Records from 2016 to 2026. Most recent: inspection, 8 January 2026.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 February 2025
Resolved
Renew retro on both the life float and ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 24 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 February 2025
Resolved
Tighten shaft seal has a small leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 24 February 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 February 2025
Resolved
V-berth bilge pump doesn't have a working light indicator. Pump does work.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 March 2025
Resolved 24 February 2025
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 April 2023
Resolved
First aid kit had several expired items. Must replace all expire items to meet requirements listed in 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 May 2023
Resolved 8 May 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 March 2022
Resolved
#2 and #3 high water bilge alarms visual indicators are not working and the #4, aft void neither audible or visual alarm is working. Must make repairs and test to the satisfaction of attending CG Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 March 2022
Resolved 15 March 2022
Resolution: Owner/ Operator submitted video footage of successful testing of all bilge alarms and indicator lights. All cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 March 2021
Resolved
Vessel's suffered a marine casualty with their MDE. Must trouble shoot and make repaires and test to the satisfaction of attending CG marine inspector priot to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 March 2021
Resolved 23 March 2021
Resolution: Owner/ Operator completed repairs to MDE. Both heads were shaved and refurbished, in addition to the replacement of the manifold. Conducted sea trails to determine full function of MDE. All found satisfactory after running MDE at cruising RPM.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 January 2021
Resolved
NAV lights are not working. New NAV lights are on order. Install and test all NAV lights prior to carrying passengers.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 28 January 2021
Resolved 18 January 2021
Resolution: received video of all NAV ligths working. All SAT
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 January 2021
Resolved
Due to MDE issues, Must conduct Fire and MOB drills after MDE is fixed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 January 2021
Resolution: Conducted MOB and Fire drill, all SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 January 2021
Resolved
MDE wont stay running at higher RPM's. Cause is believed to be sucking air in with the fuel and not getting enough fuel PSI. Trouble shoot and conduct test to satisfaction of CG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2021
Resolved 18 January 2021
Resolution: Found lose hose clamp and fitting on the fuel filter housing. Tighten and tested SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 January 2021
Resolved
Replace dryrotted grab line on life ring buoy and replace throw line with approved CG line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 January 2021
Resolution: Received pictures with new grab line and throw line for life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 13 January 2021
Resolved
Life float is faded pretty bad. Need to repaint with international orange approved paint for life floats and label with passenger count and vessel name
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 January 2021
Resolution: Received picture of life float completely painted and labeled with vessels name and passenger count. all SAT
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 January 2021
Resolved
Label life jacket stowage for both adult and child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 January 2021
Resolution: Received pictures with proper labeling of life jackets.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 13 January 2021
Resolved
Install Emergency broadcast placard and all other required placards.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 January 2021
Resolution: Received pictures with all required placards posted in cabin.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 13 January 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 12 May 2021
Resolution: Received picture of pre employment drug test completed and passed.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 13 January 2021
Resolved
Alcohol Swabs were expired - Dec 2020. Must replace with new Alcohol swabs and enough to be able to test the entire crew.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2021
Resolved 26 January 2021
Resolution: Received pictures of new Alcohol swabs with the experation date of OCT 2022.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 February 2020
Resolved
Provide properly sized weak-link for Life Float painter, vessel is restricted to operating within 3 nm from shore and no more than 100ft of water.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 February 2020
Resolved
Replace hydrostatic release for EPIRB, found expired
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2020
Resolution: Hydro replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 February 2020
Resolved
Replace batteries in floating waterlights
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 February 2020
Resolution: Replaced batteries
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 February 2020
Resolved
Post sign that states "Official Documents Available Upon Request" letters must be at least 1 inch high
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 February 2020
Resolved
Cover ungrounded terminal on battery in forward compartment and secure tray to vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 February 2020
Resolved
Repair/replace flame screen for fuel tank vent, vent was found missing screen.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 February 2020
Resolved
Provide manufacture specification for normal oil operating pressure for Propulsion Engine (CAT 3208). Oil gauge was maxed out and settled below 100psi while conducting underway drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 February 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 January 2020
Resolved
Vessel must undergo an annual inspection for 2019, vessel anniversary date is 19SEP. Last annual inspection was conducted on 05JUL2018
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2020
Resolution: Annual inspection started
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 January 2020
Resolved
Demonstrate proper operation and closure of raw water engine sea valve. Valve was unable to close all the way during testing.
Action required: 705 - Other - as specified
Resolved 6 February 2020
Resolution: Valve closed properly
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 January 2020
Resolved
Repair/replace gasket on aft deck hatch to maintain watertight integrity, gasket missing near hinge.
Action required: 705 - Other - as specified
Resolved 6 February 2020
Resolution: gasket replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 27 January 2020
Resolved
Repair/replace hose on sea valve to pump in lazarette compartment, hose no longer serviceable or permanently cap valve.
Action required: 705 - Other - as specified
Resolved 6 February 2020
Resolution: New hose installed
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 July 2018
Resolved
Demonstrate proper operation for closing and reopening all supply ducts for engine room, a space protected by a fixed gas extinguishing system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2018
Resolution: Ventilation shutdown system properly working.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 18 July 2018
Resolved
Provide that Captain has successfully completed a chemical test for dangerous drugs for current marine employer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2018
Resolution: Captain and crew enrolled into consortium.
01 - Certificates & Documentation › 013 - Documents › Shipboard working arrangements
Issued 18 July 2018
Resolved
Provide written company drug and alcohol policy, detailing companies position regarding their expectations of their crew members with regards to drug and alcohol testing and actions to be taken as a result of drug testing results. Utilize Employers Drug Testing Guidance provided by USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2018
Resolution: Written plan in place for company.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 18 July 2018
Resolved
Provide valid FCC Safety Certificate for vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: FCC documents on board.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 July 2018
Resolved
Provide valid FCC operator permit for crew member.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Operator has FCC permit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2018
Resolved
Provide working lights for all PFDs. Vessel may choose to alter route to limited coastwise to eliminate need for lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessels COI reduced to L/C as per owners request.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 18 July 2018
Resolved
Vessel must carry an first-aid kit with the contents as per 46CFR160.041 and with instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Proper first aid kit on board.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 July 2018
Resolved
Vessel must carry the following adequate and up-to-date publications for the intended area of operation. U.S. Coast Pilot [name withheld] List, Tide Tables, and Current tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: All up to date publications on board.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 July 2018
Resolved
Bilge high level alarm in fuel tank space shall be lowered to provide notification that a high level of water is in space before electrical/essential systems are flooded.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2018
Resolution: High level indicators lowered to acceptable level.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 July 2018
Resolved
Clean main steering gear ram mounting bracket to visually check amount of wastage and verify strength and integrity of mount.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Bracket cleaned and treated to preserve, special note added to keep eye on bracket with the possibility of replacing at next credit DD.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 July 2018
Resolved
Battery in forward compartment must be mounted in a tray resistant to damage by the electrolyte.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Battery removed from compartment.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 July 2018
Resolved
Vessel must be provided with at least two portable lights, one of those must be stowed at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: 2 portable lights on board.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 18 July 2018
Resolved
Remove all dead-end wiring from vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2018
Resolution: All dead-end wiring removed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 July 2018
Resolved
Vessel name must be marked on both port and starboard bow.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 August 2018
Resolution: Vessel properly marked with vessel name at all locations.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 July 2018
Resolved
Conduct man over board and fire drills with attending USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2018
Resolution: MOB and Fire drill conducted satisfactorily.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 March 2018
Resolved
Complete required dry-dock examination prior to carrying passengers to the satisfaction of the attending marine inspector IAW 46 CFR 176.600
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 March 2018
Resolved 9 March 2018
Resolution: Deficiency cleared, credited drydock.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 September 2017
Resolved
Vessel had expired radion telephone cert. 46 CFR 184.502
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 September 2017
Resolved 19 September 2017
Resolution: Radio surveyor issued new certificate.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 19 September 2017
Resolved
fuel vent pipe not electronically bonded. 46 CFR 182.450
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 19 September 2017
Resolution: Corrected same day. Mechanice made bonding connections.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 September 2017
Resolved
Filly pipe not electronically bonded. 46 CFR 182.445
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 19 September 2017
Resolution: Corrected. Mechanic bonded fill pipe correctly.
Engineering › Steering Gear System › Hydraulic Hose
Issued 19 September 2017
Resolved
Weeping oberserved on hose connections in fuel tank compartment. 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 19 September 2017
Resolution: Mechanic diagnosed leak and the connection into the auto pilot was leaking. repaired.
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 19 September 2017
Resolved
Vessel did not have instructions on how to change over to aux steering. 46 CFR 182.610
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 September 2017
Resolved 20 September 2017
Resolution: Owner showed prrof of written instruction and are now posted in the wheelhouse.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017
Resolved
Ammonia inhalants were expired. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 20 September 2017
Resolution: Evidence provided that ammonia is on order.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 March 2016
Resolved
EPIRB hydrostatic release expired in FEB2016. Vessel is restricted from operating beyond 3 miles. 46 CFR 180.64
Action required: 705 - Other - as specified
Due 14 March 2016
Resolved 7 March 2016
Resolution: Replaced new-in-kind.