Records from 2008 to 2026. Most recent: inspection, 11 February 2026.
Inspection history · 30
11 February 2026
Administrative Inspection · COI Inspection · Vessel Attendance · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304765
19 December 2025
Drydock Exam · Administrative Inspection · Vessel Attendance · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285597
3 September 2025
Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226475
10 February 2025
Annual Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077479
29 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7904855
12 February 2024
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864387
6 December 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7834548
9 November 2023
Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7824509
14 April 2023
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7668743
20 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7653934
27 July 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7517591
11 May 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7449919
5 April 2022
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426600
7 February 2022
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7415585
29 July 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7271435
18 March 2021
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7152737
10 June 2020
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6974305
26 May 2020
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6961188
17 March 2020
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6947232
13 February 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6908651
25 September 2019
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822592
6 August 2019
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6775225
5 February 2019
Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620260
23 October 2018
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570727
24 May 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6416956
6 March 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364938
23 March 2017
Damage Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105448
26 April 2016
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5875547
29 March 2016
Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5842297
19 January 2016
Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5799398
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2023
Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 April 2023
Resolution: Interconnected fire detection provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023
Resolved
Inspect machinery. Stbd shaft stern tube clamps were unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2023
Resolved 21 March 2023
Resolution: Clamps renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Properly secure Bridge wiring. Dead end cable above operating station has loose, frayed, and exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Dead end cable made up properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Label switchboard breakers with labels. Provide proof of proper labeling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Breakers labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Correctly install Voltmeter and Frequency Meter for Generator.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2021
Resolved 29 July 2021
Resolution: Marine inspector arrived at the vessel to ensure proper installation of the voltmeter and frequency meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021
Resolved
Demonstrate Fireboy Main Diesel Engine Over-ride working satisfactorily. Operator could not operate Override system due to potential error with system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2021
Resolution: Override operationally.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021
Resolved
Remove vice-grip pliers on Battery Box under the Operating Station. Provide proof of safe and operational electrical installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2021
Resolution: Vice grips removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021
Resolved
Collision blkhd has sluice valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Valve removed, penetration capped.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 March 2021
Resolved
Ensure and provide proof of Emergency Lighting installation on the Main Deck of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Emergency light renewed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2020
Resolved
Forward engine room bilge alarm is inoperable. Repair or replace forward engine room bilge alarm to, and provide evidence of satisfactory operating condition. Vessel is restricted from carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2020
Resolved 10 June 2020
Resolution: Replaced wiring to bilge alarm and provided satisfactory evidence of visual and audible alarm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2020
Resolved
Masthead light inoperable. Repair or replace masthead light. Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2020
Resolved 10 June 2020
Resolution: Replaced masthead light and provided evidence of satisfactory operation.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 June 2020
Resolved
Guards around rotating machinery in engine room not installed. Install guards around rotating machinery in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Guards installed on engines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 June 2020
Resolved
Hatch to lazarette found to have nuts and washers missing on 2 of the dogging arms, preventing the hatch from securing. Repair or replace dogging arms on hatch to ensure that the hatche secures when closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 June 2020
Resolution: Replaced washers and nuts and provided evidence of satisfactory operation of the hatch locking shut.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 June 2020
Resolved
Shaft packing around port shaft found to be excessively leaking. Tighten or replace shaft packing around port shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Replaced shaft packing on both port and starboard shafts.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 June 2020
Resolved
Smoke alarm missing from secondary passenger berthing location. Install appropriate UL 217 smoke alarm in the passenger berthing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Second smoke detector installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 June 2020
Resolved
Alcohol test strips on board found to be expired. Provide current alcohol test strips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2020
Resolved
There was no separation of adult life jackets to child life jackets in storage compartment. Install separator or divider in life jacket stowage location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Operator separated stowage of adult and child life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2020
Resolved
No light list found on board. Provide current light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019
Resolved
Vsl req'd to have emergency exits marked EMERGENCY EXIT - KEEP CLEAR. On both sies vsl missing KEEP CLEAR. Vsl to provide additional wording.
46 CFR 177.15
10c
Action required: 10 - Deficiency Rectified
Due 25 September 2019
Resolved 25 September 2019
Resolution: Vsl placed wording on both sides of the emergency exit to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019
Resolved
Life jackets are req'd for every passenger. One life jacket was unservicable. Vsl to replace jacket.
46 CFR 180.71(a)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Marine Inspector verified new life jackets on board with proper markings and light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019
Resolved
Life jackets are req'd to be marked with retroreflective material. Three lifejackets did not have servicable tape installed. Vsl to replace retroreflective tape.
46 CFR 185.604(i)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced retroreflective tape to the satisfation of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2019
Resolved
Life ring is req'd to be marked with vessel name and have a line resistant to deterioration. Life ring is not marked w/ vessel name and line is severly deteriorated.
46 CFR 185.604(b)
46 CFR 180.70(b)(1)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel added name of vessel to the life ring and replaced the attached grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2019
Resolved
The waterlight is req'd to have a 3ft line attached resistant to deterioration. The line attached to the waterlight is severely deteriorated.
46 CFR 180.70(d)(2)
701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced the line on the waterlight with a 3 foot line attached to the body of the ring buoy with a corrosion resistant clip.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2019
Resolved
Vsl is required to have emergency instructions posted of actions to take in the event of fire, heavy weather, or man overboard. Vsl is missing these instructions.
46 CFR 185.510
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Posted emergency instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2019
Resolved
Fuel filter on starboard generator found leaking. Vsl to repair or replace.
46 CFR 182.20-40
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Replaced fuel oil filter, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2019
Resolved
Multiple flexible hose fittings on stbd generator are backing out and no longer servicing generator as intended. Vsl to replace with suitable connection fittings.
46 CFR 182.20-40(a)(2)
16c
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Replaced fittings a dirested, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Two breakers in electrical panel found with broken handles. Vsl to replace with new breakers.
46 CFR 183.05-30
16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 26 September 2019
Resolution: Breakers have been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Vsl has many appliances in the main parlor powered by portable electrical cords. Vsl using extension cord to power fuel oil pump running from outlet in parlor to engine room. Vsl to install permanent outlets properly rated to handle load.
46 CFR 183.01-5
46 CFR 183.10-20(a)(2)
50c
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 11 October 2019
Resolution: Installed designated outlets for equipment as directed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019
Resolved
Distribution panel was discovered with multiple dead end wires. The panel door was also pushing against wires causing damage. Many wires were also found with sharp bends. Vsl to remove all dead end wires throughout vsl, rewire to remove sharp bends.
46 CFR 183.01-15
50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 11 October 2019
Resolution: Removed all dead end wires, sharp bends as directed , all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2019
Resolved
No machinery guards on port or stbd main engine rotating belts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2019
Resolved 14 February 2019
Resolution: Machinery guards properly installed on both port and stbd main engine rotating belts.