Records from 2002 to 2025. Most recent: inspection, 3 December 2025.
Inspection history · 19
3 December 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8274885
6 March 2025
Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8088900
10 September 2024
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7999942
7 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7706315
27 April 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7679614
18 April 2022
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7432937
21 April 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7179624
15 March 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7156564
2 December 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7105247
20 November 2019
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6858630
11 June 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6710960
23 October 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6564297
10 January 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6335756
21 August 2017
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6247122
6 June 2017
Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6188693
1 April 2017
Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6115592
1 April 2017
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6115702
13 March 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6104074
5 July 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5929895
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 3 December 2025
Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 181.405 (c) and 46 CFR 181.450 (a)(1), if it is not a ferry, and if it is operating on a Coastwise or Oceans route. Vessel did not have an interconnected smoke detection and alarm system in area where passengers and crew have routine access, including accommodation spaces and machinery spaces. Install interconnected smoke detectors that meet UL 217 rating in enclosed areas where passengers and crew have routine access and machinery spaces to the satisfaction of the local OCMI. Vessel is restricted to limited Coastwise route.
Action required: 705 - Other - as specified
Resolved 12 January 2026
Resolution: Photos been recieved, all Sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 October 2024
Resolved
"(a) All life preservers shall be of an approved type.(b) All kapok and fibrous glass life preservers which do not have plastic covered pad inserts, as required by
subparts 160.002 and 160.005 of Subchapter Q of this
chapter, shall be removed from service." 30 adult life jackets and 7 child life jackets were removed from service. Replace prior to taking 114 Adults/8 children.
Action required: 705 - Other - as specified
Resolved 3 December 2025
Resolution: All required life jackets has been accounted for. Vessel purchased new life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 October 2024
Resolved
"All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a)." One of the two required bilge pumps was found inoperable due to STBD ME undergoing maintenance at the time of the inspection. Both bilge pumps must be fully operational prior to taking passenger.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 10 September 2024
Resolved
"Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date..." Vessel has lapsed on annual inspection date. Issued prior to passenger prior to rectifying.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2024
Resolution: issued COI
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 September 2024
Resolved
"Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which
it is installed and capable of operating at constant marine load" Injector that was replace during routine maintenance failed. STBD ME was inop at the time of the inspection. STBD ME must be capable of operating prior to taking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 October 2024
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 June 2023
Resolved
"Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate." Vessel sent EPIRB for servicing, currently not operating with an EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2023
Resolved 21 June 2023
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 7 June 2023
Resolved
"Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF–DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz...." Vessels MF-DSC Frequency transmitter is no operational. Vessel will be restricted to no more than 20 nautical miles.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 June 2023
Resolved 21 June 2023
Resolution: Restruced 20 nautical miles
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 7 June 2023
Resolved
"Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system." Vessel's public address system is inoperable.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 21 June 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2023
Resolved
"Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended." Vessels starboard engine does not automatically shutoff when the engine shutoff is pressed on the bridge. Vessel still has two means to stop the starboard engine.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 June 2023
Resolved 21 June 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 June 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Donning instructions were not posted on the upper deck of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2023
Resolved 21 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 April 2021
Resolved
46 cfr 184.710 A vessel must carry a first aid kit approved under approval series 160.041 or a kit with equivalent contents.
Action required: 10 - Deficiency Rectified
Due 22 April 2021
Resolved 22 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019
Resolved
Junction boxes,connection boxes, and outlet boxes for use in in damp or wet locations shall be of watertight instruction. Provide watertight enclosure for bilge pump wiring in lazerette.
46 CFR 183.10-20(k)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: Recieved picture of correction
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 November 2019
Resolved
On a vessel of more than 65ft in length, the public address system must be fixed installation and be audible during normal operating conditions throughout all accommodation spaces. Vessel was missing PA speaker on main deck accommodation area.
46 CFR 184.610 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: Recieved picture of new PA speaker
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 November 2019
Resolved
A hatch exposed to the weather must be watertight and have securing device. Watertight hatch for fore peak was missing securing device and gasket needs replaced.
46 CFR 179.360
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: recieved picture of hatch with securing device
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 November 2019
Resolved
Owner or operator must provide satisfactory evidence of the required servicing to a marine inspector. No servicing inspection report of fixed fire extinguishing was on board.
46 CFR 176.810(b)(iv)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: Recieved pictures of servicing reports
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other person and the vessel from electrical hazard, including fire, caused by or originating in electrical equipment and electrical shock. Covers on electrical enclosures in Engine room were missing.
46 CFR 183.200 (b)
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: Recieved pictured of enclosures
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 November 2019
Resolved
At each inspection all observed unsafe practices, fire hazards must be corrected and all required quards and protective devices must be in satisfactory condition. Vessel guard on stbd MDE was loose and rubbing against the belt. Seals on stbd and middle MDE are leaking oil.
46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: Recieved picture of proper placement of belt guard
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 20 November 2019
Resolved
The owner shall instruct members prior to getting underway and employment as to the duties that the crewmember is expected to perform in an emergency. Vessel crew did not have CPR training as per NVIC 01-91 which requires minimum of 50% of required deckhands must have.
46 CFR 185.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 December 2019
Resolved 19 December 2019
Resolution: Recieved email with crew enrollment in CPR class for Dec 14th.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 October 2018
Resolved
A VESSEL OF GREATER THAN 65 FEET SHALL CARRY A MINIMUM OF THREE LIFE BUOYS. TWO OF THE VESSELS THREE LIFE BUOYS WERE UNSERVICEABLE.
46CFR180.70(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 5 November 2018
Resolution: Two new life buoys were purchased.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 October 2018
Resolved
EACH SHIP TRANSPORTING MORE THAN SIX PASSENGERS FOR HIRE EQUIPPED WITH A RADIOTELEPHONE STATION, THE RADIO OPERATOR MUST HOLD A MARINE RADIO OPERATOR PERMIT. EACH RADIO OPERATOR MUST OBTAIN A RADIO OPERATORS PERMIT.
47CFR80.159
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 5 November 2018
Resolution: The vessel captain has an indefinite validity on his MROP. A copy showing this was produced for the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 October 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2018
Resolved 5 November 2018
Resolution: The vesssel had vaild means of testing for alcohol on board.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 August 2017
Resolved
Prior to operating conduct MOB drill.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: attended vessel to witness drilld
Communications › Radio Communications › EPIRB
Issued 21 August 2017
Resolved
replace expired battery
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Attended vessel verified the battery was replaced
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 August 2017
Resolved
replace 32 life jackets
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Attended vessel verified life jackets were replaced
Fire Fighting › Fire Pumps › Pressure
Issued 21 August 2017
Resolved
demonstrate operation of the fire/bilge pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 August 2017
Resolution: Verified operation
Electrical › Electric Generation Source (service) › Conductor
Issued 21 August 2017
Resolved
Prior to installing a stove top submit a 1 line including wire and breaker size.
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 5 November 2018
Resolution: Vessel provided one-line.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 August 2017
Resolved
Reconnect overboard discharge for the head floor drains, bilge pump, and holding tank vents in the lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2017
Resolved 21 August 2017
Resolution: All overboard discharge conections are reconnected.
Engineering › Bilge Water Management System › Not Operational
Issued 4 August 2017
Resolved
Re-attach pilge pump and high level alarm in the lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2017
Resolved 21 August 2017
Resolution: Repairs complete.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 August 2017
Resolved
Seal center exhaust pipe at engine room WTB.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2017
Resolved 21 August 2017
Resolution: Repairs complete.
Construction/Loadline › Structures › Superstructure
Issued 4 August 2017
Resolved
Repair bulwarks cap rail at transom.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 August 2017
Resolved 21 August 2017
Resolution: Repairs complete.
Stability › Watertight Integrity › General
Issued 1 April 2017
Resolved
Vessel is restricted from carrying passengers until drydock inspection is completed by USCG and vessel is tructurally intact.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2017
Resolution: All dry dock items and repairs are complete.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 March 2017
Resolved
Replace exhaust system from MDE's to transom.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2017
Resolved 21 August 2017
Resolution: Attended vessel verified exhaust system meets ABYC P1
Construction/Loadline › Penetrations › Valve Flange
Issued 13 March 2017
Resolved
Renew O/B discharge sea valve in Lazz.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2017
Resolved 21 August 2017
Resolution: Attended vessel, verified renewal.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 July 2016
Resolved
Provide repair proposal for exhaust pipes for M/E
Action required: 705 - Other - as specified
Due 30 July 2016
Resolved 21 August 2017
Resolution: Attended vessel, verified exhaust system has been replaced IAW ABYC P1
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 5 July 2016
Resolved
Provide proper labeling for storage and protected space of CO2
Action required: 705 - Other - as specified
Due 30 July 2016
Resolved 21 August 2017
Resolution: Attended vessel verified labeling.