Records from 2016 to 2025. Most recent: inspection, 17 September 2025.
Inspection history · 15
17 September 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8235963
17 September 2024
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7999447
12 June 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7942712
29 June 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7490328
31 May 2022
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7464477
29 March 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7420560
5 August 2021
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7277632
31 August 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7047418
2 June 2020
Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6965944
16 April 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6939993
26 June 2019
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6724964
7 May 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6407887
18 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6393177
6 June 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6163597
24 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5885074
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock.
Multiple instances of dead-end wiring were observed on board, such as: the second deck battery box, engine room, and second compartment.
Openings in the breaker box on board were observed and need to be covered.
The electrical outlet in the engine room was observed
without a cover.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: All loose wiring and outlet covers closed and sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
A pinhole leak was observed on the starboard main engine wand was leaking oil.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Leaking line replace and tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 17 September 2024
Resolved
Water for cooling the exhaust pipe, other than a vertical exhaust, must be injected into the exhaust system as near to the engine manifold as practicable. The water must pass through the entire length of the exhaust pipe.
An exhaust cooling water leak was observed on the starboard main engine.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Leaks repaired, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2024
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor.
Grounding wires connected to fuel shutoff valves were improperly installed.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Grounding wires replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 September 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operational test of all overboard discharge and intake valves and watertight bulkhead pipe penetration valves.
@ overboard discharges were observed on the starboard side bulkhead of the engine room to be fitted without drains.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Replaced, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 17 September 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
General condition and cleanliness of engine room, including machinery parts, surfaces, and bilges lacked cleanliness.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 October 2024
Resolution: Cleaned, all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 September 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Numerous sections of fiberglass hull and wood framing in the vessels structure were found to with significant wastage, namely in the forward compartment, second and third compartments, engine room, and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Fiberglass repairs completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 September 2024
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve.
The painter must:Have a breaking strength of at least 680 kilograms (1,500 pounds).
A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the name of the manufacturer, lot designation or serial number, approval number, dimensions, and number of persons capacity. Space must be provided for the date, and the identification of the independent laboratory.
Starboard life float was observed to have a hole in the side and a worn/wasted lifeline. Both life floats were without a nameplate.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Nameplates cleaned and legible, lifelines replaced, life float repaired, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2024
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018 or other standard specified by the Commandant.
An adult life jacket must be provided for each person carried on board a vessel.
Numerous life jackets were observed to be in need of new retroreflective tape, and several lifejackets were in need of replacement due to wasted material.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Reflective tape replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 17 September 2024
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails.
Ladders leading to the 2nd deck from the bow and stern were observed to be without a lifeline.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Lifelines installed, ladder cracks welded, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 31 May 2022
Resolved
Replace deck frames and deck plywood, seal collision bulkhead, seal hole on deck port side of ladder and grind water intrusion around STBD side stiffener in fore peak.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 31 May 2022
Resolved
Remove every other ceiling panel for inspectors to asses deck condition.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Clean engine room batteries, engine oil and exhaust leak residue.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2022
Resolved
Replace FRP MDE exhaust pipe.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Repair air vents on fantail. (both sides)
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Replace STBD side inboard steering stop.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 May 2022
Resolved
Clean fuel tank for further inspection.
Action required: 705 - Other - as specified
Resolved 17 September 2024
Resolution: vessel completed credit dry dock on 12JUN2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2021
Resolved
Using non combustable material to bracket the bundled electrical wires just foward of the engines, using a bracket every 24 inches.
Action required: 705 - Other - as specified
Due 10 August 2021
Resolved 10 August 2021
Resolution: Recieved picture evidence of proper bracketing of the wiring in the engine room.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 August 2021
Resolved
Line attached to weak link is tankgled. Untangle line and connect the weak link properly under the spooled line so that the line can pay out properly in an emergency.
Action required: 705 - Other - as specified
Due 10 August 2021
Resolved 10 August 2021
Resolution: Recieved picture evidence of proper arrangement of the weak link and line for the life floats.
Lifesaving › Lifefloat › Painter
Issued 6 June 2017
Resolved
Install a longer painter line, as required, for lifefloats. 46CFR180.137(e)(3).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2017
Resolved 6 June 2017
Resolution: New painter line of adequate length was installed on life floats. Deficiency rectified.
Lifesaving › Lifefloat › Retroreflective Material
Issued 6 June 2017
Resolved
Replace retroreflective tape on lifefloats (02 pieces) with approved type. 46CFR160.027.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 12 June 2017
Resolution: New retroreflective tape put on lifefloat (See photos). Deficiency rectified.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 6 June 2017
Resolved
Replace retroreflective tape on lifejackets with approved type. 46CFR185.604(h).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 12 June 2017
Resolution: New retroreflective tape placed on life jackets (See photos). Deficiency rectified.