Records from 2016 to 2025. Most recent: inspection, 4 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 22
4 December 2025
Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8277279
23 October 2025
Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8255529
4 April 2025
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8108702
20 November 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8034100
10 October 2024
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8016806
24 October 2023
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7809978
30 May 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7700234
28 November 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7597949
3 October 2022
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7570483
16 September 2021
Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7303306
8 June 2021
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7219322
21 January 2021
Drydock Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7128978
24 June 2020
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6984125
1 May 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6946861
13 September 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6811086
28 August 2019
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6794732
29 November 2018
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589074
11 June 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6436859
6 June 2017
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6165978
22 November 2016
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6045896
1 August 2016
Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 5960998
23 May 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5885061
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 June 2026
No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. MI observed potential thinning out of the bottom plate in the lazarette bottom hull. Operator is to conduct 3rd party gauging of the bottom plate in the lazarette and provide plan to repair any wasted areas prior to credit hull inspection.
Action required: 705 - Other - as specified
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 December 2025
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter.
Vessel is not part of a consortium, and manages the drug and alcohol program on their own. Vessel needs to complete a full DAPI audit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2026
Resolution: Operator provided proof of DAPI enrollment and all documents required to comply with the requirements.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 December 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. MI observed pitting in the lazarette bottom hull and on the aft bulkhead in the tank room. MI is to conduct a full gauging to include any aluminum repairs prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2026
Resolution: MI gauged bottom plate and found pitting to be within acceptable limits.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 October 2025
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. MI observed that all four floating water lights on board had expired, or the wrong type, battery installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator replaced all floating waterlights with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 October 2025
Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. MI observed exposed form on one of the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator repaired the life floats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 October 2025
Resolved
A hatch exposed to the weather must be watertight. MI observed that the hatch going into the foc'sle had a gap in the gasket material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator replaced the gasket on the scuttle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2024
Resolved
A hatch cover must have securing devices. During the course of the inspection, a dog on the midships Freeman hatch to the lazarette broke off. Repair or replace hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Dog replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2024
No resolution recorded
[Life floats] with plastic foam buoyancy must have a plastic foam body with an external protective covering. The external protective covering for one of the life floats was worn and punctured in multiple locations. Repair covering or replace life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Two of the three floating electric waterlights attached to life floats were fraying and UV-damaged. Replace damaged lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Damaged lanyards were replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2024
Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Trash cans on board were constructed of combustible materials. Replace trash cans with noncombustible equivalents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Plastic trash cans replaced with metal bins.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Child life jackets were stowed in the same compartment as adult jackets with no separation. Stow separately or create physical barrier between adult and child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Plexiglass barrier installed between adult and child PFDs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 October 2024
Resolved
Whenever damage or deterioration to structural members is discovered, the cognizant OCMI may require the vessel to effect permanent repairs. The hydraulic steering ram support bracket has a popped weld where it meets the tank room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2025
Resolution: MI inspected new weld. Sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 October 2022
Resolved
VESSEL MUST UNDERGO AN ANNUAL INSPECTION WITHIN THE 3 MONTHS BEFORE OR AFTER THE ANNIVERSARY DATE. VESSEL IS BEYOND THE 3 MONTH LIMIT AND THE COI IS NO LONGER VALID. SUBMIT AN APPLICATION FOR INSPECTION FORM CG-3752 AND COMPLETE A SATISFACTORY COI INSPECTION.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2022
Resolved 11 October 2022
Resolution: Performed satisfactory COI inspection and issued temp COI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 January 2021
Resolved
Batteries must be protected from falling objects. Neither of the two battery banks have a protective cover installed. Ensure that the batteries are protected from falling objects.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 4 February 2021
Resolution: Received photos of the newly installed box covers.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2020
Resolved
As appropriate for the intended voyage, a vessel must carry equate and up to date: Charts of large enough scale to make safe navigation possible; U.S Coast Pilot or similar publication; Coast Guard Light List; tide tables; and current tables. The operator of each self-propelled vessel 12 meters
or more in length shall carry, on board and maintain for
ready reference, a copy of these Rules. The vessel did not have up to date Coast Pilots, Charts, and Navigation Rules.
46 CFR 183.420
33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: Missing publications were purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2020
Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel only had one fire bucket. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: NEw fire buckets were purchased and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 June 2020
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly
letters and numbers on each container for life jackets
and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Life jacket stowage containers did not say “life jackets.” 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: Stenciling was added to the life jacket stowage containers.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 June 2018
Resolved
Vessels pre engineered fire system does not shutdown A/C generator. Prove proper operation of fixed fire fighting system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Operationally tested pre engineered fire sytem and shutdown of M/Es and generator.
Engineering › Bilge Water Management System › Strainer
Issued 11 June 2018
Resolved
Renew bilge strainers in tank room and lazerett.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Verified installation of new bilge strainers.
Documentation › Certificates/Documents › Stability Letter
Issued 23 May 2016
Resolved
Stability letter missing. Provide copy of stability letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 24 May 2016
Resolution: Provided copy of stability letter to vessle owners.
Engineering › Steering Gear System › Fastener
Issued 23 May 2016
Resolved
Cotter pin missing on STBD rudder post. Install cotter pin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 23 May 2016
Resolution: New cotter Pin was installed.
Engineering › Bilge Water Management System › Piping
Issued 23 May 2016
Resolved
Missing check valves in bilge system. Install check valves in bilge system during next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Resolution: Check valves installed in bilge system at the manifold in the engine room.