MAURY USCG vessel records
← All vessels

CAPT. SHEPLER

Built
1986
Last inspected
11 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 May 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY2616
270757
Flag
UNITED STATES
Maury page id
psix-270757

Documentation record

Registered dimensions (L × B × D)74.6 ft × 20.0 ft × 7.8 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMINUM BOATS, INC. · JEAN LAFITTE, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMACKINAW CITY, MI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 21 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 29 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 29

11 May 2026 Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8387500
17 February 2026 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8305580
20 August 2025 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8215609
26 June 2025 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8172316
20 November 2024 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8037722
8 May 2024 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7913665
20 September 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814596
8 May 2023 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7689119
11 August 2022 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7534365
12 May 2022 COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7437388
20 April 2022 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7434900
14 February 2022 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7396079
4 October 2021 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7331616
21 June 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7246569
7 January 2021 Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7122632
25 August 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7042268
5 August 2020 Annual Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7026320
28 October 2019 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6860521
11 April 2019 Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6674691
13 November 2018 Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619858
25 October 2018 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6568677
25 September 2018 Annual Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6548940
24 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6547486
27 February 2018 Examination of Repairs · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6393418
29 September 2017 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277708
1 May 2017 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6142768
19 October 2016 Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6035428
22 June 2016 In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5925104
14 April 2016 In-Service Inspection · Plan Review (Other than "T") · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5873255

Deficiency record · 22

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 May 2022 Resolved
Bilge alarm panel audible did not function. Panel was replaced, all tests sat.
Action required: 10 - Deficiency Rectified
Resolved 12 May 2022
Resolution: corrected prior to my departure.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 21 June 2021 Resolved
Found WTD indicator light to not be functioning correctly at the operating station. Make indicator function correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 July 2021
Resolved 30 June 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020 Resolved
Markings reflecting the number of lifejackets stowed inside deck containers are not accurate or not present. Correct the marking to accurately reflect the number of lifejackets stowed inside container.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2020
Resolved 25 August 2020
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 5 August 2020 Resolved
Hydrostatic release on port side IBA was found expired. Replace hydrostatic release.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2020
Resolved 25 August 2020
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018 Resolved
Replace battery in waterlight attached to lifebuoy at operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 25 October 2018
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2018 Resolved
Each fire station must be outfitted with a spanner wrench.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2018
Resolved 25 October 2018
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2018 Resolved
Properly secure ladder at entry way to engine room.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2018
Resolved 26 April 2019
Resolution: Welded both sides of ladder; properly secured
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 September 2018 Resolved
The vessel is currently broadcasting (1) Improper Call Sign, (2) Zero Length and Beam, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 1 May 2019
Resolution: Received notification of AIS broadcasting correction from vessel owner. Verified no errors in VIVS.
Fire Fighting › Fire Hoses › Connections
Issued 12 October 2017 Resolved
Spanner wrenches must be at each fire station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 15 November 2017
Resolution: completed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 12 October 2017 Resolved
Properly mount aft main cabin PFE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2017
Resolved 15 November 2017
Resolution: mounted.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 October 2017 Resolved
Make engineroom and V-drive room emergency escape route safe from exposed rotating machinery hazards.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 26 April 2018
Resolution: rotating machinery guards properly installed
Construction/Loadline › Structures › Superstructure
Issued 12 October 2017 Resolved
Submit repair proposal & after approval, effect permanent repairs to port side forwardmost window area structural fractures.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 May 2018
Resolved 5 April 2018
Resolution: Permanent repairs effected to cracks.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 October 2016 Resolved
Post emergency procedures in the pilot house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Posted.
Documentation › Certificates/Documents › Stability Letter
Issued 19 October 2016 Resolved
Post stability letter in the pilot house.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 October 2016 Resolved
Replace broken fire extinguisher bracket in the pilothouse.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Replaced.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 October 2016 Resolved
Provide radio inspection certificate.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Sighted Inspection Cert.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 19 October 2016 Resolved
Provide newly installed carpet specifics sheet.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Completed.
Fire Fighting › Means of Escape › Blocked
Issued 19 October 2016 Resolved
Make main cabin hatch closure fittings accessible/operational. Newly installed carpet is blocking.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Corrected.
Engineering › Fuel Oil Service System › Tank
Issued 19 October 2016 Resolved
Monitor fuel tank compartment after each refueling to ensure repaired fuel drip corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 October 2016
Resolved 26 October 2016
Resolution: Repaired and monitored.
Construction/Loadline › Hull › Weld
Issued 19 October 2016 Resolved
Repair cracked welds as noted in various compartments prior to next operating season.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2017
Resolved 1 May 2017
Resolution: Repaired.
Lifesaving › Lifebuoys › Serviceable
Issued 19 October 2016 Resolved
Lifesaving equipment must be in serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 19 October 2016
Resolution: Corrected on-the-spot, RLB was replaced.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 October 2016 Resolved
Provide Sr. deckhand desination letter/list for this vessel and entire company.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 1 May 2017
Resolution: Sighted.

Ownership record