Records from 2016 to 2026. Most recent: inspection, 17 June 2026.
Inspection history · 34
17 June 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8407088
11 December 2025
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8279715
11 June 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8157463
30 May 2025
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8152893
21 August 2024
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7986119
20 June 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7927532
3 May 2024
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7907515
12 March 2024
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7877613
2 November 2023
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7819698
5 October 2023
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7804216
27 July 2023
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7675354
4 July 2023
Type not recorded
No type recorded · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 7758341
16 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7671087
10 January 2023
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7647648
2 August 2022
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7500588
2 June 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7454511
25 May 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7459058
20 April 2022
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7427271
1 April 2022
COI Inspection · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7411668
17 August 2021
In-Service Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7289247
17 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7219753
23 July 2020
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit · MTSA Verification
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6986708
25 June 2020
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6979220
17 December 2019
Examination of Repairs · Drydock Exam · Construction Oversight · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6869989
28 July 2019
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6784237
18 June 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6704736
5 June 2018
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6434746
15 May 2018
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6409399
22 January 2018
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6347576
28 April 2017
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6124608
3 March 2017
COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6098569
14 February 2017
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6091855
16 June 2016
DAPI Audit · MTSA Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5885730
21 April 2016
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5854322
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 11 June 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Observed a standard electrical receptacle on the 01 Deck port side at table 10 damaged due to corrosion, heat. Replace damaged receptacle to satisfaction of attending Marine Inspector. 46 CFR 120.200(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 18 June 2025
Resolution: Receptacle renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 June 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Observed an electrical junction box in the 01 Deck concession stand with a missing cover and exposed live wires. Install proper electrical cover to satisfaction of attending Marine Inspector. 46 CFR 120.200(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2025
Resolved 25 June 2025
Resolution: Cover installed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
Gauge 02 deck plating identified as heavily pitted under old life jacket stowage. Crop and renew if wastage exceeds 25% original design scantling.
Prior to 1Jun2025
Action required: 705 - Other - as specified
Resolved 3 June 2025
Resolution: Cropped and renews the deck.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
Replace damaged SFP in store room and crew quarters
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: All areas have been replaced with new SFP.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
Replace Fire stop caulking in engine room penetration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Replace with new fire stop protection in engine room.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
02 Deck Repair 7 wasted frames
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: All frames have been cut back to good metal, replaced with new.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
03 Deck Repair 1 wasted frame
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Frame has been cut back to good metal, replaced with new.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
Repair wastage at 02 deck mens and womens head.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Deck in both heads has been replaced with good metal.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
Repair or replace wasted louvers to emergency generator space on 02 deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: New louvers have been fabricated and fitted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 12 March 2024
Resolved
Repair 4 holed deck drains from 03- 02 deck
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2024
Resolution: Replaced deck drains with new.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 October 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 October 2023
Resolved 2 November 2023
Resolution: Fire main repaired and hydrostatically tested to 150 PSI.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2023
Resolved
A vessel must have a sufficient number of fire hydrants to
reach any part of the vessel using a single length of fire hose. Fire main piping ruptured in the E/R rendering aft fire stations inoperable. Repair and prove proper operation of the fire main system to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 June 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 June 2023
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspections and your Certificate of Inspection must be endorsed. Conduct fire drills to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2022
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Port and STBD shaft seals are leaking excessively. Repair by 22 April 2022.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2022
Resolved 21 April 2022
Resolution: FACETIME W/OPS MNGR TIGHTENED PACKING, HAD BEEN LOOSENED UP DUE TO COMING OUT OF SHIPYARD.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2022
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of subchapter J of this chapter for a flexible cord or cable. No flexible cord may be used except as allowed under Sections 400-7 and 400-8 of NFPA NEC 2002. Extension cord used as cable mounted to ties for bridge refrigerator, remove.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 29 April 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 April 2022
Resolved
An exposed hazard, such as gears or rotating machinery, must be protected by a cover guard or rail. Install machinery guards over the aft pulleys on the vessel's hydraulic system prime mover.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2022
Resolved 29 April 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 April 2022
Resolved
t each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Engine room fire station #1 is obstructed by a tool chest and various equipment. Move the tool chest and all equipment to make fire station #1 fully accessible. BY 22APR22.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 April 2022
Resolved 21 April 2022
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 1 April 2022
Resolved
Conduct man overboard in the presence of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 April 2022
Resolution: conducted u/w drill, pj ri
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 April 2022
Resolved
Conduct abandon ship drill in the presence of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2022
Resolved 29 April 2022
Resolution: conducted abandon ship walk thru simulation pj ri
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 April 2022
Resolved
Conduct fire fighting drill in the presence of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2022
Resolution: simulated electric vehicle fire frieght deck. pj ri.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 April 2022
Resolved
Steering alarm panel on the bridge not giving audible alarm for every alarm. #2 Steering pump not alarming during loss of phase. Demonstrate proper operation of alarm panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 20 April 2022
Resolution: tested alarms, sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 April 2022
Resolved
#7 and #10 fire nozzles not working as design. Repair or replace required nozzles a the above mentioned fire stations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 25 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 April 2022
Resolved
Resubmit DVTP/OFA for Cummins engines to MSC for modification to current approved procedures.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2022
Resolved 7 June 2022
Resolution: MSC Approval Ltr E2-2201884 dtd 07Jun22
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 June 2021
Resolved
Prove proper operation of fire doors 01 deck aft port and stbd. Doors do not close and latch properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 22 June 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 17 June 2021
Resolved
Seal up the holes in bulkheads in emergency generator space to meet fire control boundary requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 22 June 2021
14 - Pollution Prevention › N/A - No Subsystem › VGP: General
Issued 17 June 2021
Resolved
Drain valve for fuel oil containment area on the port side is seized. Repair or provide a proper mechanical plug for the drain.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 17 June 2021
Resolution: placed a new valve on the containment.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 June 2021
Resolved
Emergency generator is unable to take ships load. Vessel is restricted to less than 600 passengers. Prove proper operation of emergency generator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 17 June 2021
Resolution: Repaired emergency generator to allow it to take the load.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 July 2020
Resolved
Remove and or properly install lighting and electrical equipment in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2020
Resolved 24 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2020
Resolved
Install panel covers on switchboard in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2020
Resolved 24 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2020
Resolved
Install electrical matting at the base of switchboard in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 7 August 2020
Resolution: Placed matting at switchboard panel
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 July 2020
Resolved
Remove and or properly install light fixture in FM200 space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 24 July 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 July 2020
Resolved
Install emergency lighting in FM200 space, and in crew quarters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 1 September 2020
Resolution: E-lighting installed in crew & FM200 spaces.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 July 2020
Resolved
Replace worn fire hose starboard side mid-ship.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 July 2020
Resolved 24 July 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 July 2020
Resolved
Stencil hose stations and portable fire fighting locations in accordance with the Fire Control Plan.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 24 July 2020
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 23 July 2020
Resolved
Stencil emergency escape out of engine room to main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 24 July 2020
Resolution: Properly marked/stenciled emergency exit
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 23 July 2020
Resolved
Make boiler available for inspection and testing prior to operation.
Action required: 705 - Other - as specified
Due 24 July 2020
Resolved 1 September 2020
Resolution: Conducted boiler inspection
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 July 2020
Resolved
Make fire control plan available for review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 1 September 2020
Resolution: Reviewed & approved FCP
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 23 July 2020
Resolved
Passenger count placard missing on main deck. Install placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 7 August 2020
Resolution: Placard posted
08 - Alarms › N/A - No Subsystem › General alarm
Issued 23 July 2020
Resolved
General alarm placard missing. Install placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 7 August 2020
Resolution: Placard posted
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 23 July 2020
Resolved
Missing Coast Pilot and Lightlist publications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 7 August 2020
Resolution: Coast Pilot and Light List printed out
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2020
Resolved
Repair/tighten packing on fire hydrant valves that show signs of leaking.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2020
Resolved 7 August 2020
Resolution: Packing tightened down. Hydrant tested sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 July 2020
Resolved
Properly install junction box cover on 03 deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2020
Resolved 24 July 2020
Resolution: Junction box properly tightened up
Communications › Alarms/Indicators › General Alarm
Issued 5 June 2018
Resolved
The focsle deck general alrm bell did not ring. Repaired prior to the end of the inspection.
Action required: 10 - Deficiency Rectified
Due 15 June 2018
Resolved 15 June 2018
Fire Fighting › Fire Main › Pressure
Issued 5 June 2018
Resolved
Unclog the port aft main deck fire station piping. Completed prior to the completion of the exam.
Action required: 10 - Deficiency Rectified
Due 15 June 2018
Resolved 15 June 2018
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 4 April 2017
Resolved
Install fire stop between decks at electrical penetrations.
Due 5 May 2017
Resolved 18 April 2017
Resolution: Fire stop installed.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 4 April 2017
Resolved
Demonstrate all alarms and shutdowns on emergency generator.
Due 5 May 2017
Resolved 18 April 2017
Resolution: Shutdowns and alarms tested sat.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 4 April 2017
Resolved
Replace drain valve on port overflow containment.
Due 5 May 2017
Resolved 18 April 2017
Resolution: Valve replaced.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 April 2017
Resolved
Demonstrate low hydraulic level alarm on steering pumps 1 & 2.
Due 5 May 2017
Resolved 18 April 2017
Resolution: Alarms demonstrated.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 April 2017
Resolved
Conduct drills (fire, man overboard and security).
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2017
Resolved 28 April 2017
Resolution: Completed required drills.
Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 April 2017
Resolved
Repair steering system audible alarm in wheelhouse.
Due 5 May 2017
Resolved 26 April 2017
Resolution: Alarms repaired.
Communications › Public Address System › Loudspeaker
Issued 16 June 2016
Resolved
Aft speaker on aft mast and speaker outside emergency generator room are inoperable. Repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 June 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 16 June 2016
Resolved
Emergency lights for the IBAs are not wired into the emergency bus as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 22 June 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 16 June 2016
Resolved
Provide updated certificate for enrollment into the DAPI program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 18 June 2016