Records from 2016 to 2026. Most recent: inspection, 15 April 2026.
Inspection history · 16
15 April 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8350719
2 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8104453
13 May 2024
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7911456
23 February 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7869107
11 January 2023
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7620062
9 May 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7446558
14 April 2022
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7430742
15 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7175569
15 May 2020
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6953883
23 January 2020
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6894411
17 January 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6611836
16 April 2018
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6475578
22 January 2018
Drydock Exam · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6341626
17 April 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6126034
14 April 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5853960
31 March 2016
Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5844202
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2026
No resolution recorded
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel with terms of its COI giving consideration to provision for a seaworthy hull and protection against fire. Vessel had no licensed master present, expired inspections on fire protection equipment, deterioration of decking. Inspection canceled. Vessel must undergo a satisfactory annual re-inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 February 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to the provisions for a seaworthy hull. Vessel sustained damage to port aft quarter IWO transom while in operation. Make repairs to the satisfaction of Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 February 2024
Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station. Alarm is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 January 2023
Resolved
Floating waterlight for life ring is not approved for inspected vessels. Provide approved floating waterlight for life ring. Route restricted to daylight only operations.
46 CFR 180.70(d)(1)
Action required: 705 - Other - as specified
Resolved 30 January 2023
Resolution: Approved light provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 May 2022
Resolved
Hole found in the hull laminate at the port quarter section of the vessel just above the waterline. Make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Repairs made SAT.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 May 2022
Resolved
Cracks found in the deck aft of engine compt. Make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Repairs made SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 May 2022
Resolved
Aft deck watertight hatch frame not attached to the deck due to unsecure hardware. Secure watertight hatch frame prior to credit dry-dock. 46 CFR 179.360
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Hatch secured SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2022
Resolved
40-B:C portable fire extinguisher in non-serviceable condition. Extinguisher to be replaced. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2022
Resolution: Extinguisher replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2021
Resolved
Man overboard drill conducted with master only. Master had some trouble with the drill. Drills to be conducted again to evaluate if master only operations should be revoked.
46 CFR 185.520
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Drill completed SAT. Pulley and sling assembly to be set up prior to getting underway.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2021
Resolved
Propulsion engine battery not protected from water or oil in the engine compartment. Battery to be free from exposure to water splash or spray. 46 CFR 183.350(b)
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Battery contained inside battery box.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2021
Resolved
Emergency instructions do not coincide with the actions taken by the master during emergency situations. Mount emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions.
46 CFR 185.510
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Emergency instructions SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2020
Resolved
Propeller requires repair or replacement due to excessive damage ath the ends of blades. Complete prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 20 May 2020
Resolution: Prop replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2020
Resolved
Propulsion shaft key-way to propeller key-way not aligned. Ensure that key is properly installed in key-way prior to credit dry-dock. 46 CFR 176.630
Action required: 705 - Other - as specified
Resolved 20 May 2020
Resolution: Key and shaft nuts replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 May 2020
Resolved
Excessive play found in rudder and rudder arm found loose. Ensure all steering components are installed and secured properly prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 20 May 2020
Resolution: Steering system SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 January 2019
Resolved
Prove proper operation of emergency fuel shut-off valve.
46 CFR 182.455(b)((4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2019
Resolution: Fuel valve operates properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 January 2019
Resolved
Provide pre-engineered fixed gas fire system servicing report. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2019
Resolution: Service report received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2019
Resolved
Label life jacket locations with amount and whether adult or child sized. 46 CFR 185.604
Action required: 705 - Other - as specified
Due 29 January 2019
Resolved 30 January 2019
Resolution: Life jacket locations labeled properly.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 January 2019
Resolved
Conduct drills quarterly and maintain dril log IAW regs.
46 CFR 185.420(c)
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 22 January 2019
Resolution: Conducted drills and log started.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2018
Resolved
Change out non approved wiring with approved boat cable as discussed with CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Owner replaced wiring with approved cable.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2018
Resolved
Prove proper operation of fire boy shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Proved proper operation of fireboy shutdown.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2018
Resolved
Provide annual servicing report for fire boy system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Provided current servicing report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2018
Resolved
Complete drills with CGMI>
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Completed drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2018
Resolved
Repair or replace dripless shaft seal. Got underway for drills and shaft seal was pouring water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2018
Resolved 6 August 2018
Resolution: Shaft seal replaced; test SAT.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 April 2017
Resolved
Provide log book for drills.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided log book for drills
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 April 2017
Resolved
Provide CG light list.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided CG light list.
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2017
Resolved
Provide chart of operating area.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided chart of operating area.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 April 2017
Resolved
Provide service report for fire extinguishers.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided service report.
Engineering › Steering Gear System › Rudder
Issued 14 April 2016
Resolved
Provide tiller for emergency steering.
Due 12 May 2016
Resolved 12 May 2016
Resolution: Emergency tiller provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016
Resolved
Update expired items in first aid kit.
Due 18 April 2016
Resolved 18 April 2016
Resolution: Expired items have been replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 April 2016
Resolved
Install retro tape on ring buoy.
Due 2 May 2016
Resolved 18 April 2016
Resolution: Tape has been placed on ring buoy.
Engineering › Lubricating Oil Service System › Hose
Issued 14 April 2016
Resolved
Replace broken hose clamp on oil cooler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Clamp has been renewed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 April 2016
Resolved
Conduct and provide current servicing report.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Service has been completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 April 2016
Resolved
Prove proper operation of fireboy shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Proved proper operation of fireboy shutdown.
Stability › Watertight Integrity › General
Issued 31 March 2016
Resolved
Install metallic plug in through hull fitting that is no longer being used.
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: Metallic plug has been installed.
Construction/Loadline › Hull › Side Shell
Issued 31 March 2016
Resolved
Submit repair plan to repair the FRP side shell that is loose IWO the side shell and cap.
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: Received repair plan.
Construction/Loadline › Hull › Side Shell
Issued 31 March 2016
Resolved
Repair dime size damage to FRP in stern, port side, 6" above the water line.
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: Repairs made by scarfing in new glass and epoxy resin.