Records from 2016 to 2026. Most recent: inspection, 18 August 2026.
Inspection history · 50
18 August 2026
Administrative Inspection
Administrative · Activities Europe · Activity 8467053
29 July 2026
Type not recorded
No type recorded · Activities Europe · Activity 8451153
23 March 2026
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 8330313
10 March 2026
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8323702
10 March 2026
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8324204
3 March 2026
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8319988
11 April 2025
ACP Drydock Oversight · Examination of Repairs · Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8110152
15 January 2025
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8064209
15 January 2025
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8100487
19 September 2024
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8006624
6 May 2024
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 8021009
17 April 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7896768
1 April 2024
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7888127
2 January 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7853326
11 September 2023
ACP Drydock Oversight · ACP Annual Oversight · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7834131
11 April 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7428506
5 March 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7476476
13 December 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7367461
9 September 2021
Administrative Inspection
Administrative · Activities Europe · Activity 7308975
9 September 2021
Type not recorded
No type recorded · Activities Europe · Activity 7336159
5 July 2021
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7246047
21 April 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7180645
29 October 2020
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7086630
29 October 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7090436
7 September 2020
Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7052705
11 August 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7054484
4 August 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7025456
3 August 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7042374
18 March 2020
Examination of Repairs · Administrative Inspection · ACP Drydock Oversight · Periodic Inspection · ACP Periodic Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6928393
8 March 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6936659
15 August 2019
Administrative Inspection · Examination of Repairs · Annual Inspection · Deficiency Check · Construction Oversight · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6856308
3 July 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6734942
13 March 2019
Administrative Inspection
Administrative · Activities Europe · Activity 6641844
9 January 2019
Type not recorded
No type recorded · Activities Europe · Activity 6609812
2 January 2019
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6604949
28 December 2018
Administrative Inspection
Administrative · Activities Europe · Activity 6603589
8 December 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6593975
27 November 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6587584
27 November 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6588398
23 November 2018
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6585578
23 November 2018
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6588414
18 September 2018
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6547957
18 June 2018
Examination of Repairs · Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6448038
17 November 2017
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6308741
25 April 2017
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6134062
5 April 2017
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6122329
23 September 2016
Annual Inspection · ACP Annual Oversight
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5996378
4 June 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5897026
24 February 2016
Administrative Inspection
Administrative · Activities Europe · Activity 5820694
16 February 2016
Deficiency Check
Physical examination · Activities Europe · Activity 5815474
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 January 2025
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. Vessel reported it loss STBD Main Engine while attempting to get underway.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 January 2025
Resolution: See ABS Report #6807759 uploaded into this activity.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-restriction divisions, and protections of openings and penetrations in this divisions. Multiple SFP A Class cable penetrations in overhead and bulkhead of cargo control room are compromised with gaps and mix matched fire-resistant material within the same penetration.
74 SOLAS (20) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-restriction divisions, and protections of openings and penetrations in this divisions. Multiple SFP B Class fire doors are missing hardware (lock and handles) leaving open holes in doors. Some stairtower doors had kick-out panels that would not properly secure in the closed position.
74 SOLAS (2020) II-2/14.2.1.1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 September 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. Fire alarm pull box, located in the Main Space Halon cylinder storage room, not properly secured to mounting bracket.
74 SOLAS (2020) II-2/14.2.1.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 September 2024
Resolved
Emergency source of power available shall be sufficient to supply those services necessary for safety of all on board in an emergency. Special consideration shall be giving to emergency lighting at each boat station. Embarkation lighting for starboard rescue boat did not operate.
74 SOLAS (Unamended) II-1/26.a.ii.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2024
Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in event of electrical fault in such areas, precaution against such shall be taken. Dead-end wire found in cable run, on tank top, in way of Center 7 cargo tank.
74 SOLAS (81 Amended) II-1/45.5.4
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 September 2024
Resolved
Fire protection systems, fire fighting systems and appliances shall be properly tested and inspected. Vessel could not provide the servicing report as proof
of fire fighting systems servicing.
74 SOLAS (2020) II-2/14.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 September 2024
Resolved
After any survey of the ship has been completed, no change shall be made in the items covered by the survey, without the sanction of the Administration. Port side steering gear compartment Class 3 WTD cannot be manually opened from either side of the door, and the manual pump on the forward side of the door is leaking hydraulic fluid.
74 SOLAS (2020) I/11(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 20 September 2024
Resolved
After any survey of the ship has been completed, no change shall be made in the items covered by the survey, without the sanction of the Administration. EOS Class 3 WTD cannot be manually opened from either side of the door, and the direction of door movement for manual operation isn’t clearly indicated.
74 SOLAS (2020) I/11(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 September 2024
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. The following portable fire extinguishers are not properly stowed in their brackets; port side aft steering gear room, 01 deck engineer shop on the work bench, port side 01 deck tunnel, and outside main deck office.
74 SOLAS (2020) II-2/14.2.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 20 September 2024
Resolved
The emergency switchboard shall be so arranged as to give easy access as may be needed to apparatus and equipment without danger to personnel. There is over 8 5 gallon buckets of engine coolant, over 5 gallons of oil, and several boxes of parts all improperly stowed behind the EDG switchboard.
74 SOLAS (81 Amended) II-1/45.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2024
Resolved
Electrical installations shall be such that the safety of crew and ship from electrical hazards will be ensured. There is a 120V ground indicated on the EDG switchboard.
74 SOLAS (81 Amended) II-1/40.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 September 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. The fire alarm pull box on the starboard side 01 deck tunnel is broken and held in place with duct tape.
74 SOLAS (2020) II-2/14.2.1.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 September 2024
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems. The fixed fire detector hanging from its wires in the engine room parts storage room starboard side.
74 SOLAS (2020) II-2/14.2.1.1.2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2024
Resolved
The machinery, associated piping systems, and fittings shall be of a design and construction adequate for the service for which they are intended and shall be installed and protected as to reduce to a minimum and danger to persons onboard, and other hazards. Hydraulic oil pipe fittings, and gauge line fittings are leaking on both steering gear power units.
74 SOLAS (81 Amended) II-1/26.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 20 September 2024
Resolved
In the event of a power failure to any one of the steering gear power units, an audible and visual alarmed shall be given on the navigating bridge. The installed power failure alarms for port and stbd steering hydraulic power units did not operate.
74 SOLAS (81 Amended) II-1/29.5.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2024
Resolved 24 September 2024
Resolution: Accepted by ABS.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 September 2024
Resolved
Electrical or other equipment which may constitute a source of ignition of flammable vapors shall not be permitted in these compartments. Paint locker had electric extension cord leading inside of paint locker powering a portable fan not designed for Class I Div I atmosphere.
74 SOLAS (81 Amended) II-1/45.9.2
Action required: 10 - Deficiency Rectified
Resolved 20 September 2024
Resolution: Remove non-intrinsically safe electrical equipment from the paint locker.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 September 2024
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Quick release bridge ring buoy was not connected to the smoke buoy with the minimum length of line required for deployment per the manufacture’s installation instructions. Line to short to gain the momentum detach smoke buoy from bracket.
74 SOLAS (2020) III/20.2
Action required: 10 - Deficiency Rectified
Resolved 20 September 2024
Resolution: Attached 12 ft line to smoke buoy from lifering per manufacturer's installation instructions.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 April 2022
Resolved
Test procedure documents must be a step-by-step or check-off list format. PSTP 8.8 automation test procedures don't reflect the OEM recommended test method and was deemed too high risk by vessel's crew to conduct. 8.7 not completed IAW PTSPs.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 16 August 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 April 2022
Resolved
Class 3 door must be designed, constructed, tested and marked in accordance with ASTM F1196. Door 2-131-1 Class 3 WTD does not fully close/seal manual closure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2022
Resolved 16 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 April 2022
Resolved
Inspections shall insure that the equipment and associated structure are in satisfactory operating conditions and fit for service for which they are intended. Hydraulic leak located in way of port aft CPP hydraulic pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 August 2022
Resolved 16 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 December 2021
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Oil mist monitoring system for both MDE's is not operational.
74 SOLAS (20) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 15 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2021
Resolved
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction
of the Administration.
Vessel suffered main steering gear casualty. Provide report from class stating steering gear has been fixed and vessel is safe to proceed to sea.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2021
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 24 February 2016
Resolved
Vessels host computer recording all engineering alarms is non fuctional.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 April 2016
Resolved 25 February 2016
Resolution: Received, reviewed and accepted class report stating full repair and function test of the affected system.
Engineering › Generator (propulsion-electric) › Circuit Breaker (overload/over current protection)
Issued 16 February 2016
Resolved
Vessel experienced a momentary loss of power and propulsion during routine underway transit. Both port and starboard Main Engines were online providing propulsion with #1 & #2 Power Take-Off (PTO) shaft generator units online providing ship's power. #2 PTO tripped offline due to a faulty SCL527 circuit card NIIN 01-293-7299
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 26 February 2016
Resolution: Received and accepted class report. Proper repair is completed. See attached report in document section.