ISLAND TIME

ISLAND TIME is a 2001 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in December 2025, along with 22 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2025. Most recent: inspection, 4 December 2025.

Built
2001
Last inspected
4 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 December 2025
…with no type recorded1
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD2430
Flag
UNITED STATES
Maury page id
psix-27243

Documentation record

Registered dimensions (L × B × D)48.0 ft × 15.2 ft × 7.8 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWINNINGHOFF BOATS INC · ROWLEY, MA, UNITED STATES · built 2001
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEWBURY, MA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 20 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

22 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 22

4 December 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8277279
23 October 2025 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8255529
4 April 2025 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8108702
20 November 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8034100
10 October 2024 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8016806
24 October 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7809978
30 May 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7700234
28 November 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7597949
3 October 2022 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7570483
16 September 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7303306
8 June 2021 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7219322
21 January 2021 Drydock Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7128978
24 June 2020 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6984125
1 May 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6946861
13 September 2019 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6811086
28 August 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6794732
29 November 2018 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6589074
11 June 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6436859
6 June 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6165978
22 November 2016 Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6045896
1 August 2016 Type not recorded
No type recorded · Station Gloucester · USCG Northeast District (CGD-NE) · Activity 5960998
23 May 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5885061

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 June 2026 No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. MI observed potential thinning out of the bottom plate in the lazarette bottom hull. Operator is to conduct 3rd party gauging of the bottom plate in the lazarette and provide plan to repair any wasted areas prior to credit hull inspection.
Action required: 705 - Other - as specified
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 December 2025 Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Vessel is not part of a consortium, and manages the drug and alcohol program on their own. Vessel needs to complete a full DAPI audit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2026
Resolution: Operator provided proof of DAPI enrollment and all documents required to comply with the requirements.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 1 December 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. MI observed pitting in the lazarette bottom hull and on the aft bulkhead in the tank room. MI is to conduct a full gauging to include any aluminum repairs prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 June 2026
Resolution: MI gauged bottom plate and found pitting to be within acceptable limits.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 October 2025 Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. MI observed that all four floating water lights on board had expired, or the wrong type, battery installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator replaced all floating waterlights with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 October 2025 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. MI observed exposed form on one of the life floats.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator repaired the life floats.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 October 2025 Resolved
A hatch exposed to the weather must be watertight. MI observed that the hatch going into the foc'sle had a gap in the gasket material.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Operator replaced the gasket on the scuttle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 October 2024 Resolved
A hatch cover must have securing devices. During the course of the inspection, a dog on the midships Freeman hatch to the lazarette broke off. Repair or replace hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Dog replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2024 No resolution recorded
[Life floats] with plastic foam buoyancy must have a plastic foam body with an external protective covering. The external protective covering for one of the life floats was worn and punctured in multiple locations. Repair covering or replace life float.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 October 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Two of the three floating electric waterlights attached to life floats were fraying and UV-damaged. Replace damaged lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Damaged lanyards were replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 October 2024 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Trash cans on board were constructed of combustible materials. Replace trash cans with noncombustible equivalents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Plastic trash cans replaced with metal bins.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets. Child life jackets were stowed in the same compartment as adult jackets with no separation. Stow separately or create physical barrier between adult and child life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 October 2024
Resolved 24 October 2024
Resolution: Plexiglass barrier installed between adult and child PFDs.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 October 2024 Resolved
Whenever damage or deterioration to structural members is discovered, the cognizant OCMI may require the vessel to effect permanent repairs. The hydraulic steering ram support bracket has a popped weld where it meets the tank room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2025
Resolution: MI inspected new weld. Sat
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 October 2022 Resolved
VESSEL MUST UNDERGO AN ANNUAL INSPECTION WITHIN THE 3 MONTHS BEFORE OR AFTER THE ANNIVERSARY DATE. VESSEL IS BEYOND THE 3 MONTH LIMIT AND THE COI IS NO LONGER VALID. SUBMIT AN APPLICATION FOR INSPECTION FORM CG-3752 AND COMPLETE A SATISFACTORY COI INSPECTION.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2022
Resolved 11 October 2022
Resolution: Performed satisfactory COI inspection and issued temp COI.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 21 January 2021 Resolved
Batteries must be protected from falling objects. Neither of the two battery banks have a protective cover installed. Ensure that the batteries are protected from falling objects.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2021
Resolved 4 February 2021
Resolution: Received photos of the newly installed box covers.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 June 2020 Resolved
As appropriate for the intended voyage, a vessel must carry equate and up to date: Charts of large enough scale to make safe navigation possible; U.S Coast Pilot or similar publication; Coast Guard Light List; tide tables; and current tables. The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these Rules. The vessel did not have up to date Coast Pilots, Charts, and Navigation Rules. 46 CFR 183.420 33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: Missing publications were purchased.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 June 2020 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel only had one fire bucket. 46 CFR 181.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: NEw fire buckets were purchased and labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 24 June 2020 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly letters and numbers on each container for life jackets and immersion suits. Letters and numbers must be at least 50 millimeters (2 inches) high. Life jacket stowage containers did not say “life jackets.” 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 24 June 2020
Resolution: Stenciling was added to the life jacket stowage containers.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 11 June 2018 Resolved
Vessels pre engineered fire system does not shutdown A/C generator. Prove proper operation of fixed fire fighting system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Operationally tested pre engineered fire sytem and shutdown of M/Es and generator.
Engineering › Bilge Water Management System › Strainer
Issued 11 June 2018 Resolved
Renew bilge strainers in tank room and lazerett.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2018
Resolved 15 June 2018
Resolution: Verified installation of new bilge strainers.
Documentation › Certificates/Documents › Stability Letter
Issued 23 May 2016 Resolved
Stability letter missing. Provide copy of stability letter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 24 May 2016
Resolution: Provided copy of stability letter to vessle owners.
Engineering › Steering Gear System › Fastener
Issued 23 May 2016 Resolved
Cotter pin missing on STBD rudder post. Install cotter pin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 23 May 2016
Resolution: New cotter Pin was installed.
Engineering › Bilge Water Management System › Piping
Issued 23 May 2016 Resolved
Missing check valves in bilge system. Install check valves in bilge system during next drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Resolution: Check valves installed in bilge system at the manifold in the engine room.