Records from 1988 to 1993. Most recent: inspection, 17 September 1993.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 16.0 ft × 12.4 ft
Registered tonnagegross 60 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHARACTER YACHTS · ST. PETERSBURG FL, UNITED STATES · built 1986
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationNo Operation - PM · issued 13 August 1990
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Net Ton
60 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
17 September 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1150835
27 April 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1269387
8 April 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1265005
3 April 1992
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356111
31 March 1992
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354129
11 March 1992
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1257717
16 May 1991
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1230863
30 April 1991
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 916236
19 July 1989
Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 975854
27 September 1988
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 888156
Engineering
Issued 3 April 1992
Resolved
REPLACE ALL SIX WASTED SHROUDS ON THE FORWARD MAST.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Navigation
Issued 3 April 1992
Resolved
REPAIR AND PROVE PROPER OPERATION OF NAVIGATION LIGHTS.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Lifesaving
Issued 3 April 1992
Resolved
PROVIDE SIX CURRENTLY DATED SMOKE FLARES.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Engineering
Issued 3 April 1992
Resolved
PROVIDE A GUARD OVER THE BELTS ON THE MAIN DIESEL ENGINE.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Engineering
Issued 3 April 1992
Resolved
TIGHTEN PACKING ON STUFFING BOX FOR TAIL SHAFT.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Documentation
Issued 3 April 1992
Resolved
PROVIDE PROPOSAL FOR PRE-EMPLOYMENT, POST-INCIDENT, REASONABLE CAUSE, AND RANDOM DRUG TESTING FOR ALL EMPLOYEES.
Condition: Unknown
Due 3 June 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 3 April 1992
Resolved
PROVIDE AN EMERGENCY FUEL SHUT OFF FOR THE GENERATOR WHICH CAN BE SECURED ABOVE THE MAIN DECK.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Lifesaving
Issued 3 April 1992
Resolved
SERVICE BOTH LIFE RAFTS.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Construction/Loadline
Issued 3 April 1992
Resolved
REPAIR OR PROVE PROPER OPERATION OF FORWARD ELECTRIC BILGE PUMP.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Construction/Loadline
Issued 16 May 1991
Resolved
PROVIDE AND INSTALL A SAFETY CHAIN FOR THE CHAIN LOCKER WATERTIGHT SCUTTLE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Fire Fighting
Issued 16 May 1991
Resolved
PROPERLY SECURE PORTABLE FIRE EXTINGUISHERS WITH AN APPROPRIATE EXTINGUISHER BRACKET.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
STENCIL ALL LIFE PRESERVERS WITH THE NAME OF THE VESSEL.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
PROVIDE AND ATTACH A 60FT FLOATING LINE TO THE RING BUOY.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 16 May 1991
Resolved
PROVIDE AND SHOW PROPER OPERATION OF AN EMERGENCY FUEL SHUT-OFF WHICH WILL SECURE THE FUEL AT THE TANK AND BE ACCESSIBLE OUTSIDE THE FUEL SPACE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
SERVICE LIFE RAFT OR PROPERLY INSTALL LIFE FLOAT.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Engineering
Issued 16 May 1991
Resolved
CONDUCT AN UNDERWAY TEST TO EXAMINE SAILS/RIGGING AND TEST MAIN PROPULSION ENGINE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Fire Fighting
Issued 16 May 1991
Resolved
PROVIDE A HAND PORTABLE FIRE/BILGE PUMP.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Navigation
Issued 16 May 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE FORWARD STEAMING LIGHT.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Documentation
Issued 16 May 1991
Resolved
PROVIDE A MEANS FOR PROPERLY POSTING ALL CERTIFICATES.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
PROVIDE AND POST AN EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Documentation
Issued 16 May 1991
Resolved
PROVIDE AND POST FCC RADIOTELEPHONY SAFETY AND STATION LICENSE.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Lifesaving
Issued 16 May 1991
Resolved
LABEL LIFE PRESERVER LOCKERS WITH "ADULT" AND "CHILD". STENCIL THE AMOUNT OF LIFE PRESERVERS IN EACH LOCKER.
Condition: Unknown
Due 16 May 1991
Resolved 16 May 1991
Construction/Loadline
Issued 19 July 1989
Resolved
MAKE PERMENANT REPAIRS TO AREA PATCHED AT THRUSTER HULL PENATRATION ON PORT AND STARBOARD BOW AT NEXT DRYDOCKING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Documentation
Issued 27 September 1988
Resolved
PROVIDE EVIDENCE OF RADIOTELEPHONY CERTIFICATE. VESSEL OPERATION WHEN CARRYING PASSENGERS IS LIMITED TO 1000 FT. FROM SHORE UNTIL SUCH TIME.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988
Resolved
INSTALL AN ADDITIONAL 6" OF INSULATION ON MAIN ENGINE EXHAUST LINE AT TOP.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Construction/Loadline
Issued 27 September 1988
Resolved
REPAIR DOOR TO FWD CABIN
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988
Resolved
INSTALL GUARD IN WAY OF BELT DRIVEN ON MAIN DIESEL ENGINE.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988