Records from 2013 to 2025. Most recent: inspection, 18 September 2025.
Documentation record
Registered dimensions (L × B × D)28.1 ft × 9.6 ft × 3.6 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL, FL, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
18 September 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8237294
27 February 2025
Deficiency Check · Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8085454
19 January 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7658446
18 August 2021
Drydock Exam · Administrative Inspection · DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7290082
9 March 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6924807
11 June 2019
Type not recorded
No type recorded · Station Panama City · USCG Heartland District (CGD-H) · Activity 6710990
11 February 2019
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6623499
7 May 2018
Annual Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6404253
13 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6390912
16 March 2018
Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6368980
15 May 2017
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6143118
7 March 2016
Administrative Inspection · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5828160
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 25 June 2025
Resolved
Vessel's Category I EPIRB must be registered with NOAA.
Vessel is restricted from operating in the Gulf of America until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 July 2025
Resolution: Received NOAA Cat 1 EPIRB registration for subject vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 June 2025
No resolution recorded
Vessel's DSC radio must be GPS capable with GPS display.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025 — due date passed with no resolution recorded
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 June 2025
No resolution recorded
Vessel's engine compartment hatch to be made watertight by vessel next credit dry dock of 30APR2027.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 June 2025
Resolved
Type I PFD donning placard must be posted. To be corrected by 02JUL2025.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2025
Resolved 18 September 2025
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 June 2025
No resolution recorded
Vessel must be outfitted with an additional 06 day/night distress signals and must be stowed in a watertight container that is marked as required. To be corrected by 02JUL2025.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2025 — due date passed with no resolution recorded
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 25 June 2025
No resolution recorded
Vessel must have onboard a training log to record required drills/training. To be corrected by 02JUL2025.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025
Resolved
Vessel's required machinery gauges at operating station must be functional. To be corrected by 25JUL2025.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025
Resolved 18 September 2025
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 27 February 2025
No resolution recorded
Vessel must be designated as a Marine Employer with consortium and provide Drug and Alcohol Policy, EAP and Supervisor Training. To be corrected by 25JUL2025.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 July 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 February 2019
Resolved
Fireboy fire suppression system over ride test not operating. Have technician troubleshoot and certify operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 February 2019
Resolution: Received and accepted service report; all sat.
Lifesaving › Lifefloat › Serviceable
Issued 7 May 2018
Resolved
Make repair to or replace life float.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: Life float was repaired and repainted.
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2018
Resolved
Replace grab lines on life ring buoy, to include 60ft throw line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: New throw line and grab lines were installed.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 May 2018
Resolved
Provide current tide table chart.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: Current tide table provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 May 2018
Resolved
Provide current coast pilot
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 May 2018
Resolved 14 May 2018
Resolution: Current coast pilot was provided.
Engineering › Lubricating Oil Service System › Hose
Issued 13 April 2018
Resolved
Conduct repairs to transmission lube oil hose and conduct operation test in the presence of a USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2018
Resolved 18 April 2018
Resolution: repairs conducted, operation test all SAT.
Construction/Loadline › Hull › Bottom Plating
Issued 16 March 2018
Resolved
Crop and renew area of fracture fiberglass near the stern tube in the engine room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2018
Resolved 23 March 2018
Resolution: fiberglass repairs were completed; all SAT.
Engineering › Steering Gear System › Rudder
Issued 16 March 2018
Resolved
gouge and reweld area of porosity on the rudder.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2018
Resolved 23 March 2018
Resolution: rudder was qouged and rewelded; all SAT.
Construction/Loadline › Hull › Bracket
Issued 16 March 2018
Resolved
replace 5x stern platform brackets and wood on stern platform.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2018
Resolved 23 March 2018
Resolution: new brackets were installed
Construction/Loadline › Hull › Stiffener
Issued 16 March 2018
Resolved
Replace 1x bolt on stern bracket STBD side.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2018
Resolved 23 March 2018
Resolution: new bolt was installed
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 16 March 2018
Resolved
Replace bolts for 2x bow cleats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2018
Resolved 23 March 2018
Resolution: new bolts were installed.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 May 2017
Resolved
Repair/replace bilge alarm indicating light
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 25 May 2017
Resolution: Vessel repaired light
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 May 2017
Resolved
Conduct satisfactory DAPI audit
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 25 May 2017
Resolution: Vessel completed satisfactory DAPI audit
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 May 2017
Resolved
Provide alcohol testing equipment
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 25 May 2017
Resolution: Vessel provided testing equipment
Stability › Freeing Ports › General
Issued 15 May 2017
Resolved
Clean deck drain
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 25 May 2017
Resolution: Vessel cleaned deck drain
Engineering › Bilge Water Management System › Hose
Issued 15 May 2017
Resolved
Provide portable bilge pump extension hose
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 25 May 2017
Resolution: Vessel provided extension hose
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2017
Resolved
Repair engineroom step and aft deck support
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 25 May 2017
Resolution: Vessel repaired deck and step