Records from 1986 to 1999. Most recent: inspection, 21 June 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
21 June 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1455761
6 May 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1048708
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880060
19 May 1994
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1358428
18 May 1993
Re-Inspection · Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1155806
15 June 1992
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 956215
29 July 1991
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1001232
15 July 1991
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1247293
11 July 1991
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1247591
12 July 1990
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1226704
8 May 1990
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 908961
7 July 1989
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1206977
25 May 1989
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1037786
12 August 1988
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1346700
8 August 1988
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1346912
13 May 1988
Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1352836
30 March 1988
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1036463
30 July 1987
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1029919
16 July 1986
Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 998582
Documentation
Issued 19 May 1994
Resolved
PROVIDE 46 CFR PARTS 166-199 AND RULES OF THE ROAD.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 19 May 1994
Resolved
RELABEL 11 ADULT PFD'S WITH VESSEL'S NAME.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Lifesaving
Issued 8 August 1988
Resolved
PROCURE AN ADDITIONAL THREE (3) RED HAND FLARES AND SIX (6) ORANGE SMOKE FLARES NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Fire Fighting
Issued 8 August 1988
Resolved
PROCURE AN ADDITIONAL BII PORTABLE FIRE EXTINGUISHER NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Lifesaving
Issued 8 August 1988
Resolved
POST EMERGENCY CHECKOFF LIST AS REQUIRED BY 46 CFR 185.25 NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Documentation
Issued 8 August 1988
Resolved
OBTAIN GREAT LAKES AGREEMENT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Lifesaving
Issued 8 August 1988
Resolved
POST PFD DONNING INSTRUCTION PLACARDS AS NECESSARY NO LATER THAN COMPLAINCE DATE.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Construction/Loadline
Issued 30 March 1988
Resolved
CROP OUT TO GOOD METAL AND RENEW HOLED AND WASTED HULL PLATING IN WAY OF STBD BOW B-STRAKE AND THRU HULL FITTING.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Construction/Loadline
Issued 30 March 1988
Resolved
REPLACE ALL RIVETS AS ORIGINAL WHERE THE HEAD HAS WASTED AND WHICH ARE EXPOSED OR COVERED WITH FOAM.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Construction/Loadline
Issued 30 March 1988
Resolved
TRUE ALL TRANSVERSE BUTT PLATES IN A&B STRAKES TO ENSURE STRUCTURAL AND WATERTIGHT INTEGRITY.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988