This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 September 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

-------
272573
Flag
UNITED STATES
Maury page id
psix-272573

Documentation record

Registered dimensions (L × B × D)63.1 ft × 40.1 ft × 5.8 ft
Registered tonnagegross 98 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS INC · CAERNARVON, LA, UNITED STATES · built 1986
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 June 2026 · expires 30 June 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 10 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each, 2 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

7 September 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7787330
14 June 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7476990
1 July 2021 In-Service Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7241825
8 January 2020 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6884929
4 December 2019 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6867305
15 May 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6684316
30 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6464090
1 March 2017 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6096798
19 May 2016 Hull Examination · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5881189
26 April 2016 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5863389

Deficiency record · 27

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 September 2023 Resolved
Vessels not equipped with a single source emergency lighting system shall have individual storage battery powered lights and shall have sufficient capacity for 6 hours continuous operation. Vessel's emergency lights only had one battery to power 10-12 E-Lights and lasted less than 15 min.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2023
Resolution: Verified installation of E-Light batteries.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 September 2023 Resolved
Vessel shall have adequate and up-to-date charts and publications. Vessel had charts dated 24JUL2023 and not been updated since printing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 October 2023
Resolved 20 September 2023
Resolution: Verified Chart Correction updated.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 September 2023 Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. Vessel had large amount of machinery oil that was dripping from and pooling under the port MDE. 46CFR182.01-5
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: Crew cleaned up pooled oil in bilge.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 September 2023 Resolved
The name of a vessel must be marked or painted on each life float. Vessel did not have the name marked or painted on the stbd life float.
Action required: 10 - Deficiency Rectified
Resolved 7 September 2023
Resolution: STBD lifefloat stenciled with vessel's name.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 June 2022 Resolved
A vessel may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. Vessel was operating past their COI expiration date. 46 CFR 176.100(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Vessel has a Temp COI.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2022 Resolved
The owner, charterer, managing operator, or master must keep a correct list of the names of all persons that embark on and disembark from the vessel. Vessel was not maintaining a list of names of all crew and passengers on board. 46 CFR 185.502(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Vessel has started new logbook and indicated who is onboard.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 14 June 2022 Resolved
Vessel must have the minimum compliment of officers and crew. Vessel was operating without the proper manning as indicated on COI while underway and not properly logging if they were attached to a platform providing security. 46 CFR 15.501(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Vessel will have til next inspection to prove logbook entries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner to afford adequate protection from causing fire, explosion or personnel injury. STBD MDE lube oil spraying from container with oil soaked rags and over electrical junction box. 46 CFR 182.100
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: STBD MDE was repaired and oil cleaned up.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 June 2022 Resolved
Sidelights shall show on an unbroken arc of the horizon of 112.5 degrees. Starboard navigation light was missing bolts, causing the light to be turned over. 46 CFR 83.21(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2022
Resolution: Nav Light was bolted down.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 June 2022 Resolved
Watertight doors must be made watertight. Portside engine room hatch to rudder room, portside main deck hatch to engine room, and portside rudder hatch would not close properly. 46 CFR 179.360(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2022
Resolution: Vessel adjusted doors and changed gaskets to rubber to the satisfaction of the MI.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 14 June 2022 Resolved
Each vessel must be equipped with a public address system. Public address system was disconnected internally. 46 CFR 184.610(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Vessel fixed the PA system to be able to hear in accomidations and galley.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 14 June 2022 Resolved
Rails must be installed near the periphery of decks of a vessel accessible to passengers or crew. Rails wasted around bow leg; missing chains in multiple places; missing rail on stbd side; port side rail is loose and wobbly with port life float. 46 CFR 177.900 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Vessel had reparied or replaced all damaged/ wasted railings.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Light was missing globe and bulb and junction box in starboard rudder room was open. 46 CFR 183.01-15 (Old T)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Vessel had installed a cover for the electrical.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 June 2022 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck. Light and armored cable was hanging in the starboard rudder room emergency escape. 46 CFR 183.432(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2022
Resolution: Lighting was fixed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 June 2022 Resolved
Batteries shall be checked for condition and security stowage. Batteries were not in a case or properly stowed. 46 CFR 176.25-15(a)(5) (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2022
Resolution: All batteries were properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 June 2022 No resolution recorded
Each EPIRB must be tested monthly and shall be logged. Missing over one year of logs for EPIRB testing. 705- Vessel will have until next Annual Inspection to prove vessel was preforming required Lifesaving and Firefighting Checks. 46 CFR 185.728
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 14 June 2022 Resolved
The minimum capacity of the fire pump must be at a pressure of not less than 60 psi at the pump outlet. Fire Pump Overboard discharge ball valve not closing properly allowing stream to escape and not reach 60PSI. 46 CFR 181.300 (b)
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Vessel changed out the ball valve that was leaking.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 14 June 2022 Resolved
Vessel shall be provided with safe, readily available and sufficient firefighting equipment. Galley smoke detector was inoperable. 46 CFR 181.01-5 (Old-T)
Action required: 10 - Deficiency Rectified
Resolved 14 June 2022
Resolution: Vessel replaced the old smoke detector with a new unit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 14 June 2022 Resolved
Freeboard markings must be permanently scribed and painted white or yellow on a dark background. Vessel did not have the freeboard markings painted.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 July 2022
Resolved 14 July 2022
Resolution: Vessel had painted freeboard marks.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 June 2022 No resolution recorded
Each crane must be inspected and tested IAW API RP 2D. Vessel did not log crane usage or pre-inspection checks for multiple months. 705 - Vessel will have until next annual inspection to prove proper logs.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 July 2021 Resolved
The following worklist items are to be completed prior to issuing drydock and internal structural examination credit: 1.) Starboard leg platform: repair cracks and renew as original 2.) Starboard leg sponson: Repair crack 3.) Starboard generator exhaust hanger: Renew as original 4.) Port generator exhaust hanger: Renew as original. 5.) Port side tank space cable penetration: Reseal to make watertight 6.) Starboard tank space: 03 longitudinals warped and damaged: renew as original 7.) Replace oil in the following gearboxes: a.) Port Gearbox #1 b.) Port Gearbox #2 c.) Port Gearbox #3 d.) Starboard Gearbox #2 e.) Bow Gearbox #2 f.) Bow Gearbox #3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 July 2021
Resolution: Reattended the vessel and confirmed that all items were completed to the satisfactory of the CG.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2019 Resolved
A hatch exposed to the weather must be watertight. The doors leading to and the emergency escape hatches leading from the port and starboard engine rooms did not have watertight gaskets. 46 CFR 179.360; 17c.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2019
Resolved 17 May 2019
Resolution: Gaskets replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2019 Resolved
At each inspection, the following fire protection equipment shall be ready for inspection: fixed gas extinguishing systems for corrosion and general condition. The paint locker had 7 holes drilled into it from a previous mounting arrangement. 46 CFR 176.810; 16c.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2019
Resolved 17 May 2019
Resolution: Holes in paint locker welded.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019 Resolved
At each inspection, the following fire protection equipment shall be ready for inspection: operation of the fire main system. The fire hose connected to the submersible pump ruptured under pressure. Vessel had spare hose on-board and replaced to the satisfaction of the attending MI. 46 CFR 176.810; 10c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 May 2019
Resolved 15 May 2019
Resolution: Vessel had a replacement hose in the equipment locker and replaced in the presence of the MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2018 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 10 August 2018
Resolution: Rescinded 835. A FCC Station License is not required because the vessel is less than 65', less than 100gt, and not on an international voyage.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 May 2018 Resolved
Replace gasket on the Engine Roon watertight door.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 30 June 2018
Resolved 31 May 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 May 2018 Resolved
Replace the following non-metallic flexible hoses: Stbd hydraulic steering; 6-fuel hoses on the stbd MDE; Stbd SSDG fuel supply; Port MDE fuel supply; 22-port crane hydraulic hoses.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2018
Resolved 31 May 2018