MAURY USCG vessel records
← All vessels

ST MARYS CEMENT

ST MARYS CEMENT is a 1986 freight barge. The Coast Guard has recorded 44 inspections since 1986, most recently in November 2016, along with 24 deficiencies.

Records from 1986 to 2016. Most recent: inspection, 6 November 2016.

Built
1986
Last inspected
6 November 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 6 November 2016
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 20 calendar years (1986–2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8972077
270731
Flag
UNITED STATES
Maury page id
psix-270731

Documentation record

Tonnage as PSIX records it4679 - Simplified, Gross Ton
2024 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 4

Inspection history · 44

6 November 2016 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6043248
24 September 2015 Type not recorded
No type recorded · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5737090
24 June 2011 In-Service Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 4060665
23 June 2011 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 4054330
10 November 2002 Damage Survey
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1688486
24 April 2001 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 135364
31 August 2000 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 822157
17 July 2000 Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1051588
11 July 2000 Administrative
Administrative · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1051569
7 July 2000 Type not recorded
No type recorded · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 2540
8 May 2000 Damage Survey
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 818284
4 May 2000 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 39081
3 March 2000 COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 817602
16 July 1999 Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1100433
11 March 1999 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 787350
3 July 1998 Examination of Repairs · Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1128075
1 July 1998 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1130304
6 March 1998 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 786815
26 March 1997 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1095764
13 August 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 91973
29 April 1996 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1078804
15 March 1996 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1078141
12 June 1995 Damage Survey
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 880251
12 May 1995 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1192368
31 March 1995 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 154787
15 March 1995 Re-Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 846027
14 April 1994 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1167091
18 March 1994 COI Inspection
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 855467
30 April 1993 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 835380
6 November 1992 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1260373
21 March 1992 COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 961507
16 August 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1246317
17 June 1991 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1339641
28 May 1991 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1229938
18 March 1991 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1226344
25 May 1990 Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 931348
7 May 1990 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 909526
5 April 1990 COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 905531
17 August 1989 Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1196357
28 July 1989 Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1040335
28 June 1989 Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1039796
12 April 1988 COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1195534
26 August 1987 Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1030621
27 June 1986 Initial Certification
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1301826

Deficiency record · 24

Construction/Loadline
Issued 8 May 2000 Resolved
MAKE PERMANENT REPAIRS TO THE PORT QUARTER SIDE SHELL INWAY OF THE AFTER SPONSON VOID.
Condition: Unknown
Due 10 May 2000
Resolved 24 May 2000
Construction/Loadline › Hull › Bottom Plating
Issued 3 July 1998 Resolved
Make permanent repairs (crop & renew) holed shell plate in way of # 2 stbd ballast tank between frames 3 & 4 not later than 30APR99. _x001C_
Condition: Unknown
Due 31 May 2000
Resolved 7 March 2007
Resolution: Vessel changed flag and no longer operates in the US.
Construction/Loadline
Issued 1 July 1998 Resolved
Proceed immediately to Sturgeon Bay, WI for repairs to #2 starboard ballasttank. Contact Marine Safety Detachment Sturgeon Bay at [phone withheld] to arrange for a damage survey inspection upon arrival in Sturgeon Bay.
Condition: Unknown
Due 1 July 1998
Resolved 1 July 1998
Electrical
Issued 29 April 1996 Resolved
REMOVE AND INSTALL TYPE UL 508 MOTOR CONTROLLER FOR THE No.2 AND 3 BALLAST PUMPS. INSTALLATION SHALL COMPLY WITH 46 CFR 111.60-17 AND 46 CFR 111.70. THE CURRENTLY INSTALLED BALLAST PUMP (No.2 AND 3) MOTOR CONTROLLERS SHALL BE KEPT LOCKED TO PREVENT UNAUTHORIZED ENTRY.
Condition: Unknown
Due 29 April 1996
Resolved 4 June 1996
Accommodation/Occupational Safety
Issued 15 March 1996 Resolved
CORRECT THE PRESSURE RELIEF VALVE SETTING ON PRESSURE VESSEL No. W33261. ENSURE THAT THE RELIEF SETTING LIFTS PRIOR TO ATTAINING 99 PSI.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Lifesaving
Issued 15 March 1996 Resolved
STENCIL AND INSTALL USCG APPROVED PFD LIGHTS FOR ALL NEW EXPOSURE SUITS. ENSURE EXPOSURE SUITS ARE ACCESSIBLE FROM A SUITABLE LOCATION FOR EMERGENCYUSE.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 15 March 1996 Resolved
REPAIR THE LOOSE AND MISSING EXHAUST INSULATION ON THE 150 AND 1130 KW GENERATOR SET LOCATED IN THE MACHINERY RADIATOR SPACE.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Navigation
Issued 15 March 1996 Resolved
DEMONSTRATE DISCONNECTION OF THE BARGE FROM THE TUG AS PER G-MVI POLICY LETTER NO.06-93 OF 13APR93.
Condition: Unknown
Due 15 March 1996
Resolved 15 March 1996
Engineering
Issued 18 March 1994 Resolved
COMPLY WITH 33CFR155.720. VESSEL CARRIES OVER 250 BARRELS OF FUEL OIL, PROVIDE FUEL OIL TRANSFER PROCEDURES FOR COAST GUARD EXAMINATION.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Navigation
Issued 21 March 1992 Resolved
PROVIDE SOLAS APPROVED RUNNING LIGHTS.
Condition: Unknown
Due 21 March 1992
Resolved 21 March 1992
Construction/Loadline
Issued 28 May 1991 Resolved
Free up forepeak bilge suction valve and straighten reach rod.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Construction/Loadline
Issued 28 May 1991 Resolved
Prove satisfactory operation of bow thruster fuel tank reach rod.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Construction/Loadline
Issued 28 May 1991 Resolved
Free up all dogs on bow thruster water tight door.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Navigation
Issued 28 May 1991 Resolved
Provide satisfactory installation of remote switch on 01 deck to bow thruster space.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Construction/Loadline
Issued 28 May 1991 Resolved
stencil engineroom escapes on 01 deck.
Condition: Unknown
Due 28 May 1991
Resolved 28 May 1991
Engineering
Issued 5 April 1990 Resolved
CONDUCT A HYDROSTATIC TEST ON START AIR AND UNLOADING AIR RECEIVERS.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Fire Fighting
Issued 5 April 1990 Resolved
PROVIDE A COPY OF PORTABLE FIRE EXTINGUISHER SERVICING CERTIFICATE.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Lifesaving
Issued 5 April 1990 Resolved
STENCIL EMERGENCY ESCAPE.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Accommodation/Occupational Safety
Issued 28 July 1989 Resolved
INSTALL PROPER RELIEF VALVE ON AIR RECEIVER W33261.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Electrical
Issued 28 June 1989 Resolved
PROVE OPERATION OF ALL EMERGENCY LIGHTS.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Electrical
Issued 28 June 1989 Resolved
PROPERLY RUN WIRING TO AIR DRYER IN ENGINEROOM.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Engineering
Issued 28 June 1989 Resolved
REPAIR/REPLACE RELIEF VALVE ON AIR RECEIVER #W33261 AND PROVE OPERATION OF BOTH PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Fire Fighting
Issued 28 June 1989 Resolved
MOUNT FIRE AXE.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Construction/Loadline
Issued 28 June 1989 Resolved
FREE UP BALLAST TANK VENT COVERS.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989

Ownership record