certificate on board.
Action required: 16 - Rectify deficiencies w/in 14 days
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 July 2026
No resolution recorded
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. MMSI number is not programmed into VHF radio.
46CFR184.502
Action required: 16 - Rectify deficiencies w/in 14 days
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 July 2026
No resolution recorded
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List,U.S. Coast Pilot or similar publication. Coast pilot and Light List were out of date (2023).
46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 July 2026
No resolution recorded
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retro reflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). No retro reflective tape was on life ring buoy.
46CFR185.604
Action required: 10 - Deficiency Rectified
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 July 2026
No resolution recorded
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Life float retro reflective tape is deteriorated and in need of replacement.
46CFR185.604
Action required: 10 - Deficiency Rectified
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 27 June 2025
Resolved
Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under § 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel has an expired COD
46CFR 67.7
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Vessel has current COD.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 June 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. FCC Safety Cert is expired.
47CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2025
Resolution: Vessel currently has the FCC safety cert onboard.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 27 June 2025
Resolved
Copies of the test report and test data obtained from the test facility recognized by the U.S. Coast Guard showing that the radiobeacon complies with the U.S. Coast Guard environmental and operational characteristics associated with the measurement methods described in Appendix A of the RTCM Recommended Standards. Expired EPIRB registration.
47CFR 80.1061 (c)(1)(iii)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: EPIRB registration was verified as current.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 June 2025
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. STBD side shaft packing has excessive leaking.
46CFR 182.200(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: STBD shaft packing was tightened. No further excessive leaking was found.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 June 2025
Resolved
Components are listed by an independent, nationally recognized testing laboratory as set forth in 29 CFR 1910.7, and are designed, installed, tested, and maintained in accordance with an appropriate industry standard and the manufacturer's specific guidance. FF reinspection was expired.
46CFR 181.120(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: All FF systems were serviced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2023
Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
Batteries in the floating waterlights for the lifefloat and ring buoy were expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 24 June 2024
Resolution: Item was satisfactory to the attending CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2023
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150.
Grabline on ring buoy was wasted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 24 June 2024
Resolution: Item was satisfactory to the attending CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 19 May 2023
Resolved
The breaking strength of each link must be between 200 lb. and 268 lb. for links intended for life floats and buoyant apparatus of 11 to 20 persons capacity.
Vessels weak link was missing manufacturers tag. Replace weak link with appropriate size link for life float.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2023
Resolved 24 June 2024
Resolution: Item was satisfactory to the attending CG Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 August 2022
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident shall comply with the requirements of §4.06 in subchapter A of this chapter.
Vessel's alcohol test strips were out of date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 24 October 2022
Resolution: Added new Test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 August 2022
Resolved
The color of the buoyant apparatus must be primarily vivid reddish orange as defined by sections 13 and 14 of FED-STD-595C. The color of the life float was extremely faded. Operator needs to repaint or replace life float prior to the beginning of cold water timeframe (Nov 01).
46CFR 160.010-4(n)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2022
Resolution: Life float was repainted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2021
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident shall comply with the requirements of §4.06 in subchapter A of this chapter.
Vessel's alcohol test strips were out of date.
46 CFR 185.212
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2021
Resolved 7 July 2021
Resolution: Received photos of new test strips.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 June 2020
Resolved
Fuel shut off valve was not labeled upon inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 24 June 2020
Resolution: Fuel shut off properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 June 2020
Resolved
No emergency instructions posted upon inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 24 June 2020
Resolution: Emergency instructions posted.
Communications › Radio Communications › EPIRB
Issued 16 May 2017
Resolved
Replace EPIRB battery prior to sailing limited coastwise.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 13 July 2017
Resolution: EPRIB battery was replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 16 May 2017
Resolved
Replace expired batteries.
Action required: 705 - Other - as specified
Due 30 May 2017
Resolved 1 June 2017
Resolution: Batteries were replaced.
Lifesaving › Hand Flares › Quantity
Issued 16 March 2016
Resolved
Vessel has Limited Coastwise Route which requires 6 Red and 6 Orange flares. On board are 4 Red and 3 Orange. Replace missing flares 02 Red 03 Orange for a total of 12.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2016
Resolved 18 October 2016
Resolution: Vessel owner provided proof of 6 red and 6 orange flares, ALL SAT.
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 March 2016
Resolved
Bilge indicator Forward compartment not operating in auto mode. Repair/Replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2016
Resolved 18 October 2016
Resolution: Vessel owner provided proof of fully operational bilge indicator (operating in the auto-mode) for the Forward Compartment, ALL SAT.
Lifesaving › Lifebuoys › Serviceable
Issued 16 March 2016
Resolved
Grab lines on Life ring buoy wasted. Life ring also needs servicing. Repair/Replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2016
Resolved 26 March 2016
Resolution: Vessel owner provide proof of new Life Ring - ALL SAT.
Engineering › Fuel Oil Service System › Valve, Control
Issued 16 March 2016
Resolved
Re-stencil "Emergency fuel shut-off".
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 March 2016
Resolved 26 March 2016
Resolution: Vessel owner proof of restenciling of "Emergency Fuel Shut-Off" for the emergency fuel shut-off valves - ALL SAT.
Lifesaving › Lifefloat › Retroreflective Material
Issued 15 November 2010
Resolved
Reflective tape on life float wasted, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Reflective tape on life float replaced with new reflective tape.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 15 November 2010
Resolved
Reflective tape on 2 children life jackets wasted, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Children''s life jackets replaced as new.
Construction/Loadline › Penetrations › Gasket
Issued 15 November 2010
Resolved
Penetrations in forward watertight bulkhead holed, make watertight as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Penetrations in forward watertight bulkhead sealed to the satisfaction of the CG Marine Inspector.
Engineering › Bilge Water Management System › Pump
Issued 15 November 2010
Resolved
Hand held bilge pump missing, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: New hand held bilge pump purchased and maintained o/b the vessel.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 November 2010
Resolved
Copy of mates drug consortium enrollment card missing, provide as required.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Copy of mate''s drug consortium card provided to the CG Marine Inspectors.
Stability › Watertight Integrity › General
Issued 15 November 2010
Resolved
Bridge windows broken and in disrepair. Replace as new with safety glass to the satisfaction of the CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: Bridge windows replaced with safety glass to the satisfaction of the CG marine inspectors.
Communications › Radio Communications › EPIRB
Issued 15 November 2010
Resolved
EPIRB missing from vessel, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2011
Resolution: EPIRB replaced & registered to the satisfaction of the CG Marine Inspectors.
Communications › Radio Communications › EPIRB
Issued 27 July 2009
Resolved
Provide servicing documentation for the EPIRB hydrostatic release.
Action required: 705 - Other - as specified
Due 14 August 2009
Resolved 10 August 2009
Resolution: Master provided servicing documentation for the EPIRB hydrostatic release, which has been completed with the past two years.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2009
Resolved
First aid kit onboard contained expired items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 August 2009
Resolved 10 August 2009
Resolution: Master updated the first aid kit onboard with new USCG approved kit IAW 46CFR184.710.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 19 June 2008
Resolved
Fixed Halon fire system overdue for inspection and owner needs to provide proof of fire system by a qualified servicing facility.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2008
Resolved 20 June 2008
Resolution: Owner faxed copy of servicing report by servicing facility.
Engineering › Fuel Oil Service System › Piping
Issued 19 June 2008
Resolved
Fuel Vent Piping is wasted and requires replacement both port and starboard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 17 July 2008
Resolution: Removed and replaced both port and starboard fuel vent pipes.
Engineering › Fuel Oil Service System › Filter
Issued 23 April 2007
Resolved
Install flame impingement bowl on port racor fuel filter.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 3 May 2007
Resolution: Flame impingement bowl installed on fuel filter housing.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 April 2007
Resolved
Provide current Certificate of Documentation for vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 3 May 2007
Resolution: Current Certificate of Documentation provided for vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 23 April 2007
Resolved
Install 60ft lifeline on lifebuoy IAW 46 cfr 180.70. Prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 3 May 2007
Resolution: Proper lifeline installed on lifebuoy.
Construction/Loadline › Hull › Stiffener
Issued 23 April 2007
Resolved
Repair damaged stiffener in engineroom near the stbd shaft.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 3 May 2007
Resolution: Damaged stiffener has been repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 23 April 2007
Resolved
Install audible and visual high level bilge alarm at operating station. Prior to carriage of passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 3 May 2007
Resolution: Audible and visual alarm for high bilge level installed. Alarm tested in the presence of Marine Inspector.
Lifesaving › Lifefloat › Serviceable
Issued 24 March 2006
Resolved
Repair exterior surface of 15 man lifefloat IAW 46 CFR 160.010-4(n). 30 days to correct deficiency.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 April 2006
Resolved 5 June 2006
Resolution: New 15 man lifefloat installed on vessel.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 April 2005
Resolved
Removal of shore tie left a 2" hole in portside aft transverse bulkhead above engine compartment.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 April 2005
Resolved 18 May 2005
Resolution: [name withheld] provide photographic proof of repair.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 April 2005
Resolved
Five adult and one child lifejacket were not serviceable. Vessel is limited to twenty-five passengers (no more than two children) until replacement of required lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 18 May 2005
Resolution: [name withheld] provided a reciept for 6 new life jackets (4 adult and 2 child) dated 21 April 2005.
Lifesaving
Issued 20 March 2002
Resolved
Provide proof of servicing EPIRB Hydrostatic release. Vessel restricted to operation not more than three miles from shore until item cleared. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 20 April 2002
Resolved 19 April 2002
Unknown
Issued 7 April 1999
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN IAW 33 CFR 151.57.
Condition: Unknown
Due 3 May 1999
Resolved 25 May 1999
Electrical
Issued 7 April 1999
Resolved
PROVIDE CORROSION RESISTANT TRAY OR BOX FOR 02 12V DC BATTERIES IAW 46 CFR 176.806.
Condition: Unknown
Due 3 May 1999
Resolved 25 May 1999
Navigation
Issued 7 April 1999
Resolved
REPAIR COMPASS LIGHT AS REQUIRED IAW 46 CFR 184.402.
Condition: Unknown
Due 3 May 1999
Resolved 25 May 1999
Accommodation/Occupational Safety
Issued 7 April 1999
Resolved
REPAIR OR REPLACE 03 AFT BRIDGE WINDOWS (RESTRICTED VISIBILITY) IAW 46 CFR 177.1030.
Condition: Unknown
Due 3 May 1999
Resolved 25 May 1999
Lifesaving
Issued 7 April 1999
Resolved
PROVIDE PROOF THAT EPIRB HYDROSTATIC RELEASE IS WITHIN SERVICE DATE OR REPLACE.
Condition: Unknown
Due 3 May 1999
Resolved 25 May 1999
Engineering
Issued 26 March 1991
Resolved
REPLACE 2 HOSES TO WATER STRAINERS IN ENGINE ROOM.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Lifesaving
Issued 26 March 1991
Resolved
STORE CHILDRENS LIFE PRESERVERS SAPARATE FROM ADULT LIFE PRESERVERS.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 26 March 1991
Resolved
POST EMERGENCY CHECK OFF LIST IN MAIN CABIN.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Documentation
Issued 26 March 1991
Resolved
PROVE PROPER CALL SIGN ON RADIOTELEPHONY CERTIFICATE AND RADIO STATION LICENSE BY COMPLETION OF NEXT FCC INSPECTION.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Engineering
Issued 26 March 1991
Resolved
REPLACE 2 OIL HOSES TO GEAR OIL COOLER.
Condition: Unknown
Due 26 March 1991
Resolved 26 March 1991
Unknown
Issued 23 February 1989
Resolved
PROVE THAT FOAM LINING IN THE ENGINEROOM IS FIRE RETARDANT.
Condition: Unknown
Due 23 February 1989
Resolved 23 February 1989
Electrical
Issued 23 February 1989
Resolved
PLACE 2 ADDED BATTERIES IN LINED BATTERY BOXES.
Condition: Unknown
Due 23 February 1989
Resolved 23 February 1989