USNS JOSHUA HUMPHREYS

USNS JOSHUA HUMPHREYS is a 1987 tank ship. The Coast Guard has recorded 62 inspections since 2016, most recently in March 2026, along with 72 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 13 March 2026.

Built
1987
Last inspected
13 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 March 2026
…with no type recorded12
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8302428
272044
Flag
UNITED STATES
Maury page id
psix-272044

Documentation record

Tonnage as PSIX records it25742 - Convention (Subpart B), Gross Ton
20706 - Regulatory (Subpart C or D), Gross Ton
8992 - Convention (Subpart B), Net Ton
18987 - Regulatory (Subpart C or D), Net Ton
27671 - Dead Weight, Ton
42383 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 62

13 March 2026 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8325749
12 March 2026 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8328480
29 October 2025 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8260537
27 October 2025 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8259114
13 October 2025 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 8254211
17 September 2025 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8236078
11 August 2025 Annual Inspection · ACP Annual Oversight
Physical examination · Activities Europe · Activity 8209627
9 June 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8157764
24 April 2025 Administrative Inspection
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8118355
12 February 2025 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8083637
10 February 2025 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8077499
28 May 2024 ACP COI Oversight · Re-Inspection · Deficiency Check · ACP Drydock Oversight · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7921603
15 May 2024 Permit to Proceed
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7912787
8 May 2024 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7908449
20 April 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7898591
2 April 2024 Annual Inspection · ACP Annual Oversight · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888390
2 April 2024 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7890596
14 February 2024 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7873795
4 January 2024 Damage Survey · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7845397
29 December 2023 Administrative Inspection · Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7843397
7 November 2023 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7821120
22 April 2023 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7673420
6 March 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7647459
6 January 2023 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7620179
29 November 2022 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 7657506
12 August 2022 Periodic Inspection · ACP Drydock Oversight · Administrative Inspection · ACP Periodic Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7531680
2 July 2022 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7493324
16 June 2022 Damage Survey · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7478983
4 June 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7468230
26 January 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7386499
16 August 2021 ACP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7307198
21 May 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7202765
31 March 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7165526
28 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7147632
11 February 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7139572
6 January 2021 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7120974
25 August 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7042496
24 July 2020 Administrative Inspection
Administrative · Activities Europe · Activity 7014778
3 February 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6901970
7 October 2019 Damage Survey · Administrative Inspection
Physical examination · Activities Europe · Activity 6830346
31 January 2019 Re-Inspection · Special · ACP Additional Oversight – Risk Assessment · ACP Drydock Oversight · Administrative Inspection · ACP COI Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6625802
23 October 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6566430
21 September 2018 ACP COI Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6521372
9 July 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6520984
16 May 2018 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6422277
3 May 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6430053
11 January 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6336037
14 January 2017 Examination of Repairs
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6072108
14 January 2017 Type not recorded
No type recorded · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6077248
7 November 2016 Administrative Inspection
Administrative · Activities Europe · Activity 6036480
13 October 2016 ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6022245
18 August 2016 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 5983597
18 July 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5953170
8 June 2016 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 5905643
18 May 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5880092
22 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5859939
12 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5852165
8 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5849753
6 April 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5848189
4 April 2016 Type not recorded
No type recorded · Activities Europe · Activity 5848955
27 January 2016 Administrative Inspection
Administrative · Activities Europe · Activity 5804149
11 January 2016 Type not recorded
No type recorded · Activities Europe · Activity 5800081

Deficiency record · 72

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 March 2026 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported a loss of propulsion was attributed to loss of pitch control on both shafts. 74SOLAS (2020) 1/11 (a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 March 2026
Resolution: Received report of survey from ABS w/ finding number.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported its #4 SSDG is inoperable. 74 SOLAS (24) I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 October 2025
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 30 October 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported both anchor windlasses were inoperable. 74 SOLAS (24) I/11(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 October 2025
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 15 August 2025 Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seafarer serves, and the MMC, along with a valid medical certificate, must be presented to the Master of the vessel at the time of employment or before signing Articles of Agreement. Based on the mitigation plan provided by the master, the following actions will be implement to resolve the vessel’s manning deficiencies: •Cargo Mate missing STCW Advanced Oil Tanker Cargo Operations. Chief Mate will conduct next cargo load (14Aug2025). Cargo Mate will work under Chief Mate during loads until STCW endorsement is received. STCW application submitted to NMC. •Pumpman missing STCW Advanced/Basic Oil Tanker Cargo Operations. DEMACH will cover the Pumpman’s duties until endorsement is received or N12 sends a qualified replacement. IAW MSC manning scales, DEMACH can substitute Pumpman billet. STCW application submitted to NMC. •3AE missing all STCW endorsements. Member will remain on board so Redline is not crossed for Logistic UNREP Operations. STCW application submitted to NMC. •BOSN missing STCW Able Seafarer-Deck endorsement. CARGO BOSN can cover duties as Ship/Cargo BOSN. STCW application along with Able Seafarer assessments submitted to NMC. •Chief Engineer missing STCW Advanced Oil Tanker Cargo Operations. STCW application has NOT been submitted. Chief Engineer does not participate in any cargo transfers. Member will submit application to NMC. •1AE missing STCW Advanced Oil Tanker Cargo Operations. Off going 1AE will remain on board to get required loads and discharges for endorsement. Cargo operations scheduled for 15SEP2025. Member will submit application for endorsement once required cargo operations are completed. Submit MMC reference numbers by 15Nov2025 to verify crewmembers MMCs are properly endorsed to fill positions on board the vessel. Deficiency added 15Aug2025. See Deficiency No. 3 for further details. Cite: 46 CFR 15.401(d) Deficiency added 15Aug2025. See Deficiency No. 3 for further details.
Action required: 705 - Other - as specified
Due 15 November 2025
Resolved 11 September 2025
Resolution: Verified mariners credentials in MMLD.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 12 August 2025 Resolved
Each individual referred to in paragraph (a) of this section must hold an MMC that serves as identification, with an appropriate endorsement for the position in which the seafarer serves, and the MMC, along with a valid medical certificate, must be presented to the Master of the vessel at the time of employment or before signing Articles of Agreement. The following endorsements, and one medical certificate waiver, were missing and identified during the vessel’s manning review: -Chief mate missing STCW Advanced Firefighting and Advanced Oil Tanker Cargo Operations endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(1) and (g)(1) -Chief engineer missing STCW Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(f)(2) and (g)(2) -1AE missing Tankerman PIC or Tankerman Engineer endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(2) -2/M (cargo mate) missing STCW Advanced Oil Tanker Operations endorsement. 46 CFR 15.860 (f)(3) and (g)(1) -Pumpman had Tankerman PIC endorsement with no STCW Basic or Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(g)(1) -3AE missing all STCW endorsements. 46 CFR 15.401(b) -BOSN missing STCW Able Seafarer-Deck endorsement. 46CFR 15.404(b) -BM missing medical certificate waiver. 46 CFR 10.303 Provide a proposed plan to address these manning issues prior to sailing. Cite: 46 CFR 15.401(d)
Action required: 705 - Other - as specified
Resolved 15 August 2025
Resolution: Master provided manning mitigation plan. Issued new CG-835. See Def. 3.1.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 August 2025 Resolved
Means for illuminating the lifeboats and their launching gear during preparation for and the process of launching, and also for illuminating the water into which the lifeboats are launched until the process of launched is completed. Emergency lights were extinguished in the following locations: port side 06 deck, 04 deck aft house, port side 01 deck by liferaft 10, stbd 01 deck pivot-light (also cable/gland at packing tube). Cite: SOLAS (81 amend) III/Reg 19(a)(ii)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1572.0. See Deficiencies Documents tab for ABS report.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 12 August 2025 Resolved
The [Radio/GMDSS] log must be kept in an orderly manner. The log may be kept electronically or in writing. The required information for the particular class or category of station must be readily available. Key letters or abbreviations may be used if their proper meaning or explanation is contained elsewhere in the same log. The GMDSS log entries were not specific to the equipment tested and the CFR cites provided did not reflect the appropriate tests. Cite: 47 CFR 80.409(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1573.0. See Deficiencies Documents tab for ABS report.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 12 August 2025 Resolved
Simple operating instructions with a block diagram, showing the change-over procedures for remote steering gear control systems and steering gear power units, permanently displayed on the navigating bridge and in the steering gear compartment. The block diagram was missing from the bridge. Cite: 33 CFR 164.35(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1574.0. See Deficiencies Documents tab for ABS report.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 12 August 2025 Resolved
Shipboard incinerators shall be operated only in accordance with the manufacturer’s operating manual. The incinerator door did not close properly which could prevent proper sealing to the combustion chamber during operation, including a potential fire and smoke hazard. Cite: MARPOL Annex VI/ Reg 16.6
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 18 August 2025
Resolution: Verified repairs by ABS. ABS Finding No. 1575.0. See Deficiencies Documents tab for ABS report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 12 August 2025 Resolved
The Company should ensure that each ship is manned with qualified, certificated and medically fit seafarers in accordance with national and international requirements. During the USCG annual inspection on board the USNS JOSHUA HUMPHREYS, the following manning and medical certification issues were identified: -Chief mate missing STCW Advanced Firefighting and Advanced Oil Tanker Cargo Operations endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(1) and (h)(1) -C/E missing STCW Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(f)(2) and (h)(1) -1AE missing Tankerman PIC or Tankerman Engineer endorsement (signed off vessel 12Aug2025). 46 CFR 15.860(f)(2) -2/M (cargo mate) missing STCW Advanced Oil Tanker Operations endorsement. 46 CFR 15.860 (f)(3) and (h)(1) -Pumpman had Tankerman PIC endorsement with no STCW Basic or Advanced Oil Tanker Cargo Operations endorsement. 46 CFR 15.860(h)(1) -3AE missing all STCW endorsements. 46 CFR 15.401(b) -BOSN missing STCW Able Seafarer-Deck endorsement. 46 CFR 15.404(b) -BM missing medical certificate waiver. 46 CFR 10.303 Conduct an internal audit of the manning and crewing procedures to ensure qualified, certificated and medically fit mariners are assigned to the vessel. Provide the internal audit results to the USCG for review. Due in 3 months (12Nov2025). Have this procedure verified at the next external audit. Cite: SOLAS (2020) IX/Reg 3.1, ISM Code Part A 6.2.1
Action required: 705 - Other - as specified
Due 12 November 2025
Resolved 3 November 2025
Resolution: MSC provided results of internal audit. Also, MSC's DOC audit captured the review of this deficiency. See DOC finding 305.0
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 12 August 2025 Resolved
A tank vessel with a capacity of 250 or more barrels that is carrying oil or hazardous material as cargo must have a mechanical means of closing each drain and scupper in the container or enclosed deck area required by this section. 04 drainage containments on the stbd side were missing mechanical drain plugs. Cite: 33 CFR 155.310(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 12 August 2025
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2025 Resolved
All life-saving appliances… shall be fitted with retro-reflective material where it will assist in detection and in accordance with the recommendations of the Organization. The two bridge wing lifebuoys were taped with improper retro-reflective material. Cite: SOLAS (2020) III/ Reg 34, LSA Code 1.2.2.7
Action required: 10 - Deficiency Rectified
Resolved 12 August 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 January 2025 Resolved
Periodic Safety tests must demonstrate the proper operation of the primary and alternate controls, alarms, power sources, transfer override arrangements, interlocks, and safety controls. Systems addressed must include fire detection and extinguishing, flooding safety, propulsion, maneuvering, electric power generation and distribution, and emergency internal communications. (b) Tests must be conducted at periodic intervals specified by the Coast Guard to confirm that vital systems and safety features continue to operate in a safe, reliable manner. Note 1 to paragraph (b):Normally, these tests are conducted annually. To be completed by 11MAY2025 vessel can not operated in PUMS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2025
Resolved 11 August 2025
Resolution: Reviewed records of PSTPs being completed over past year onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 May 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Vessel reported #3 SSDG inoperative. Vessel only has 1 operable SSDG. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 May 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 April 2024 Resolved
The activation of any detector or manually operated call point shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not received attention within two minutes, an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control spaces, and machinery spaces of category A. Third party fire servicing report stated that the vessel's fire detection system was not tied into an alarm that would sound after two minutes of inattention and that a test of that alarm was not carried out. 74 SOLAS (81 Amend.) II-2/13.1.4, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 April 2024 Resolved
Smoke detectors shall be installed in all stairways, corridors, and escape routes within accommodation spaces. Vessel's stairways, corridors, and escape routes within accommodation spaces are equipped with heat detectors, not smoke detectors. 74 SOLAS (81 Amend.) II-2/13.2.2, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2024
Resolved 19 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found the EOS sliding watertight door will not consistently close during power or hand operations, and at times will not close at all. 74 SOLAS (20) I/11(a), 60a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: protection of openings and penetrations in these divisions. Found the halon vent closure 03-87-2, supply 06-92-4 actuator inoperable and its linkage disconnected. Found the halon vent closure 05-92-1, supply 06-92-1 stuck open. 74 SOLAS(20) II-2/14.2.1.1.1, 60a
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 April 2024 Resolved
Measures shall be taken to the satisfaction of the Administration to ensure that the equipment is functioning in a reliable manner and that satisfactory arrangements are made for regular inspections and routine tests to ensure continuous reliable operation. Found overspeed automation testing for both diesel generators was last conducted in 2021 as per documentation, and the crew was unable to perform at this time. 74 SOLAS (81 Amend) II-1/45.2, 16a
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2024 Resolved
After any survey of the ship has been completed, no change shall be made in the items covered by the survey without the sanction of the administration. Several different models of heat detector are installed throughout the vessel in various spaces, including several that are rated for an ambient temperature of maximum 100 degrees F installed within the main machinery space. Third party fire servicing report only referenced one model of heat detector. 74 SOLAS (20) I/11(b), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2024 Resolved
The function of the detection system shall be periodically tested by means of equipment producing hot air at the appropriate temperature. Heat gun used to test heat detectors produced air at a temperature more than 1000 degrees F greater than the temperature for which the heat detectors were rated. 74 SOLAS (81) II-2/13.1.13, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 April 2024 Resolved
A minimum of two two-way portable radiotelephone apparatus for each fire party for fire-fighter’s communication shall be carried on board. Those two-way radiotelephone apparatus shall be of an explosion proof type or intrinsically safe. Ships constructed before 01JUL14 shall comply not later than the first survey after 01JUL18. Fire parties were not equipped with radios. 74 SOLAS (20) II-2/10.10.4, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Limit switch on the #1 lifeboat winch is inoperable. 74 SOLAS (20) III/20.2, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Casing of the #13 liferaft is deteriorated. 74 SOLAS (20) III/20.2, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection and protection of openings and penetrations in these divisions. The rolling shutter door creating an A-0 boundary around the galley serving line failed to completely close and latch. 74 SOLAS (20) II-2/2.1.1.1, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 9 April 2024 Resolved
In all ships, general arrangement plans shall be permanently exhibited for the guidance of ship’s officers. Plans shall be kept up to date. Out-of-date fire control plan is posted near the galley. 74 SOLAS (81) II-2/20.1, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 April 2024 Resolved
Exposed hatchways on the freeboard deck on type ‘A’ ships shall be provided with efficient watertight covers. Escape hatch from pump room was not watertight and was difficult to operate. 66 ICLL (88 Protocol) 26.5, 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found the port steering gear hydraulic oil level sight indicator empty. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found emergency lights not operating in the machinery space - EOS console, engine room lower-level starboard gauge panel, forward of the #4 diesel generator. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found both diesel generators jacket water nonmetallic flexible hoses on the front end of the engine chaffed through the outer hose layer in several locations on the hoses. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found 2JV speakers outboard #1 synchronous motor and lower-level machinery space near main engine console missing as designed/approved parts. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found several oil mist detectors on both main diesel engines hanging from their wires. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 9 April 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Found an empty Scott air pack stowage rack on the bulkhead outside the sewage space. 74 SOLAS (20) I/11(a), 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Wasted handle on the rescue boat hook. Rectify prior to drydock credit. 74 SOLAS (20) III/20.2, 705a
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 9 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. D rings on the rescue boat davit appear to be wasted/deteriorated. Rectify prior to drydock credit. 74 SOLAS (20) III/20.2, 705a
Action required: 705 - Other - as specified
Resolved 19 April 2024
Resolution: Accepted as a condition of ACS.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 2 April 2024 Resolved
21 Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Attending MIs required vessel to re-do fire drill after unsatisfactory first attempt. 74 SOLAS (20) III/19.2.1, 10c
Action required: 10 - Deficiency Rectified
Resolved 2 April 2024
Resolution: Resolved to the satisfaction of the attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Junction box for shore power for the #3 lifeboat is dangling and the associated cables are unsupported. 74 SOLAS (81) II-2/40.1.3, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 2 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection and protection of openings and penetrations in these divisions. The following fire doors failed to latch when released: fire door leading to the vestibule near the #2/#4 lifeboats. 74 SOLAS (20) II-2/2.1.1.1, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 April 2024 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection systems. Thermal detector located in the O5 deck lounge had a hole drilled into the casing. 74 SOLAS (20) II-2/2.1.1.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 April 2024 Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. Cable gland to the rescue boat winch control is not watertight. 74 SOLAS (81) II-2/40.1.3, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 2 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Stanchion for embarkation lighting near the port life rafts is seized and unable to swing, preventing the proximal life raft from being manually deployed. 74 SOLAS (20) III/20.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 2 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. One immersion suit was found with torn seams, five immersion suits were improperly sized for the personnel to which they were assigned, five immersion suits that were unable to be zipped fully, and one immersion suit was found with a broken light. 74 SOLAS (20) III/20.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2024 Resolved
All lifesaving appliances shall be in working order and ready for immediate use. Stowage box on foscle was missing lifejacket and immersion as well as placarding, required per fire control plan. 74 SOLAS (20) III/20.2, 10c
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
Resolution: Resolved to the satisfaction of the attending MI
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 November 2023 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual and periodic inspections within the periods specified in § 31.10–17 (a) and (b) and your Certificate of Inspection must be endorsed. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel missed annual inspection and COI is now invalid. Rectify prior to departure. 46 CFR 31.10-17(a), 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2024
Resolution: Completed Annual Inspection (see Act. No. 7888390)
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 January 2023 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of opening and penetrations of these divisions. The "A Class" fire boundary deck of the bridge has opened and unsealed cable penetrations in way of GMDSS and above the gyro equipment room. SOLAS 74(2020 ED.) II-2/14.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: Accepted as Condition of ACS.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 January 2023 Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resisting divisions, and protection of opening and penetrations of these divisions. The cargo control room,beneath the bridge, has fourteen (14)open, unsealed and/or compromised cable penetrations in adjacent bridge deck above and cargo room bulkheads. SOLAS 74 (2020 ED)II-2/14.1.1.1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 20 January 2023
Resolution: Accepted as Condition of ACS.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 January 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Cable runs in the overhead and on the bulkheads inside cargo pump rooms where supported by plastic wire ties. Additionally, bundles of cable are being supported by using live transformers cables as the support brackets. SOLAS 74 (2020 ED)I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2023
Resolved 20 January 2023
Resolution: Accepted as Condition of ACS.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 29 November 2022 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners.Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. AB has expired national medical.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: vessel had addational crew on board to fill the position
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 29 November 2022 Resolved
Life boats must be fully equipped as required by the code. Skates per lsa code ch IV 4.4.7.9 were missing on all 4 life boats.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 November 2022
Resolution: Vessel crew installed scates on all 4 life boats.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2022 Resolved
Fire doors in main verticle zone bulkheads, galley boundaries and stairway enclosures other than power operated doors and normally closed shall satisfy the following reruirements. Fire door 06-70-1 would not close properly and fire door 03-102-1 missing kick pannel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2022
Resolved 30 November 2022
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 29 November 2022 Resolved
Doors and door frames in "b" class divisions and means of securing them shall provide a method of closure which shall have resistance to fire equivalent to that divisions, this being determined in accordance with the ftp code. Machine shop door on 25ft flat was damaged, bent, and missing lock assembly.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 November 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 November 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in a normal manner. open ended wires were present in the overhead above start air receivers from newly installed evaporators.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 December 2022
Resolved 30 November 2022
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 16 June 2022 Resolved
74SOLAS(20) 1/11(a) The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While bunkering JP5 fuel, vessel's sustained a rupture in its fuel piping system spilling 150 gallons of JP5 on deck and into the water.
Action required: 703 - Prior to bunkering operations
Resolved 16 June 2022
Resolution: Received finding report from ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2022 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ships or persons on board. Vessel reported that it lost power to the stbd main engine. Repair vessel to the satisfaction of attending Class Surveyor.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects wioll remain fit to proceed to sea without danger to the ship or persons on board. Vessel is leaking lube oil leak from both tubes.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 February 2022
Resolved 31 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 27 January 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel reported 02 of 04 ship generators inoperable. Vessel must obtain a tug assist of at least 3,000 horsepower or two tugs of at least 2,000 horsepower for the inbound transit to berth until safely moored. Provide class report attesting to repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2022
Resolved 31 January 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 31 March 2021 Resolved
Ducts provided for ventilation of machinery spaces of category A shall be fitted with automatic fire dampers. Supply fire dampers 06-92-4 and 06-92-3 did not fully close. 74 SOLAS (81) II-2/16.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2021
Resolution: Received report from ABS.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 February 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The vessel experienced a fire on the motor control unit for emergency fire pump. Repair to the satisfaction of class.
Action required: 60 - Rectify deficiencies prior to movement
Due 25 February 2021
Resolved 12 February 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 August 2020 Resolved
No change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. Vessel master reported temporary valves were installed in the deck foam fire extinguishing system for cargo zones 1 and 2.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 September 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 September 2018 Resolved
Emergency generator automatic hydraulic start system was unable to provide three consecutive starts. System pressure dropped from 3000psi to 100psi. Repair, provide tech rep report, and demonstrate proper operation of EDG hydraulic starts to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: It was found that the hydraulic accumulators , total 5, nitrogen charges were depleted from the required 1500 PSI to 300 PSI in each accumulator. The system was recharged and the vessel was able to demonstrate required starts, per class report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 21 September 2018 Resolved
Food rations for all persons onboard each lifeboat must be airtight and kept watertight. 276 units are required of 10,000kJs; 69 per unit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: Food Rations - The vessel purchased all new rations for each boat, 69 per boat. The rations were each examined and found satisfactory per class report.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 September 2018 Resolved
Ventilation dampers 06-92-4 and 06-92-3 were inoperable. Means shall be provided to close all openings which admit air or allow gas to escape from the machinery space. Repair and demonstrate to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2018
Resolution: Machinery space Ventilation Fans - The vessel made the required repairs. The fans and dampers were operated and found Satisfactory, per class report.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 September 2018 Resolved
Floating orange smoke signals on bridge wings are not USCG approved. Replace with USCG approved floating orange smoke signals to the satisfaction of the attending ABS surveyor.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 21 September 2018 Resolved
Lifeboats #1 and #4 shall be evaluated/serviced to address the fiberglass hull and its seaworthiness. Crew personnel/passengers are restricted to no more than 68 persons. Servicing shall be by manufacture representative. Provide servicing information to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 September 2018 Resolved
The fire detection system was modified after professional certification and was no longer certified. System shall be recertified via professional servicing to the satisfaction of the attending ABS surveyor.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 21 September 2018 Resolved
Three port side and three starboard side cable penetrations in class A boundaries located between the EOS and the steering gear flat were observed in poor condition and altered without Class or USCG approval. Repair to the satisfaction of the attending ABS surveyor. No extensions will be granted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 October 2018
Resolution: ABS surveyor attested to rectification. Safenet Report Number NN3561870.
Electrical › Electric Generation Source (service) › Generator
Issued 16 May 2018 Resolved
One of ship's two service diesel generators are OOC. Vessel may conduct berth shift from pier 8/ berth 1 to pier 10/ berth 5 at Naval Station Norfolk. Vessel is required to have two assist tugs with aggregate total horsepower 7,000 or 70 ton bollard pull.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 May 2018
Resolved 24 May 2018
Resolution: Vessel did not inform the Coast Guard when the berth shift was completed. Vessel did contact Coast Guard for another berth shift, when contacted vessel was at pier 10/berth 5.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 23 January 2018 Resolved
Vessel did not have required markings on/or in the vicinity of all life-saving equipment. Install required symbols as required in accordance with vessels Safety Plan to the satisfaction of Class Society.
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 2 February 2018
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 23 January 2018 Resolved
Found most of the cargo hoses past due for the required annual hydrostatic test. Complete hydro test of the cargo hoses to the satisfaction of the Class Society.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 January 2018
Resolved 2 February 2018
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 23 January 2018 Resolved
The following fire protection systems shall be in good working order so as to ensure their required performance if fire occurs; structural fire protection, including fire resisting divisions, and protection of opening and penetrations in these divisions. There are two fire dampers in the supply ducting to the incinerator room, one is manual and the other is electrical, but not wired into any system. The exhaust damper is also manually operated. Instructions should be added to existing fire fire fighting procedures for this space to include manually operating these dampers before releasing the fire fighting agent.
Action required: 705 - Other - as specified
Due 5 February 2018
Resolved 2 February 2018
Engineering › Fuel Oil Service System › Hose
Issued 14 January 2017 Resolved
Starboard main engine had chaffed fuel line resulting in fuel spray in the engine room. Replace/repair fuel line and clean fuel from engine room. Repair to the satisfaction of the attending class surveyor.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 25 January 2017
Resolution: ABS attended and provided survey report attesting to proper repairs.
Engineering › Generator (propulsion/auxiliary-electric) › Circuit Breaker (overload/over current protection)
Issued 27 January 2016 Resolved
#4 SSDG stopped while online without any alarms or warning.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 February 2016
Resolved 8 February 2016
Resolution: Received class report attesting to proper operations.

Ownership record