MATT JEANFREAU ELEVATOR

MATT JEANFREAU ELEVATOR is a 1986 offshore supply vessel. The Coast Guard has recorded 49 inspections since 1990, most recently in September 2023, along with 81 deficiencies — 2 with no resolution recorded —.

Records from 1990 to 2023. Most recent: inspection, 7 September 2023.

Built
1986
Last inspected
7 September 2023
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

-------
272573
Flag
UNITED STATES
—
Maury page id
psix-272573

Inspections, by type

…with no type recorded7
Years with a record 29 calendar years (1990–2023)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)63.1 ft × 40.1 ft × 5.8 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAI5617MMSI not assigned · expired · voluntarily equipped · granted 22 November 1994, cancelled 2 April 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 49

7 September 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7787330
14 June 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7476990
1 July 2021 In-Service Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7241825
8 January 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6884929
4 December 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6867305
15 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6684316
30 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6464090
1 March 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6096798
19 May 2016 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5881189
26 April 2016 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5863389
28 August 2014 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4966829
27 August 2014 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4966040
3 May 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4301133
21 July 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4088247
6 July 2009 Internal Structural Exam · Deficiency Check · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3521343
28 May 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3220095
8 March 2007 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2884148
25 May 2006 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2658392
20 June 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2396256
3 June 2004 Hull Examination · Internal Structural Exam · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2087433
30 January 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1737442
7 August 2002 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1657912
7 June 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1657237
24 January 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1480955
19 July 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467226
28 May 1999 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404765
7 July 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444030
23 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364282
22 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758949
19 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666048
16 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 196933
7 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214941
7 June 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1360584
21 December 1995 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374489
27 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 36396
21 July 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882632
16 June 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402054
6 September 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 864183
15 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1179406
9 May 1994 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467416
19 January 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1161738
1 May 1992 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254298
5 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257804
11 April 1991 Re-Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1218460
19 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904709
17 October 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 907194
30 April 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1232787
16 January 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920606
16 January 1990 Hull Examination · Initial Certification · Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241612

Deficiency record · 81

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 September 2023 Resolved
Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered lights and shall have sufficient capacity for 6 hours continuous operation. Vessel's emergency lights only had one battery to power 10-12 E-Lights and lasted less than 15 min.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2023
Resolution: Verified installation of E-Light batteries.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 September 2023 Resolved
Vessel shall have adequate and up-to-date charts and publications. Vessel had charts dated 24JUL2023 and not been updated since printing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 20 September 2023
Resolution: Verified Chart Correction updated.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2023 Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Vessel had large amount of machinery oil that was dripping from and pooling under the port MDE. 46CFR182.01-5
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: Crew cleaned up pooled oil in bilge.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 September 2023 Resolved
The name of a vessel must be marked or painted on each life float. Vessel did not have the name marked or painted on the stbd life float.
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: STBD lifefloat stenciled with vessel's name.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 June 2022 Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was operating past their COI expiration date. 46 CFR 176.100(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Vessel has a Temp COI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2022 Resolved
The owner, charterer, managing operator, or master must keep a correct list of the names of all persons that embark on and disembark from the vessel. Vessel was not maintaining a list of names of all crew and passengers on board. 46 CFR 185.502(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Vessel has started new logbook and indicated who is onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 14 June 2022 Resolved
Vessel must have the minimum compliment of officers and crew. Vessel was operating without the proper manning as indicated on COI while underway and not properly logging if they were attached to a platform providing security. 46 CFR 15.501(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Vessel will have til next inspection to prove logbook entries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner to afford adequate protection from causing fire, explosion or personnel injury. STBD MDE lube oil spraying from container with oil soaked rags and over electrical junction box. 46 CFR 182.100
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: STBD MDE was repaired and oil cleaned up.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 June 2022 Resolved
Sidelights shall show on an unbroken arc of the horizon of 112.5 degrees. Starboard navigation light was missing bolts, causing the light to be turned over. 46 CFR 83.21(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Nav Light was bolted down.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 June 2022 Resolved
Watertight doors must be made watertight. Portside engine room hatch to rudder room, portside main deck hatch to engine room, and portside rudder hatch would not close properly. 46 CFR 179.360(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2022
Resolution: Vessel adjusted doors and changed gaskets to rubber to the satisfaction of the MI.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 June 2022 Resolved
Each vessel must be equipped with a public address system. Public address system was disconnected internally. 46 CFR 184.610(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Vessel fixed the PA system to be able to hear in accomidations and galley.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 June 2022 Resolved
Rails must be installed near the periphery of decks of a vessel accessible to passengers or crew. Rails wasted around bow leg; missing chains in multiple places; missing rail on stbd side; port side rail is loose and wobbly with port life float. 46 CFR 177.900 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Vessel had reparied or replaced all damaged/ wasted railings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Light was missing globe and bulb and junction box in starboard rudder room was open. 46 CFR 183.01-15 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Vessel had installed a cover for the electrical.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 June 2022 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck. Light and armored cable was hanging in the starboard rudder room emergency escape. 46 CFR 183.432(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Lighting was fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022 Resolved
Batteries shall be checked for condition and security stowage. Batteries were not in a case or properly stowed. 46 CFR 176.25-15(a)(5) (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2022
Resolution: All batteries were properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 June 2022 No resolution recorded
Each EPIRB must be tested monthly and shall be logged. Missing over one year of logs for EPIRB testing. 705- Vessel will have until next Annual Inspection to prove vessel was preforming required Lifesaving and Firefighting Checks. 46 CFR 185.728
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 June 2022 Resolved
The minimum capacity of the fire pump must be at a pressure of not less than 60 psi at the pump outlet. Fire Pump Overboard discharge ball valve not closing properly allowing stream to escape and not reach 60PSI. 46 CFR 181.300 (b)
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Vessel changed out the ball valve that was leaking.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 June 2022 Resolved
Vessel shall be provided with safe, readily available and sufficient firefighting equipment. Galley smoke detector was inoperable. 46 CFR 181.01-5 (Old-T)
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Vessel replaced the old smoke detector with a new unit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 14 June 2022 Resolved
Freeboard markings must be permanently scribed and painted white or yellow on a dark background. Vessel did not have the freeboard markings painted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 14 July 2022
Resolution: Vessel had painted freeboard marks.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2022 No resolution recorded
Each crane must be inspected and tested IAW API RP 2D. Vessel did not log crane usage or pre-inspection checks for multiple months. 705 - Vessel will have until next annual inspection to prove proper logs.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2021 Resolved
The following worklist items are to be completed prior to issuing drydock and internal structural examination credit: 1.) Starboard leg platform: repair cracks and renew as original 2.) Starboard leg sponson: Repair crack 3.) Starboard generator exhaust hanger: Renew as original 4.) Port generator exhaust hanger: Renew as original. 5.) Port side tank space cable penetration: Reseal to make watertight 6.) Starboard tank space: 03 longitudinals warped and damaged: renew as original 7.) Replace oil in the following gearboxes: a.) Port Gearbox #1 b.) Port Gearbox #2 c.) Port Gearbox #3 d.) Starboard Gearbox #2 e.) Bow Gearbox #2 f.) Bow Gearbox #3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2021
Resolution: Reattended the vessel and confirmed that all items were completed to the satisfactory of the CG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2019 Resolved
A hatch exposed to the weather must be watertight. The doors leading to and the emergency escape hatches leading from the port and starboard engine rooms did not have watertight gaskets. 46 CFR 179.360; 17c.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2019
Resolved 17 May 2019
Resolution: Gaskets replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019 Resolved
At each inspection, the following fire protection equipment shall be ready for inspection: fixed gas extinguishing systems for corrosion and general condition. The paint locker had 7 holes drilled into it from a previous mounting arrangement. 46 CFR 176.810; 16c.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 17 May 2019
Resolution: Holes in paint locker welded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019 Resolved
At each inspection, the following fire protection equipment shall be ready for inspection: operation of the fire main system. The fire hose connected to the submersible pump ruptured under pressure. Vessel had spare hose on-board and replaced to the satisfaction of the attending MI. 46 CFR 176.810; 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2019
Resolved 15 May 2019
Resolution: Vessel had a replacement hose in the equipment locker and replaced in the presence of the MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 10 August 2018
Resolution: Rescinded 835. A FCC Station License is not required because the vessel is less than 65', less than 100gt, and not on an international voyage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 May 2018 Resolved
Replace gasket on the Engine Roon watertight door.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 30 June 2018
Resolved 31 May 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2018 Resolved
Replace the following non-metallic flexible hoses: Stbd hydraulic steering; 6-fuel hoses on the stbd MDE; Stbd SSDG fuel supply; Port MDE fuel supply; 22-port crane hydraulic hoses.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 31 May 2018
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 August 2014 Resolved
Provide adequate bilge high level alarm visual indications in pilot house IAW 46 CFR 182.530.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2014
Resolution: [name withheld] witnessed proper function of bilge high level alarms.
Fire Fighting › Means of Escape › Stairways
Issued 28 August 2014 Resolved
Provide adequate egress route for both port and starboard engine room accesses IAW 46 CFR 177.500.
Due 4 September 2014
Resolved 29 August 2014
Resolution: [name withheld] attended vessel and witnessed adequate space for egress from engine rooms.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 May 2012 Resolved
Repair exhaust lagging on port MDE and STBD SSDG.
Action required: 705 - Other - as specified
Resolved 3 May 2012
Resolution: Exhaust lagging repaired.
Communications › Radio Communications › EPIRB
Issued 3 May 2012 Resolved
EPIRB battery expired.
Action required: 705 - Other - as specified
Resolved 11 May 2012
Resolution: EPIRB battery replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 July 2011 Resolved
Replace inop waterlight.
Action required: 705 - Other - as specified
Resolved 27 July 2011
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 July 2011 Resolved
Drills have not been properly conducted and logged. Log drills to be viewed by CG inspector next exam.
Action required: 705 - Other - as specified
Resolved 3 May 2012
Resolution: Vessel''s captain has been properly logging required drills.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 July 2011 Resolved
Test and properly log inspections of EPIRP
Action required: 705 - Other - as specified
Resolved 3 May 2012
Resolution: Monthly logging of the EPIRB has been conducted.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 21 July 2011 Resolved
Replace lagging where missing on exhaust pipes of main engines.
Action required: 705 - Other - as specified
Resolved 27 July 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 6 July 2009 Resolved
Demonstrate proper operation of vsl's port MDE voltmeter.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2009
Electrical › Electrical Distribution System (service) › Cable
Issued 6 July 2009 Resolved
Remove powerstrip used as permanent wiring in master's stateroom.
Action required: 705 - Other - as specified
Resolved 7 July 2009
Electrical › Electric Generation Source (service) › Generator
Issued 6 July 2009 Resolved
Demonstrate proper operation of vsl's port generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2009
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 July 2009 Resolved
Repair leaking seal on port shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 6 July 2009 Resolved
Provide a working light above each rack onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2008 Resolved
Eliminate exposed wiring on generator batteries.
Due 28 June 2008
Resolved 2 June 2008
Electrical › Electric Generation Source (service) › Generator
Issued 28 May 2008 Resolved
Renew lagging on both port and stbd generators.
Due 28 June 2008
Resolved 2 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 May 2008 Resolved
Renew lagging on stbd MDE.
Due 28 June 2008
Resolved 2 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 28 May 2008 Resolved
Repair fuel leaks on STBD MDE.
Due 28 June 2008
Resolved 2 June 2008
Stability › Watertight Integrity › General
Issued 28 May 2008 Resolved
Install watertight gaskets on all watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2008
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 25 May 2006 Resolved
Make permanent repairs to starboard framing in tank compartment prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Deck/Cargo › Holds/Tanks › Coaming
Issued 25 May 2006 Resolved
Install gaskets on all hatches as marked prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2006 Resolved
Repair all stuffing tubes as discussed.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 25 May 2006 Resolved
Clean generator armatures port and starb sets.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Lifesaving › Buoyant Apparatus › Float Free
Issued 25 May 2006 Resolved
re ring life floats for float free arrangement
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Engineering › Bilge Water Management System › Not Installed
Issued 25 May 2006 Resolved
Provide visual bilge alarms for each space served at the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 25 May 2006 Resolved
Provide current compass diviation card
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 May 2006 Resolved
Wrap exhaust manifolds on mains.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 25 May 2006 Resolved
Provide and isntall guard for strb generator flywheel and sewage pump shaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT
Communications › Internal Communications System › Sound-powered Telephone
Issued 25 May 2006 Resolved
Provide public address system
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Accommodation/Occupational Safety › Ventilation › General
Issued 25 May 2006 Resolved
Provide light guard for stove.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 25 May 2006 Resolved
Repair panel board for galley
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 May 2006 Resolved
Remove extra box for galley a.c unit.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2006
Resolved 27 May 2006
Resolution: ALL SAT.
Construction/Loadline › Hull › Hull Plating
Issued 3 June 2004 Resolved
Crop and renew to good metal, as original, hull plating where marked.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2004
Resolution: All marked repairs to hull plating completed sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 January 2003 Resolved
Replace missing / deteriorated exhaust insulation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2003
Resolution: Insulation replaced.
Engineering › Bilge Water Management System › Piping
Issued 30 January 2003 Resolved
Replace flex hose in system as necessary.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2003
Resolution: Hose replaced.
Construction/Loadline › Hull › Weld
Issued 30 January 2003 Resolved
Weld interior of main deck over main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 February 2003
Resolution: Welding completed.
Communications › Radio Communications › EPIRB
Issued 24 January 2002 Resolved
RENEW OR SERVICE EPIRB FOR EXPIRED BATTERY.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2002
Resolved 24 January 2002
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 24 January 2002 Resolved
SECURE WASHER AND DRYER.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 January 2002
Resolved 24 January 2002
Construction/Loadline › Structures › Door
Issued 24 January 2002 Resolved
RENEW WATER TIGHT DOOR AND HATCH GASKETS THROUGH OUT VESSEL.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2002
Resolved 24 January 2002
Lifesaving
Issued 28 May 1999 Resolved
DEMONSTRATE COMPLIANCE WITH THE 8TH COAST GUARD POLICY LETTER "RESCUE BOATSON OFFSHORE SUPPLY VESSELS DATED 12 NOV 98 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 16 June 1995 Resolved
PROPERLY INSTALL & PROVE OPERATION OF A TILT ALARM ACCEPTABLE TO THE COGNIZANT OCMI.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Documentation
Issued 15 July 1994 Resolved
PROVIDE COPY OF STABILITY LETTER.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Documentation
Issued 15 July 1994 Resolved
PROVIDE APPROVED COPY OF OPERATING MANUAL.
Condition: Unknown
Due 15 July 1994
Resolved 15 July 1994
Documentation
Issued 9 May 1994 Resolved
SUBMIT UPDATED OPERATION MANUAL FOR REVIEW AND APPROVAL TO MARINE SAFETY CENTER WASHINGTON, DC.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Documentation
Issued 9 May 1994 Resolved
SUBMIT STABILITY LETTER FOR REVIEW TO MARINE SAFETY CENTER WASHINGTON, DC.
Condition: Unknown
Due 9 May 1994
Resolved 9 May 1994
Lifesaving
Issued 16 January 1990 Resolved
PROVIDE A U.S. COAST GUARD APPROVED RESCUE BOAT.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Lifesaving
Issued 16 January 1990 Resolved
Provide a U.S. Coast Guard approved rescue boat or submit alternative proposal for approval.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Lifesaving
Issued 16 January 1990 Resolved
Provide embarkation means to escape from vessel when in the elevated mode,_x001C_See 46 CFR 108.525.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Navigation
Issued 16 January 1990 Resolved
Calibrate magnetic compass and submit deviation table to [name withheld].
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Construction/Loadline
Issued 16 January 1990 Resolved
Submit documentation to the U.S. Coast Guard Marine Safety Center, WASHINGTON, D.C. THAT PROVES DOORS INSTALLED IN LONGITUDINAL AND TRANSVERSEbulkheads comply with 46 CFR 170.270 (b).
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
Submit stability calculations to the U.S. Coast Guard Marine Safety Center,Washington, D.C. for review and approval.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
Submit a copy of readmeasurement certificate to [name withheld], see 46 CFR 69.19.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
Provide approved plans as required by item 1 to the cognizant OCMI.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
Submit the following plans for approval by the U.S. Coast Guard Marine Safety Center, Washington, D.C.: Inboard and outboard profiles, leg structural support and leg strength criteria, hydraulic jacking system details including alarms and controls.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Documentation
Issued 16 January 1990 Resolved
SUBMIT AN OPERATING MANUAL FOR REVIEW AND APPROVAL BY THE U. S. COAST GUARDMARINE SAFETY CENTER, WASHINGTON, D.C. VESSEL IS PERMITTED TO OPERATE ON ITS EXISTING OPERATING MANUAL UNTIL THE U.S. COAST GUARD APPROVED OPERATING MANUAL IS RECEIVED.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990

Ownership record