MAURY USCG vessel records Sign in
← All vessels

USNS JOSHUA HUMPHREYS

USNS JOSHUA HUMPHREYS is a 1987 tank ship. The Coast Guard has recorded 156 inspections since 1987, most recently in March 2026, along with 166 deficiencies.

Records from 1987 to 2026. Most recent: inspection, 13 March 2026.

Built
1987
Last inspected
13 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8302428 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
272044
Flag
UNITED STATES
—
Maury page id
psix-272044

Inspections, by type

…with no type recorded42
Years with a record 29 calendar years (1987–2026)
The 156 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it25742 - Convention (Subpart B), Gross Ton
20706 - Regulatory (Subpart C or D), Gross Ton
8992 - Convention (Subpart B), Net Ton
18987 - Regulatory (Subpart C or D), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 156

13 March 2026 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8325749
12 March 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8328480
29 October 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8260537
27 October 2025 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8259114
13 October 2025 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8254211
17 September 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8236078
11 August 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 8209627
9 June 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8157764
24 April 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8118355
12 February 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8083637
10 February 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8077499
28 May 2024 ACP COI Oversight · Re-Inspection · Deficiency Check · ACP Drydock Oversight · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7921603
15 May 2024 Permit to Proceed
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7912787
8 May 2024 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7908449
20 April 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7898591
2 April 2024 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888390
2 April 2024 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7890596
14 February 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7873795
4 January 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7845397
29 December 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7843397
7 November 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7821120
22 April 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7673420
6 March 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7647459
6 January 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7620179
29 November 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7657506
12 August 2022 Periodic Inspection · ACP Drydock Oversight · Administrative Inspection · ACP Periodic Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7531680
2 July 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7493324
16 June 2022 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7478983
4 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7468230
26 January 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7386499
16 August 2021 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7307198
21 May 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7202765
31 March 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7165526
28 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7147632
11 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7139572
6 January 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7120974
25 August 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7042496
24 July 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7014778
3 February 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6901970
7 October 2019 Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 6830346
31 January 2019 Re-Inspection · Special · ACP Additional Oversight – Risk Assessment · ACP Drydock Oversight · Administrative Inspection · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6625802
23 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6566430
21 September 2018 ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6521372
9 July 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6520984
16 May 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6422277
3 May 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6430053
11 January 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6336037
14 January 2017 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6072108
14 January 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6077248
7 November 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6036480
13 October 2016 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6022245
18 August 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5983597
18 July 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5953170
8 June 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5905643
18 May 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5880092
22 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5859939
12 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5852165
8 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5849753
6 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5848189
4 April 2016 Type not recorded
No type recorded · Activities Europe · Activity 5848955
27 January 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5804149
11 January 2016 Type not recorded
No type recorded · Activities Europe · Activity 5800081
22 December 2015 Administrative Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 5785782
15 December 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5781756
22 October 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5762711
2 September 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5232826
21 August 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5222230
11 August 2015 Administrative Inspection
Administrative · Activities Europe · Activity 5212597
11 August 2015 Deficiency Check
Physical examination · Activities Europe · Activity 5233897
6 August 2015 Type not recorded
No type recorded · Activities Europe · Activity 5212422
27 July 2015 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Europe · Activity 5153850
6 October 2014 Administrative Inspection
Administrative · Activities Europe · Activity 4999801
3 October 2014 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 4998493
9 May 2014 Administrative Inspection
Administrative · Activities Europe · Activity 4857144
19 July 2012 Type not recorded
No type recorded · Activities Europe · Activity 4404573
25 June 2012 Type not recorded
No type recorded · Activities Europe · Activity 4360723
1 June 2012 Type not recorded
No type recorded · Activities Europe · Activity 4337451
10 May 2012 Type not recorded
No type recorded · Activities Europe · Activity 4310778
13 February 2012 Type not recorded
No type recorded · Activities Europe · Activity 4243962
5 January 2012 Type not recorded
No type recorded · Activities Europe · Activity 4219692
31 August 2011 Type not recorded
No type recorded · Activities Europe · Activity 4142624
5 August 2011 Annual Inspection
Physical examination · Activities Europe · Activity 4082310
30 January 2011 Type not recorded
No type recorded · Activities Europe · Activity 3940386
29 October 2010 Type not recorded
No type recorded · Activities Europe · Activity 3887087
25 October 2010 Deficiency Check
Physical examination · Activities Europe · Activity 3876967
24 October 2010 Type not recorded
No type recorded · Activities Europe · Activity 3876906
17 September 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3851973
19 March 2010 Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3698983
28 February 2006 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2593908
22 November 2005 Hull Examination · Internal Structural Exam · Cargo Tank Internal · Initial Certification · Ballast Water Examination · MTSA Verification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2289373
1 June 2005 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2375915
5 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784365
29 July 1996 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1088573
26 June 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1400383
26 July 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 886138
9 June 1995 COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1184142
5 June 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 875600
15 May 1995 Permit to Proceed
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463176
17 March 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177793
3 December 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 153459
20 October 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 870845
17 October 1994 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1177250
28 September 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1174702
23 September 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1171374
20 September 1994 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1180726
8 September 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1173428
30 August 1994 Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1180723
19 July 1994 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 864080
18 October 1993 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 840638
15 October 1993 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1331111
13 October 1993 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1141273
20 September 1993 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1150553
10 November 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961112
30 October 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1261897
27 October 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1264127
28 September 1992 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1417467
11 September 1992 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 950138
21 September 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1001943
21 September 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1353332
8 July 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 939636
7 June 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934160
3 June 1991 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1038994
3 June 1991 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1345304
18 August 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 913150
24 July 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 911590
11 July 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1223888
22 June 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1214833
18 June 1990 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1243485
20 February 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 926665
4 February 1990 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1286616
5 December 1989 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 905352
29 November 1989 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 901182
19 September 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900331
23 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893067
8 April 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1039046
14 March 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1203990
20 October 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1199329
20 October 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1204461
20 September 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1352416
26 August 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1039850
15 July 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032462
8 July 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 896025
8 June 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1199197
2 June 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1201970
26 May 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1197199
19 May 1988 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1198518
5 May 1988 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1201623
19 April 1988 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1042763
23 March 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293200
22 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327736
15 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322298
28 September 1987 Excursion Permit
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1009094
7 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332055
3 April 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004388
3 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008052
3 April 1987 Initial Certification
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326482

Deficiency record · 166

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 March 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a loss of propulsion was attributed to loss of pitch control on both shafts. 74SOLAS (2020) 1/11 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2026
Resolution: Received report of survey from ABS w/ finding number.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported its #4 SSDG is inoperable. 74 SOLAS (24) I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 October 2025
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 30 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported both anchor windlasses were inoperable. 74 SOLAS (24) I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 October 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 15 August 2025 Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seafarer serves, and the MMC, along with a valid medical certificate, must be presented to the Master of the vessel at the time of employment or before signing Articles of Agreement. Based on the mitigation plan provided by the master, the following actions will be implement to resolve the vessel’s manning deficiencies: •Cargo Mate missing STCW Advanced Oil Tanker Cargo Operations. Chief Mate will conduct next cargo load (14Aug2025). Cargo Mate will work under Chief Mate during loads until STCW endorsement is received. STCW application submitted to NMC. •Pumpman missing STCW Advanced/Basic Oil Tanker Cargo Operations. DEMACH will cover the Pumpman’s duties until endorsement is received or N12 sends a qualified replacement. IAW MSC manning scales, DEMACH can substitute Pumpman billet. STCW application submitted to NMC. •3AE missing all STCW endorsements. Member will remain on board so Redline is not crossed for Logistic UNREP Operations. STCW application submitted to NMC. •BOSN missing STCW Able Seafarer-Deck endorsement. CARGO BOSN can cover duties as Ship/Cargo BOSN. STCW application along with Able Seafarer assessments submitted to NMC. •Chief Engineer missing STCW Advanced Oil Tanker Cargo Operations. STCW application has NOT been submitted. Chief Engineer does not participate in any cargo transfers. Member will submit application to NMC. •1AE missing STCW Advanced Oil Tanker Cargo Operations. Off going 1AE will remain on board to get required loads and discharges for endorsement. Cargo operations scheduled for 15SEP2025. Member will submit application for endorsement once required cargo operations are completed. Submit MMC reference numbers by 15Nov2025 to verify crewmembers MMCs are properly endorsed to fill positions on board the vessel. Deficiency added 15Aug2025. See Deficiency No. 3 for further details. Cite: 46 CFR 15.401(d) Deficiency added 15Aug2025. See Deficiency No. 3 for further details.
Action required: 705 - Other - as specified
Due 15 November 2025
Resolved 11 September 2025
Resolution: Verified mariners credentials in MMLD.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 12 August 2025 Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seafarer serves, and the MMC, along with a valid medical certificate, must be presented to the Master of the vessel at the time of employment or before signing Articles of Agreement. The following endorsements, and one medical certificate waiver, were missing and identified during the vessel’s manning review: -Chief mate missing STCW Advanced Firefighting and Advanced Oil Tanker Cargo Operations endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(1) and (g)(1) -Chief engineer missing STCW Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(f)(2) and (g)(2) -1AE missing Tankerman PIC or Tankerman Engineer endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(2) -2/M (cargo mate) missing STCW Advanced Oil Tanker Operations endorsement. 46 CFR 15.860 (f)(3) and (g)(1) -Pumpman had Tankerman PIC endorsement with no STCW Basic or Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(g)(1) -3AE missing all STCW endorsements. 46 CFR 15.401(b) -BOSN missing STCW Able Seafarer-Deck endorsement. 46CFR 15.404(b) -BM missing medical certificate waiver. 46 CFR 10.303 Provide a proposed plan to address these manning issues prior to sailing. Cite: 46 CFR 15.401(d)
Action required: 705 - Other - as specified
Resolved 15 August 2025
Resolution: Master provided manning mitigation plan. Issued new CG-835. See Def. 3.1.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 August 2025 Resolved
Means for illuminating the lifeboats and their launching gear during preparation for and the process of launching, and also for illuminating the water into which the lifeboats are launched until the process of launched is completed. Emergency lights were extinguished in the following locations: port side 06 deck, 04 deck aft house, port side 01 deck by liferaft 10, stbd 01 deck pivot-light (also cable/gland at packing tube). Cite: SOLAS (81 amend) III/Reg 19(a)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1572.0. See Deficiencies Documents tab for ABS report.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 12 August 2025 Resolved
The [Radio/GMDSS] log must be kept in an orderly manner. The log may be kept electronically or in writing. The required information for the particular class or category of station must be readily available. Key letters or abbreviations may be used if their proper meaning or explanation is contained elsewhere in the same log. The GMDSS log entries were not specific to the equipment tested and the CFR cites provided did not reflect the appropriate tests. Cite: 47 CFR 80.409(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1573.0. See Deficiencies Documents tab for ABS report.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 August 2025 Resolved
Simple operating instructions with a block diagram, showing the change-over procedures for remote steering gear control systems and steering gear power units, permanently displayed on the navigating bridge and in the steering gear compartment. The block diagram was missing from the bridge. Cite: 33 CFR 164.35(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1574.0. See Deficiencies Documents tab for ABS report.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 12 August 2025 Resolved
Shipboard incinerators shall be operated only in accordance with the manufacturer’s operating manual. The incinerator door did not close properly which could prevent proper sealing to the combustion chamber during operation, including a potential fire and smoke hazard. Cite: MARPOL Annex VI/ Reg 16.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1575.0. See Deficiencies Documents tab for ABS report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 12 August 2025 Resolved
The Company should ensure that each ship is manned with qualified, certificated and medically fit seafarers in accordance with national and international requirements. During the USCG annual inspection on board the USNS JOSHUA HUMPHREYS, the following manning and medical certification issues were identified: -Chief mate missing STCW Advanced Firefighting and Advanced Oil Tanker Cargo Operations endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(1) and (h)(1) -C/E missing STCW Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(f)(2) and (h)(1) -1AE missing Tankerman PIC or Tankerman Engineer endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(2) -2/M (cargo mate) missing STCW Advanced Oil Tanker Operations endorsement. 46 CFR 15.860 (f)(3) and (h)(1) -Pumpman had Tankerman PIC endorsement with no STCW Basic or Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(h)(1) -3AE missing all STCW endorsements. 46 CFR 15.401(b) -BOSN missing STCW Able Seafarer-Deck endorsement. 46 CFR 15.404(b) -BM missing medical certificate waiver. 46 CFR 10.303 Conduct an internal audit of the manning and crewing procedures to ensure qualified, certificated and medically fit mariners are assigned to the vessel. Provide the internal audit results to the USCG for review. Due in 3 months (12Nov2025). Have this procedure verified at the next external audit. Cite: SOLAS (2020) IX/Reg 3.1, ISM Code Part A 6.2.1
Action required: 705 - Other - as specified
Due 12 November 2025
Resolved 3 November 2025
Resolution: MSC provided results of internal audit. Also, MSC's DOC audit captured the review of this deficiency. See DOC finding 305.0
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 12 August 2025 Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have a mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section. 04 drainage containments on the stbd side were missing mechanical drain plugs. Cite: 33 CFR 155.310(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 12 August 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2025 Resolved
All life-saving appliances… shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. The two bridge wing lifebuoys were taped with improper retro-reflective material. Cite: SOLAS (2020) III/ Reg 34, LSA Code 1.2.2.7
Action required: 10 - Deficiency Rectified
Resolved 12 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 January 2025 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. (b) Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Note 1 to paragraph (b):Normally, these tests are conducted annually. To be completed by 11MAY2025 vessel can not operated in PUMS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2025
Resolved 11 August 2025
Resolution: Reviewed records of PSTPs being completed over past year onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 May 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel reported #3 SSDG inoperative. Vessel only has 1 operable SSDG. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 April 2024 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within two minutes, an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control spaces, and machinery spaces of category A. Third party fire servicing report stated that the vessel's fire detection system was not tied into an alarm that would sound after two minutes of inattention and that a test of that alarm was not carried out. 74 SOLAS (81 Amend.) II-2/13.1.4, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 April 2024 Resolved
Smoke detectors shall be installed in all stairways, corridors, and escape routes within accommodation spaces. Vessel's stairways, corridors, and escape routes within accommodation spaces are equipped with heat detectors, not smoke detectors. 74 SOLAS (81 Amend.) II-2/13.2.2, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found the EOS sliding watertight door will not consistently close during power or hand operations, and at times will not close at all. 74 SOLAS (20) I/11(a), 60a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in these divisions. Found the halon vent closure 03-87-2, supply 06-92-4 actuator inoperable and its linkage disconnected. Found the halon vent closure 05-92-1, supply 06-92-1 stuck open. 74 SOLAS(20) II-2/14.2.1.1.1, 60a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 April 2024 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Found overspeed automation testing for both diesel generators was last conducted in 2021 as per documentation, and the crew was unable to perform at this time. 74 SOLAS (81 Amend) II-1/45.2, 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2024 Resolved
After any survey of the ship has been completed, no change shall be made in the items covered by the survey without the sanction of the administration. Several different models of heat detector are installed throughout the vessel in various spaces, including several that are rated for an ambient temperature of maximum 100 degrees F installed within the main machinery space. Third party fire servicing report only referenced one model of heat detector. 74 SOLAS (20) I/11(b), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2024 Resolved
The function of the detection system shall be periodically tested by means of equipment producing hot air at the appropriate temperature. Heat gun used to test heat detectors produced air at a temperature more than 1000 degrees F greater than the temperature for which the heat detectors were rated. 74 SOLAS (81) II-2/13.1.13, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 April 2024 Resolved
A minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter’s communication shall be carried on board. Those two-way radiotelephone apparatus shall be of an explosion proof type or intrinsically safe. Ships constructed before 01JUL14 shall comply not later than the first survey after 01JUL18. Fire parties were not equipped with radios. 74 SOLAS (20) II-2/10.10.4, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Limit switch on the #1 lifeboat winch is inoperable. 74 SOLAS (20) III/20.2, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Casing of the #13 liferaft is deteriorated. 74 SOLAS (20) III/20.2, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection and protection of openings and penetrations in these divisions. The rolling shutter door creating an A-0 boundary around the galley serving line failed to completely close and latch. 74 SOLAS (20) II-2/2.1.1.1, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 9 April 2024 Resolved
In all ships, general arrangement plans shall be permanently exhibited for the guidance of ship’s officers. Plans shall be kept up to date. Out-of-date fire control plan is posted near the galley. 74 SOLAS (81) II-2/20.1, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 April 2024 Resolved
Exposed hatchways on the freeboard deck on type ‘A’ ships shall be provided with efficient watertight covers. Escape hatch from pump room was not watertight and was difficult to operate. 66 ICLL (88 Protocol) 26.5, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found the port steering gear hydraulic oil level sight indicator empty. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found emergency lights not operating in the machinery space - EOS console, engine room lower-level starboard gauge panel, forward of the #4 diesel generator. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found both diesel generators jacket water nonmetallic flexible hoses on the front end of the engine chaffed through the outer hose layer in several locations on the hoses. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found 2JV speakers outboard #1 synchronous motor and lower-level machinery space near main engine console missing as designed/approved parts. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found several oil mist detectors on both main diesel engines hanging from their wires. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found an empty Scott air pack stowage rack on the bulkhead outside the sewage space. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Wasted handle on the rescue boat hook. Rectify prior to drydock credit. 74 SOLAS (20) III/20.2, 705a
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. D rings on the rescue boat davit appear to be wasted/deteriorated. Rectify prior to drydock credit. 74 SOLAS (20) III/20.2, 705a
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 April 2024 Resolved
21 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Attending MIs required vessel to re-do fire drill after unsatisfactory first attempt. 74 SOLAS (20) III/19.2.1, 10c
Action required: 10 - Deficiency Rectified
Resolved 2 April 2024
Resolution: Resolved to the satisfaction of the attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Junction box for shore power for the #3 lifeboat is dangling and the associated cables are unsupported. 74 SOLAS (81) II-2/40.1.3, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection and protection of openings and penetrations in these divisions. The following fire doors failed to latch when released: fire door leading to the vestibule near the #2/#4 lifeboats. 74 SOLAS (20) II-2/2.1.1.1, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection systems. Thermal detector located in the O5 deck lounge had a hole drilled into the casing. 74 SOLAS (20) II-2/2.1.1.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Cable gland to the rescue boat winch control is not watertight. 74 SOLAS (81) II-2/40.1.3, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Stanchion for embarkation lighting near the port life rafts is seized and unable to swing, preventing the proximal life raft from being manually deployed. 74 SOLAS (20) III/20.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. One immersion suit was found with torn seams, five immersion suits were improperly sized for the personnel to which they were assigned, five immersion suits that were unable to be zipped fully, and one immersion suit was found with a broken light. 74 SOLAS (20) III/20.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Stowage box on foscle was missing lifejacket and immersion as well as placarding, required per fire control plan. 74 SOLAS (20) III/20.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 November 2023 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in § 31.10–17 (a) and (b) and your Certificate of Inspection must be endorsed. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel missed annual inspection and COI is now invalid. Rectify prior to departure. 46 CFR 31.10-17(a), 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2024
Resolution: Completed Annual Inspection (see Act. No. 7888390)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 January 2023 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of opening and penetrations of these divisions. The "A Class" fire boundary deck of the bridge has opened and unsealed cable penetrations in way of GMDSS and above the gyro equipment room. SOLAS 74(2020 ED.) II-2/14.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: Accepted as Condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 January 2023 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of opening and penetrations of these divisions. The cargo control room,beneath the bridge, has fourteen (14)open, unsealed and/or compromised cable penetrations in adjacent bridge deck above and cargo room bulkheads. SOLAS 74 (2020 ED)II-2/14.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: Accepted as Condition of ACS.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 January 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Cable runs in the overhead and on the bulkheads inside cargo pump rooms where supported by plastic wire ties. Additionally, bundles of cable are being supported by using live transformers cables as the support brackets. SOLAS 74 (2020 ED)I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2023
Resolved 20 January 2023
Resolution: Accepted as Condition of ACS.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 29 November 2022 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners.Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. AB has expired national medical.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: vessel had addational crew on board to fill the position
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2022 Resolved
Life boats must be fully equipped as required by the code. Skates per lsa code ch IV 4.4.7.9 were missing on all 4 life boats.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 November 2022
Resolution: Vessel crew installed scates on all 4 life boats.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2022 Resolved
Fire doors in main verticle zone bulkheads, galley boundaries and stairway enclosures other than power operated doors and normally closed shall satisfy the following reruirements. Fire door 06-70-1 would not close properly and fire door 03-102-1 missing kick pannel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2022
Resolved 30 November 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2022 Resolved
Doors and door frames in "b" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that divisions, this being determined in accordance with the ftp code. Machine shop door on 25ft flat was damaged, bent, and missing lock assembly.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 November 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. open ended wires were present in the overhead above start air receivers from newly installed evaporators.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2022
Resolved 30 November 2022
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 16 June 2022 Resolved
74SOLAS(20) 1/11(a) The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While bunkering JP5 fuel, vessel's sustained a rupture in its fuel piping system spilling 150 gallons of JP5 on deck and into the water.
Action required: 703 - Prior to bunkering operations
Resolved 16 June 2022
Resolution: Received finding report from ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ships or persons on board. Vessel reported that it lost power to the stbd main engine. Repair vessel to the satisfaction of attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects wioll remain fit to proceed to sea without danger to the ship or persons on board. Vessel is leaking lube oil leak from both tubes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 31 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported 02 of 04 ship generators inoperable. Vessel must obtain a tug assist of at least 3,000 horsepower or two tugs of at least 2,000 horsepower for the inbound transit to berth until safely moored. Provide class report attesting to repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2022
Resolved 31 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 March 2021 Resolved
Ducts provided for ventilation of machinery spaces of category A shall be fitted with automatic fire dampers. Supply fire dampers 06-92-4 and 06-92-3 did not fully close. 74 SOLAS (81) II-2/16.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2021
Resolution: Received report from ABS.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 February 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The vessel experienced a fire on the motor control unit for emergency fire pump. Repair to the satisfaction of class.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 February 2021
Resolved 12 February 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 August 2020 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Vessel master reported temporary valves were installed in the deck foam fire extinguishing system for cargo zones 1 and 2.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 September 2018 Resolved
Emergency generator automatic hydraulic start system was unable to provide three consecutive starts. System pressure dropped from 3000psi to 100psi. Repair, provide tech rep report, and demonstrate proper operation of EDG hydraulic starts to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: It was found that the hydraulic accumulators , total 5, nitrogen charges were depleted from the required 1500 PSI to 300 PSI in each accumulator. The system was recharged and the vessel was able to demonstrate required starts, per class report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 September 2018 Resolved
Food rations for all persons onboard each lifeboat must be airtight and kept watertight. 276 units are required of 10,000kJs; 69 per unit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: Food Rations - The vessel purchased all new rations for each boat, 69 per boat. The rations were each examined and found satisfactory per class report.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 September 2018 Resolved
Ventilation dampers 06-92-4 and 06-92-3 were inoperable. Means shall be provided to close all openings which admit air or allow gas to escape from the machinery space. Repair and demonstrate to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: Machinery space Ventilation Fans - The vessel made the required repairs. The fans and dampers were operated and found Satisfactory, per class report.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 September 2018 Resolved
Floating orange smoke signals on bridge wings are not USCG approved. Replace with USCG approved floating orange smoke signals to the satisfaction of the attending ABS surveyor.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 September 2018 Resolved
Lifeboats #1 and #4 shall be evaluated/serviced to address the fiberglass hull and its seaworthiness. Crew personnel/passengers are restricted to no more than 68 persons. Servicing shall be by manufacture representative. Provide servicing information to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 September 2018 Resolved
The fire detection system was modified after professional certification and was no longer certified. System shall be recertified via professional servicing to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 September 2018 Resolved
Three port side and three starboard side cable penetrations in class A boundaries located between the EOS and the steering gear flat were observed in poor condition and altered without Class or USCG approval. Repair to the satisfaction of the attending ABS surveyor. No extensions will be granted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
Electrical › Electric Generation Source (service) › Generator
Issued 16 May 2018 Resolved
One of ship's two service diesel generators are OOC. Vessel may conduct berth shift from pier 8/ berth 1 to pier 10/ berth 5 at Naval Station Norfolk. Vessel is required to have two assist tugs with aggregate total horsepower 7,000 or 70 ton bollard pull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 24 May 2018
Resolution: Vessel did not inform the Coast Guard when the berth shift was completed. Vessel did contact Coast Guard for another berth shift, when contacted vessel was at pier 10/berth 5.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 23 January 2018 Resolved
Vessel did not have required markings on/or in the vicinity of all life-saving equipment. Install required symbols as required in accordance with vessels Safety Plan to the satisfaction of Class Society.
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 2 February 2018
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 23 January 2018 Resolved
Found most of the cargo hoses past due for the required annual hydrostatic test. Complete hydro test of the cargo hoses to the satisfaction of the Class Society.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2018
Resolved 2 February 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 23 January 2018 Resolved
The following fire protection systems shall be in good working order so as to ensure their required performance if fire occurs; structural fire protection, including fire resisting divisions, and protection of opening and penetrations in these divisions. There are two fire dampers in the supply ducting to the incinerator room, one is manual and the other is electrical, but not wired into any system. The exhaust damper is also manually operated. Instructions should be added to existing fire fire fighting procedures for this space to include manually operating these dampers before releasing the fire fighting agent.
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 2 February 2018
Engineering › Fuel Oil Service System › Hose
Issued 14 January 2017 Resolved
Starboard main engine had chaffed fuel line resulting in fuel spray in the engine room. Replace/repair fuel line and clean fuel from engine room. Repair to the satisfaction of the attending class surveyor.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: ABS attended and provided survey report attesting to proper repairs.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 27 January 2016 Resolved
#4 SSDG stopped while online without any alarms or warning.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 8 February 2016
Resolution: Received class report attesting to proper operations.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 22 December 2015 Resolved
Issue involved indicator plates on the fuel pumps, fuel rack and governor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2016
Resolution: Received class report attesting to repairs to starboard engine.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 2 September 2015 Resolved
Jacket water cooling pipe coupling to the Port Main Engine failed. Repair this jacket water cooling pipe to the satisfaction of Classification Society
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 October 2015
Resolved 18 September 2015
Resolution: 17 Sep 2015: Received, reviewd class report sent by class surveyor via email. Report indicated new parts were installed and tested good with no leaks. uploaded class report to activity #5232826
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 11 August 2015 Resolved
Port main Engine suffered complete loss of cooling water.
Action required: 705 - Other - as specified
Resolved 20 August 2015
Resolution: Repairs to port main engine were completed and ABS surveyor witnessed satisfactory operation of engine. CG-835 cleared.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 6 October 2014 Resolved
Emergency fire pump control panel is not operational. Emergency fire pump control panel must be repaired to the satisfaction of the attending class surveyor. While control panel is not working, a fully manned watch is required until repaired. If the status of the operational fire pumps changes, contact Activities Europe immediately.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2014
Resolution: Replaced faulty connectors and tested satisfactorily from all stations.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 August 2011 Resolved
Emergency Light over After Steering Emergency Steering Gear Consol is inoperative.
Condition: Improper/Lack of Maintenance
Due 5 September 2011
Resolved 7 August 2011
Resolution: Replaced light bulbs
Engineering › Bilge Water Management System › Piping
Issued 5 August 2011 Resolved
Bilge pump spool piece in way of discharge has a soft patch on it. Renew spool piece.
Condition: Improper/Lack of Maintenance
Due 5 September 2011
Resolved 7 August 2011
Resolution: Replaced spool piece.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 5 August 2011 Resolved
Both Local and Remote "Over Speed" indicator Lamps on # 4 Generator are inoperative.
Condition: Improper/Lack of Maintenance
Due 5 September 2011
Resolved 7 August 2011
Resolution: Replaced light bulbs.
Engineering › Bilge Water Management System › Pump
Issued 5 August 2011 Resolved
Starboard Bilge Pump remote shutdown is inoperative.
Condition: Improper/Lack of Maintenance
Due 5 September 2011
Resolved 7 August 2011
Resolution: Remote shutdowns were mislabeled. Labels have been replaced.
Engineering › Diesel Engine (propulsion-electric) › Injector (fuel injection)
Issued 25 October 2010 Resolved
Prior to departure, assess damages, make permanent repairs and test #4 SSDG. This can be cleared by Classification Society witnessing full operational test of the generator and all appropriate safety features including reverse power relay. Classification report attesting to the above can be sent to [email withheld] for consideration prior to the release of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2010
Resolved 29 October 2010
Resolution: [name withheld] received email from USNS [name withheld] and ABS Surveyor for UAE [name withheld] stating that the work had been completed and the SSDG safety functions tested satisfactorily.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 22 November 2005 Resolved
Prove proper operation of all sinks, toilets and showers throughout ship prior to activation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 27 June 2006
Communications › Alarms/Indicators › General Alarm
Issued 22 November 2005 Resolved
Prove proper operation of the following general alarm bells: lower level engine room outboard @ frame 80 port side, main deck fiddley space, flight deck fwd bulkhead starboard side, athwart ship starboard side prior to activation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 28 February 2006
Communications › Internal Communications System › Sound-powered Telephone
Issued 22 November 2005 Resolved
Prove proper operation of starboard and port bridge wing sound powered phones prior to activation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 28 February 2006
Fire Fighting › Fixed Deck Foam System › Valves
Issued 22 November 2005 Resolved
Prove proper operation of AFFF forward and aft station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 January 2006
Resolved 28 February 2006
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 22 November 2005 Resolved
Prove proper operation of cargo high level and overfill alarms for the following tanks: 3P, 3C, 3S, 2C, 1P, and 1S. Also, prove proper operation of all audible alarm/horn for the entire cargo control center console.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2006
Resolved 17 September 2010
Resolution: Contract for installation for deck overfill alarms has been awarded and will be completed by 2015.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 November 2005 Resolved
Prove proper operation of the OWS prior to activation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 28 February 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 22 November 2005 Resolved
Prove proper operation of both aux boilers and the automation of the same prior to activation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 January 2006
Resolved 28 February 2006
Communications › Visual Communication › Signalling Lamp
Issued 22 November 2005 Resolved
Add additional vital and non-vital engine alarms (audible and visual) to various locations around the engine space, primarily in the machine shop and around the aux boilers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 27 June 2006
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 22 November 2005 Resolved
Amend the vital system automation test procedures IAW the safety set point and procedural statements.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 September 2006
Resolved 3 October 2014
Resolution: Administratively cleared because no longer valid for this ACP enrolled vessel.
Lifesaving
Issued 9 June 1995 Resolved
MOTOR LIFE BOAT NO.1 MISSING SPRINKLER SYSTEM SPRAY DEFLECTOR ON FORWARD HATCH. MOTOR LIFE BOAT NO.3 NAV LIGHT PLASTIC SHIELD BROKEN.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Navigation
Issued 9 June 1995 Resolved
U.S. LIGHT LIST VOL 2 MISSING ONE CORRECTION.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Fire Fighting
Issued 9 June 1995 Resolved
OPERATION OF AUTOMATIC FIRE DAMPER 06-92-3.
Condition: Unknown
Due 9 June 1995
Resolved 9 June 1995
Deck/Cargo
Issued 9 June 1995 Resolved
PROVE TO THE SATISFACTION OF COGNIZANT [name withheld] THAT A HYDRO TEST OF ALL CARGO HOSES HAS BEEN SATISFACTORLY COMPLETED.
Condition: Unknown
Due 30 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 8 September 1994 Resolved
PERSONS ONBOARD VESSEL LIMITED TO 110 TOTAL UNTIL TWO ADDITIONAL 15 PERSON LIFERAFTS ARE PROVIDED ONBOARD.
Condition: Unknown
Due 30 September 1994
Resolved 12 September 1994
Engineering
Issued 30 August 1994 Resolved
REPLACE THE FOLLOWING FLAME SCREENS: AIR ESCAPE 3-60-1 AFO SETT TK VENT, AIR ESCAPE 3-62-1 AFO SETT TK VENT, VENT 1-88-2 (NO. NOT LEGIBLE), VENT 5- 88-2, AND #5P DFM TANK ULLAGE OPENING.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Construction/Loadline
Issued 30 August 1994 Resolved
REPAIR DOGS ON QAWTD 01-39-2.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Deck/Cargo
Issued 30 August 1994 Resolved
STATION #1 RETRIEVER WINCH HAS WASTED PV VALVE FITTING AND HOUSING PLATING WHICH REQUIRE REPLACEMENT.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
REPAIR/REPLACE AT LEAST TWO LIFE PRESERVERS (EIGHTEEN HAD PARTED SEAMS- SIXTEEN WERE OVER NUMBER REQUIRED BY USCG). VESSEL LIMITED TO 135 PERSONS UNTIL ITEM IS COMPLETE.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Fire Fighting
Issued 30 August 1994 Resolved
REPLACE FOUR MISSING PORTABLE FIRE EXTINGUISHERS ON THE FLIGHT DECK.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Deck/Cargo
Issued 30 August 1994 Resolved
CLEAN SLUDGE FROM STATION 9 (MAIN DECK FR 58 STBD) CONTAINMENT.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Deck/Cargo
Issued 30 August 1994 Resolved
REPAIR/REPLACE WASTED CONTAINMENT DRAIN PLUGS AND FITTINGS THROUGHOUT WEATHER DECKS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
LIFEBOATS 1,2 AND 4 PROPELLORS HITTING THEIR PROP GUARDS AND CUTTING INTO THE FIBERGLASS. ADJUST PROP GUARDS SO PROPS HAVE CLEARANCE TO TURN WITHOUT OBSTRUCTION.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Fire Fighting
Issued 30 August 1994 Resolved
REPLACE MISSING SPUD KEEPER CHAINS ON SEVERAL NAVY ALL PURPOSE NOZZLES.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Engineering
Issued 30 August 1994 Resolved
PROVE PROPER OPERATION OF OUTBOARD STARTING AIR FLASK RELIEF VALVE TO USCG MARINE INSPECTOR.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Fire Fighting
Issued 30 August 1994 Resolved
LOCATE OR PROVIDE AN INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Electrical
Issued 30 August 1994 Resolved
REPAIR INOPERATIVE BATTLE LANTERNS AND EMERGENCY LIGHTS: VESTIBULE 01-67-1,01 PORT PASSAGEWAY FR 69, NUMEROUS LIGHTS IN PUMP ROOMS, DECK DEPT OFFICE, CARGO CONTROL ROOM (OVER CONTROL CONSOLE).
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
REPLACE ALL SEA SICK PILLS, ASPIRIN AND EYE IRRIGANTS FOR ALL FOUR LIFEBOATS.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
REPLACE LIFE RING AND ITS BRACKET AT FR 40 PORT.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Lifesaving
Issued 30 August 1994 Resolved
AUTO RELEASE MECHANISM FOR 406 EPIRB IS OUT OF DATE (EXP NOV 93) AND MUST BE REPLACED.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Engineering
Issued 30 August 1994 Resolved
REMOVE PAINT FROM VENT LABEL PLATES.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Construction/Loadline
Issued 30 August 1994 Resolved
FREE FROZEN DOGS ON WEATHER DECK SUPPLY VENTS AND REPLACE TWO BROKEN DOGS ON SUPPLY VENT 01-19-2.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Fire Fighting
Issued 20 September 1993 Resolved
PROVE PROPER OPERATION OF THE AFT FOAM STATION PRIOR TO NEXT CARGO OPERATIONS, OR COMPLIANCE DATE, WHICHEVER COMES FIRST.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Deck/Cargo
Issued 20 September 1993 Resolved
PROVE PROPER OPERATION OF DISCHARGE MONITOR PRIOR TO NEXT CARGO OPERATION, OR COMPIANCE DATE, WHICHEVER COMES FIRST.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Deck/Cargo
Issued 20 September 1993 Resolved
CONDUCT HYDROSTATIC TEST OF ALL CARGO HOSES PRIOR TO NEXT CARGO OPERATIONS,OR COMPLIANCE DATE, WHICHEVER COMES FIRST.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Electrical
Issued 20 September 1993 Resolved
PROVE PROPER OPERATION OF THE PORT GENERATING/PROPULSION POWER TAKE OFF (PTO) UNIT.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Construction/Loadline
Issued 20 September 1993 Resolved
PROVE PROPER OPERATION OF THE BILGE MONITOR.
Condition: Unknown
Due 20 September 1993
Resolved 20 September 1993
Deck/Cargo
Issued 30 October 1992 Resolved
THE VESSEL IS NOT TO CARRY CARGO IN THE TEMPORARY MOGAS TANK UNTIL SUCH TIME AS THE INSTALLATION PLANS HAVE BEEN APPROVED, THE PIPING SYSTEM HYDRO TESTED, AND THE INSPECTION CERTIFICATE AMENDED ACCORDINGLY BY THE USCG._x001C_ _x001C_
Condition: Unknown
Due 30 October 1992
Resolved 30 October 1992
Engineering
Issued 11 September 1992 Resolved
UPDATE AUTOMATION TEST PROCEDURE TO REFLECT UPGRADES TO ENGINE ROOM AUTOMATION
Condition: Unknown
Due 11 November 1992
Resolved 28 October 1992
Fire Fighting
Issued 21 September 1991 Resolved
PROVIDE APPROVED PLANS FOR FIRE PUMP RECIRCULATING PIPING MODIFICATION FOR EACH FIRE PUMP.
Condition: Unknown
Due 21 September 1991
Resolved 21 September 1991
Deck/Cargo
Issued 3 June 1991 Resolved
RETAIN ALL CARGO SLOPS ON BOARD UNTIL SUCH TIME AS CARGO MONITOR IS REPAIRED AND PROPER OPERATION IS PROVEN IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Fire Fighting
Issued 3 June 1991 Resolved
CHANGE PLAQUARD FOR PUMP ROOM FIXED HALON SYSTEM TIME DELAY TO READ 34 SEC_x001C_VICE 40 SEC. REPLACE TIME DELAY WITH PROPER 40 SEC TIME DELAY AND TEST IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 3 June 1991
Resolved 3 June 1991
Electrical
Issued 18 June 1990 Resolved
REPLACE BURNED OUT LAMPS IN PAINT LOCKER
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Electrical
Issued 18 June 1990 Resolved
REPLACE BURNED OUT LAMPS IN PUMP ROOM.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Fire Fighting
Issued 18 June 1990 Resolved
PROVIDE HOSE AND SPANNER FOR AFT SPACE IN PUMP ROOM.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Fire Fighting
Issued 18 June 1990 Resolved
ATTACH MANUAL FIRE PULL BOX AT FOOT OF LADDER TO PUMP ROOM
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 18 June 1990 Resolved
HOSE TEST AND PROVE WATERTIGHT THE SOFT PATCH TO THE MAIN DECK FAN ROOM
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Deck/Cargo
Issued 18 June 1990 Resolved
PROVIDE AS NECESSARY PLUGS FOR ALL OIL CONTAINMENT BOXES ON WEATHER DECKS
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
PROVIDE PROPER SIZE BOATHOOKS AND CG APPROVED FISHING KITS FOR ALL LIFEBOATS
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Deck/Cargo
Issued 18 June 1990 Resolved
PROVIDE QA INSPECTION TICKETS FROM NORSHICO BERKLEY, NORFOLK, VA, WITH USCG INSPECTOR'S SIGNATURE VERIFYING RAS AND FAS RELIEF VALVES WERE TESTED OR TEST SAME VALVES.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Deck/Cargo
Issued 18 June 1990 Resolved
PROVIDE AFFIDAVIT OR LOG ENTRY FOR CARGO PIPING HYDRO
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
CLEAN POSTED STAINLESS STEEL LIFEBOAT INSTRUCTIONS AND MAKE LEGIBLE
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
OPERATE IN WATER AND PROVE SATISFACTORY AHEAD AND ASTERN PROPULSION FOR #2 AND #4 LIFEBOATS
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
PROVE PROPER OPERATION OF BOTH RESCUE BOATS IN WATER.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 18 June 1990 Resolved
PROVIDE GUARD FOR PUMP MOTOR SHAFT AT EACH WATERTIGHT DOOR (CLASS 3) LOCATION ON 40' FLAT (3 DOORS TOTAL).
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Electrical
Issued 18 June 1990 Resolved
DEMONSTRATE PROPER OPERATION OF THE EMERGENCY DIESEL GENERATOR'S HIGH COOLING JACKET WATER TEMP ALARM.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Engineering
Issued 18 June 1990 Resolved
CONDUCT AN INTERNAL INSPECTION OF PRESSURE VESSELS NUMBERED: 23441(WHISTLE)AND 234142 (HPAC).
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Engineering
Issued 18 June 1990 Resolved
PROVE PROPER OPERATION OF THE BILGE PUMP AND BILGE SYSTEM ALARMS.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Navigation
Issued 18 June 1990 Resolved
TEST THE STEERING GEAR EMERGENCY HAND PUMP STEERING
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Accommodation/Occupational Safety
Issued 18 June 1990 Resolved
PROBIDE SERVICING CERT FOR SHIPS ELEVATORS
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Fire Fighting
Issued 18 June 1990 Resolved
MOUNT INTERNATIONAL SHORE CONNECTIONS IN ACCORDANCE WITH SHIP'S FIRE CONTROL PLAN.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 18 June 1990 Resolved
PROVIDE PLACARD OR STENCIL DIRECTIONAL MARKINGS FOR MANUAL CRANK ARM AT EACH WATERTIGHT FOOR (CLASS 3) LOCDATION ON 40' FLAT (3 DOORS TOTAL)
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Accommodation/Occupational Safety
Issued 18 June 1990 Resolved
MAKE PROPER APPROVED REPAIRS/MODIFICATIONS TO INDICATED JUMPER DUCTS AS PERUSCG G-MVI-1/14 LETTER 16711/T-AO
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Fire Fighting
Issued 18 June 1990 Resolved
TEST AND PROBE FULLY OPERATIONSL THE VESSEL'S AFFF FOAM SYSTEM.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Fire Fighting
Issued 18 June 1990 Resolved
MAKE CORRECTIONS TO AFFF MANUAL TO REFLECT NEW COATING SYSTEM
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
STENCIL LIFERAFT STATIONS IN ACCORDANCE WITH 46 CFR 33.25-10
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
PROBE OPERATIONAL LIFEBOAT EMBARKATION LIGHTS
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Electrical
Issued 18 June 1990 Resolved
PROVE OPERATIONAL ALL EMERGENCY LIGHT FROM SHIP'S SERVICE POWER AND EMERGENCY POWER.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Engineering
Issued 18 June 1990 Resolved
REPLACE THE AFT SAFETY RELIEF VALVE ON THE FORWARD BOILER (21865) WITH AN ASME STAMPED SAFETY VALVE.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Electrical
Issued 4 February 1990 Resolved
MAKE PERMANENT REPAIRS TO THE #3 SHIPS SERVICE GENERATOR AND TEST SAME TO THE SATISFACTION OF AN ATTENDING CG MARINE INSPECTOR. REPAIRS SHALL BE COM-PLETED PRIOR TO DEPARTURE FROM NEXT PORT OF CALL, NORFOLK, VA. VESSEL SHALL NOT PERFORM UNREP OPS, UNLESS IT IS DETERMINED SAFE TO DO SO BY THE
Condition: Unknown
Due 4 February 1990
Resolved 4 February 1990
Fire Fighting
Issued 5 December 1989 Resolved
MAKE PERMANENT REPAIRS TO AFFF FOAM TANKS PER PROPOSAL APPROVED BY G-MVI-3. REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMIPRIOR TO 30 APR 90.
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Fire Fighting
Issued 29 November 1989 Resolved
PROVIDE SATISFACTORY PROPOSAL TO THE COGNIZANT OCMI TO ADDRESS THE CONTAM- INATION OF THE AFFF FOAM SYSTEM AND PERMANENT REPAIRS TO TWO FOAM HOLDING TANKS PRIOR TO THE VESSELS DEPARTURE FROM THE PORT OF HAMPTON ROADS. ALL REPAIRS ARE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 29 November 1989
Resolved 29 November 1989
Fire Fighting
Issued 19 September 1989 Resolved
HAVE PORTABLE FIRE FIGHTING EQUIPMENT SERVICED BY AN APPROVED FACILITY.
Condition: Unknown
Due 19 September 1989
Resolved 19 September 1989
Lifesaving
Issued 8 April 1989 Resolved
PROVIDE A DESCRIPTION OF THE PROBLEM, PHOTOGRAPHS AND A REPAIR PLAN TO THE [name withheld] FOR THE DELAMINATION OF THE GUNWALES IN LIFEBOATS 1,3 AND 4.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Lifesaving
Issued 8 April 1989 Resolved
MAKE PERMANENT REPAIRS TO THE NUMBER 4 LIFEBOAT IN WAY OF THE AFT PORT GUNWALE AND INTERIOR OF THE BOW.
Condition: Unknown
Due 8 April 1989
Resolved 8 April 1989
Deck/Cargo
Issued 8 June 1988 Resolved
PROVIDE AN APPROVED PLAN OF THE LUBE OIL CARGO TANK ADDITION TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Lifesaving
Issued 8 June 1988 Resolved
MAKE PERMANENT REPAIRS TO BOTH INFLATABLE BOAT BLADDERS TO THE SATISFACTIONOF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Documentation
Issued 8 June 1988 Resolved
PROVIDE NEW LIGHT SHIP CHARACTERISTICS AND MAKE NECESSARY CHANGES TO STABILITY PLAN FOR ADDITIONAL WEIGHTS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Deck/Cargo
Issued 8 June 1988 Resolved
MAKE PERMANENT REPAIRS TO AND TEST THE CARGO RESIDUE MONITOR TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 June 1988
Resolved 8 June 1988
Accommodation/Occupational Safety
Issued 2 June 1988 Resolved
MODIFY SHIP TO CORRECT THE PRESENT VENTILATION PIPING INSTALLATIONS THROUGHTHE AUXILLIARY FUEL TANKS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Deck/Cargo
Issued 19 April 1988 Resolved
PROVIDE AN APPROVED PLAN OF THE LUBE OIL CARGO TANK ADDITION TO THE SATIFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Deck/Cargo
Issued 19 April 1988 Resolved
MAKE PERMANENT REPAIRS TO AND TEST THE CARGO RESIDUE MONITOR TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Lifesaving
Issued 19 April 1988 Resolved
REMOVE SURPLUS UNSERVICEABLE RESCUE BOAT OR REPAIR TO THE SATISFACTION OF THE COGNIZANT OF THE OCMI.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Documentation
Issued 19 April 1988 Resolved
PROVIDE NEW LIGHT SHIP CHARACTERISTICS AND MAKE NECESSARY CHANGES TO STABILITY PLAN FOR ADDITIONAL WEIGHTS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 19 April 1988
Resolved 19 April 1988
Deck/Cargo
Issued 3 April 1987 Resolved
PROVIDE FOR EACH OF THE SEVEN RAM TENSIONER ACCUMULATERS A PRESSURE RELIEF DEVICE WHICH SHALL BE SET TO RELIEVE AT OR BELOW THE 2000PSI MAXIMUM ALLOW-ABLE WORKING PRESSURE OF THE ACCUMULATWRS. THE INSTALLATION SHALL BE IN ACCORDANCE WITH 46 CFR 54.15.
Condition: Unknown
Due 3 April 1987
Resolved 3 April 1987
Deck/Cargo
Issued 3 April 1987 Resolved
PROVIDE JOINT DETAILS FOR JP-5 CARGO PIPING SYSTEMS IN ACCORDANCE WITH 46 CFR 56.30-30(B) OR PROVIDE ALTERNATE DETAIL OFFERING EQUIVALENT FIRE RESISTENCE.
Condition: Unknown
Due 3 April 1987
Resolved 3 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.