MAURY USCG vessel records Sign in
← All vessels

HATTIE GALE

HATTIE GALE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1986, most recently in April 2026, along with 75 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1986 to 2026. Most recent: inspection, 15 April 2026.

Built
1986
Last inspected
15 April 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA9169
270735
Flag
UNITED STATES
—
Maury page id
psix-270735

Inspections, by type

…with no type recorded1
Years with a record 37 calendar years (1986–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it5 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 61

15 April 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8350719
2 April 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8104453
13 May 2024 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7911456
23 February 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7869107
11 January 2023 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7620062
9 May 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7446558
14 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7430742
15 April 2021 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7175569
15 May 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6953883
23 January 2020 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6894411
17 January 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6611836
16 April 2018 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6475578
22 January 2018 Drydock Exam · DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6341626
17 April 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6126034
14 April 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5853960
31 March 2016 Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5844202
15 February 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4244923
26 January 2012 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4232149
6 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4202496
1 August 2011 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4088443
25 February 2010 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3693804
23 July 2009 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3542307
15 February 2008 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3147933
30 January 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3138824
19 July 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3000219
20 October 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2518376
23 May 2005 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2365615
20 January 2004 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2007715
10 December 2003 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1961868
30 October 2002 COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1698521
30 July 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1654240
8 February 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1485043
30 October 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1075656
8 August 2001 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1451744
20 July 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1451577
10 February 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1472361
25 August 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1418587
21 August 1998 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798403
5 August 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 796650
26 February 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117304
24 September 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1409756
1 October 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1143789
20 August 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1087895
9 February 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186289
9 August 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 883036
26 September 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1172678
20 May 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 859852
12 October 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1145978
24 September 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940475
13 May 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 957853
3 October 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 936881
30 May 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 903060
10 October 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 907488
24 April 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1212549
2 October 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 959723
2 October 1989 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1326876
26 June 1989 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1342853
23 October 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889434
12 May 1988 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1350649
3 April 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1328611
26 June 1986 Credit Drydock · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990756

Deficiency record · 75

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 April 2026 No resolution recorded
46 CFR 177.100 The construction and arrangement of a vessel must allow the safe operation of the vessel with terms of its COI giving consideration to provision for a seaworthy hull and protection against fire. Vessel had no licensed master present, expired inspections on fire protection equipment, deterioration of decking. Inspection canceled. Vessel must undergo a satisfactory annual re-inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 February 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to the provisions for a seaworthy hull. Vessel sustained damage to port aft quarter IWO transom while in operation. Make repairs to the satisfaction of Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 February 2024 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station. Alarm is inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 January 2023 Resolved
Floating waterlight for life ring is not approved for inspected vessels. Provide approved floating waterlight for life ring. Route restricted to daylight only operations. 46 CFR 180.70(d)(1)
Action required: 705 - Other - as specified
Resolved 30 January 2023
Resolution: Approved light provided.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 25 May 2022 Resolved
Hole found in the hull laminate at the port quarter section of the vessel just above the waterline. Make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Repairs made SAT.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 May 2022 Resolved
Cracks found in the deck aft of engine compt. Make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Repairs made SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 25 May 2022 Resolved
Aft deck watertight hatch frame not attached to the deck due to unsecure hardware. Secure watertight hatch frame prior to credit dry-dock. 46 CFR 179.360
Action required: 705 - Other - as specified
Resolved 26 May 2022
Resolution: Hatch secured SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 April 2022 Resolved
40-B:C portable fire extinguisher in non-serviceable condition. Extinguisher to be replaced. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2022
Resolution: Extinguisher replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2021 Resolved
Man overboard drill conducted with master only. Master had some trouble with the drill. Drills to be conducted again to evaluate if master only operations should be revoked. 46 CFR 185.520
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Drill completed SAT. Pulley and sling assembly to be set up prior to getting underway.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2021 Resolved
Propulsion engine battery not protected from water or oil in the engine compartment. Battery to be free from exposure to water splash or spray. 46 CFR 183.350(b)
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Battery contained inside battery box.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 23 April 2021 Resolved
Emergency instructions do not coincide with the actions taken by the master during emergency situations. Mount emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. 46 CFR 185.510
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 28 April 2021
Resolution: Emergency instructions SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2020 Resolved
Propeller requires repair or replacement due to excessive damage ath the ends of blades. Complete prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 20 May 2020
Resolution: Prop replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2020 Resolved
Propulsion shaft key-way to propeller key-way not aligned. Ensure that key is properly installed in key-way prior to credit dry-dock. 46 CFR 176.630
Action required: 705 - Other - as specified
Resolved 20 May 2020
Resolution: Key and shaft nuts replaced.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 May 2020 Resolved
Excessive play found in rudder and rudder arm found loose. Ensure all steering components are installed and secured properly prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 20 May 2020
Resolution: Steering system SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 January 2019 Resolved
Prove proper operation of emergency fuel shut-off valve. 46 CFR 182.455(b)((4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2019
Resolution: Fuel valve operates properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 January 2019 Resolved
Provide pre-engineered fixed gas fire system servicing report. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 January 2019
Resolution: Service report received.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2019 Resolved
Label life jacket locations with amount and whether adult or child sized. 46 CFR 185.604
Action required: 705 - Other - as specified
Due 29 January 2019
Resolved 30 January 2019
Resolution: Life jacket locations labeled properly.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 22 January 2019 Resolved
Conduct drills quarterly and maintain dril log IAW regs. 46 CFR 185.420(c)
Action required: 10 - Deficiency Rectified
Due 23 January 2019
Resolved 22 January 2019
Resolution: Conducted drills and log started.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2018 Resolved
Change out non approved wiring with approved boat cable as discussed with CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Owner replaced wiring with approved cable.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2018 Resolved
Prove proper operation of fire boy shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Proved proper operation of fireboy shutdown.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 January 2018 Resolved
Provide annual servicing report for fire boy system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Provided current servicing report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2018 Resolved
Complete drills with CGMI>
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2018
Resolved 19 June 2018
Resolution: Completed drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 January 2018 Resolved
Repair or replace dripless shaft seal. Got underway for drills and shaft seal was pouring water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2018
Resolved 6 August 2018
Resolution: Shaft seal replaced; test SAT.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 April 2017 Resolved
Provide log book for drills.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided log book for drills
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 April 2017 Resolved
Provide CG light list.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided CG light list.
Navigation › Piloting/Steering › Marine Charts
Issued 17 April 2017 Resolved
Provide chart of operating area.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided chart of operating area.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 April 2017 Resolved
Provide service report for fire extinguishers.
Action required: 705 - Other - as specified
Resolved 20 April 2017
Resolution: Provided service report.
Engineering › Steering Gear System › Rudder
Issued 14 April 2016 Resolved
Provide tiller for emergency steering.
Due 12 May 2016
Resolved 12 May 2016
Resolution: Emergency tiller provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016 Resolved
Update expired items in first aid kit.
Due 18 April 2016
Resolved 18 April 2016
Resolution: Expired items have been replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 April 2016 Resolved
Install retro tape on ring buoy.
Due 2 May 2016
Resolved 18 April 2016
Resolution: Tape has been placed on ring buoy.
Engineering › Lubricating Oil Service System › Hose
Issued 14 April 2016 Resolved
Replace broken hose clamp on oil cooler.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Clamp has been renewed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 April 2016 Resolved
Conduct and provide current servicing report.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Service has been completed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 14 April 2016 Resolved
Prove proper operation of fireboy shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 April 2016
Resolution: Proved proper operation of fireboy shutdown.
Stability › Watertight Integrity › General
Issued 31 March 2016 Resolved
Install metallic plug in through hull fitting that is no longer being used.
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: Metallic plug has been installed.
Construction/Loadline › Hull › Side Shell
Issued 31 March 2016 Resolved
Submit repair plan to repair the FRP side shell that is loose IWO the side shell and cap.
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: Received repair plan.
Construction/Loadline › Hull › Side Shell
Issued 31 March 2016 Resolved
Repair dime size damage to FRP in stern, port side, 6" above the water line.
Action required: 705 - Other - as specified
Resolved 11 April 2016
Resolution: Repairs made by scarfing in new glass and epoxy resin.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 February 2012 Resolved
Replace worn propeller.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 15 February 2012 Resolved
Replace shaft cutlass bearing.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 February 2012 Resolved
Replace bilge pump through hull fitting and install positive shut-off valve.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Construction/Loadline › Hull › Hull Plating
Issued 15 February 2012 Resolved
Repair cracked fiberglass located port side rub rail.
Action required: 705 - Other - as specified
Resolved 21 February 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 26 July 2011 Resolved
Repair/replace light fixture, located in passenger area.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 1 August 2011
Resolution: Light fixture was replaced.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 26 July 2011 Resolved
Prove proper operation of engine shudown switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 August 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2011 Resolved
Install machinery guard on engine belt drive.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 1 August 2011
Operations/Management › Drills/Instruction › Fire
Issued 26 July 2011 Resolved
Post emergency instruction list.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2011
Resolved 1 August 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 July 2011 Resolved
Prove proper operation of Navigation lights, vessel is restricted from operating at night or during reduced visibility until deficiency is corrected.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 1 August 2011
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 26 July 2011 Resolved
Provide one additional flash light.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 1 August 2011
Personnel › Training › First Aid/CPR
Issued 26 July 2011 Resolved
Update CPR and First Aid certifications.
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 1 August 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 July 2011 Resolved
Replace and install mounting bracket for fwd portable extinguisher.
Action required: 705 - Other - as specified
Due 3 August 2011
Resolved 1 August 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 July 2011 Resolved
Prove proper operation of fixed fire extinguishing auto engine shutdown.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2011
Resolved 1 August 2011
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 July 2011 Resolved
Marine employer failed to have required personnel covered in random testing pool.
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 6 December 2011
Resolution: Required personnel covered in random testing pool.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 26 July 2011 Resolved
Marine employer failed to comply with EAP display requirements (Policy, Hotline numbers, Substance Abuse Professional (SAP) name and contact information).
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 6 December 2011
Resolution: Marine employer complied with EAP display requirements.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 July 2011 Resolved
Marine employer failed to provide proof of 1 hour EAP training for Supervisor(s).
Action required: 705 - Other - as specified
Due 26 August 2011
Resolved 6 December 2011
Resolution: Proof of 1 hour EAP training for supervisors.
Engineering › Bilge Water Management System › Valve
Issued 23 July 2009 Resolved
Install a positive shutoff valve at each hull penetration for each automatic bilge pump discharge.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 2 September 2009
Fire Fighting › Fire Bucket › Availability
Issued 23 July 2009 Resolved
Provide one fire bucket with lanyard.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 2 September 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 July 2009 Resolved
Demonstrate proper operation of the forward mast light.
Action required: 705 - Other - as specified
Due 23 August 2009
Resolved 2 September 2009
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 19 July 2007 Resolved
Aft engine space bulkhead was deteriorated and falling down, thus not effectively sealing the engine space from the rest of the vessel, which makes the fixed fire fighting bottle too small. Properly seal aft engine space bullkhead.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2007
Resolved 30 January 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 July 2007 Resolved
Bilge alarm inoperable, properly repqir bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2007
Resolved 30 January 2008
Engineering › Fuel Oil Service System › Vent Pipe
Issued 19 July 2007 Resolved
The fuel tank vent was on the end of a hose affixed to the tank but laying in the bilges. It had the 30 x 30 mesh fitting on the end not properly mounted on the exterior of the hull.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2007
Resolved 30 January 2008
Unknown
Issued 8 August 2001 Resolved
Prior to issuing COI, demonstrate operation of main engine since it has been replaced due to major deformities.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Lifesaving
Issued 8 August 2001 Resolved
Prior to issuing COI, conduct satisfactory fire and man overboard drills inthe presence of CG marine inspector.
Condition: Unknown
Due 8 August 2001
Resolved 8 August 2001
Engineering
Issued 8 August 2001 Resolved
Prior to issuing COI, provide access panel to fuel shutoff valves.
Condition: Unknown
Due 9 August 2001
Resolved 20 January 2004
Fire Fighting
Issued 20 July 2000 Resolved
Fixed fire fighting extinguishing agent not inspected annualy as required.
Condition: Unknown
Due 20 July 2000
Resolved 22 July 2000
Engineering
Issued 5 August 1998 Resolved
PROVE PROPER OPERATION OM MDE LUBE OIL PRESSURE.
Condition: Unknown
Due 5 August 1998
Resolved 5 August 1998
Engineering
Issued 20 August 1996 Resolved
Secure fuel tank. (loose fasteners)
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Lifesaving
Issued 20 August 1996 Resolved
Provide proper painter 60' painter on ring life buoy.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Engineering
Issued 20 August 1996 Resolved
Properly align vent line for fuel tank.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Documentation
Issued 20 August 1996 Resolved
Rewrite man overboard procedure on emergency check list to relect current operation.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Electrical
Issued 20 August 1996 Resolved
Remove dead end wires in engine comptartment.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Construction/Loadline
Issued 20 May 1994 Resolved
COMPLETE REPAIR TO GOUGES IN STEM FIBERGLASS.
Condition: Unknown
Due 20 May 1994
Resolved 25 May 1994
Fire Fighting
Issued 20 May 1994 Resolved
PROVIDE ONE ADDITIONAL BII FIRE EXTINGUISHER.
Condition: Unknown
Due 20 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 20 May 1994 Resolved
CONDUCT REPAIR TO DELAMINATED AREAS PORTSIDE WHERE HULL MEETS KEEL AND AFT OF RUDDER POST.
Condition: Unknown
Due 20 May 1994
Resolved 25 May 1994
Accommodation/Occupational Safety
Issued 20 May 1994 Resolved
CONDUCT WELDING REPAIR TO CRACKS IN ALUMINUM BOARDING PLATFORM.
Condition: Unknown
Due 20 May 1994
Resolved 25 May 1994
Documentation
Issued 20 May 1994 Resolved
PROVIDE ORIGIONAL STABILITY LETTER TO BE CARRIED ON VESSEL.
Condition: Unknown
Due 20 May 1994
Resolved 25 May 1994
Lifesaving
Issued 20 May 1994 Resolved
RENEW RING BUOY.
Condition: Unknown
Due 20 May 1994
Resolved 25 May 1994
Fire Fighting
Issued 10 October 1990 Resolved
TOTAL NUMBER OF EXTINGUISERS MUST BE DETERMINED FOR THIS SPECIAL CASE VSL. OWNER SENDING LETTER TO RECOMMEND NUMBER OF EXTINGUISHERS AND DOCUMENT FILE
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990

Ownership record