VICTORIAN PRINCESS

VICTORIAN PRINCESS is a 1985 passenger vessel (inspected). The Coast Guard has recorded 104 inspections since 1986, most recently in July 2025, along with 184 deficiencies, 1 operational control and 15 casualty investigations between 2002 and 2025.

Records from 1986 to 2025. Most recent: inspection, 28 July 2025.

Built
1985
Last inspected
28 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK3681
271869
Flag
UNITED STATES
368047620
Maury page id
psix-271869

Inspections, by type

…with no type recorded25
Years with a record 38 calendar years (1986–2025)
The 104 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)67.0 ft × 24.0 ft × 4.5 ft
Registered tonnagegross 46 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLA CROSSE RIVERBOAT CO · LACRESCENT, MN, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portERIE, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Simplified, Gross Ton
37 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK3681MMSI 368047620 · active · compulsorily equipped · granted 28 June 2018, expires 28 June 2028
WCY2161MMSI 367326420 · expired · voluntarily equipped · granted 12 December 2007, cancelled 12 May 2018
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 104

28 July 2025 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8197333
25 June 2025 Deficiency Check · Damage Survey · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8167819
25 June 2025 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8167882
30 July 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7971302
7 April 2024 In-Service Inspection · Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7891380
7 April 2024 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7907449
11 September 2023 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7789728
6 June 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7709400
4 October 2022 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7624598
27 September 2022 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7567311
17 August 2022 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7540709
29 June 2022 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7492283
5 May 2022 COI Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7430051
1 December 2021 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7360340
29 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7341908
5 October 2021 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7327760
27 July 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7265313
28 July 2020 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7019092
5 June 2020 Deficiency Check · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6973014
5 June 2020 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6991174
17 September 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6814269
14 September 2019 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6815177
7 September 2019 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7182717
10 July 2019 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6747886
8 July 2019 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6741669
8 August 2018 Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6504839
8 August 2018 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6512670
17 July 2018 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6503587
27 June 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6457570
2 May 2018 Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6404036
1 May 2018 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6413761
1 May 2018 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6450703
1 March 2017 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6096975
10 November 2016 Administrative Inspection · Drydock Exam · Deficiency Check · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6038918
1 July 2016 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5925933
22 June 2016 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5915535
9 June 2016 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5908126
9 June 2016 Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5917403
4 June 2016 In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5899837
3 June 2016 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5899816
11 April 2016 Administrative Inspection · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5874274
30 March 2016 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5843730
12 August 2015 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5218843
25 August 2014 Administrative Inspection · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4965904
18 June 2014 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4892585
5 May 2014 Administrative Inspection · In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4851214
2 May 2014 In-Service Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4849298
1 May 2014 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4850778
8 June 2012 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4340964
30 May 2012 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4335753
1 May 2012 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4300656
13 December 2011 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4209505
5 May 2009 Annual Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3468507
28 April 2008 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3224940
15 May 2007 Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2930933
25 April 2007 COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2902248
2 May 2006 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2638373
2 May 2005 Administrative Inspection · Periodic Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2443759
2 November 2004 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2229854
1 June 2004 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2098394
3 May 2004 Periodic Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2057895
21 April 2004 Drydock Extension
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2048966
28 June 2003 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1828953
7 May 2003 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1786940
15 August 2002 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1664366
12 June 2002 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1629946
10 May 2002 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1615369
23 May 2001 Deficiency Check · Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1460536
15 August 2000 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 820921
25 May 2000 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1365784
10 May 1999 COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1442851
9 April 1999 Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 787029
9 April 1999 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 809468
9 April 1999 Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1450298
11 March 1999 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 809581
6 June 1998 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 158825
10 April 1998 Drydock Extension
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 791401
10 April 1998 Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1381233
30 May 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390567
18 November 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1469143
5 September 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466985
30 May 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1396539
20 September 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1190182
23 June 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1192663
9 August 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1177052
1 June 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1333914
1 June 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142387
15 October 1992 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1252370
29 July 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1266365
1 June 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1263656
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1002853
4 June 1991 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1033434
10 October 1990 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1227363
18 July 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1226660
7 June 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232454
19 September 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1200917
8 June 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1035509
13 September 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351802
13 July 1988 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1345270
30 September 1987 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1011990
29 July 1987 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1337086
21 January 1987 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1317377
29 September 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1327797
20 August 1986 Initial Certification · Initial Construction-Excluding Oversight · Credit Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 987181

Deficiency record · 184

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2025 Resolved
Life jackets stowage locations were not properly marked with the quantity of available life jackets. Mark each location with the number of available life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2025
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 28 July 2025 Resolved
The forward gangway plank winch cable had not been serviced and was damaged. All equipment on board shall be serviceable an ready for safe operation. Replace winch cable as necessary to ensure safe operation of gangway plank winch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 June 2025 Resolved
Propulsion machinery must be suitable. Vessel lost propulsion due to hydraulic oil leak. Repair to the satisfaction of attending CG Marine Inspector. 46CFR182.200
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2025
Resolution: hydraulic leak was repaired and both engines test ran dockside; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 April 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel's PORT hydraulic propulsion system non-operational following failure of hydraulic system hose. Repair/replace PORT hydraulic propulsion system in kind. 46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2024
Resolved 8 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2023 Resolved
Portable fire extinguisher on aft of upper deck had been discharged and requires servicing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 September 2023 Resolved
Starboard main engine was leaking oil and the oil drain hose was loose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 September 2023 Resolved
Remove excess pooled oil from starboard engine bilge area.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 September 2023
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 June 2023 Resolved
Upperdeck railing was found partially unsecured to deck bracket. Make permanent repairs to starboard side upper deck railing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2023 Resolved
Main deck forward life ring was found with less than 60' of required line. Ensure life ring is equipped with required 60' of buoyant, dark colored or UV resistant line.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2023 Resolved
Second deck port side life ring was found with damaged retro-reflective tape. Replace retro-reflective tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 6 June 2023 Resolved
Replace damaged safety clip on gangway winch line
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 June 2023
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 June 2023 Resolved
Starboard side of paddle wheel hydraulic line was found leaking. Ensure all leaking lines are repaired
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 June 2023 Resolved
Automatic bilge pump float switch in engine room was sparking during operational test. Repair ground to eliminated arcing and sparking
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 June 2023 Resolved
Power driven bilge pump suction in stern bar bilge could not produce suction. Repair and ensure proper operation of all bilge pump suctions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2023
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 6 June 2023 Resolved
Conduct required drills in the presence of a CG Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2023
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 27 September 2022 Resolved
Heat tape installed on the raw water lines for winter storage was covered in engine oil and hydraulic oil that was discovered in the bilges of the engine room space. Remove heat tape and reinstall as necessary to eliminate the fire hazard prior to winter use.
Action required: 705 - Other - as specified
Resolved 4 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 September 2022 Resolved
Crew could not determine the source of engine and hydraulic oil in bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2022
Resolution: Gasket is know to leak, but not significantly. Oil was spilled in the bilge during maintenance and not cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2022 Resolved
Remove dead ended wires within engine room space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2022
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 September 2022 Resolved
Remove oily waste in engine room bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2022 Resolved
Battery box on port side was not covering terminals. Repair battery box.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 27 September 2022 Resolved
Replace lower chain/wire coarse on the gangway gate
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 May 2022 Resolved
1st Aid Kit had expired Aspirin. Replace with non- expired aspirin.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 5 May 2022 Resolved
2nd deck light fixture was missing globe. Install globe on light fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 5 May 2022 Resolved
Second deck maximum passenger capacity was incorrectly labeled. Label 2nd deck passenger count at 43 on forward and midship stairwell access.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2022 Resolved
3rd deck was missing life jacket donning placard. Provide a donning placard for 3rd deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2022 Resolved
Labeling of life jacket storage on 3rd deck was fading and illegible. Re-label life jacket storage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2022 Resolved
Storage area for Child sized life jackets was not labeled. Label main deck storage area for Child life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2022 Resolved
Bilge suction lines were not labeled. Label bilge suction lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2022 Resolved
Bilge pump was missing hose clamps on overboard side. Install 2 hose clamps at bilge pump discharge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 5 May 2022 Resolved
Gangway stay supports on port and starboard rail were wearing thin. Repair/replace stay connections.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 6 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 May 2022 Resolved
Fire pump must produce 50 gpm at 60 psi. fire pump could not produce more than 14 psi. Repair/replace fire pump
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2022
Resolved 29 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2021 Resolved
Portable fire extinguisher in forward "galley" space was not serviced. Provide annual service receipt for portable fire extinguisher.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 27 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 July 2021 Resolved
Electric bilge pumps were found to be unsecured within the protected spaces. Mount/secure the electric bilge pumps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 26 August 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 27 July 2021 Resolved
Light fixture in sewage space was found broken and loose. Repair/replace light fixture.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 26 August 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 July 2021 Resolved
Electrical junction box cover was found missing/broken. Repair or replace electrical junction box cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 26 August 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 July 2021 Resolved
Fuel shutoff cable was stiff and difficult to actuate. Conduct maintenance to allow smooth and easy operation of remote fuel shutoff.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 August 2021
Resolved 26 August 2021
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 July 2020 Resolved
Current COD was not onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2020
Resolved 25 August 2020
Resolution: Documentaion was placed on board
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 July 2020 Resolved
vessel name and hailing port was not marked on the stern
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 2 October 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 July 2020 Resolved
Masthead ligth was inoperable
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 11 August 2020
Resolution: Replaced in kind with new masthead light
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 July 2020 Resolved
Stowage are on maindeck was not marked with size and quantity
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 11 August 2020
Resolution: Sign was posted above storage area to indicate location.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 July 2020 Resolved
Stormrail on port bow walkway was loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 25 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 July 2020 Resolved
Deck lighting covers were not installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 10 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 July 2020 Resolved
Electical cover on hot water heater was not secured.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 25 August 2020
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 July 2020 Resolved
Broken light fixture in engine room
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 25 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 28 July 2020 Resolved
Update the Captains' acknowledgement checklist to include identification of current and forcasted wind speed prior to getting underway.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2020
Resolved 25 August 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2020 Resolved
Port M/E sustained overheat condition durring normal operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2020
Resolution: Vessels mechnaic replaced impeller on S/W cooling pump, cleaned, and backflushed strainer and cooler. Port M/E was run at the pier for approximately 2 hours at full load with no reoccorance of the overheat condition.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 September 2019 Resolved
Immediately after addressing safety concerns, the owner, agent, master, or person in charge of a vessel involved in a marine casualty shall notify the nearest Sector Office whenever a vessel is involved in a marine casualty consisting of an occurrence materially and adversely affecting the vessel's seaworthiness or fitness for service or route. On September 13, 2019 the vessel had an allision with the pier in Erie, PA. The vessel's gangway was damaged and required repairs. Those repairs were completed without prior Coast Guard oversight. The vessel is not allowed to carry passengers until the repairs have been witnessed by an attending Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2019
Resolved 18 September 2019
Resolution: Attended vessel to witness satisfactory repairs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 September 2019 Resolved
Repairs to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] were made to the gangway, that is the means of recovering a man overboard, without prior approval of the Coast Guard. Provide written documentation for all repairs made prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2019
Resolved 18 September 2019
Resolution: The vessel's O/O submitted a repair plan while on board to check repairs.s
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 30 July 2019 Resolved
Vessel is required to conduct drills on board and log monthly. The operator failed to provide records of monthly drills. Vessel's crew will ensure monthly drills are conducted moving forward. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 July 2019
Resolved 30 July 2019
Resolution: The vessel's crew has the forms on board and has been conducting drills and will ensure moving forward they log each occurence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 July 2019 Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. Found multiple jacket on the top deck that needed to be re-stenciled. The vessel's crew completed this prior to my departure. Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 July 2019
Resolved 30 July 2019
Resolution: The vessel's crew re-stinciled the jackets before the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2019 Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. The batteries in the life ring light had not been replaced. The crew replaced during the inspection. Cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 July 2019
Resolved 30 July 2019
Resolution: The vessel's crew replaced the batteries before the completion of the inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 July 2019 Resolved
Propulsion machinery shall be suitable in type and design without exceeding its designed limitations. During the inspection, it was discovered that the starboard main engine was missing rear case bolts and others were loose causing unnecessary leaks. Correct within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2019
Resolved 1 August 2019
Resolution: The vessel's mechanic sent a picture showing all of the newly installed bolts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 30 July 2019 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. During inspection, the mounting bolts on the planetary gear set on the port paddle wheel assembly were found to be backing off. Correct within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 August 2019
Resolved 1 August 2019
Resolution: The vessel's mechanic sent pictures of the corrected mounting bolts.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2019 Resolved
Auxiliary machinery shall be suitable in type and design for the purpose intended. The vessel's port generator suffered a casualty due to overheating causing the generator to smoke and the vessel to return to the pier. Affect repairs and test to the satisfaction of attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2019
Resolved 11 July 2019
Resolution: Attended vessel to witness repairs and test generator with no issues.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2018 Resolved
Piping used in vital systems is requires to be composed of ferrous materials. During annual inspection nonmetallic sea strainers were found. The vessel needs to replace strainers to be in accordance with 46 CFR 182.710 (c) within 60 days from this issuance of this deficiency.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 October 2018
Resolved 30 July 2019
Resolution: The vessel's crew ordered replacement parts for their strainers and replaced in kind. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 August 2018 Resolved
Flexible nonmetallic hose must meet SAE J-1942 and must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose. Hose end fittings must comply with SAE J-1945. During inspection found all fuel supply and return hoses on the starboard and port main & starboard and port generator are not in compliance with the above standards. Deficiency needs to be cleared by August 24, 2018.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2018
Resolved 5 September 2018
Resolution: Attended vessel and witnessed newly installed USCG A1 approved flexible hoses.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 August 2018 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements. The starboard paddle wheel hydraulic system was discovered leaking hydraulic fluid. Proper repairs need to be made to the satisfaction of an attending marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2018
Resolved 10 August 2018
Resolution: Observed operation of hydraulic motor assembly attached to vessel's paddle wheel. Conducted operational tests ahead and astern propulsion, both sat. No observed leaking/drips of hydraulic fluid from any of the attached hydraulic motor hoses
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 July 2018 Resolved
The vessel is required to have a station license issued by the FCC. The vessel's owner/operator was not able to provide a copy of the renewed license.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O provided proof of new FCC license.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 July 2018 Resolved
The vessel is required to carry a first aid kit approved under 46 CFR 160.041. The kit on board contained multiple expired items.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O purchased a brand new first aid kit.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 18 July 2018 Resolved
The second deck is limited to 55 passengers per the vessel's stability letter. The aft stairs need to be marked to reflect this number.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O marked the aft stairs with 55 passengers allowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2018 Resolved
The vessel's portable bilge pump in the aft soda void has a deteriorated hose causing water to flow back into the space. The hose needs to be replaced and the valve to that space needs to be secured until replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O replaced the hose from the portable bilge pump.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 18 July 2018 Resolved
A vessel on a Lakes Bays and Sounds route is required to carry three red hand flares and 3 orange smokes. The vessel only had 4 flares on board during the inspection. The crew went out and bought the appropriate number and this deficiency was cleared on the spot.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2018
Resolved 18 July 2018
Resolution: The crew purchased two additional flares.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 July 2018 Resolved
Each wire connection must be made within an enclosure and be in accordance with 46 CFR 183.05-50. Found four wires connected underneath the operating station with a screw and nut instead of properly attached to terminal or fitted with a pressure connection.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O removed the nut and replaced with pressure fittings.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 18 July 2018 Resolved
The master shall operate the vessel keeping the safety of the passengers and crew foremost in mind by directing the vessel in order to prevent a casualty. During the inspection, the vessel was moored port side for maintenance and the vessel's master was not able safety depart the pier without rubbing down the side of the pier. Provide a detailed plan and procedures to be implemented into your daily operations for mooring and departing the pier.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: Vessel O/O provided a plan for mooring and departing the pier.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 July 2018 Resolved
Battery terminal connections shall be made to the battery terminals with permanent type connectors. Wing nuts were found on the battery terminals.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O removed wing nuts from the battery.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2018 Resolved
The vessel is required to maintain all machinery in order to provide adequate protection against fire, explosion, machinery failure and personnel injury. During the inspection the following hoses were discovered in poor condition needing replacement: 1. Breather Hose on the starboard main. 2. Small coolant hose on the starboard and port main 3. Hose on the raw water discharge on starboard main. 4. Provide chaffing gear on coolant hose on starboard generator. All hoses need to be replaced with approved hoses meeting either: SAE J-1942 or USCG Type A1, A2, B1 or B2 flexible hose. Reference 46 CFR 182.720 for more information.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2018
Resolved 1 August 2018
Resolution: The vessel O/O replaced all required hoses.
Engineering › Fuel Oil Service System › Filter
Issued 2 May 2018 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements. The starboard engine repairs need to be made and verified by a Coast Guard Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2018
Resolved 4 May 2018
Resolution: Engineer had changed out fuel filter
Electrical › Electric Generation Source (service) › Power Requirement
Issued 2 May 2018 Resolved
A vessel must be provided with an auxiliary means of steering. Starboard generator is currently inoperable. Starboard generator is used to power unit/pump needed for auxiliary means of steering.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 May 2018
Resolution: Starter and fuel filter had been replaced.
Fire Fighting › Fire Hoses › Condition
Issued 21 April 2017 Resolved
Fire hoses (03) leaking. Replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 1 May 2017
Fire Fighting › Fire Hydrants › Condition
Issued 21 April 2017 Resolved
Repair/Replace 03 fire hydrant valves, leaking.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 1 May 2017
Resolution: Valves Replaced
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 April 2017 Resolved
Provide first aid kit contents IAW 46 CFR 160.041
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 1 May 2017
Lifesaving › Lifebuoys › Serviceable
Issued 21 April 2017 Resolved
Replace grab line and retro-reflective material on 01 20" ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 1 May 2017
Resolution: Ring Life buoy replaced with new.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 April 2017 Resolved
Replace expired waterlight batteries.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2017
Resolved 1 May 2017
Construction/Loadline › Hull › Longitudinal Frame
Issued 21 November 2016 Resolved
Crop & Renew gang way pedestal beam in its entirety from swivel point through stem to collision bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 December 2016
Engineering › Thrusters › Tunnel
Issued 21 November 2016 Resolved
Gauge bow thruster tube IVO propeller noting pitted areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 December 2016
Construction/Loadline › Hull › Stiffener
Issued 21 November 2016 Resolved
Crop & Renew starboard rub rail support stiffeners and 03 main deck stiffeners as identified by attending MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 December 2016
Construction/Loadline › Hull › Stiffener
Issued 21 November 2016 Resolved
Crop & Renew rub rail support IVO starboard quarter as identified by attending MI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 December 2016
Construction/Loadline › Hull › Strut/Cross Tie
Issued 21 November 2016 Resolved
Crop & Renew wasted areas of the transverse beam (tube), aftermost structure of vessel where trailing rudders are mounted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 1 December 2016
Construction/Loadline › Structures › Deck Plating
Issued 21 November 2016 Resolved
Crop & Renew main deck areas and support structures IWO paddle wheels as identified by attending MI
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 12 December 2016
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 21 November 2016 Resolved
Gauge waste pipe, starboard side where it meets deck and up 12".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 22 November 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 November 2016 Resolved
Replace forward mast head light
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 April 2017
Resolution: New Mast Light Installed
Construction/Loadline › Hull › Transverse Frame
Issued 21 November 2016 Resolved
Gauge forward side of collision bulkhead, centerline and out 12" from overhead to keel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 22 November 2016
Construction/Loadline › Hull › Bottom Plating
Issued 21 November 2016 Resolved
Gauge bottom plate in forepeak from collision bulkhead forward to first transverse from and out from CVK to first longitudinal frame, both sides.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 22 November 2016
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 21 November 2016 Resolved
Replace forepeak ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 April 2017
Resolution: Ladder repaired, properly supported.
Construction/Loadline › Structures › Deck Plating
Issued 21 November 2016 Resolved
Crop and renew wasted deck areas around drainage scuppers on 2nd and 3rd decks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 April 2017
Resolution: Wasted Areas of 2nd and 3rd decks cropped out to geed metal and renewed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 November 2016 Resolved
Renew hydraulic hoses as identified by attending MI
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 22 November 2016
Engineering › Thrusters › Blade
Issued 21 November 2016 Resolved
Renew rotted wooden paddle wheel blades as identified by attending MI.
Condition: Improper/Lack of Maintenance
Due 31 March 2017
Resolved 21 April 2017
Resolution: New boards installed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 November 2016 Resolved
Repair fractured railing support brackets, 3rd deck, starboard side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 21 April 2017
Resolution: New rail supports installed.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 November 2016 Resolved
Crop and renew wasted area of the aft superstructure where triangular doubled is installed
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 12 December 2016
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 July 2016 Resolved
Provide proof of bilge inspections prior to each voyage or at least daily.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Daily rounds of vessels bilges being performed and logged in maintenance manual.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 July 2016 Resolved
Remove or properly secure dead end wires under operator’s console, port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Dead end wires under port side of operators console removed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 July 2016 Resolved
Remove liquid substance in steering space. Soda syrup container bursted in concession rack.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Aft steering space bilge clean and dry.
Electrical › Electric Supply System (service) › Battery Installation
Issued 6 July 2016 Resolved
Properly secure engine room battery connections, corrected prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 6 July 2016
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 July 2016 Resolved
Install electrical panel blank in engine room as identified by the attending CG MI
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Electrical panel blank installed satisfactorily in E/R panel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2016 Resolved
Stencil all ring life buoys with vessel name in legible capital block letters.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Ring life buoys properly marked with vessel name.
Lifesaving › Lifebuoys › Serviceable
Issued 6 July 2016 Resolved
Renew grab line on port forward ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Port forward ring life buoy renewed in lieu of repair to grab line.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 July 2016 Resolved
Stow proper quantity of life preservers in accordance with stowage placards, corrected prior to departure.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 6 July 2016
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 6 July 2016 Resolved
Renew or make legible life jacket stowage placards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Life jacket stowage placards properly, legibly marked.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 July 2016 Resolved
Provide current up to date navigation publications.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 25 July 2016
Resolution: Examined printed up to date navigation charts, printed and electronic Local Notice to Mariners, printed and electronic Light List excerpt, printed and electronic Coast Pilot excerpt, and elctronic Navigation Rules handbook.
Fire Fighting › Fire Hydrants › Condition
Issued 6 July 2016 Resolved
Repair leaking hydrant valve on port aft upper hydrant.
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Port aft upper hydrant valve stem leak repacked and no longer leaking.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 July 2016 Resolved
Make proper repairs to gangway pedestal to prevent pintle from disengaging gudgeon, corrected prior to departure.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 July 2016
Resolved 6 July 2016
Resolution: Securing bolts installed in lower exposed area of pintle below gudgeon to prevent pintle from separating from gudgeon.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 July 2016 Resolved
Perform fire and MOB drills to written procedures.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 July 2016
Resolved 22 July 2016
Resolution: Witnessed successful underway man overboard and firefighting drills to adequate written procedures.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 9 June 2016 Resolved
Proove Proper Operation of A/C Raw Water System, Conduct Operational Testing of machinery in flooded space.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2016
Resolution: New hose and clamps installed, system operation verified. All machinery operations in affected space verified.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 August 2014 Resolved
Determine Total Capacity of Type II MSD's
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 26 August 2014
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 August 2014 Resolved
Determine total capacity of Potable water tanks.
Action required: 705 - Other - as specified
Due 29 August 2014
Resolved 26 August 2014
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 25 August 2014 Resolved
Priot to daily operations and each voyage dertermine liquid loads and record findings in vessel log.
Due 29 August 2014
Resolved 26 August 2014
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 July 2014 Resolved
All covered employees shall sign company policy statement
Action required: 705 - Other - as specified
Due 4 August 2014
Resolved 28 July 2014
Resolution: All covered employees have signed empoyer policy statement
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 28 July 2014 Resolved
Repair fuel leak at injector fuel return line on starboard engine.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 July 2014
Resolution: Fuel return line manifold replaced
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 5 May 2014 Resolved
Due to repeated oil spills originating from overflowing sewage tank, vessel is to secure water onboard until plumbing issue located and corrected to satisfaction of attending marine inspector PRIOR TO SAILING. 33 CFR 184.702
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 May 2014
Resolution: Previous conversation with vessel rep stated that source of overflow was constantly running toilet that overfilled the tank and caused residue to release out the vent. Toliet has since been reported as repaired.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 5 May 2014 Resolved
Remove all oil and oil residues from Marine Sanitation System by cleaning tank, vents, and associated piping to satisfaction of attending Marine Inspector PRIOR TO CARRYING PASSENGERS. 3rd party certification of oil removal from system will meet satisfaction requirement. 33 CFR 184.702
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2014
Resolution: Cleared to satisfaction of attending inspector.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 May 2014 Resolved
Clean stbd side of vessel to remove all traces of sewage residue and oil residue to satisfaction of attending Marine Inspector PRIOR TO CARRYING PASSENGERS. 33 CFR 184.704
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2014
Resolution: Received picture (attached to activity) showing sorbent pads to clean oil residue. Item cleared.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 5 May 2014 Resolved
Institute company policy and conduct training of crew members logged into log book ceasing the collection and discharge of oil residues into the vessels marine sanitation system to satisfaction of attending marine inpsector PRIOR TO CARRYING PASSENGERS. 33 CFR 184.702
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2014
Resolution: Cleared to satisfaction on attending inspector.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 2 May 2014 Resolved
Monitor Oil Tank Levels twice per day for next 14 days to ensure oil tanks are not source of leak. Determine repairs and make reparis to satisfaction of attending USCG inspector. If reparis are needed complete prior to sailing with passengers. report all findings, positive or negative to USCG. 33 CFR 184.702
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 10 May 2014
Resolution: Def cleared to satisfaction of attending inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 May 2009 Resolved
Prove function of emergency fuel shutoff prior to carrying passengers per 46CFR182.455(a)(4). Emergency fuel shutoff valve did not fully close fuel valve from visual inspection of operation. Lever still had 1.5 inches to go to fully close when T handle pulled on main deck. During fire drill, crewmember pulled the T handle while engines were running and the engines did not shut down.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2009
Resolved 8 May 2009
Stability › Unintentional Flooding › General
Issued 5 May 2009 Resolved
Install proper deck vent for macerator vents IAW 33CFR151, 155, 156. Deck vent missing on STBD side going into the macerator hold, which is connected to the macerator vents. Fitting was taped over at arrival.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2009
Resolved 8 May 2009
Operations/Management › Drills/Instruction › Fire
Issued 5 May 2009 Resolved
Re-do Emergency Procedure Instructions IAQ 46CFR185.510 designed to address the particular equipment, arrangement, and operation of the vessel, and conduct drills in accordance with the procedures in the presence of a Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2009
Resolved 8 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 May 2009 Resolved
Properly wire Air Conditioning electrical pump and replace rubber hose. Electrical mechanical connector is broken and wires exposed and unsupported. Rubber hose is cracked and worn.
Due 5 June 2009
Resolved 26 May 2009
Resolution: Attended vessel and inspected arrangement finding new hose installed and cable secured within pump housing and throughout it run as required.
Accommodation/Occupational Safety › Heating › Piping
Issued 5 May 2009 Resolved
Secure hot water tank, strengthen or replace shelf, and repair leaking lines on heating service tank 2nd deck fwd PORT closet IAQ 46CFR176.800(a).
Condition: Design Flaw
Due 5 June 2009
Resolved 8 May 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 May 2009 Resolved
Replace waterlight line on 3rd deck life ring IAW 46CFR180.70(d)
Due 5 June 2009
Resolved 8 May 2009
Lifesaving › Lifebuoys › Serviceable
Issued 5 May 2009 Resolved
Repair rip in life ring 2nd deck STBD side.
Due 5 June 2009
Resolved 8 May 2009
Documentation › Certificates/Documents › Stability Letter
Issued 5 May 2009 Resolved
Post Stability Letter IAW 46CFR176.306.
Due 5 June 2009
Resolved 8 May 2009
Electrical › Electric Supply System (service) › Transformer
Issued 5 May 2009 Resolved
Secure / mount 220V transformer (phase motor) in wheelhouse PORT side cabinet IAW 46CFR176.800.
Condition: Improper Installation
Due 5 June 2009
Resolved 26 May 2009
Resolution: Attended vessel and inspected installation finding cable secured inside housing of cabnet and arrangement meeting the requirements from reg and code.
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 5 May 2009 Resolved
Repair sewer line plug leaking in PVC pipe and clean sewage from bilge IAW 33CFR151.
Due 5 June 2009
Resolved 26 May 2009
Resolution: Inspected arrangement, finding section of piping replaced with repairs completed satisfactory.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 April 2008 Resolved
Wires for steering controls of the starboard rudder require replacement with broken coatings due to chaffing from unsupported length.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 2 May 2008
Resolution: Wires replaced and supported appropriately.
Engineering › Bilge Water Management System › Pump
Issued 28 April 2008 Resolved
Prove proper operation of bilge pumping from the lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 28 April 2008
Resolution: Repairs completed and operation found satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 28 April 2008 Resolved
Replace through hull penetrations for bilge discharge lines as all are wasted beyond repair in addition install positive shutoff valves.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 2 May 2008
Resolution: Penetrations replaced with valves installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 28 April 2008 Resolved
Replace retro-reflective tape on 7 child life jackets, and 14 adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2008
Resolved 2 May 2008
Resolution: Reflective tape replaced on all required jackets.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 April 2007 Resolved
Conduct underway drills in presence of CG inspector
Due 25 May 2007
Resolved 14 May 2007
Resolution: underway man overboard and fire drill conducted in presence of MKC m. Kopera
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 April 2007 Resolved
Properly secure the hydraulic oil cooler under the starboard side main engine (3 of 4 bolts missing)
Due 25 May 2007
Resolved 14 May 2007
Resolution: hydraulic cooler properly secured
Electrical › Electric Supply System (service) › Cable
Issued 2 May 2006 Resolved
Properly mount battery cutout switch in engine room prior to commercial service.
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 8 May 2006
Resolution: Attended vessel and witnessed satisfactory installation of new barrel switch.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 2 May 2006 Resolved
Properly support battery cutout switch conductor every 24 inches prior to commercial service.
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 8 May 2006
Resolution: Attended vessel and witnessed satisfactory installation of wire metal supports.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2006 Resolved
Replace warn/missing reflective tape on lifebuoys and properly attach line to buoy on main deck. Must be completed prior to commercial service.
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 8 May 2006
Resolution: Attended vessel and witnessed satisfactory replacement of line and retro.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 May 2006 Resolved
Replace reflective tape on 8 adult lifejackets.
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 8 May 2006
Resolution: Attended vessel and witnessed replacement of 8 life jackets, with selected jackets removed from vessel.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 2 May 2006 Resolved
Properly mouse all shackle pins prior to using winch platform.
Action required: 705 - Other - as specified
Due 8 May 2006
Resolved 8 May 2006
Resolution: Attended vessel and witnessed mousing applied to all ground tackle and hardware for platform.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 May 2005 Resolved
Vessel is limited to daytime operations until stern light is made operational.
Due 2 May 2005
Resolved 6 May 2005
Resolution: Witnessed satisfactory operation of all navigation lights.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2005 Resolved
Remove excessive dead ended wires in lazarette.
Due 2 June 2005
Resolved 6 May 2005
Resolution: Witnessed removal of excessive dead ended wires.
Fire Fighting › Fire Pumps › Arrangement
Issued 2 May 2005 Resolved
Replace broken gauge on fire pump.
Due 2 May 2005
Resolved 6 May 2005
Resolution: Witnessed replacement of gauge and satisfactory pressure during operational check.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2005 Resolved
Remove wire nuts and correctly route wires to electrical distribution box.
Due 16 May 2005
Resolved 6 May 2005
Resolution: Witnessed satisfactory installation of wires for installed condenser unit.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 May 2005 Resolved
Replace broken junction box cover IWO centerline in lazarette.
Due 2 May 2005
Resolved 6 May 2005
Resolution: Witnessed replacement cover to junction box cover.
Lifesaving › Lifebuoys › Quantity
Issued 2 May 2005 Resolved
Install life ring buoy on second deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 6 May 2005
Resolution: Received fax attesting to replacement, as well witnessed installation.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 2 May 2005 Resolved
Prove proper operations of main engines during underway testing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2005
Resolved 6 May 2005
Resolution: Witnessed satisfactory operation of mains during underway trip to complete emergency drills.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 2 May 2005 Resolved
Provide documentation attesting the receipt of supervisor training.
Due 2 June 2005
Resolved 29 July 2005
Resolution: Received fax statement from O/O attesting that all supervisors and crew have viewed video.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 28 October 2004 Resolved
Install required draft marks per 46 CFR 185.602. Operator will complete repairs during winter lay-up status and prior to start of next operating season.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 2 May 2005
Resolution: Witnessed draft markings permanently affixed to hull.
Construction/Loadline › Hull › Hull Plating
Issued 28 October 2004 Resolved
Repair pitting in way of bow thruster. Repairs to be completed during winter lay-up period and prior to start of next operating season.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 10 May 2005
Resolution: Previously approved by this office repairs were completed with clad welds with separation of over 12 inches between three areas of pitting.
Accommodation/Occupational Safety › Occupational Safety
Issued 3 May 2004 Resolved
Repair broken railing stanchion to deck attachment points on port and starboard sides of uppermost deck. No passengers are to be carried on uppermost deck until corrected. LEGACY COMPONENT DESC: Deck Rail
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004
Resolved 1 June 2004
Electrical › Electrical Distribution System (service)
Issued 3 May 2004 Resolved
Repair broken AC electrical outlet box on port side aft uppermost deck. LEGACY COMPONENT DESC: Outlet Box
Due 18 May 2004
Resolved 1 June 2004
Fire Fighting › Fire Hoses
Issued 3 May 2004 Resolved
Replace all 3 of 3 defective fire hoses prior to carrying passengers. LEGACY COMPONENT DESC: Condition
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004
Resolved 3 May 2004
Navigation › Piloting/Steering
Issued 7 May 2003 Resolved
Prove proper operation of port running light. Do not operate vessel in periods of reduced visability until complete. LEGACY COMPONENT DESC: Inland Navigation Rules
Due 7 June 2003
Resolved 26 June 2003
Resolution: observed proper operation of port running light. WAM
Navigation › Piloting/Steering
Issued 7 May 2003 Resolved
Prove proper operation of rudder angle indicator.
Due 7 June 2003
Resolved 26 June 2003
Resolution: observed proper operation of rudder angle indicator from bridge. WAM
Electrical › Electrical Distribution System (service)
Issued 7 May 2003 Resolved
Remove or protect bare wires and wire nuts under bridge console. LEGACY COMPONENT DESC: Conductor
Due 7 June 2003
Resolved 26 June 2003
Resolution: inspected wiring under console, allloose and unprotected wires now protected. WAM
Pollution Prevention/Response › Prevention Equipment
Issued 7 May 2003 Resolved
Provide proper cap for sewerage pipe on out board side of house. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 7 June 2003
Resolved 28 June 2003
Pollution Prevention/Response › Prevention Equipment
Issued 7 May 2003 Resolved
Remove oil from bilges. Vessel not to carry passengers until complete. LEGACY COMPONENT DESC: Oily Residue (sludge/slop) Tank
Due 7 June 2003
Resolved 26 June 2003
Resolution: all bilges clear of oil. WAM
Operations/Management › Drills/Instruction
Issued 10 May 2002 Resolved
Make vessel available for drills in presence of Marine Inspector.
Due 10 June 2002
Resolved 11 June 2002
Resolution: Satisfactory drills conducted.
Fire Fighting › Nozzles
Issued 10 May 2002 Resolved
Replace all three fire fighting nozzles with nozzles capable of fog and stream application.
Due 10 June 2002
Resolved 11 June 2002
Resolution: New approved nozzles installed.
Communications › Visual Communication
Issued 10 May 2002 Resolved
Install three more lifejacket placards, 0ne for each deck.
Due 10 June 2002
Resolved 11 June 2002
Resolution: Additions complete>
Engineering › Bilge Water Management System
Issued 10 May 2002 Resolved
Prove proper operation of bilge suction line in sewerage compartment.
Due 17 May 2002
Resolved 16 May 2002
Construction/Loadline
Issued 23 May 2001 Resolved
Prove proper ops of aft bilge strainer.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Navigation
Issued 23 May 2001 Resolved
Prove proper operation of anchor lights.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Engineering
Issued 23 May 2001 Resolved
Prove proper ops of both MDE tachometers.
Condition: Unknown
Due 23 June 2001
Resolved 11 June 2002
Resolution: Complete.
Engineering
Issued 23 May 2001 Resolved
Remove dead end wires under pilothouse console-replace wire nuts with junction box or pressure connections as appropriate.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Documentation
Issued 23 May 2001 Resolved
Prove monthly required drills are conducted with all hands.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Electrical
Issued 23 May 2001 Resolved
Remove dead end wires under pilothouse console-replace wire nuts with junction box or pressure connections as appropriate.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Engineering
Issued 23 May 2001 Resolved
Replace cracked / corroded double female hydraulic line fitting on port paddle wheel drive line.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Lifesaving
Issued 23 May 2001 Resolved
Replace or repair life ring buoy waterlight.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Documentation
Issued 23 May 2001 Resolved
Prove compliance with 46 CFR part 16.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Electrical
Issued 25 May 2000 Resolved
Remove or properly secure all wire nuts to ensure they do not vibrate lose.( numerous throughout the vessel)
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Electrical
Issued 25 May 2000 Resolved
Cover or remove bare wires throughout vessel.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Electrical
Issued 25 May 2000 Resolved
Install cover over 12 volt battery in 2nddeck closet and secure bare wire going to it.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Engineering
Issued 25 May 2000 Resolved
Install double hose clamps on all raw water lines.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Navigation
Issued 25 May 2000 Resolved
Prove proper operation of radar.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Construction/Loadline
Issued 11 March 1999 Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REQUIREMENTS.
Condition: Unknown
Due 11 March 1999
Resolved 11 March 1999
Lifesaving
Issued 23 June 1995 Resolved
Provide 6 additional orange smoke signals.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Electrical
Issued 23 June 1995 Resolved
Install cover on electrical junction box on steering system.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Construction/Loadline
Issued 10 October 1990 Resolved
CREDIT DRYDOCK DUE 10APR92. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 7 June 1990 Resolved
PROVIDE WATER LIGHTS (2) FOR BUOYANY APPRATUS MISSING WATER LIGHTS. COMPLETE THIS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Fire Fighting
Issued 7 June 1990 Resolved
REPLACE AFT FIREHOSE AND STENCIL VESSEL'S NAME ON HOSE. COMPLETE THIS ITEM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Documentation
Issued 19 September 1989 Resolved
CREDIT DRYDOCK DUE 19MAR91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 19 September 1989
Resolved 19 September 1989
Deck/Cargo
Issued 8 June 1989 Resolved
REMOVE VALVES FROM SEWAGE TANK VENTS.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Engineering
Issued 8 June 1989 Resolved
INSTALL HEAT SHIELDS ON STAHL FUEL FILTERS.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Documentation
Issued 13 July 1988 Resolved
OBTAIN AN FCC RADIO SAFETY CERTIFICATE BY 30AUG88.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Documentation
Issued 29 July 1987 Resolved
PLACE ON BOARD THE VESSEL THE ORIGINAL COPY OF THE COAST GUARD CERTIFICATE PF DOCUMENTATION. PROVIDE EVIDENCE OF SAME TO THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO 01SEP87.
Condition: Unknown
Due 29 July 1987
Resolved 29 July 1987
Documentation
Issued 20 August 1986 Resolved
PROVIDE STABILITY CALCULATIONS TO [name withheld] STABILITY LETTER.
Condition: Unknown
Due 20 August 1986
Resolved 20 August 1986
Lifesaving
Issued 20 August 1986 Resolved
INSTALL A SUITABLE RESCUE BOAT OR PROVE VESSEL HAS A SUITABLE RESCUE PLATFORM. THIS IS TO BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 20 August 1986
Resolved 20 August 1986
Fire Fighting
Issued 20 August 1986 Resolved
INSTALL FIRE HOSES THAT COMFORMS TO THE UNDERWRITERS' LAB., STANDARD 19 AND APPROVED FIRE HOSE NOZZLES. THIS IS TO BE COMPLETED PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 20 August 1986
Resolved 20 August 1986

Casualty record · 15

15 August 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1664366
23 May 2009Routine · role: Involved in a Marine Casualty · activity 3488665
1 May 2012Routine · role: Involved in a Marine Casualty · activity 4300656
8 June 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4340964
9 June 2016Routine · role: Involved in a Marine Casualty · activity 5908126
1 July 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5925933
1 May 2018Routine · role: Involved in a Marine Casualty · activity 6413761
1 May 2018Routine · role: Involved in a Marine Casualty · activity 6450703
17 July 2018Routine · role: Involved in a Marine Casualty · activity 6503587
7 September 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7182717
14 September 2019Routine · role: Involved in a Marine Casualty · activity 6815177
5 June 2020Routine · role: Involved in a Marine Casualty · activity 6991174
29 June 2022Routine · role: Involved in a Marine Casualty · activity 7492283
7 April 2024Routine · role: Involved in a Marine Casualty · activity 7907449
25 June 2025Routine · role: Involved in a Marine Casualty · activity 8167882
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ROSIE I, ROSIE O'SHEA, VICTORIAN PRINCESS (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.