MAURY USCG vessel records Sign in
← All vessels

WILLIAM D. EVANS

WILLIAM D. EVANS is a 1986 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1986, most recently in January 2026, along with 163 deficiencies and 1 casualty investigation in 2009.

Records from 1986 to 2026. Most recent: inspection, 23 January 2026.

Built
1986
Last inspected
23 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTT2122
271427
Flag
UNITED STATES
367138330
Maury page id
psix-271427

Inspections, by type

…with no type recorded12
Years with a record 39 calendar years (1986–2026)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)96.0 ft × 36.0 ft × 8.1 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSAN DIEGO SHIPBUILDING AND REPAIR INC · CHULA VISTA, CA, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WTT2122MMSI 367138330 · active · compulsorily equipped · granted 2 September 2016, expires 18 October 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 95

23 January 2026 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8302428
13 August 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8198378
30 July 2025 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8198374
4 June 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8152266
20 December 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8057311
7 August 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7977500
29 January 2024 In-Service Inspection · Excursion Permit · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7858218
1 June 2023 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7702094
16 December 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7610297
23 June 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7485166
16 May 2022 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7451933
11 January 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7378462
1 October 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7324973
9 September 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7308310
25 August 2020 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7042280
14 January 2020 Deficiency Check · Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6888855
20 August 2019 Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6788243
13 August 2018 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6511205
17 January 2018 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6339053
1 June 2017 MTSA/ISPS Verification · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6156178
7 September 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5994896
7 January 2016 Hull Examination · Administrative Inspection · Construction Oversight · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5793040
9 September 2015 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5718579
11 June 2012 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4341128
6 January 2012 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4219725
29 September 2011 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4157195
6 September 2011 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4048173
7 September 2010 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3779350
20 December 2009 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4153236
18 December 2009 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3652629
29 October 2008 DAPI Audit · MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3352122
19 March 2008 Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3161781
30 January 2008 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3139336
26 June 2007 COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2945197
26 September 2006 Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2728311
17 February 2006 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2601895
18 January 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2568755
28 September 2005 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2480993
28 June 2005 MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2406856
7 August 2004 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2250027
27 July 2004 Annual Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2098185
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978253
9 December 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1961327
17 July 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1848998
2 July 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1833234
12 June 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1629970
21 December 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1473629
20 October 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1370367
11 January 2000 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1404898
21 September 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1338577
21 July 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 777904
7 July 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1429175
15 October 1998 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1392999
22 July 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1395035
19 March 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 778014
22 January 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372125
12 September 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1396801
10 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2457
8 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213193
12 July 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1437119
19 January 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1377616
29 June 1995 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1357235
7 July 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1428361
8 March 1994 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 854597
20 January 1994 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 851169
18 August 1993 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 843760
30 July 1993 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 847179
15 July 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1464471
10 May 1993 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1138991
27 July 1992 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1268772
19 February 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1258816
12 November 1991 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 941332
5 August 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1245808
21 June 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 901271
20 June 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900763
20 May 1991 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 915291
20 August 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 921504
13 August 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 907991
16 January 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 929439
14 September 1989 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1349227
5 September 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1043957
28 August 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1033206
22 July 1989 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1210234
27 September 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1352588
20 September 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1350210
16 September 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1351154
6 September 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1041617
13 June 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1199587
23 March 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 985387
22 February 1988 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1330009
28 December 1987 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1006502
1 December 1987 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1028714
20 October 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1323510
8 September 1987 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1311211
19 September 1986 Credit Drydock · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1330165

Deficiency record · 163

18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 22 August 2025 Resolved
As part of a reasonable cause drug testing program established pursuant to this part, employers may test for drugs in addition to those specified in this part only with approval granted by the Coast Guard under 49 CFR part 40 and for substances for which the Department of Health and Human Services has established an approved testing protocol and positive threshold. A full DAPI audit must be conducted. 46 CFR 16.101 (c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2025
Resolved 11 September 2025
Resolution: Full DAPI audit was successfully conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2025 Resolved
STBD rudder compartment bilge suction failed to remove water from space, prove proper operation of system. 46 CFR 119.510
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 August 2025
Resolution: Vessel proved proper operation of the STBD rudder bilge system.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 13 August 2025 Resolved
As part of a reasonable cause drug testing program established pursuant to this part, employers may test for drugs in addition to those specified in this part only with approval granted by the Coast Guard under 49 CFR part 40 and for substances for which the Department of Health and Human Services has established an approved testing protocol and positive threshold. MI discovered that the vessel does not have a drug and alcohol program in place.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2025
Resolution: O/O supplied information of their DAPI to allow clearing this deficiency. Full audit will be rescheduled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 August 2025 Resolved
Stbd rudder compartment hatch found with wasted steel knife edge and deteriorated gasket, repair both. 46 CFR 116.1160
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 5 September 2025
Resolution: Witnessed satisfactory final weld test for crop and renew.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Main deck forward bar found with daisy chained extension cords to bar cooler, provide dedicated receptacle. 46 CFR 120.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: At the fwd main bar the extension cord was removed, and a dedicated receptacle was installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Electrical or interlock devices shall be provided to prevent generators from paralleling and shore power and generators being energized simultaneously. Prove that electrical system can prevent both occurrences. 46 CFR 120.390 / 120.322
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 2 October 2025
Resolution: Received satisfactory report.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Port engine room bilge alarm switch wired with exposed wire nuts. Provide junction box for wire nuts or crimp connections and make watertight. 46 CFR 120.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Port engine room bilge alarm wires are no longer exposed, and the wire nuts were removed.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 13 August 2025 Resolved
Port rudder compartment bilge suction found with several inches of hydraulic oil. Remove oil and clean bilges. 46 CFR 115.830
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Port rudder bilge was free of hydraulic oil.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 13 August 2025 Resolved
Port rudder compartment hydraulic steering piping found unsupported in numerous areas. Provide proper piping supports. 46 CFR 119.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Port rudder compartment hydraulic steering piping is now supported.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2025 Resolved
Main engine exhaust piping in port rudder compartment found severely corroded and wet. Needle-gun underside of piping to prove integrity.46 CFR 119.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Main engine exhaust pipe in the port aft compartment was needle gunned and cleaned.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Upper deck stbd equipment locker found with electrical hazards on aft bulkhead. Properly wire junction box and wiring. 46 CFR 120.200.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Upper deck stbd equipment locker now has properly wired junction box and wiring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 August 2025 Resolved
A vessel of more than 65 feet must carry 3 ring-buoy in accordance with 46 CFR 160.050. All ring buoys onboard had lines that were deteriorated. Remove all lines/ring buoys and attached lines and replace with at least 3. 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Three ring life buoys were renewed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Second deck bar was found with daisy chained surge protectors from one outlet. Hard wire in power outlet devices and remove surge protector. 46 CFR 120.200.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Surge protectors from the second deck bar were removed and power outlets installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Engine room workroom was found with permanent installed power tools plugged into surge protector daisy chain. Remove daisy chain and hard wire in equipment. 46 CFR 120.200.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Surge protectors from the engine room workroom were removed and power outlets installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Remove electrical cable on work room. 46 CFR 120.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Electrical cable was removed from work room.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Replace junction box in storage room on port side. 46 CFR 120.200.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: New junction box was installed in port storage room.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Electrical
Issued 13 August 2025 Resolved
Replace covers for all refrigeration units to conceal wires with covers that can be affixed and not just resting on the unit. Mount all panels, two were found resting next to the unit. 46 CFR 120.200.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: Covers were installed on all refrigeration units.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 August 2025 Resolved
Watertight door to port engine was found ajar. Repair door to ensure rapid and ease of closure. 46 CFR 122.330 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2025
Resolved 22 August 2025
Resolution: New hinge pins were installed on the watertight door in port engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 August 2025 Resolved
Vessel completed a propulsion repower of both main engines in 2023/2024, the throttle controls were upgraded to electronic at the same time. Submit QFA / DVTP to USCG MSC provided by the throttle control manufacture. Upon approval from MSC, schedule operational testing. 46 CFR 121.620.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 24 September 2025
Resolution: Received DVTPs and QFAs for the engines. All Sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 August 2024 Resolved
Vessel operator was unable to demonstrate a test of the vessel's bilge alarms. Conduct a satisfactory test of the bilge alarms in the presence of a USCG marine inspector. Hourly rounds of the bilges protected by these bilge alarms must be made while the vessel is underway and/or has passengers on board. These rounds must be logged in the vessel's log book. Cite: 46 CFR 182.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2024
Resolved 23 September 2024
Resolution: Witnessed satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2024 Resolved
Pressure vessels must be tested and inspected in accordance with part 61, subpart 61.10, of this chapter. Vessel has a hydro-pneumatic water/air tank in the engine room that is past due for internal inspection, and the data plate was found to be painted over and illegible. Remove paint from data plate and conduct hydrostatic pressure test of the tank at 125% max allowable working pressure (MAWP). Bench test the pressure vessel's relief valve in the presence of a USCG marine inspector to demonstrate that it operates at its set limit. To be rectified by 07 September 2024. Cite: 46 CFR 176.812 & 46 CFR 61.10-5(d)&(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 September 2024
Resolved 30 July 2025
Resolution: Receiver removed from COI, set at 83. Used for Potable water pressure.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 29 January 2024 Resolved
Identified two sections of bottom shell stiffeners in the port engine space and in space adjacent to stbd fresh water tank. Must crop and renew to satisfaction of attending CG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 20 May 2024
Resolution: Bottom shell stiffners cropped and renewed
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 January 2024 Resolved
Identified significant wastage in bottom shell in port void space. Must conduct spot gauge of bottom shell under void and CHT space. Must crop/renew sections indicating greater than twenty-five (25) percent wastage
Action required: 705 - Other - as specified
Resolved 20 May 2024
Resolution: Port bottom shell cropped and renewed
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2023 Resolved
02 daisy chained power strips were found connected to an extension cord in the aft area of the wheel house. Provide dedicated receptacles for all required equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 13 July 2023
Resolution: Daisy chained wires removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 1 June 2023 Resolved
The port engine room water tight door was found out of adjustment and difficult to open / close. Make adjustments to WTD so it can be operated easily. To be rectified by next dry docking.
Action required: 705 - Other - as specified
Due 1 July 2023
Resolved 7 August 2024
Resolution: Witnessed satisfactory test of door.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 June 2023 Resolved
The starboard engine room bilge float switch was found un-secured with a broken bracket. Properly mount the bilge alarm float switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2023
Resolved 13 July 2023
Resolution: Float switch was properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 June 2023 Resolved
The hot water heater in the galley was found with an un-secured disconnect switch. Properly mount the disconnect switch and permanently seal the cable penetrations leading into it.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 13 July 2023
Resolution: Switch was properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2022 Resolved
While underway with passengers vessel experience a loss of its primary generator and main propulsion controls. Provide repair proposal and performance diagnostics to determine cause to [email withheld].
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 29 June 2022
Resolution: Generator circuit breaker and controller replaced on both generators. Two hour operational load test; ALL SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 16 May 2022 Resolved
Engine room emergency escape found to have inadequate labeling. All escape hatches and other emergency exits are required to be marked on both sides in clearly legible letters of 2 inches high.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 July 2022
Resolution: Installed new emergency escape placards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2022 Resolved
Junction box in pump room found to have missing faceplate allowing for exposed open wires. Replace face plate and properly secure wires inside junction box.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 16 June 2022
Resolution: Installed new junction box.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2022 Resolved
Emergency escape signs do not illuminate when power is lost. Provide emergency escape lighting during loss of power.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 16 June 2022
Resolution: Repaired lights to illuminate during power loss.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 16 May 2022 Resolved
VHF DSC radio found to be installed without GPS coordinates programmed. Program VHF DSC radio to include MMSI number and GPS information.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2022
Resolved 16 June 2022
Resolution: Programmed radio to include MMSI and GPS coordinates.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2022 Resolved
Ground detection system IWO Port engine room found to be inoperable. System is required to provide adequate indication of circuit status.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2022
Resolved 16 June 2022
Resolution: System repaired to show indication of circuit status.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 September 2021 Resolved
Portside engine room fire pump discharge gauge needle broken; replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2021
Resolved 17 September 2021
Resolution: Received Photo's of corrected deficiency. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 September 2021 Resolved
01 Deck Port and STBD side storage utility closet overhead light fixture missing light cover diffuser; Replace missing covers.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2021
Resolved 17 September 2021
Resolution: Received Photo's of corrected deficiency. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2021 Resolved
Engine room STBD side vent fan controllers ( 5-P7, 6-P7, and 7-P7) indicating light covers missing; Replace missing covers.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2021
Resolved 17 September 2021
Resolution: Received Photo's of corrected deficiency. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 9 September 2021 Resolved
Galley Beverage walk-in reefer overhead light fixture inoperative. Repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2021
Resolved 17 September 2021
Resolution: Received Photo's of corrected deficiency. [name withheld].
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2021 Resolved
Galley Beverage walk-in reefer condenser control cover hanging from wiring and not properly secured to unit. Re-install cover
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2021
Resolved 17 September 2021
Resolution: Received Photo's of corrected deficiency. [name withheld].
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 September 2021 Resolved
VSL FAILED TO UNDERGO THE REQUIRED ANNUAL INSPECTION BEFORE THE 3 MONTH WINDOW EXPIRED ( 01 SEPTEMBER 2021 ) VSL SHALL NOT OPERATE WITH PASSENGERS ONBOARD UNTIL THE COMPLETION OF THE REQUIRED ANNUAL INSPECTION.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2021
Resolution: CONDUCTED
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 August 2020 Resolved
Provide spanner wrench at Fire Station #7.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 9 September 2020
Resolution: Vessel operator provided pictures of spanner wrench at Fire Station #7
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 August 2020 Resolved
Replace fire extinguisher brackets as identified with USCG approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 9 September 2020
Resolution: Vessel operator provided pictures of fire extinguisher brackets as identified with USCG approved type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 August 2020 Resolved
Properly label life jacket storage below pilot house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 September 2020
Resolved 9 September 2020
Resolution: Vessel operator provides pictures of properly labeled life jacket storage below pilot house.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2020 Resolved
Properly mount galley bilge suction pipe. Due 29Feb2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 21 February 2020
Resolution: Pipe was properly mounted.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2020 Resolved
Install bilge strainer on galley bilge suction line. Due 29Feb2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 21 February 2020
Resolution: Bilge strainer was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 January 2020 Resolved
Provide pressure vessel measurements (Length, height, circumference) for 2 air receivers in machinery space. Due 29Feb2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 21 February 2020
Resolution: Pressure vessel was hydrostatically tested at 125% of MAWP.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2020 Resolved
Drain and open-up large pressure vessel for internal inspection. Due 29Feb2020.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 21 February 2020
Resolution: Pressure vessel was hydrostatically tested at 125% of MAWP.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 14 January 2020 Resolved
Crop and renew wasted sewage line in forward machinery space located in way of water pressure tank. Due 29Feb2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 6 March 2020
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 14 January 2020 Resolved
Provide repair plan for wasted deck rails. Due 29Feb2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 February 2020
Resolved 21 February 2020
Resolution: Deck rails were re-welded.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 20 August 2019 Resolved
VESSEL MUST MAINTAIN HIGH LEVEL ALARM INDICATORS IN ENGINE SPACE. AUDIBLE BILGE ALARM INDICATOR IN PORT ENGINE SPACE NOT FUNCTIONING. MUST RECTIFY DEFICIENCY TO THE SATISFACTION OF USCG MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 17 September 2019
Resolution: CG Inspectors witnessed high level alarm operation
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 August 2019 Resolved
VESSEL MUST HAVE ELECTRICAL WIRING IN ENGINE SPACE IN ACCORDANCE WITH THE PROPER SAFETY STANDARDS. WIRING TO THE BATTERY CHARGER DOES NOT MEET THE SAFETY STANDARDS IN ACCORDANCE WITH NATIONAL/INTERNATIONAL STANDARDS. VESSEL OPERATOR MUST CHANGE WIRING TO THE SATISFACTION OF USCG MARINE INSPECTOR.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 17 September 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 20 August 2019 Resolved
VESSEL MUST MAINTAIN STRUCTURAL INTEGRITY. COOLANT WAS DISCOVERED LEAKING FROM KEEL COOLER TO ENGINE ROOM BILGE SPACE THROUGH A CRACKED SEAM. MUST REPAIR AND TEST SEAM FOR INTEGRITY TO THE SATISFACTION OF USCG MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 September 2019
Resolved 17 September 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 13 August 2018 Resolved
Provide working watertight indicator light at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 23 August 2018
Resolution: Light remains on when doors are closed and turns off when a door is open.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 August 2018 Resolved
Replace the 06 identified broken light covers in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 August 2018
Resolved 23 August 2018
Resolution: Vsl replaced all lighting fixtures in engine room.
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 1 June 2017 Resolved
Make emergency lighting in galley operational.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 13 July 2017
Resolution: New emergency lighting installed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 June 2017 Resolved
Remove dead end wires under helm.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 1 June 2017
Resolution: Wires capped.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 June 2017 Resolved
Provide light cover in tonnage space.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 15 June 2017
Resolution: Light cover installed.
Electrical › Electrical Distribution System (service) › Ground Indicator
Issued 1 June 2017 Resolved
Beer cooler ground on 22 circut. Fix to make ground go away.
Action required: 705 - Other - as specified
Due 1 July 2017
Resolved 15 June 2017
Resolution: Ground repaired.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 September 2015 Resolved
Provide proper markingds for PFD storage.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 5 October 2015
Resolution: proper markingds for PFD storage has been provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 September 2015 Resolved
Provide updates to Coast Guard Light List and Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 October 2015
Resolved 5 October 2015
Resolution: Updates to Coast Guard Light List and Coast Pilot have been obtained.
Electrical › Electric Supply System (service) › Cable
Issued 11 June 2012 Resolved
Determine & repair electrical ground on phase two of the 120V switchboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 26 June 2012
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 June 2012 Resolved
Demonstrate proper operation of 60 cycles frequency meter on main switchboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2012
Resolved 26 June 2012
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 6 September 2011 Resolved
Provide station bill IAW 46CFR185.514
Action required: 705 - Other - as specified
Due 6 October 2011
Resolved 29 September 2011
Navigation › Piloting/Steering › Marine Charts
Issued 7 September 2010 Resolved
Provide updated charts or correct to date.
Action required: 705 - Other - as specified
Due 7 October 2010
Resolved 17 September 2010
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2010 Resolved
Provide wire splint, aspirin, and ammonia inhalants
Action required: 705 - Other - as specified
Due 7 October 2010
Resolved 17 September 2010
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 September 2010 Resolved
Display all pages of the COI.
Due 7 October 2010
Resolved 7 September 2010
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 7 September 2010 Resolved
Cap port side piping to shaft cooling or properly install cooling pump and piping.
Action required: 705 - Other - as specified
Due 7 October 2010
Resolved 17 September 2010
Fire Fighting › Fire Hoses › Length
Issued 29 October 2008 Resolved
Provide 01 75' fire hose on upper deck to provide full coverage of entire deck.
Due 29 October 2008
Resolved 31 October 2008
Resolution: Corrected
Engineering › Fuel Oil Service System › Filter
Issued 29 October 2008 Resolved
Provide fuel filter on all MDE and Gensets with fitted flame shield bowls.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2008
Resolved 31 October 2008
Resolution: Corrected
Stability › Unintentional Flooding › General
Issued 29 October 2008 Resolved
Address loose rubber gasket on stbd rudder room hatch.
Due 31 October 2008
Resolved 31 October 2008
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 29 October 2008 Resolved
Replace plastic deck grates in tonnage space with non-combustible grates. ensure all grates are well supported.
Due 14 November 2008
Resolved 14 November 2008
Resolution: Corrected
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 29 October 2008 Resolved
Provide alcohol test swabs for each crewmember.
Due 31 October 2008
Resolved 31 October 2008
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 29 October 2008 Resolved
Provide 65 Adult lifejackets under stiching repair.
Due 31 October 2008
Resolved 31 October 2008
Resolution: Corrected
Construction/Loadline › Penetrations › Pipe Flange
Issued 19 March 2008 Resolved
Replace fuel piping from tank to valve.
Action required: 705 - Other - as specified
Resolved 4 April 2008
Resolution: Fuel pipe was renewed
Construction/Loadline › Structures › Deck Plating
Issued 19 March 2008 Resolved
Replace deck plating under bar area, this area is the fuel tank: aprox area is 14" x 4'
Action required: 705 - Other - as specified
Resolved 8 April 2008
Resolution: Received reports on air test, test satisfactory.
Construction/Loadline › Structures › Deck Plating
Issued 19 March 2008 Resolved
Neddle gun and chip deck plating for inspection in the ballast tanks
Action required: 705 - Other - as specified
Resolved 4 April 2008
Resolution: Area was neddled gun and inspected and then paint, satisfactory
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 January 2008 Resolved
Vessel restricted from passenger operations until credit hull (dry-dock) examination completed. Due date was 18JAN08.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2008
Resolved 4 April 2008
Resolution: Credit drydock given this date
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 26 June 2007 Resolved
Provide copy of MIS report that was submitted to the USCG for drug testing during 2006.
Due 20 July 2007
Resolved 25 July 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 26 June 2007 Resolved
Repair port side fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2007
Resolved 28 June 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 26 June 2007 Resolved
Start conducting and logging abandon vsl drills.
Due 20 July 2007
Resolved 19 July 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 June 2007 Resolved
Provide currect Coast Pilot or excerpts for areas transited.
Due 20 July 2007
Resolved 19 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 June 2007 Resolved
Replace (2) adult lifejackets, vsl restricted to NMT 598 total persons until corrected.
Due 20 July 2007
Resolved 19 July 2007
Electrical › Electric Generation Source (service) › Ground Detection
Issued 26 June 2007 Resolved
Repair ground fault indication on "A" phase.
Due 20 July 2007
Resolved 28 June 2007
Fire Fighting › Nozzles › Condition
Issued 26 June 2007 Resolved
Ensure all purpose fire nozzles have safety chain attached.
Due 20 July 2007
Resolved 28 June 2007
Engineering › Pressure Vessel › Marking and Stamping
Issued 26 June 2007 Resolved
Provide information (size, mawp, etc) for two air receivers, one in tonnage space, the other under the pilot house.
Due 20 July 2007
Resolved 2 August 2007
Resolution: Both receivers were determined to be less than 5 cu ft. Both stamped with ASME "U".
Accommodation/Occupational Safety › Potable Water System › General
Issued 26 June 2007 Resolved
Replace safety device on hot water heater.
Due 20 July 2007
Resolved 28 June 2007
Construction/Loadline › Structures › Manhole
Issued 26 June 2007 Resolved
Repair gaskets for P/S steering void hatches.
Due 20 July 2007
Resolved 19 July 2007
Personnel › Training › First Aid/CPR
Issued 26 June 2007 Resolved
Ensure 50% of crew have first aid/CPR training.
Due 20 July 2007
Resolved 19 July 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 26 September 2006 Resolved
Evaluate and submit plan to replace or remove time delay component of fixed fire fighting system.
Action required: 705 - Other - as specified
Due 26 December 2006
Resolved 14 December 2006
Resolution: Replaced time delay. Retest satisfactory
Engineering › Steering Gear System › Piping
Issued 27 July 2004 Resolved
Secure hydralic line over starboard steering gear with metal bands IAW 46cfr176.830
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 3 August 2004
Resolved 5 August 2004
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 7 July 2004 Resolved
Secure electrical distribution box to water heater IAW 46CFR183.200
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 3 August 2004
Resolved 5 August 2004
Electrical › Lighting (emergency)
Issued 2 July 2003 Resolved
Provide adequate emergency lighting IWO "tonnage space" emergency escape scuttle. There is currently no lighting illuminating the ladder or scuttle. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Design Flaw
Due 16 July 2003
Resolved 17 July 2003
Accommodation/Occupational Safety › Ventilation
Issued 2 July 2003 Resolved
Remove engine crankcase breather exhaust piping from ventilation intake and clean oil from ductwork in both engine rooms. Currently piping was installed from the generator and propulsion engine crankcase breathers and directs the crancase oil vapor directly into the powered exhaust vent intake. LEGACY COMPONENT DESC: Powered Exhaust Vent Duct
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2003
Resolution: Operator directed crankcase exhaust into bucket w/ oil sorbant pads to filter oil vapors.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 1 July 2002 Resolved
Clean galley/ service stations to provide a sanitary condition IAW 46 CFR 176.818 LEGACY COMPONENT DESC: Galley/Service Stations
Due 15 July 2002
Resolved 16 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2002 Resolved
Mark emergency escape hatch (main deck) IAW 46 CFR 185.606
Due 15 July 2002
Resolved 16 July 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 1 July 2002 Resolved
Provide Coast Guard approved first aid kits to be visible and immediately available to the crew IAW 46 CFR 160.041 and 184.710 LEGACY COMPONENT DESC: First Aid Kit
Due 15 July 2002
Resolved 16 July 2002
Communications › Radio Communications
Issued 1 July 2002 Resolved
Provide current FCC Safety Certificate IAW 47 CFR 80.903 LEGACY COMPONENT DESC: FCC Safety Certificate
Due 15 July 2002
Resolved 16 July 2002
Operations/Management › Drug and Alcohol Testing
Issued 1 July 2002 Resolved
Provide pre-employment drug testing for new crew hired prior to using for trips for passengers. LEGACY COMPONENT DESC: Testing, Pre-employment
Due 15 July 2002
Resolved 16 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2002 Resolved
Repair railing support (starboard and port side, top deck). Provide both lateral and fore and aft support to the satisfaction of the attending Coast guard Marine Inspector. LEGACY COMPONENT DESC: Deck Rail
Due 15 July 2002
Resolved 16 July 2002
Electrical › Electrical Distribution System (service)
Issued 1 July 2002 Resolved
Permanently mark circuit breaker legend in galley aft panel IAW 46 CFR 163.220. LEGACY COMPONENT DESC: Circuit Breaker
Due 15 July 2002
Resolved 16 July 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 1 July 2002 Resolved
Pump out and clean galley dishwasher sump IAW 46 CFR 177.700 (a) and 176.818. LEGACY COMPONENT DESC: Dishwasher
Due 15 July 2002
Resolved 16 July 2002
Accommodation/Occupational Safety › Cooking Systems
Issued 1 July 2002 Resolved
Install drip shield over galley dishwasher boost heater IAW 46 CFR 183.200 (1) and 183.210 (2).
Due 15 July 2002
Resolved 16 July 2002
Electrical › Electrical Distribution System (service)
Issued 1 July 2002 Resolved
Hard wire winch cable w/ approved cable and hard wire plug IAW 46 CFR 183.340 (d) (2) LEGACY COMPONENT DESC: Cable
Due 15 July 2002
Resolved 16 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 1 July 2002 Resolved
Secure/ repair railing for pilot house both port and starboard side. LEGACY COMPONENT DESC: Deck Rail
Due 15 July 2002
Resolved 16 July 2002
Navigation
Issued 20 October 2001 Resolved
Provide light for magnetic compass.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Accommodation/Occupational Safety
Issued 20 October 2001 Resolved
Replace rotted ballasters on railings.
Condition: Unknown
Due 16 October 2003
Resolved 9 December 2003
Resolution: Vessel personnel repaired many corroded sections of vessel during dry dock.
Navigation
Issued 20 October 2001 Resolved
provide operable anchor light.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Engineering
Issued 20 October 2001 Resolved
Stencil deck near emergy fuel shutoff valves.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Lifesaving
Issued 20 October 2001 Resolved
First aid kit items past expiration date.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Electrical
Issued 20 October 2001 Resolved
Remove or use cable from control box CB11P4.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Accommodation/Occupational Safety
Issued 20 October 2001 Resolved
Provide a valve handle for pump by-pass in AC room.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Accommodation/Occupational Safety
Issued 20 October 2001 Resolved
Perminently mount fresh water pump in AC room.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Construction/Loadline
Issued 20 October 2001 Resolved
Provide properly operating bilge alarms.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Fire Fighting
Issued 20 October 2001 Resolved
Provide relief valves for fire pumps, or prove system press. will not exceed 125PSI.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Fire Fighting
Issued 20 October 2001 Resolved
provide proof of properly operating fixed fire fighting system.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Engineering
Issued 20 October 2001 Resolved
Provide valve handle for SSDG wet exhaust valve.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Electrical
Issued 20 October 2001 Resolved
Provide 24" of clear working space in front of ele. panel #P1 in galley.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Construction/Loadline
Issued 20 October 2001 Resolved
Seal water tight bulkhead penetrations in steering compartments.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Engineering
Issued 20 October 2001 Resolved
Renew lagging on engine exhaust in port steering compartment.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Electrical
Issued 20 October 2001 Resolved
Provide protective cover over workbench light fixture.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Electrical
Issued 20 October 2001 Resolved
provide operable emergy lighting.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Accommodation/Occupational Safety
Issued 20 October 2001 Resolved
Provide locked in alarm or render reefer door unlockable.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Engineering
Issued 20 October 2001 Resolved
Make port bridge wing operating station operable.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Lifesaving
Issued 20 October 2001 Resolved
Provide rescue boat until port bridge wing operating station is operable.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Construction/Loadline
Issued 20 October 2001 Resolved
Provide properly operating bilge pump.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Accommodation/Occupational Safety
Issued 20 October 2001 Resolved
Provide 30X30 mesh screen on MSD tank vents.
Condition: Unknown
Due 20 October 2001
Resolved 20 October 2001
Construction/Loadline
Issued 11 January 2000 Resolved
De-ballast forepeak for internal inspection.
Condition: Unknown
Due 21 March 2000
Resolved 28 March 2000
Lifesaving
Issued 7 July 1999 Resolved
CONDUCT AND LOG CREW TRAINING.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Construction/Loadline
Issued 7 July 1999 Resolved
RENEW BILGE SUCTION SCREENS FOR BOTH PORT AND STBD ENGINE ROOMS.
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Accommodation/Occupational Safety
Issued 7 July 1999 Resolved
SUBMIT REPAIR PLAN FOR BOTH FWD AND AFT STAIR CASE RAILS (STAIRS WHICH LEADFROM 2 DECK TO UPPER DECK).
Condition: Unknown
Due 7 July 1999
Resolved 7 July 1999
Lifesaving
Issued 22 July 1998 Resolved
INSTALL TAG LINE ON SWIMMERS LADDER.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Accommodation/Occupational Safety
Issued 22 July 1998 Resolved
INSTALL MISSING EMERGENCY LIGHT FOR SECOND EXIT OUT OF GALLEY.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Accommodation/Occupational Safety
Issued 22 July 1998 Resolved
CLEAN GALLEY VENTILATION EXHAUST DUCT AND FILTER.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Engineering
Issued 22 July 1998 Resolved
REPAIR ENGINE ROOM ALARM SYSTEM. (NOTE: MARCH 1999 BILGE ALARMS WILL BE REQUIRED. THE SYSTEM MUST HAVE BOTH AUDIO AND VISUAL INDICATORS.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Construction/Loadline
Issued 22 July 1998 Resolved
RENEW GASKETS ON ACCESS COVERS FOR PORT AND STARBOARD RUDDER COMPARTMENTS.
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Documentation
Issued 22 July 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 October 1998
Resolved 22 October 1998
Accommodation/Occupational Safety
Issued 22 January 1998 Resolved
Provide as-built plans/diagrams for A/C inlet piping, also install reach rod or similar closing arrangement per 46 CFR 179.350.
Condition: Unknown
Due 18 February 1998
Resolved 18 February 1998
Lifesaving
Issued 12 September 1997 Resolved
Provide and install lifejacket donning placards. Placards are to be in a conspicuous location(s) regularly accessible and visible to the crew and passengers.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Fire Fighting
Issued 12 July 1996 Resolved
PROPERLY REPAIR THE HALON SYSTEM PRIOR TO CARRYING PASSENGERS OR SAILING.
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Deck/Cargo
Issued 20 January 1994 Resolved
Renew machinery guard on upper deck refrigeration compressor located under stair storage, with acceptable material.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Construction/Loadline
Issued 20 January 1994 Resolved
Renew to original bilge suction screens located in the midship port and starboard ballast tanks.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
Provide documentation/manufacturer information on electrical cabling used for the communications throughout the vessel and reason for degredation.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Accommodation/Occupational Safety
Issued 20 January 1994 Resolved
Provide means of securing emergency escape scuttle in open position, duringuse.
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Electrical
Issued 20 January 1994 Resolved
Renew/provide guard on commutator/brush end of antique generator._x001C_
Condition: Unknown
Due 20 January 1994
Resolved 20 January 1994
Construction/Loadline
Issued 15 July 1993 Resolved
PROPERLY MARK ALL WATERTIGHT DOORS "DOOR TO REMAIN CLOSED WHEN UNDERWAY EXCEPT FOR TRANSIT."
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Electrical
Issued 15 July 1993 Resolved
RENEW "SO" (PORTABLE) CORD USED FOR WIRING #1 AIR CONDITIONING WITH ACCEPTABLE WIRING AS PER 46 CFR 183. TO BE COMPLETED AT NEXT DRYDOCK EXAMINATION BUT NOT LATER THAN 28FEB94.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Fire Fighting
Issued 15 July 1993 Resolved
PROPERLY MARK FIRE AXE.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Electrical
Issued 15 July 1993 Resolved
REMOVE OR PROPERLY DEAD END ( IN A JUNCTION BOX) UNUSED WIRING RUN BETWEEN PORT ENGINE ROOM AND GALLEY. TO BE ACCOMPLISHED AT NEXT DRYDOCK, BUT NO LATER THAN 28FEB94.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Engineering
Issued 13 August 1990 Resolved
PROVIDE A 5-GALLON BUCKET AS A PORTABLE CONTAINMENT DURING FUELING OPERATION.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Accommodation/Occupational Safety
Issued 13 August 1990 Resolved
PROVIDE LABEL MARKING THE EMERGENCY EXIT IN WAY OF THE STARBOARD ENGINE ROOM DOOR.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Accommodation/Occupational Safety
Issued 13 August 1990 Resolved
PROVIDE SAFETY PIN TO THE TWO DECK HATCH COVER HOLDERS IN WAY OF UPPER DECK.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Lifesaving
Issued 13 August 1990 Resolved
PROVIDE LABEL TO THE LIFEJACKET STOWAGE LOCKER ON THE MAIN DECK WITH THE NUMBER OF LIFEJACKETS STOWED.
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Unknown
Issued 28 August 1989 Resolved
REPAIR FIRE CONTROL ALARM SYSTEM.
Condition: Unknown
Due 28 August 1989
Resolved 28 August 1989
Unknown
Issued 6 September 1988 Resolved
STENCIL EMERGENCY EXIT FROM ENGINEROOM.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Unknown
Issued 6 September 1988 Resolved
MARK/LABEL EMERGENCY FUEL OIL SHUT OFF TO PORT AND STARBOARD MAIN ENGINES AND GENERATORS.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Lifesaving
Issued 6 September 1988 Resolved
PROVIDE SEVEN(7) ADDITIONAL ADULT TYPE I PERSONNEL FLOATATION DEVICE.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Unknown
Issued 6 September 1988 Resolved
PROVIDE OIL TRANSFER PROCEDURES. VESSEL CARRIES 10,000 GALLONS OF FUEL OIL ON BOARD.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Fire Fighting
Issued 6 September 1988 Resolved
REPLACE BROKEN PRESSURE GAUGE ON PORT FIRE PUMP.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Fire Fighting
Issued 6 September 1988 Resolved
PROVIDE ONE(1) ADDITIONAL FIRE HOSE (1-1/2" X 50FT) TO REPLACE LEAKING FIRE HOSE.
Condition: Unknown
Due 6 September 1988
Resolved 6 September 1988
Unknown
Issued 13 June 1988 Resolved
INSTALL AN ENCLOSED HOLDING TANK FOR THE GALLEY SINKS' DRAIN AND A PUMP TO DISCHARGE HOLDING TANK TO THE CHT TANK. EXISTING DRAIN PAN CREATE ODOR AND UNSANITARY CONDITION IN THE GALLEY.
Condition: Unknown
Due 13 June 1988
Resolved 13 June 1988
Navigation
Issued 8 September 1987 Resolved
CALIBRATE MAGNETIC COMPASS AND PROVIDE COMPASS DEVIATION TABLE.
Condition: Unknown
Due 8 September 1987
Resolved 8 September 1987
Navigation
Issued 8 September 1987 Resolved
PROVIDE NUMBERS OF OTHER PERSONS IN THE CREW WHEN CARRYING LARGE NUMBERS OF PASSENGERS, IE; BARTENDERS, WAITERS, MUSICIANS, ETC.
Condition: Unknown
Due 8 September 1987
Resolved 8 September 1987
Lifesaving
Issued 8 September 1987 Resolved
REPLACE 2 TORN ADULT PFD'S.
Condition: Unknown
Due 8 September 1987
Resolved 8 September 1987
Navigation
Issued 8 September 1987 Resolved
PAINT RUNNING LIGHT SCREENS FLAT BLACK.
Condition: Unknown
Due 8 September 1987
Resolved 8 September 1987

Casualty record · 1

20 December 2009Routine · role: Involved in a Marine Casualty · activity 4153236
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.