OUTTA LINE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in February 2026, along with 30 deficiencies and 1 casualty investigation in 2008.

Records from 2008 to 2026. Most recent: inspection, 11 February 2026.

Built
1986
Last inspected
11 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 February 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ4492
271952
Flag
UNITED STATES
Maury page id
psix-271952

Documentation record

Registered dimensions (L × B × D)53.0 ft × 17.0 ft × 10.0 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderG & S BOATS · DESTIN, FL, UNITED STATES · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 3 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

11 February 2026 Administrative Inspection · COI Inspection · Vessel Attendance · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304765
19 December 2025 Drydock Exam · Administrative Inspection · Vessel Attendance · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285597
3 September 2025 Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8226475
10 February 2025 Annual Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077479
29 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7904855
12 February 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864387
6 December 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7834548
9 November 2023 Special · Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7824509
14 April 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7668743
20 March 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7653934
27 July 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7517591
11 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7449919
5 April 2022 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7426600
7 February 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7415585
29 July 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7271435
18 March 2021 Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7152737
10 June 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6974305
26 May 2020 Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6961188
17 March 2020 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6947232
13 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6908651
25 September 2019 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6822592
6 August 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6775225
5 February 2019 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620260
23 October 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570727
24 May 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6416956
6 March 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364938
23 March 2017 Damage Survey · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6105448
26 April 2016 Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5875547
29 March 2016 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5842297
19 January 2016 Deficiency Check · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5799398

Deficiency record · 30

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2023 Resolved
Vessel required to have interconnected fire detection system that meet specific requirements in 46CFR181.450. Vessel did not have onboard or installed interconnected fire detection system. Vessel limited to Limited Coastwise until fire detection system installed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 April 2023
Resolution: Interconnected fire detection provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2023 Resolved
Inspect machinery. Stbd shaft stern tube clamps were unsatisfactory.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 April 2023
Resolved 21 March 2023
Resolution: Clamps renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Properly secure Bridge wiring. Dead end cable above operating station has loose, frayed, and exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Dead end cable made up properly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Label switchboard breakers with labels. Provide proof of proper labeling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Breakers labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Correctly install Voltmeter and Frequency Meter for Generator.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2021
Resolved 29 July 2021
Resolution: Marine inspector arrived at the vessel to ensure proper installation of the voltmeter and frequency meter.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2021 Resolved
Demonstrate Fireboy Main Diesel Engine Over-ride working satisfactorily. Operator could not operate Override system due to potential error with system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2021
Resolution: Override operationally.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 March 2021 Resolved
Remove vice-grip pliers on Battery Box under the Operating Station. Provide proof of safe and operational electrical installation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2021
Resolution: Vice grips removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2021 Resolved
Collision blkhd has sluice valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Valve removed, penetration capped.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 18 March 2021 Resolved
Ensure and provide proof of Emergency Lighting installation on the Main Deck of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2021
Resolved 23 March 2021
Resolution: Emergency light renewed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 June 2020 Resolved
Forward engine room bilge alarm is inoperable. Repair or replace forward engine room bilge alarm to, and provide evidence of satisfactory operating condition. Vessel is restricted from carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 June 2020
Resolved 10 June 2020
Resolution: Replaced wiring to bilge alarm and provided satisfactory evidence of visual and audible alarm.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2020 Resolved
Masthead light inoperable. Repair or replace masthead light. Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2020
Resolved 10 June 2020
Resolution: Replaced masthead light and provided evidence of satisfactory operation.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 June 2020 Resolved
Guards around rotating machinery in engine room not installed. Install guards around rotating machinery in the engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Guards installed on engines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 June 2020 Resolved
Hatch to lazarette found to have nuts and washers missing on 2 of the dogging arms, preventing the hatch from securing. Repair or replace dogging arms on hatch to ensure that the hatche secures when closed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 June 2020
Resolution: Replaced washers and nuts and provided evidence of satisfactory operation of the hatch locking shut.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 10 June 2020 Resolved
Shaft packing around port shaft found to be excessively leaking. Tighten or replace shaft packing around port shaft.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Replaced shaft packing on both port and starboard shafts.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 10 June 2020 Resolved
Smoke alarm missing from secondary passenger berthing location. Install appropriate UL 217 smoke alarm in the passenger berthing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Second smoke detector installed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 10 June 2020 Resolved
Alcohol test strips on board found to be expired. Provide current alcohol test strips.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 July 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2020 Resolved
There was no separation of adult life jackets to child life jackets in storage compartment. Install separator or divider in life jacket stowage location.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 23 June 2020
Resolution: Operator separated stowage of adult and child life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2020 Resolved
No light list found on board. Provide current light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2020
Resolved 10 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2019 Resolved
Vsl req'd to have emergency exits marked EMERGENCY EXIT - KEEP CLEAR. On both sies vsl missing KEEP CLEAR. Vsl to provide additional wording. 46 CFR 177.15 10c
Action required: 10 - Deficiency Rectified
Due 25 September 2019
Resolved 25 September 2019
Resolution: Vsl placed wording on both sides of the emergency exit to the satisfaction of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019 Resolved
Life jackets are req'd for every passenger. One life jacket was unservicable. Vsl to replace jacket. 46 CFR 180.71(a) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Marine Inspector verified new life jackets on board with proper markings and light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 September 2019 Resolved
Life jackets are req'd to be marked with retroreflective material. Three lifejackets did not have servicable tape installed. Vsl to replace retroreflective tape. 46 CFR 185.604(i) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced retroreflective tape to the satisfation of the attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2019 Resolved
Life ring is req'd to be marked with vessel name and have a line resistant to deterioration. Life ring is not marked w/ vessel name and line is severly deteriorated. 46 CFR 185.604(b) 46 CFR 180.70(b)(1) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel added name of vessel to the life ring and replaced the attached grab line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2019 Resolved
The waterlight is req'd to have a 3ft line attached resistant to deterioration. The line attached to the waterlight is severely deteriorated. 46 CFR 180.70(d)(2) 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2019
Resolved 26 September 2019
Resolution: Vessel replaced the line on the waterlight with a 3 foot line attached to the body of the ring buoy with a corrosion resistant clip.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2019 Resolved
Vsl is required to have emergency instructions posted of actions to take in the event of fire, heavy weather, or man overboard. Vsl is missing these instructions. 46 CFR 185.510 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Posted emergency instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2019 Resolved
Fuel filter on starboard generator found leaking. Vsl to repair or replace. 46 CFR 182.20-40 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Replaced fuel oil filter, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 September 2019 Resolved
Multiple flexible hose fittings on stbd generator are backing out and no longer servicing generator as intended. Vsl to replace with suitable connection fittings. 46 CFR 182.20-40(a)(2) 16c
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 11 October 2019
Resolution: Replaced fittings a dirested, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Two breakers in electrical panel found with broken handles. Vsl to replace with new breakers. 46 CFR 183.05-30 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2019
Resolved 26 September 2019
Resolution: Breakers have been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Vsl has many appliances in the main parlor powered by portable electrical cords. Vsl using extension cord to power fuel oil pump running from outlet in parlor to engine room. Vsl to install permanent outlets properly rated to handle load. 46 CFR 183.01-5 46 CFR 183.10-20(a)(2) 50c
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 11 October 2019
Resolution: Installed designated outlets for equipment as directed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 September 2019 Resolved
Distribution panel was discovered with multiple dead end wires. The panel door was also pushing against wires causing damage. Many wires were also found with sharp bends. Vsl to remove all dead end wires throughout vsl, rewire to remove sharp bends. 46 CFR 183.01-15 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2019
Resolved 11 October 2019
Resolution: Removed all dead end wires, sharp bends as directed , all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 February 2019 Resolved
No machinery guards on port or stbd main engine rotating belts.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 February 2019
Resolved 14 February 2019
Resolution: Machinery guards properly installed on both port and stbd main engine rotating belts.

Casualty record · 1

31 October 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3358358
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SUNRISE (2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.