ISLAND TIME

ISLAND TIME is a 2001 passenger vessel (inspected). The Coast Guard has recorded 37 inspections since 2001, most recently in December 2025, along with 60 deficiencies — 2 with no resolution recorded —.

Records from 2001 to 2025. Most recent: inspection, 4 December 2025.

Built
2001
Last inspected
4 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2430
Flag
UNITED STATES
367669650
Maury page id
psix-27243

Inspections, by type

…with no type recorded1
…past their stated due date1
Years with a record 22 calendar years (2001–2025)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.2 ft × 7.8 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWINNINGHOFF BOATS INC · ROWLEY, MA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWBURY, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 20 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6192MMSI 367669650 · active · compulsorily equipped · granted 26 September 2025, expires 26 September 2035
WDH9596MMSI 367669650 · expired · compulsorily equipped · granted 30 April 2015, cancelled 7 June 2025
WDD2430MMSI 367115210 · expired · compulsorily equipped · granted 17 May 2006, cancelled 23 July 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 37

4 December 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8277279
23 October 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8255529
4 April 2025 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8108702
20 November 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8034100
10 October 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8016806
24 October 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7809978
30 May 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7700234
28 November 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7597949
3 October 2022 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7570483
16 September 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7303306
8 June 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7219322
21 January 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7128978
24 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6984125
1 May 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6946861
13 September 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6811086
28 August 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6794732
29 November 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589074
11 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6436859
6 June 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6165978
22 November 2016 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6045896
1 August 2016 Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 5960998
23 May 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5885061
8 May 2014 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4857196
7 May 2012 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4305417
5 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4201776
6 April 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3447276
6 May 2008 Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3200180
21 March 2007 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2891952
2 May 2006 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2638402
3 May 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2348009
28 March 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2320947
25 May 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2077458
19 May 2003 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1796427
2 April 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1766874
3 June 2002 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1626770
1 August 2001 Plan Review "T" Boat
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1069076
2 July 2001 COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1397682

Deficiency record · 60

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 June 2026 No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. MI observed potential thinning out of the bottom plate in the lazarette bottom hull. Operator is to conduct 3rd party gauging of the bottom plate in the lazarette and provide plan to repair any wasted areas prior to credit hull inspection.
Action required: 705 - Other - as specified
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 December 2025 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel is not part of a consortium, and manages the drug and alcohol program on their own. Vessel needs to complete a full DAPI audit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2026
Resolution: Operator provided proof of DAPI enrollment and all documents required to comply with the requirements.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 December 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. MI observed pitting in the lazarette bottom hull and on the aft bulkhead in the tank room. MI is to conduct a full gauging to include any aluminum repairs prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2026
Resolution: MI gauged bottom plate and found pitting to be within acceptable limits.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 October 2025 Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. MI observed that all four floating water lights on board had expired, or the wrong type, battery installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator replaced all floating waterlights with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 October 2025 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. MI observed exposed form on one of the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator repaired the life floats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 October 2025 Resolved
A hatch exposed to the weather must be watertight. MI observed that the hatch going into the foc'sle had a gap in the gasket material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator replaced the gasket on the scuttle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2024 Resolved
A hatch cover must have securing devices. During the course of the inspection, a dog on the midships Freeman hatch to the lazarette broke off. Repair or replace hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Dog replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2024 No resolution recorded
[Life floats] with plastic foam buoyancy must have a plastic foam body with an external protective covering. The external protective covering for one of the life floats was worn and punctured in multiple locations. Repair covering or replace life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Two of the three floating electric waterlights attached to life floats were fraying and UV-damaged. Replace damaged lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Damaged lanyards were replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2024 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Trash cans on board were constructed of combustible materials. Replace trash cans with noncombustible equivalents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Plastic trash cans replaced with metal bins.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Child life jackets were stowed in the same compartment as adult jackets with no separation. Stow separately or create physical barrier between adult and child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Plexiglass barrier installed between adult and child PFDs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 October 2024 Resolved
Whenever damage or deterioration to structural members is discovered, the cognizant OCMI may require the vessel to effect permanent repairs. The hydraulic steering ram support bracket has a popped weld where it meets the tank room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2025
Resolution: MI inspected new weld. Sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 October 2022 Resolved
VESSEL MUST UNDERGO AN ANNUAL INSPECTION WITHIN THE 3 MONTHS BEFORE OR AFTER THE ANNIVERSARY DATE. VESSEL IS BEYOND THE 3 MONTH LIMIT AND THE COI IS NO LONGER VALID. SUBMIT AN APPLICATION FOR INSPECTION FORM CG-3752 AND COMPLETE A SATISFACTORY COI INSPECTION.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2022
Resolved 11 October 2022
Resolution: Performed satisfactory COI inspection and issued temp COI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 January 2021 Resolved
Batteries must be protected from falling objects. Neither of the two battery banks have a protective cover installed. Ensure that the batteries are protected from falling objects.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 4 February 2021
Resolution: Received photos of the newly installed box covers.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2020 Resolved
As appropriate for the intended voyage, a vessel must carry equate and up to date: Charts of large enough scale to make safe navigation possible; U.S Coast Pilot or similar publication; Coast Guard Light List; tide tables; and current tables. The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. The vessel did not have up to date Coast Pilots, Charts, and Navigation Rules. 46 CFR 183.420 33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: Missing publications were purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2020 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel only had one fire bucket. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: NEw fire buckets were purchased and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 June 2020 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Life jacket stowage containers did not say “life jackets.” 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: Stenciling was added to the life jacket stowage containers.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 June 2018 Resolved
Vessels pre engineered fire system does not shutdown A/C generator. Prove proper operation of fixed fire fighting system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Operationally tested pre engineered fire sytem and shutdown of M/Es and generator.
Engineering › Bilge Water Management System › Strainer
Issued 11 June 2018 Resolved
Renew bilge strainers in tank room and lazerett.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Verified installation of new bilge strainers.
Documentation › Certificates/Documents › Stability Letter
Issued 23 May 2016 Resolved
Stability letter missing. Provide copy of stability letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 24 May 2016
Resolution: Provided copy of stability letter to vessle owners.
Engineering › Steering Gear System › Fastener
Issued 23 May 2016 Resolved
Cotter pin missing on STBD rudder post. Install cotter pin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 23 May 2016
Resolution: New cotter Pin was installed.
Engineering › Bilge Water Management System › Piping
Issued 23 May 2016 Resolved
Missing check valves in bilge system. Install check valves in bilge system during next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Resolution: Check valves installed in bilge system at the manifold in the engine room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 May 2008 Resolved
Install guards on MDE fire and bilge pumps
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 June 2008
Resolved 10 June 2008
Resolution: Owner fabrticated and installed machinery guard
Communications › Alarms/Indicators › High Water Alarm
Issued 2 May 2006 Resolved
Replace high water alarm float for fwd compartment.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 20 March 2007
Resolution: High level alarm installed
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 2 May 2006 Resolved
Comply with EAP requirements of 46 CFR 16.401
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 20 March 2007
Resolution: Vessel currently enrolled in chemical testing program
Stability › Watertight Integrity › General
Issued 2 May 2006 Resolved
Double clamp hose by shaft penetration.
Action required: 705 - Other - as specified
Due 1 June 2006
Resolved 20 March 2007
Resolution: Hose is now double hose clamped
Deck/Cargo › Holds/Tanks › Hatch
Issued 3 May 2005 Resolved
Install lanyards on all weatherdeck hatches.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Installed lanyards.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 May 2005 Resolved
replace lanyard for waterlights on lifefloats.
Due 2 June 2005
Resolved 16 May 2005
Resolution: Replaced lanyards.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 25 May 2004 Resolved
Prior to carrying passengers Reinstall fixed fire fighting system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2004
Resolved 28 May 2004
Resolution: Installed fixed fire fighting system. Tested SAT.
Communications › Radio Communications › EPIRB
Issued 25 May 2004 Resolved
Provide new Hydro release for EPIRB.
Condition: Improper/Lack of Maintenance
Due 15 June 2004
Resolved 28 May 2004
Resolution: Installed new Hydro release.
Lifesaving › Rigid Liferafts
Issued 19 May 2003 Resolved
Prior to carrying passengers, provide suitably-sized weak links for life floats. LEGACY COMPONENT DESC: Weak Link
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2003
Resolved 3 June 2003
Resolution: [name withheld] examined and found satisfactory new weak link.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 19 May 2003 Resolved
Provide annual servicing for fixed and portable fire extinguishers. LEGACY COMPONENT DESC: Quantity of Gas
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 3 June 2003
Resolution: [name withheld] witnessed satisfactory servicing of all fixed and portable extinguishers.
Navigation › Piloting/Steering
Issued 3 June 2002 Resolved
Provide a current copy of the Coast Pilot and Light list. LEGACY COMPONENT DESC: Coast Guard Light List
Due 17 June 2002
Resolved 21 June 2002
Communications › Radio Communications
Issued 3 June 2002 Resolved
Provide Emergency Broadcast Placard.
Due 17 June 2002
Resolved 21 June 2002
Engineering › Bilge Water Management System
Issued 3 June 2002 Resolved
Double clamp the port side sea strainer hose in the engine compartment. LEGACY COMPONENT DESC: Hose
Due 17 June 2002
Resolved 21 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 3 June 2002 Resolved
Double clamp the port side exhaust hose in the lazzarette.
Due 17 June 2002
Resolved 21 June 2002
Engineering › Fuel Oil Service System
Issued 3 June 2002 Resolved
Properly label the emergency fuel shut off valve. LEGACY COMPONENT DESC: Valve
Due 17 June 2002
Resolved 21 June 2002
Engineering › Diesel Engine (auxiliary)
Issued 3 June 2002 Resolved
Properly reapir the generator to working order.
Due 17 June 2002
Resolved 21 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 3 June 2002 Resolved
Properly repair the fuel vent pipe with 30/30 mesh. LEGACY COMPONENT DESC: Vent Pipe
Due 17 June 2002
Resolved 21 June 2002
Lifesaving
Issued 3 June 2002 Resolved
Prove proper operation of the Life Float Light.
Due 17 June 2002
Resolved 21 June 2002
Lifesaving
Issued 2 July 2001 Resolved
Mark emergency exit "keep clear on both sides" NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Accommodation/Occupational Safety
Issued 2 July 2001 Resolved
Post emergency broadcast placard NLT 15JUL01.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Lifesaving
Issued 2 July 2001 Resolved
Mark upper deck for 7 persons Max. NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Navigation
Issued 2 July 2001 Resolved
Prior to carrying passengers place charts and U.S. Coast pilot onboard the vessel.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Accommodation/Occupational Safety
Issued 2 July 2001 Resolved
Post emergency instruction list NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Navigation
Issued 2 July 2001 Resolved
Install magnetic compass with light NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Navigation
Issued 2 July 2001 Resolved
Provide devation tables for magnetic compass NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Engineering
Issued 2 July 2001 Resolved
Install machinery Guards on both MDE's NLT 25JUL01.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 2 July 2001 Resolved
Install visual alarm for high level bilge alarm.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Accommodation/Occupational Safety
Issued 2 July 2001 Resolved
Install vent and pump out lines on sewage holding tank. NLT 15JUL01
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Electrical
Issued 2 July 2001 Resolved
Properly secure all electric cables NLT 15JUL01.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Construction/Loadline
Issued 2 July 2001 Resolved
Prior to carrying passengers install high water level alarm sensors in fueltank space and aft lazarette.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Lifesaving
Issued 2 July 2001 Resolved
Prior to carrying passengers prove proper registration of EPIRB.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Fire Fighting
Issued 2 July 2001 Resolved
Prior to carrying passengers properly mount portable fire extinguishers.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Lifesaving
Issued 2 July 2001 Resolved
Prior to carrying passengers properly install waterlight on lifefloat.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Construction/Loadline
Issued 2 July 2001 Resolved
Prior to carrying passengers properly rig portable bilge pump.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Lifesaving
Issued 2 July 2001 Resolved
Post lifejacket donning placard NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Fire Fighting
Issued 2 July 2001 Resolved
Provide 3-2.5 gallon buckets for firefighting NLT 15JUL01.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Electrical
Issued 2 July 2001 Resolved
Properly ground fuel fill lines NLT 15JUL01
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001
Engineering
Issued 2 July 2001 Resolved
Properly install fuel vent flame screens NLT 15JUL01.
Condition: Unknown
Due 31 July 2001
Resolved 31 July 2001

Ownership record