A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Multiple instances of dead-end wiring were observed on board, such as: the second deck battery box, engine room, and second compartment.
Openings in the breaker box on board were observed and need to be covered.
The electrical outlet in the engine room was observed
without a cover.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: All loose wiring and outlet covers closed and sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
A pinhole leak was observed on the starboard main engine wand was leaking oil.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Leaking line replace and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 September 2024
Resolved
Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe.
An exhaust cooling water leak was observed on the starboard main engine.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Leaks repaired, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2024
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor.
Grounding wires connected to fuel shutoff valves were improperly installed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Grounding wires replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 September 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operational test of all overboard discharge and intake valves and watertight bulkhead pipe penetration valves.
@ overboard discharges were observed on the starboard side bulkhead of the engine room to be fitted without drains.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Replaced, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 September 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
General condition and cleanliness of engine room, including machinery parts, surfaces, and bilges lacked cleanliness.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Cleaned, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Numerous sections of fiberglass hull and wood framing in the vessels structure were found to with significant wastage, namely in the forward compartment, second and third compartments, engine room, and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Fiberglass repairs completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 September 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve.
The painter must:Have a breaking strength of at least 680 kilograms (1,500 pounds).
A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the name of the manufacturer, lot designation or serial number, approval number, dimensions, and number of persons capacity. Space must be provided for the date, and the identification of the independent laboratory.
Starboard life float was observed to have a hole in the side and a worn/wasted lifeline. Both life floats were without a nameplate.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Nameplates cleaned and legible, lifelines replaced, life float repaired, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant.
An adult life jacket must be provided for each person carried on board a vessel.
Numerous life jackets were observed to be in need of new retroreflective tape, and several lifejackets were in need of replacement due to wasted material.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Reflective tape replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 September 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails.
Ladders leading to the 2nd deck from the bow and stern were observed to be without a lifeline.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Lifelines installed, ladder cracks welded, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 May 2022
Resolved
Replace deck frames and deck plywood, seal collision bulkhead, seal hole on deck port side of ladder and grind water intrusion around STBD side stiffener in fore peak.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 May 2022
Resolved
Remove every other ceiling panel for inspectors to asses deck condition.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Clean engine room batteries, engine oil and exhaust leak residue.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2022
Resolved
Replace FRP MDE exhaust pipe.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Repair air vents on fantail. (both sides)
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Replace STBD side inboard steering stop.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Clean fuel tank for further inspection.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2021
Resolved
Using non combustable material to bracket the bundled electrical wires just foward of the engines, using a bracket every 24 inches.
Action required: 705 - Other - as specified
Due 10 August 2021
Resolved 10 August 2021
Resolution: Recieved picture evidence of proper bracketing of the wiring in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 August 2021
Resolved
Line attached to weak link is tankgled. Untangle line and connect the weak link properly under the spooled line so that the line can pay out properly in an emergency.
Action required: 705 - Other - as specified
Due 10 August 2021
Resolved 10 August 2021
Resolution: Recieved picture evidence of proper arrangement of the weak link and line for the life floats.
Lifesaving › Lifefloat › Painter
Issued 6 June 2017
Resolved
Install a longer painter line, as required, for lifefloats. 46CFR180.137(e)(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 6 June 2017
Resolution: New painter line of adequate length was installed on life floats. Deficiency rectified.
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 June 2017
Resolved
Replace retroreflective tape on lifefloats (02 pieces) with approved type. 46CFR160.027.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 12 June 2017
Resolution: New retroreflective tape put on lifefloat (See photos). Deficiency rectified.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 June 2017
Resolved
Replace retroreflective tape on lifejackets with approved type. 46CFR185.604(h).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 12 June 2017
Resolution: New retroreflective tape placed on life jackets (See photos). Deficiency rectified.
Construction/Loadline › Hull › Side Shell
Issued 28 December 2015
Resolved
Cease all repairs to the vessel until the following are satisfied by a USCG Marine Inspector: Provide hull survey report from a qualified marine surveyor attesting to the structural integrity of the vessel's entire hull. Provide a repair proposal from a qualified fiberglass repair technician for all areas of the hull needing repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2016
Resolution: All indicated areas were completed per repair proposal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2014
Resolved
Remove open wires at operating station.
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 3 June 2014
Resolution: Received photo attesting to repair.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 21 May 2014
Resolved
Correct max upper deck capacity labels for 25 persons.
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 3 June 2014
Resolution: Received photo attesting to repair.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 21 May 2014
Resolved
Renew lock on damper, stbd side.
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 3 June 2014
Resolution: Received photo attesting to repair.
Construction/Loadline › Structures › Deck Plating
Issued 29 August 2011
Resolved
Provide repair proposal for lazarette transverse under deck beam repair/replacement from transom fwd 1st two beams. 1a) Repair under deck beams IAW approved repair proposal, wood NVIC and approved vsl construction plans.
Action required: 705 - Other - as specified
Due 5 October 2011
Resolved 21 September 2011
Construction/Loadline › Hull › Bottom Plating
Issued 29 August 2011
Resolved
Sand back to good fiberglass all areas identified by USCG/owner on the hull and keel. Make available for inspection.
Action required: 705 - Other - as specified
Resolved 5 September 2011
Construction/Loadline › Structures › Trunk
Issued 29 August 2011
Resolved
Sand back to good fiberglass all areas on the main deck gunnels IWO handrails identified by USCG.
Action required: 705 - Other - as specified
Resolved 5 September 2011
Construction/Loadline › Hull › Bottom Plating
Issued 29 August 2011
Resolved
Provide repair proposal for areas requiring repairs on hull (i.e. materials used: glass, resin, etc...)
Action required: 705 - Other - as specified
Resolved 5 September 2011
Stability › Weathertight Integrity › General
Issued 22 July 2009
Resolved
Replace FWD center Main Deck Window.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Stability › Watertight Integrity › General
Issued 22 July 2009
Resolved
Scale back main deck port and starboard side from bow to aft end of main cabin for USCG Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Construction/Loadline › Hull › Transverse Frame
Issued 22 July 2009
Resolved
Properly grind back to good fiberglass all delaminated tabs in all compartments and replace as original IAW approved plans.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Stability › Watertight Integrity › General
Issued 22 July 2009
Resolved
Remove angle iron on port/stbd side for USCG inspection of gunwales.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Stability › Watertight Integrity › General
Issued 22 July 2009
Resolved
Make gunwales watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Construction/Loadline › Hull › Side Shell
Issued 22 July 2009
Resolved
Make aft Accom, Space available for inspection (side shell, Hull and overhead).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2009
Construction/Loadline › Structures › Deck Plating
Issued 22 July 2009
Resolved
Provide repair proposal for broken under deck transverse beams in aft Accom, Space (either via E-mail or Fax).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Construction/Loadline › Hull › Longitudinal Frame
Issued 22 July 2009
Resolved
Crop and renew aft area of engine angle iron mounting bracket port side (on longitudinal frame).
Action required: 705 - Other - as specified
Resolved 6 August 2009
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 22 July 2009
Resolved
Make repairs to aft section of port exhaust fiberglass tube that is leaking IWO aft E/R bhd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 July 2009
Resolved
Service all fiberglass exhaust tubes IWO flexible couplers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 July 2009
Resolved
Make repairs to port side exhaust tube in steering/fuel void IWO fwd BHD. Scale down both port exhaust tubes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Engineering › Feedwater/Condensate Water System › Piping
Issued 22 July 2009
Resolved
Make proper repairs to port engine raw water flexible hose leading to exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 22 July 2009
Resolved
Re-tab MSD holding tank brackets on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Construction/Loadline › Hull › Hull Plating
Issued 22 July 2009
Resolved
Grind all spots on hull identified by Owner and USCG to Good fiberglass using good marine practice (12 to 1 scarf) and make available for USCG inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2009
Engineering › Feedwater/Condensate Water System › Valve
Issued 22 July 2009
Resolved
Make through hull valves in STBD side engine room available for USCG inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2009
Stability › Watertight Integrity › General
Issued 22 July 2009
Resolved
Grind back to good fiberglass aft deck IWO transom where stern gate pass-through is located.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 22 July 2009
Resolved
Secure ladder going into Accom space aft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2008
Resolved
Update first aid kit IAW 46 CFR 160.041.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2008
Resolved
Under steering consol remove dead end wires and make proper splices in 2nd bunk compartment remove dead end wires.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Engineering › Bilge Water Management System › Valve
Issued 21 May 2008
Resolved
Provide positive shutoff for electric bilge pump in 2nd bunk compartment and provide suitable hose IAW MFG instruction.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 21 May 2008
Resolved
Post operation procedures for fire and bilge system in E/R.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 May 2008
Resolved
Make fwd bulkhead and aft bulkhead in E/R watertight.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 May 2008
Resolved
Make proper repairs IAW approved plans to watertight bulkhead separating E/R and aft bunk compartment.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Fire Fighting › Fire Pumps › Pressure
Issued 21 May 2008
Resolved
Provide gage on fire pump.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 21 May 2008
Resolved
Provide proper battery covers.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 21 May 2008
Resolved
Provide/make repairs to lagging in E/R on all exhausts.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 21 May 2008
Resolved
Show proper operation of "men’s" head.
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 21 May 2008
Resolved
Remove sign on access to bunk compartments stating "fire extinguisher inside".
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2007
Resolved
Make proper repairs to areas identified on hull.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: onboard
Construction/Loadline › Hull › Strut/Cross Tie
Issued 16 May 2007
Resolved
Grind out and present starboard strut hull attachment and properly repair.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: onboard
Construction/Loadline › Hull › Side Shell
Issued 16 May 2007
Resolved
Make proper repairs to port quarter.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: onboard
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 May 2007
Resolved
Secure all hand rails and repair broken welds.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 29 June 2007
Resolution: onboard
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 16 May 2007
Resolved
Wire brush and present for inspection the fuel tank fittings.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 6 July 2007
Resolution: All fittings presented, owner has ordered new tanks from Sunshine Marine Tanks.
Engineering › Steering Gear System › Bracket/Clamp
Issued 16 May 2007
Resolved
Present repair proposal for steering gear support.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 6 July 2007
Resolution: onboard, test sat.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 May 2007
Resolved
Properly seal all penetrations in aft engine room bulkhead.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 29 June 2007
Resolution: onboard
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 16 May 2007
Resolved
Renew port and starboard shaft log hose and clamps.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: onboard
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007
Resolved
Remove dead end wiring and renew all solid core "Romex" wire with approved stranded wire.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 29 June 2007
Resolution: onboard
Construction/Loadline › Penetrations › Flange Pad
Issued 16 May 2007
Resolved
Renew broken transducer block.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: onboard
Construction/Loadline › Structures › Deck Plating
Issued 16 May 2007
Resolved
Submit repair proposal and make proper repairs to engine room overhead supports and deck transverse beams.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 29 June 2007
Resolution: onboard
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2007
Resolved
Install opening and present for inspection all areas of the bilge.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 24 May 2007
Resolution: onboard
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 August 2006
Resolved
Provide current navigation pubs.
Due 16 August 2006
Resolved 16 May 2007
Resolution: onboard
Communications › Audible Communications › Horn/Whistle
Issued 9 August 2006
Resolved
Provide operational horn IAW COLREGS.
Due 16 August 2006
Resolved 16 May 2007
Resolution: onboard
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 August 2006
Resolved
Wire stern light to operate with running lihgts.
Due 16 August 2006
Resolved 16 May 2007
Resolution: onboard
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 August 2006
Resolved
Provide visual indicator for aft bunk room bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2006
Resolved 11 August 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 9 August 2006
Resolved
Provide 19 adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2006
Resolved 11 August 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 May 2005
Resolved
Properly label emergency fuel shutoff valve reach rods
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 31 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2005
Resolved
Remove or properly secure all dead end wires.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 9 August 2006
Engineering › Lubricating Oil Service System › Gauge
Issued 10 May 2005
Resolved
Repair or replace oil pressure gauge for port main engine.
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 9 August 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 10 May 2005
Resolved
Remove rope exhaust hanger on starboard side and replace with metal hanger.
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 9 August 2006
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 May 2005
Resolved
Submit repair proposal to remove generators and all associated equipment and systems from vessel. prior to next dry-docking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 9 August 2006
Construction/Loadline › Hull › Bottom Plating
Issued 10 May 2005
Resolved
Submit repair proposal to permanently fill generator raw water suction thru-hull hole.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2005
Resolved 31 May 2005
Engineering › Fuel Oil Service System › Hose
Issued 10 May 2005
Resolved
Replace fuel hose on starboard main engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 9 August 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2005
Resolved
Remove plastic wire ties and hang wire with metal hangers in engine space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 9 August 2006
Fire Fighting › Fire Main › Pressure
Issued 10 May 2005
Resolved
Install gauge on discharge side of fire pump to show a minimum of 60 PSI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 9 August 2006
Lifesaving › Lifefloat › Float-free Link
Issued 28 July 2004
Resolved
Provide proper weak link and painter to life floats.
Condition: Placed in Improper Service
Due 28 August 2004
Resolved 28 July 2004
Lifesaving › Lifefloat › Float Free
Issued 28 July 2004
Resolved
Arrange 8 person life float for float free launch.
Condition: Placed in Improper Service
Due 28 August 2004
Resolved 28 July 2004
Operations/Management › Drills/Instruction › Not Conducted
Issued 28 July 2004
Resolved
Log training with names, dates and topics apart from drills. (every 3 months).
Condition: Placed in Improper Service
Due 28 August 2004
Resolved 5 August 2004
Electrical › Electric Generation Source (service) › Generator
Issued 28 July 2004
Resolved
Prove proper operation of both gensets including frequency, amps, voltage guages, oil pressure and water temp. The gensets are not to be used until proved, including main switchboard.
Condition: Improper/Lack of Maintenance
Due 28 August 2004
Resolved 5 August 2004
Engineering › Bilge Water Management System › Piping
Issued 28 July 2004
Resolved
Make proper repairs to fire/bilge piping system as discussed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 5 August 2004
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 28 July 2004
Resolved
Repair broken hand rail at forward berthing ladder.
Condition: Improper/Lack of Maintenance
Due 28 August 2004
Resolved 5 August 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 July 2004
Resolved
Prove bilge alarms in engine room and forward berthing areas.
Condition: Improper/Lack of Maintenance
Due 28 August 2004
Resolved 5 August 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 July 2004
Resolved
Properly attach dead front cover at circuit breaker panel in engine room.
Condition: Improper/Lack of Maintenance
Due 28 August 2004
Resolved 5 August 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 28 July 2004
Resolved
Prove proper operation of fixed fire fighting system (manual pull, engine shutdown and restart).
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 5 August 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 28 July 2004
Resolved
Prove fixed FE 241 bottle is correct size for engine room.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 5 August 2004
Lifesaving › Lifebuoys › Serviceable
Issued 28 July 2004
Resolved
Renew life ring on port side.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 28 July 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 July 2004
Resolved
Provide whistles on lifejackets (15).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 28 July 2004
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 28 July 2004
Resolved
Repair shore tie plug where pulled out of fitting.
Condition: Improper/Lack of Maintenance
Due 28 August 2004
Resolved 5 August 2004
Communications › Radio Communications › VHF Radiotelephone
Issued 28 July 2004
Resolved
Provide two operating VHF-FM radios in wheel house.
Condition: Improper/Lack of Maintenance
Due 28 August 2004
Resolved 28 July 2004
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 28 July 2004
Resolved
Provide an electronic positioning device.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 5 August 2004
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 28 July 2004
Resolved
Make proper repairs to fuel oil leak on valve at bottom of fuel oil tank in aft lazzerette. The vessel may be operated until fuel is used up, no refueling is allowed. The unit must be repaired no later than seven (07) days after the vessel is back in operation.
Condition: Improper/Lack of Maintenance
Due 4 August 2004
Resolved 5 August 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 28 July 2004
Resolved
Properly label fixed fire fighting manual pull station.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2004
Resolved 5 August 2004
Personnel › Certificates/Documents/Licenses
Issued 17 September 2003
Resolved
Provide FCC Operator's Permit for Master [name withheld]
Due 17 October 2003
Resolved 23 September 2003
Navigation › Piloting/Steering
Issued 17 September 2003
Resolved
Provide updated Light List and Coast Pilot excerpts. LEGACY COMPONENT DESC: Coast Guard Light List
Due 17 October 2003
Resolved 19 September 2003
Personnel › Training
Issued 17 September 2003
Resolved
Provide training records and initial orientation records as per 46 CFR 185.420. LEGACY COMPONENT DESC: Familiarization Training
Due 17 October 2003
Resolved 19 September 2003
Documentation › Logs/Records
Issued 17 September 2003
Resolved
Provide lifesaving equipment maintenance records.
Due 17 October 2003
Resolved 19 September 2003
Engineering › Fuel Oil Service System
Issued 17 September 2003
Resolved
Prior to carriage of passengers, make proper repairs to fuel lines. LEGACY COMPONENT DESC: Piping
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2003
Engineering › Bilge Water Management System
Issued 17 September 2003
Resolved
Renew flexible hose on bilge suction line in Lazzerette. LEGACY COMPONENT DESC: Piping
Due 17 October 2003
Resolved 19 September 2003
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 17 September 2003
Resolved
Relocate manual pull station at engine room entrance. LEGACY COMPONENT DESC: Operating Controls
Due 17 October 2003
Resolved 19 September 2003
Fire Fighting › Fire Pumps
Issued 17 September 2003
Resolved
Replace flex hose on starboard engine fire/bilge pump.
Due 17 October 2003
Resolved 19 September 2003
Lifesaving › Embarkation Appliances/Stations
Issued 17 September 2003
Resolved
Provide permanent means to access lifefloats for manual release. LEGACY COMPONENT DESC: Steps
Due 17 October 2003
Resolved 11 December 2003
Lifesaving › Liferaft Equipment
Issued 17 September 2003
Resolved
Renew lifeline on port side lifefloat. LEGACY COMPONENT DESC: lifeline
Due 17 October 2003
Resolved 11 December 2003
Engineering › Bilge Water Management System
Issued 17 September 2003
Resolved
Repair high level alarm light for Lazzerette. LEGACY COMPONENT DESC: high level alarm
Due 17 October 2003
Resolved 11 December 2003
Lifesaving › Hand Flares
Issued 17 September 2003
Resolved
Provide watertight box for flares. LEGACY COMPONENT DESC: Storage
Due 17 October 2003
Resolved 19 September 2003
Electrical › Lighting (service)
Issued 17 September 2003
Resolved
Provide safety covers for light fixtures in engine room. LEGACY COMPONENT DESC: Lighting Fixture
Due 17 October 2003
Resolved 11 December 2003
Engineering › Generator (propulsion-electric)
Issued 17 September 2003
Resolved
Provide Nameplates for gensets. LEGACY COMPONENT DESC: Name Plate
Due 17 October 2003
Resolved 19 September 2003
Engineering › Sea-water System (primary cooling)
Issued 17 September 2003
Resolved
Renew flex hoses on raw water intakes for center and port side engines. LEGACY COMPONENT DESC: Piping
Due 17 October 2003
Resolved 19 September 2003
Engineering › Diesel Engine (propulsion-electric)
Issued 17 September 2003
Resolved
Tighten up starboard, aft, inboard propulsion engine mounting bolt.
Due 17 October 2003
Resolved 19 September 2003
Engineering › Diesel Engine (propulsion-electric)
Issued 17 September 2003
Resolved
Renew engine transmission control cable on port engine.
Due 17 October 2003
Resolved 11 December 2003
Lifesaving
Issued 17 September 2003
Resolved
Provide a first aid kit meeting the 160.041 approval series or a kit with equivalent contents. LEGACY COMPONENT DESC: First Aid Kit
Due 17 October 2003
Resolved 19 September 2003
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2003
Resolved
Make vessel available for re-inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2003
Construction/Loadline › Hull
Issued 29 May 2003
Resolved
Properly repair areas indicated by marine inspector on exterior hull. LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2003
Resolved 5 June 2003
Construction/Loadline › Hull
Issued 29 May 2003
Resolved
Crop out and renew deck above lazarette. LEGACY COMPONENT DESC: Deck
Due 29 June 2003
Resolved 10 June 2003
Construction/Loadline › Hull
Issued 29 May 2003
Resolved
Grind to good material in bunk compartment bilge on starboard side of keel where FRP is delaminating. LEGACY COMPONENT DESC: bilge
Condition: Unknown
Due 29 June 2003
Resolved 10 June 2003
Construction/Loadline › Hull
Issued 29 May 2003
Resolved
Properly repair delaminated areas on starboard side engine room side shell stiffeners. LEGACY COMPONENT DESC: Side Shell/stiffener
Condition: Unknown
Due 29 June 2003
Resolved 10 June 2003
Construction/Loadline › Hull
Issued 29 May 2003
Resolved
Poperlt repair cracked and delaminated area in foer peak on port side. LEGACY COMPONENT DESC: Side Shell/fore peak
Condition: Unknown
Due 29 June 2003
Resolved 10 June 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 July 2002
Resolved
Raise masthead light or lower port and starboard nav. lights iaw Annex I (2) (g) of the COLREGS. LEGACY COMPONENT DESC: Navigation Lights
Due 24 July 2002
Resolved 28 July 2004
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 July 2002
Resolved
Repair water leaks on exhaust piping in way of lazarette (stbd engine and port generator).
LEGACY COMPONENT DESC: Piping (exhaust)
Due 24 July 2002
Resolved 28 July 2004
Engineering › Bilge Water Management System › Piping
Issued 17 July 2002
Resolved
Install valve at skin of the vessel on discharge side of Rule pump.
LEGACY COMPONENT DESC: Valve
Due 24 July 2002
Resolved 28 July 2004
Accommodation/Occupational Safety
Issued 7 May 2001
Resolved
Install PA system for the vessel.
Condition: Unknown
Due 10 May 2001
Resolved 15 May 2001
Unknown
Issued 12 May 2000
Resolved
LABEL STBD SIDE FUEL SHUT OFF VALVES.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000
Resolved
REPAIR THREE DECK HOLES COMPROMISING LAZERETTE SPACE WATERTIGHT INTEGRITY; STBD SIDE NEAR RUB RAIL, PORT SIDE FUEL CAP, AND HATCH ASSEMBLY.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Documentation
Issued 12 May 2000
Resolved
PROVIDE TECH REPORT PROVING ANNUAL SERVICING FOR FIXED FIRE EXTINGUISHING SYSTEM HAS BEEN COMPLETED.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 12 May 2000
Resolved
PRIOR TO THE CARIAGE OF PASSENGERS, PROVIDE 60 P.S.I. OF WATER PRESSURE AT PUMP OUTLET ON STARBOARD FIRE PUMP.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 12 May 2000
Resolved
REPLACE PORT/STBD FIRE PUMP GAUGES.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000
Resolved
REPLACE "OVERBOARD TO STARBOARD VALVE" LOCATED AT THE FIRE/BILGE PIPING MANIFOLD.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000
Resolved
PROVIDE WATERTIGHT SUBDIVISION ON FORE/AFT BULKHEADS IN ENGINE ROOM.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Electrical
Issued 12 May 2000
Resolved
PROVIDE ENGINE ROOM LIGHT COVERS.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Engineering
Issued 12 May 2000
Resolved
PROVIDE FLAME BOWL ON CENTER MDE FUEL FILTER.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Engineering
Issued 12 May 2000
Resolved
REPAIR WATER LEAK ON PORT ENGINE WET EXHAUST.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Electrical
Issued 12 May 2000
Resolved
REPAIR WATER LEAK ON PORT GENERATOR.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Engineering
Issued 12 May 2000
Resolved
REPLACE FUEL HOSE FROM RACOR TO ENGINE ON PORT ENGINE.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 12 May 2000
Resolved
PROVIDE B-II FIRE EXTINGUISHERS AS REQUIRED IN BOTH ACOOMODATION SPACES.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000
Resolved
PROVIDE WATERTIGHT GASKETS FOR BOTH THE FOREPEAK AND LAZERETTE HATCHES.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Construction/Loadline
Issued 12 May 2000
Resolved
PLUG THRU BULKHEAD PENETRATION NEAR E/R LADDER.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Engineering
Issued 12 May 2000
Resolved
REPLACE PORT ENGINE OIL PRESSURE GAUGE.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Unknown
Issued 12 May 2000
Resolved
LABEL UPPER DECK LEVEL PASSENGER LIMIT IN CONSPICUOUS SPOT ALONG LADDERWELLOR BULKHEAD LEADING TO 01 DECK.
Condition: Unknown
Due 23 May 2000
Resolved 12 May 2000
Fire Fighting
Issued 12 May 2000
Resolved
PROVIDE AUTOMATIC ENGINE SHUTDOWNS IN CASE OF RELEASE OF FIXED FIRE EXTINGUISHING AGENT AND PROVE SYSTEM SHUTS DOWN ALL ENGINES IN E/R INCLUDING GENERATORS.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Electrical
Issued 25 May 1999
Resolved
Provide compression fitting for shore based power and compressor "boxes". (prior to 03 June, 1999)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1999
Resolved 11 June 1999
Electrical
Issued 25 May 1999
Resolved
Provide caps for battery in engine room (prior to 03 June, 1999)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 25 May 1999
Resolved
Permanently label bilge manifold (prior to 03 June, 1999)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1999
Resolved 11 June 1999
Electrical
Issued 25 May 1999
Resolved
Cap missing breakers in circuit breaker boxes (prior to 03 June, 1999)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 25 May 1999
Resolved
Conduct operational test of fixed fire fighting in the presence of a CG marine inspector (prior to 03 June, 1999)
Condition: Unknown
Due 4 June 1999
Resolved 11 June 1999
Construction/Loadline
Issued 25 May 1999
Resolved
Provide (2) fixed bilge pumps IAW 46 CFR 182.25 (prior to the carriage of passengers)
Condition: Unknown
Due 27 May 1999
Resolved 11 June 1999
Lifesaving
Issued 25 May 1999
Resolved
Repair/replace primary lifesaving (total passenger count reduce by 22 persons)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 25 May 1999
Resolved
Provide (1) one B-1 fire extinguishers (prior to the carriage of passengers)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1999
Resolved 11 June 1999
Construction/Loadline
Issued 25 May 1999
Resolved
Provide visual alarm for water high level alarms(prior to 03 June, 1999)_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 25 May 1999
Resolved
Provide pressure gauge at center MDE fire pump (prior to 03 June, 1999)
Condition: Unknown
Due 4 June 1999
Resolved 11 June 1999
Fire Fighting
Issued 25 May 1999
Resolved
Calibrate fire pump pressure gauges (prior to carrying passengers)
Condition: Unknown
Due 4 June 1999
Resolved 11 June 1999
Lifesaving
Issued 20 May 1998
Resolved
Properly replace port and stb nettings and sidelines. Material condition of equipment is very deteriorated.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Properly relocated 406 mhz EPIRB in order to maintain a float free arrangement.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Replace EPIRB's hydrostatic release unit or provide evidence of date of installation.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Electrical
Issued 20 May 1998
Resolved
Remove all dead end wiring located thru vsl (port side aft and engine room).
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Provide suitable watertight container in order to properly store all flares.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Provide suitable first aid kit.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Electrical
Issued 20 May 1998
Resolved
Provide suitable battery covers for all batteries located at the engine room.
Condition: Unknown
Due 10 June 1998
Resolved 28 June 1998
Electrical
Issued 20 May 1998
Resolved
Provide suitable covers for all electrical switch boxes and distribution panels.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Navigation
Issued 20 May 1998
Resolved
Provide suitable marine grade bulb for stern light (vice regular car bulb).
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Accommodation/Occupational Safety
Issued 20 May 1998
Resolved
Provide suitable MSD arrangement and replace inoperable valve leading to MSD tank.
Condition: Unknown
Due 10 June 1998
Resolved 28 June 1998
Lifesaving
Issued 20 May 1998
Resolved
Provide suitable emergency lighting for accomodation space, prior to operating with overnight passengers.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Properly replace/repair stb side lifefloat. Vsl limited to not more than 3miles from shore until discrepancy is corrected.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Fire Fighting
Issued 21 May 1997
Resolved
Renew B-II brackets, main accomodation space, engine room & CO2._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Accommodation/Occupational Safety
Issued 21 May 1997
Resolved
Install public address system through vessel.
Condition: Unknown
Due 21 June 1997
Resolved 10 July 1997
Documentation
Issued 21 May 1997
Resolved
Provide current CFR.
Condition: Unknown
Due 13 June 1997
Resolved 13 June 1997
Lifesaving
Issued 21 May 1997
Resolved
Provide 8 additional PFD lights.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Electrical
Issued 21 May 1997
Resolved
Renew P/A speaker aft deck-support.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Electrical
Issued 21 May 1997
Resolved
Provide emergency lighting in fwd accomadation space.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Electrical
Issued 29 May 1996
Resolved
PROVIDE AUTOMATED EMERGENCY LIGHTING IN BERTHING AREA.
Condition: Unknown
Due 29 May 1996
Resolved 29 May 1996
Navigation
Issued 29 May 1996
Resolved
PROVIDE A 200MM OR GREATER BELL.
Condition: Unknown
Due 8 June 1996
Resolved 8 June 1996
Lifesaving
Issued 29 May 1996
Resolved
REPAIR LIFE FLOATS AS PER INSTRUCTIONS.
Condition: Unknown
Due 8 June 1996
Resolved 8 June 1996
Electrical
Issued 29 May 1996
Resolved
PROVIDE COVER FOR PORT GEN CONNECTION BOX AND REMOVE ALL UNUSED WIRING FROMVESSEL.
Condition: Unknown
Due 8 June 1996
Resolved 8 June 1996
Unknown
Issued 29 May 1996
Resolved
COMPLY WITH DRUG TESTING PROGRAM, 46 CFR, PART 16.
Condition: Unknown
Due 5 June 1996
Resolved 10 June 1996
Construction/Loadline
Issued 5 April 1996
Resolved
Complete permanent repairs to keel.
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Electrical
Issued 14 July 1995
Resolved
Prove proper operation of voltage, amp & frequency meters for both generators.
Condition: Unknown
Due 14 July 1995
Resolved 14 July 1995
Fire Fighting
Issued 30 May 1995
Resolved
Replace stbd. fire hose.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 30 May 1995
Resolved
Label all emergency lights.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 30 May 1995
Resolved
Fix port generator exhaust leak, and water leak near temp. sending unit.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 30 May 1995
Resolved
Prove proper operation of voltage, amp & frequency meters for both generators.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Fire Fighting
Issued 30 May 1995
Resolved
Label fire axe and hang in pilot house.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Engineering
Issued 30 May 1995
Resolved
Rehang and make watertight port main engine raw water ovbd. line.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 30 May 1995
Resolved
Place cover on light switch at top of crews berthing ladder.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Accommodation/Occupational Safety
Issued 30 May 1995
Resolved
Label both sides of emergency escape hatch's from both berthing area's IAW 46 CFR 185.30-15.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Lifesaving
Issued 30 May 1995
Resolved
Replace stbd. aft ring buoy.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Fire Fighting
Issued 30 May 1995
Resolved
Have discharged B-II fire extinguisher from crews berthing serviced.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Lifesaving
Issued 30 May 1995
Resolved
Provide 6 red, 6 orange visual distress signals with current service life.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 3 August 1994
Resolved
DEMONSTRATE PROPER OPERATION OF STARBOARD GENERATOR.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Electrical
Issued 3 August 1994
Resolved
WIRE GENERATORS IN ACCORDANCE WITH GOOD MARINE PRACTICE ADN 46 CFR 182.
Condition: Unknown
Due 3 August 1994
Resolved 3 August 1994
Electrical
Issued 31 May 1994
Resolved
Repair port battery box in the engine room.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Electrical
Issued 31 May 1994
Resolved
Demonstrate proper operation of both ship service generators.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Accommodation/Occupational Safety
Issued 2 June 1993
Resolved
REPAIR FRACTURED UPPER STEP ON LADDER LEADING INTO AFTER BERTHING.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Accommodation/Occupational Safety
Issued 2 June 1993
Resolved
REPAIR / REINFORCE ALL STEPS ON LADDER LEADING INTO FORWARD BERTHING.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Engineering
Issued 2 June 1993
Resolved
REPAIR LEAK ON THE STARBOARD SIDE GENERATOR EXHAUST PIPE.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 2 June 1993
Resolved
REPLACE 11 OUTDATED LIGHTS ON LIFEJACKETS.
Condition: Unknown
Due 3 July 1993
Resolved 8 June 1993
Documentation
Issued 12 February 1993
Resolved
COMPLETE THE WORK LIST ITEMS ISSUED ON 11FEB93.
Condition: Unknown
Due 2 March 1993
Resolved 2 March 1993
Electrical
Issued 15 July 1988
Resolved
PROVIDE SHOCK PROOF PLATFORM IN FRONT OF MAIN SWITCHBOARD.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Electrical
Issued 15 July 1988
Resolved
REPLACE MISSING BATTERY BOX COVERS
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
REPLACE FIRE PUMP PRESSURE GAUGE.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Fire Fighting
Issued 15 July 1988
Resolved
REPLACE GASKET SEAL TO FIRE PUMP.
Condition: Unknown
Due 15 July 1988
Resolved 15 July 1988
Construction/Loadline
Issued 16 June 1988
Resolved
GRIND AND REGLASS LOWER DECK TO HULL JOINT IN FOREPEAK COMPARTMENT.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 16 June 1988
Resolved
GRIND AND REGLASS LOWER DECK TO HULL JOINT IN #2 COMPARTMENT OR REPLACE DECK AND SUPPORT WITH A DECK CLAMP.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Accommodation/Occupational Safety
Issued 16 June 1988
Resolved
REWELD ALL FRACTURED WELDS ON SPIRAL STAIRCASE TO #2 COMPARTMENT. STIFFEN TOP STEP IF NECESSARY.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Accommodation/Occupational Safety
Issued 16 June 1988
Resolved
REWELD ALL FRACTURED WELDS ON SPIRAL STAIRCASE TO #3 COMPARTMENT.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Engineering
Issued 16 June 1988
Resolved
RENEW ENGINE COOLING PIPING ON ALL MAIN ENGINES FROM SEA VALVES TO HOSES.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 16 June 1988
Resolved
INSTALL KEEPER CHAIN ON LAZARETTE HATCH.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 16 June 1988
Resolved
PROVIDE KEEPER CHAIN FOR FOREPEAK HATCH.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Construction/Loadline
Issued 16 June 1988
Resolved
RENEW GASKET ON FOREPEAK HATCH.
Condition: Unknown
Due 16 June 1988
Resolved 16 June 1988
Engineering
Issued 15 July 1987
Resolved
REPAIR LEAK IN PORT GENERATOR EXHAUST LINE IN WAY OF AFT ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Navigation
Issued 15 July 1987
Resolved
OBTAIN CURRENT EDITIONS OF LIGHT LIST, SUBCHAPTER T, AND TIDE TABLES.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Engineering
Issued 15 July 1987
Resolved
INSTALL FLAME SHIELDS ON RACOR FUEL FILTERS FOR BOTH GENERATORS.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Accommodation/Occupational Safety
Issued 15 July 1987
Resolved
INSTALL FIRE RESISTANT ENGINE ROOM VENT.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Engineering
Issued 15 July 1987
Resolved
REPAIR LEAK ON STBD. GENERATOR EXHAUST LINE IN LAZARETTE IN WAY OF TRANSOM PENETRATION.
Condition: Unknown
Due 15 July 1987
Resolved 15 July 1987
Lifesaving
Issued 18 July 1986
Resolved
MOUNT PRIMARY LIFESAVING EQUIPMENT FOR 50 PERSONS
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Lifesaving
Issued 18 July 1986
Resolved
FIT ALL PFD'S WITH PFD LIGHTS
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Documentation
Issued 18 July 1986
Resolved
POST STABILITY LETTER ON VESSEL
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Navigation
Issued 18 July 1986
Resolved
MOUNT EPIRB IN FLOAT FREE POSITION.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986