Inspection history · 15
1 June 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8356688
5 May 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8129135
1 April 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8103604
10 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7930154
19 April 2023
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7672520
3 April 2023
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7662732
27 May 2021
Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7202946
8 July 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6952194
2 May 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6675980
18 April 2019
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6664700
17 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6394035
31 July 2017
Spot Check · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6226586
23 May 2017
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6154442
18 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6129211
18 April 2016
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5857582
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 June 2026
Resolved
RLB grab line is deteriorated. Replace grab line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 2 June 2026
Resolution: Grab line has been renewed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2026
Resolved
Vessel required 3 fire buckets onboard. Missing a bucket. Replace and stencil fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 2 June 2026
Resolution: 3 Fire buckets onboard and labelled properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2025
Resolved
IAW 46 CFR 185.520 each vessel operator/Master shall conduct man overboard and fire drills, as applicable. Provide verbal confirmation to USCG that all seasonal vessel operators/Masters have conducted satisfactory drills prior to operating season.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2025
Resolution: Received photographic evidence of compliance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 May 2025
Resolved
Provide proof of compliance with federal drug testing requirements for all registered vessel operators/Masters, IAW standards of 46CFR16. Operators/Masters not currently enrolled in DOT accepted testing program may not operate under the authority of their credential.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2025
Resolution: Received photgraphic evidence of compliance.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 May 2025
No resolution recorded
Remove abandoned, electric bilge pump from shaft alley,
or rewire so as to be serviceable. As removal of pump requires shaft to be pulled, next drydock inspection is satisfactory.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 June 2024
Resolved
Pre-engineered fire suppression system must automatically shut down (an engine) that draws intake air from within the protected space. Controls must shut down engine upon discharge of agent and have an operable override for engine restart post-discharge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2024
Resolution: Witnessed sat engine shutdown and override
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2024
Resolved
Main propulsion engine required two means of shutdown. Helm shutdown is not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2024
Resolution: Witnessed sat engine shutdown from helm station
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2024
Resolved
Gauge which indicates engine rpm must be provided and readily visible at the operating station. Existing gauge not functioning properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 July 2024
Resolution: Witnessed sat operation of helm station RPM gauge
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 April 2023
Resolved
Engine shutdown/override required, compatible with existing pre-engineered fire extinguishing system.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2023
Resolution: witnessed proper operation of fire suppression system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2023
Resolved
Provide second means of engine shutdown.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2023
Resolution: witnessed proper operation of engine shutdown from helm station
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2023
Resolved
Provide reflective tape for ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 July 2023
Resolution: ring buoy marked with required reflective tape
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 27 May 2021
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of all employed launch operators. Provide evidence of a random testing program for all launch operators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2021
Resolution: Adequate documentation provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 July 2020
Resolved
Provide evidence of required servicing of fixed-gas fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2020
Resolution: Satisfactory servicing records provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 July 2020
Resolved
Replace first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 24 July 2020
Resolution: New first aid kit provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 July 2020
Resolved
Flexible hose between raw water pump and engine must have two clamps at each end. Currently zero clamps holding hose on.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2020
Resolution: New hose clamps installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 July 2020
Resolved
Provide licensed mariner in accordance with vessel COI.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 July 2020
Resolution: Credential of properly licensed operator provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 July 2020
Resolved
Mark life jackets with vessel name. (01) child size life jacket has improper marking.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Resolved 8 July 2020
Resolution: Marking added.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 July 2020
Resolved
Provide evidence of required quarterly abandon ship / man overboard / fire fighting drills & training.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2020
Resolved 24 July 2020
Resolution: Drill logs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 May 2019
Resolved
Each RLB on a vessel must be approved IAW Sub Q, must have grab lines. Current lines are frayed and need to be replaced, or provide new RLB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 4 May 2019
Resolution: Purchased new RLB
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2019
Resolved
A vessel not req'd to have a power driven fire pump must have at least 3 - 2.5 gallon buckets w/attached lanyard and labeled "fire bucket". Vessel needs 3 - 2.5 gallon buckets, labeled, w/lanyard. Vessel has 5 gallon buckets, and opted to purchase 2.5 gallon buckets rather than drill holes in the other.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 8 July 2020
Resolution: Fire buckets all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2019
Resolved
Each vessel must be equipped with portable lights. Per SLIS yacht launch policy letter, provide one light at the operating station. Current light is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 4 May 2019
Resolution: operable portable light provided
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 May 2019
Resolved
Each floating waterlight on a vessel carrying one RLB must be attached w/a corrosion resistant clip. Install clip on waterlight lanyard attached to the RLB.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 2 May 2019
Resolution: corrected on the spot with new clip
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 2 May 2019
Resolved
Each RLB with a floating waterlight muct have a lanyard at least 3'-6' in length attaching the light to the RLB. Current lanyard is frayed and needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 2 May 2019
Resolution: corrected on the spot
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 April 2018
Resolved
Replace battery in float light.
Due 17 May 2018
Resolved 7 June 2018
Resolution: battery installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 31 July 2017
Resolved
There was no manual pull attached to fire bottle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2017
Resolved 4 August 2017
Resolution: Pull handle pin installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 31 July 2017
Resolved
Install safety tab on pull handle.
Due 31 July 2017
Resolved 4 August 2017
Resolution: Safety tab installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 April 2016
Resolved
Navigation lights were not functioning. Repair to proper operating condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 25 April 2016
Resolution: Lights repaired.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2016
Resolved
Line attaching waterlight to life ring was deteriorated. Repair with good line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 25 April 2016
Resolution: Line replaced.