OUTTA LINE

OUTTA LINE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1986, most recently in February 2026, along with 104 deficiencies and 1 casualty investigation in 2008.

Records from 1986 to 2026. Most recent: inspection, 11 February 2026.

Built
1986
Last inspected
11 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4492
271952
Flag
UNITED STATES
366809650
Maury page id
psix-271952

Inspections, by type

…with no type recorded9
Years with a record 37 calendar years (1986–2026)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.0 ft × 17.0 ft × 10.0 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS · DESTIN, FL, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 3 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4492MMSI 366809650 · active · voluntarily equipped · granted 21 March 2017, expires 21 March 2027
WDA4460MMSI 366809650 · cancelled · voluntarily equipped · granted 10 March 2011, cancelled 15 March 2017
WCZ3388MMSI not assigned · expired · compulsorily equipped · granted 15 June 1999, cancelled 15 August 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

11 February 2026 Administrative Inspection · COI Inspection · Vessel Attendance · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304765
19 December 2025 Drydock Exam · Administrative Inspection · Vessel Attendance · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285597
3 September 2025 Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226475
10 February 2025 Annual Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077479
29 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7904855
12 February 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864387
6 December 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7834548
9 November 2023 Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7824509
14 April 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7668743
20 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7653934
27 July 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7517591
11 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7449919
5 April 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426600
7 February 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7415585
29 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7271435
18 March 2021 Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7152737
10 June 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6974305
26 May 2020 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6961188
17 March 2020 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6947232
13 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6908651
25 September 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822592
6 August 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6775225
5 February 2019 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620260
23 October 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570727
24 May 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6416956
6 March 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364938
23 March 2017 Damage Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105448
26 April 2016 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5875547
29 March 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5842297
19 January 2016 Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5799398
22 February 2012 Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4280139
18 March 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3695932
16 February 2010 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3679431
21 April 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3456538
31 October 2008 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3358358
25 March 2008 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3169042
19 February 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3148204
22 March 2007 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2893566
3 April 2006 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2616188
8 March 2006 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2598090
6 April 2005 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2328020
16 March 2005 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2311361
9 April 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2038978
22 May 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1799621
15 April 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1773313
24 March 2003 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 1762430
8 April 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1603556
31 May 2001 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1452846
9 April 2001 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1445785
23 January 2001 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426606
19 September 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 822077
2 September 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1061547
16 August 2000 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1444397
3 August 2000 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821087
2 August 2000 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821238
16 May 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1455908
25 May 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1401064
12 January 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1042971
28 May 1998 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1473267
20 March 1998 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 160181
26 June 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 655393
20 June 1997 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 224461
17 June 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437312
13 August 1996 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1087160
18 June 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 215362
18 June 1996 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1396535
8 June 1995 Deficiency Check · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1360135
16 August 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 868804
5 July 1994 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1172964
16 December 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1159280
21 July 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 843084
19 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1152067
16 June 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1152970
16 June 1993 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1157737
19 January 1993 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 828513
3 September 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1260630
17 June 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 951546
17 July 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934272
17 July 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934274
20 June 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1234067
16 January 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1240386
5 July 1989 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1201948
10 August 1988 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1349366
27 January 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1327877
11 August 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1319035
25 June 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1315464
22 July 1986 Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985227

Deficiency record · 104

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 April 2023
Resolution: Interconnected fire detection provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023 Resolved
Inspect machinery. Stbd shaft stern tube clamps were unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2023
Resolved 21 March 2023
Resolution: Clamps renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Properly secure Bridge wiring. Dead end cable above operating station has loose, frayed, and exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Dead end cable made up properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Label switchboard breakers with labels. Provide proof of proper labeling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Breakers labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Correctly install Voltmeter and Frequency Meter for Generator.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2021
Resolved 29 July 2021
Resolution: Marine inspector arrived at the vessel to ensure proper installation of the voltmeter and frequency meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021 Resolved
Demonstrate Fireboy Main Diesel Engine Over-ride working satisfactorily. Operator could not operate Override system due to potential error with system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2021
Resolution: Override operationally.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Remove vice-grip pliers on Battery Box under the Operating Station. Provide proof of safe and operational electrical installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2021
Resolution: Vice grips removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021 Resolved
Collision blkhd has sluice valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Valve removed, penetration capped.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 March 2021 Resolved
Ensure and provide proof of Emergency Lighting installation on the Main Deck of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Emergency light renewed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2020 Resolved
Forward engine room bilge alarm is inoperable. Repair or replace forward engine room bilge alarm to, and provide evidence of satisfactory operating condition. Vessel is restricted from carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2020
Resolved 10 June 2020
Resolution: Replaced wiring to bilge alarm and provided satisfactory evidence of visual and audible alarm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2020 Resolved
Masthead light inoperable. Repair or replace masthead light. Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2020
Resolved 10 June 2020
Resolution: Replaced masthead light and provided evidence of satisfactory operation.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 June 2020 Resolved
Guards around rotating machinery in engine room not installed. Install guards around rotating machinery in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Guards installed on engines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 June 2020 Resolved
Hatch to lazarette found to have nuts and washers missing on 2 of the dogging arms, preventing the hatch from securing. Repair or replace dogging arms on hatch to ensure that the hatche secures when closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 June 2020
Resolution: Replaced washers and nuts and provided evidence of satisfactory operation of the hatch locking shut.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 June 2020 Resolved
Shaft packing around port shaft found to be excessively leaking. Tighten or replace shaft packing around port shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Replaced shaft packing on both port and starboard shafts.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 June 2020 Resolved
Smoke alarm missing from secondary passenger berthing location. Install appropriate UL 217 smoke alarm in the passenger berthing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Second smoke detector installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 June 2020 Resolved
Alcohol test strips on board found to be expired. Provide current alcohol test strips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2020 Resolved
There was no separation of adult life jackets to child life jackets in storage compartment. Install separator or divider in life jacket stowage location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Operator separated stowage of adult and child life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2020 Resolved
No light list found on board. Provide current light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019 Resolved
Vsl req'd to have emergency exits marked EMERGENCY EXIT - KEEP CLEAR. On both sies vsl missing KEEP CLEAR. Vsl to provide additional wording. 46 CFR 177.15 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2019
Resolved 25 September 2019
Resolution: Vsl placed wording on both sides of the emergency exit to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019 Resolved
Life jackets are req'd for every passenger. One life jacket was unservicable. Vsl to replace jacket. 46 CFR 180.71(a) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Marine Inspector verified new life jackets on board with proper markings and light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019 Resolved
Life jackets are req'd to be marked with retroreflective material. Three lifejackets did not have servicable tape installed. Vsl to replace retroreflective tape. 46 CFR 185.604(i) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced retroreflective tape to the satisfation of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2019 Resolved
Life ring is req'd to be marked with vessel name and have a line resistant to deterioration. Life ring is not marked w/ vessel name and line is severly deteriorated. 46 CFR 185.604(b) 46 CFR 180.70(b)(1) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel added name of vessel to the life ring and replaced the attached grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2019 Resolved
The waterlight is req'd to have a 3ft line attached resistant to deterioration. The line attached to the waterlight is severely deteriorated. 46 CFR 180.70(d)(2) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced the line on the waterlight with a 3 foot line attached to the body of the ring buoy with a corrosion resistant clip.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2019 Resolved
Vsl is required to have emergency instructions posted of actions to take in the event of fire, heavy weather, or man overboard. Vsl is missing these instructions. 46 CFR 185.510 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Posted emergency instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2019 Resolved
Fuel filter on starboard generator found leaking. Vsl to repair or replace. 46 CFR 182.20-40 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Replaced fuel oil filter, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2019 Resolved
Multiple flexible hose fittings on stbd generator are backing out and no longer servicing generator as intended. Vsl to replace with suitable connection fittings. 46 CFR 182.20-40(a)(2) 16c
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Replaced fittings a dirested, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Two breakers in electrical panel found with broken handles. Vsl to replace with new breakers. 46 CFR 183.05-30 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 26 September 2019
Resolution: Breakers have been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Vsl has many appliances in the main parlor powered by portable electrical cords. Vsl using extension cord to power fuel oil pump running from outlet in parlor to engine room. Vsl to install permanent outlets properly rated to handle load. 46 CFR 183.01-5 46 CFR 183.10-20(a)(2) 50c
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 11 October 2019
Resolution: Installed designated outlets for equipment as directed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Distribution panel was discovered with multiple dead end wires. The panel door was also pushing against wires causing damage. Many wires were also found with sharp bends. Vsl to remove all dead end wires throughout vsl, rewire to remove sharp bends. 46 CFR 183.01-15 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 11 October 2019
Resolution: Removed all dead end wires, sharp bends as directed , all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2019 Resolved
No machinery guards on port or stbd main engine rotating belts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2019
Resolved 14 February 2019
Resolution: Machinery guards properly installed on both port and stbd main engine rotating belts.
Engineering › Fuel Oil Service System › Valve
Issued 18 March 2010 Resolved
Install shutoff valves in the fuel oil supply piping to the ship service generator diesel engine as required by 46 CFR 182.20-40(b)(3) to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Due 18 April 2010
Resolved 5 April 2012
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 March 2010 Resolved
Provide two additional adult life jackets for a total of twenty-one adult life jackets as required by 46 CFR 180.25-5(a).
Due 18 March 2010
Resolved 18 March 2010
Resolution: Two additional adult life jackets were provided, examined, and found to be in satisfactory condition.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 18 March 2010 Resolved
Renew worn and deteriorated retro-reflective material to three adult life jackets as required by 46 CFR 180.25-25 to the satisfaction of the attending marine inspector.
Due 18 March 2010
Resolved 18 March 2010
Resolution: The retro-reflective material was installed on the three adult life jackets and were found to be in compliance with 46 CFR 180.25-25.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 February 2010 Resolved
Wires on forward transverse bulkhead were loose and needed to be re-attached or removed.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2010
Construction/Loadline › Hull › Side Shell
Issued 16 February 2010 Resolved
Numerous blisters in side shell gel coat were noted on the vesssel and marked for repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 February 2010
Engineering › Steering Gear System › Ram
Issued 16 February 2010 Resolved
Missing jam nut on steering ram cross bar.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2010
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 February 2010 Resolved
Corroded wiring on bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 February 2010
Fire Fighting › Ventilation Systems › Ducts
Issued 21 April 2009 Resolved
Provide ventilation shut down for engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 21 April 2009 Resolved
Demonstrate proper operation of aft engine room high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2009
Engineering › Fuel Oil Service System › Hose
Issued 21 April 2009 Resolved
Plug auxiliary fuel line from diesel tank and demonstrate proper operation of emergency fuel shut down devices.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 April 2009
Documentation › Markings/Placards › Warning Signs
Issued 21 April 2009 Resolved
Relabel emergency escape hatch on bow.
Due 5 May 2009
Resolved 23 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 March 2007 Resolved
Replace retro-tape on 7 adult and 1 child PFD. 2 Type II Child PFD's removed from the vessel.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 March 2007 Resolved
Label new lifering buoy with vessel name.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Communications › Radio Communications › EPIRB
Issued 22 March 2007 Resolved
Replace the expired hydrostatic release and mount the EPIRB in a float free conditon.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Construction/Loadline › Structures › Superstructure
Issued 22 March 2007 Resolved
Label upper deck "No passengers" or "Crew Only".
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2007 Resolved
Move stern light to a visible location iaw the COLREGS.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 March 2007 Resolved
Replace clouded navigation lens port/stbd. COLREGS
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 March 2007 Resolved
Replace or repair if enough length of hose is still available, portside main engine rawwater hose. Noted to be rotted iwo clamped area.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Fire Fighting › Ventilation Systems › Ducts
Issued 22 March 2007 Resolved
Make engine room vapor tight. Noted large open area below aft access door to engine room.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 22 March 2007 Resolved
Label bilge alarms and repair forepeak and lazarette visual alarms.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 22 March 2007 Resolved
Obtain current light list, tide/current tables, & navigation rules. Current extracts allowable.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 22 March 2007 Resolved
Replace or label Emergency Broadcast Placard. Noted to be faded and incomplete.
Action required: 705 - Other - as specified
Due 22 April 2007
Resolved 10 April 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 March 2007 Resolved
Conduct and log required drills. Last drills noted to be Fall of 2006.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 3 April 2006 Resolved
Conduct and log required drills and EPIRB tests as required by 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2006
Resolved 10 April 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 3 April 2006 Resolved
Provide updated tide tables as required by 46 CFR 184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2006
Resolved 10 April 2006
Construction/Loadline › Penetrations › Gasket
Issued 8 March 2006 Resolved
Replace hatch and gasket in the lazarette and prove watertight integrity.
Action required: 705 - Other - as specified
Due 8 April 2006
Resolved 15 March 2006
Resolution: Replaced hatch and gasket in the lazarette and prove watertight integrity.
Construction/Loadline › Hull › Transverse Frame
Issued 8 March 2006 Resolved
Replace transverse beam in the engine room above engines. Aft of engine beams.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 15 March 2006
Resolution: Replaced transverse beam in the engine room above engines.
Engineering › Steering Gear System › Bracket/Clamp
Issued 8 March 2006 Resolved
Replace four shaft log clamps.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 15 March 2006
Resolution: Replaced four shaft log clamps.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 March 2005 Resolved
Demonstrate proper operation of fixed fire fighting system automatic shutdown of port and starboard propulsion engines. (46 CFR 182.465).
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2005
Resolved 5 April 2005
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 March 2005 Resolved
Provide current copies or excerpts from navigation safety publications required by 46 CFR 184.420
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 5 April 2005
Lifesaving › Buoyant Apparatus › Painter
Issued 16 March 2005 Resolved
Replace painter for buoyant apparatus. (46 CFR 180.200)
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 5 April 2005
Engineering › Fuel Oil Service System › Hose
Issued 16 March 2005 Resolved
Remove hose clamps that rely on spring tension for clamping force from auxiliary generator fuel oil flexible hose assemblies. (46 CFR 182.720).
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 5 April 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 16 March 2005 Resolved
Install suitable guards for lighting fixtures in main salon overhead. (46 CFR 183.410).
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 5 April 2005
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 16 March 2005 Resolved
Replace broken electrical outlet cover in machinery space. (46 CFR 183.340).
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 5 April 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 March 2005 Resolved
Install emergency lighting in all passenger accommodation space located below the main deck in accordance with 46 CFR 183.432.
Action required: 705 - Other - as specified
Due 16 April 2005
Resolved 5 April 2005
Engineering › Steering Gear System › Bracket/Clamp
Issued 16 March 2005 Resolved
Make proper permanent repairs to hydraulic ram mounting bracket fractured in way of mounting bolt holes.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 April 2006
Resolved 5 April 2005
Resolution: Temporary repairs allowed until next scheduled dry dock.
Documentation › Manifests/Lists
Issued 15 April 2003 Resolved
Provide emergency instruction list. LEGACY COMPONENT DESC: Muster List/Emergency Instructions
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided Emergency instruction list.
Navigation › Piloting/Steering
Issued 15 April 2003 Resolved
Provide current charts and publications, i.e., coast pilot, light list, tide tables, tidal current tables and rules of the road. LEGACY COMPONENT DESC: Marine Charts
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided current charts and pubs.
Navigation › Collision/Grounding Avoidance
Issued 15 April 2003 Resolved
Replace lens on port and stbd running lights. LEGACY COMPONENT DESC: Navigation Lights
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner replaced lenses on port and stbd nav lights.
Communications › Radio Communications
Issued 15 April 2003 Resolved
Provide operational test of single side band radio.
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided operational test of SSB.
Communications › Radio Communications
Issued 15 April 2003 Resolved
Provide emergency broadcast placard.
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided Emergency broadcast placard.
Stability › Watertight Integrity
Issued 15 April 2003 Resolved
Provide gasket and make forepeak access hatch watertight. LEGACY COMPONENT DESC: Forepeak Hatch
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided gasket and made forepeak access hatch watertight.
Lifesaving › Liferaft Equipment
Issued 15 April 2003 Resolved
Provide 4' long paddles for lifefloat. LEGACY COMPONENT DESC: Paddle
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided 4'' paddles.
Communications › Alarms/Indicators
Issued 15 April 2003 Resolved
Replace and label high level bilge alarm for lazarette. LEGACY COMPONENT DESC: High Water Alarm
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner replaced and labeled high level alarm for lazarette.
Electrical › Electric Generation Source (service)
Issued 15 April 2003 Resolved
Provide derating of A/C generator and placard. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 22 May 2003
Resolution: Owner provided derating of A/C generator.
Fire Fighting
Issued 2 August 2000 Resolved
PROVIDE SERVICING REPORT FOR FIXED FIRE EXTINGUISHING SYSTEM PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 August 2000
Resolved 7 August 2000
Fire Fighting
Issued 2 August 2000 Resolved
PROVE PROPER OPERATION OF THE FIXED FIRE SYSTEM ENGINE SHUT DOWN FOR THE GENERATOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 August 2000
Resolved 7 August 2000
Electrical
Issued 2 August 2000 Resolved
PROVIDE AMP, VOLT AND FREQUENCY METER FOR THE GENERATOR. 46 CFR 183.10-5
Condition: Unknown
Due 2 August 2000
Resolved 2 August 2000
Lifesaving
Issued 2 August 2000 Resolved
PROVIDE VALID REGISTRATION FOR THE EPIRB. 46 CFR 180.64.
Condition: Unknown
Due 2 August 2000
Resolved 2 August 2000
Electrical
Issued 2 August 2000 Resolved
PROVIDE PORTABLE LIGHTS FOR THE CONRTROL STATION AND ENGINE ROOM AS PER 46 CFR 183.430
Condition: Unknown
Due 2 August 2000
Resolved 2 August 2000
Fire Fighting
Issued 2 August 2000 Resolved
PROVIDE SMOKE DETECTOR FOR THE FORWARD ACCOMADATION SPACE. 46 CFR 181.450.
Condition: Unknown
Due 2 September 2000
Resolved 7 August 2000
Construction/Loadline
Issued 2 August 2000 Resolved
PROVIDE BILGE HIGH LEVEL ALARM FOR LAZARETTE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 August 2000
Resolved 7 August 2000
Navigation
Issued 2 August 2000 Resolved
PROVIDE CURRENT CHARTS AND PUBS AS PER 46 CFR 184.420.
Condition: Unknown
Due 2 August 2000
Resolved 2 August 2000
Documentation
Issued 18 June 1996 Resolved
PROVIDE DRILL LOG BOOK AND CONDUCT REQUIRED DRILL'S IAW 46 CFR 185.520 & 185.524 AND TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Documentation
Issued 18 June 1996 Resolved
PROVIDE COPY OF NEW T-BOAT REG'S (FEDERAL REGISTER - 46 CFR PART 170)
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Engineering
Issued 18 June 1996 Resolved
PROVE PROPER OPERATION OF PORT PROPULSION ENGINE TACHOMETER.
Condition: Unknown
Due 18 June 1996
Resolved 18 June 1996
Lifesaving
Issued 8 June 1995 Resolved
ATTACH PADDLES TO LIFE FLOAT.
Condition: Unknown
Due 8 July 1995
Resolved 17 July 1995
Electrical
Issued 8 June 1995 Resolved
INSTALL METAL WIRE CLAMPS FOR OVERHEAD WIRE RUNS IN ENGINE ROOM AT INTERVALS OF 18".
Condition: Unknown
Due 8 July 1995
Resolved 17 July 1995
Engineering
Issued 8 June 1995 Resolved
RE-STENCIL EMERGENCY FUEL SHUTOFF.
Condition: Unknown
Due 8 July 1995
Resolved 17 July 1995
Fire Fighting
Issued 8 June 1995 Resolved
PROVIDE SERVICE/INSPECTION TAGS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 July 1995
Resolved 17 July 1995
Navigation
Issued 5 July 1994 Resolved
PROVE PROPER OPERATION OF STARBOARD NAVIGATION LIGHT.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Documentation
Issued 5 July 1994 Resolved
OBTAIN VALID FCC OPERATORS LICENSE.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 5 July 1994 Resolved
REPLACE GLASS SAFETY COVER ON ENGINE ROOM LIGHT FIXTURE.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Fire Fighting
Issued 16 June 1993 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 16 June 1993 Resolved
PROVIDE -4- FOOT PADDLES THAT ATTACH TO SIDES OF LIFE FLOAT.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Electrical
Issued 16 June 1993 Resolved
INSTALL COVERS OVER BATTERY TERMINALS TO PREVENT SHORTING FROM FALLING OBJECTS.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Electrical
Issued 16 June 1993 Resolved
RENEW BATTERY BOX TO PORT BATTERY INSTALLATION.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Lifesaving
Issued 16 June 1993 Resolved
MARK RING LIFE BUOY WITH VESSELS NAME.
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Construction/Loadline
Issued 17 June 1992 Resolved
INSTALL RIGID PIPING TO (3) INDIVIDUAL ELECTRIC BILGE PUMPS (AT LEAST SCHEDULE 40) ONE SHORT SECTION OF HOSE ALLOWED.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Construction/Loadline
Issued 17 June 1992 Resolved
MAKE VALVE TO COLLISION BULKHEAD DRAIN ACCESSIBLE UNDER NORMAL SERVICE CONDITIONS.
Condition: Unknown
Due 17 June 1992
Resolved 17 June 1992
Unknown
Issued 10 August 1988 Resolved
STENCIL VESSEL NAME ON BOTH LIFE FLOAT RING BUOYS.
Condition: Unknown
Due 10 August 1988
Resolved 10 August 1988
Unknown
Issued 10 August 1988 Resolved
REMOVE EX VESSEL NAME AND STENCIL "DAYBREAK" ON ALL 20 PFD'S.
Condition: Unknown
Due 10 August 1988
Resolved 10 August 1988
Unknown
Issued 10 August 1988 Resolved
RE-STENCIL LOCATION OF REMOTE F.O.S.O. VALVE ACCESS COVER IN COCKPIT AREA.
Condition: Unknown
Due 10 August 1988
Resolved 10 August 1988
Documentation
Issued 11 August 1987 Resolved
PROVIDE VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 11 August 1987
Resolved 11 August 1987

Casualty record · 1

31 October 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3358358
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SUNRISE (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.