Records from 1986 to 1997. Most recent: inspection, 19 May 1997.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting
Issued 19 May 1997
Resolved
PROVIDE CLASS ACCEPTANCE OF PROPER OPERATION OF FIRE SCREEN DOORS IN STAIR TOWER. DOORS FAILED TO PROPERLY CLOSE ON DECKS A-D.
Condition: Unknown
Due 20 May 1997
Resolved 21 May 1997
Electrical
Issued 19 May 1997
Resolved
REPAIR LIGHTING IN PROPELLOR SHAFT ALLEY ESCAPE. INOPERATIVE LIGHT FIXTURES LEFT NO LIGHTING IN SHAFT ALLEY ESCAPE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Engineering
Issued 19 May 1997
Resolved
REPAIR CONTAINMENT AROUND #3 PORT FUEL OIL VENT.
Condition: Unknown
Due 20 May 1997
Resolved 21 May 1997
Engineering
Issued 19 May 1997
Resolved
PROVE PROPER ARRANGEMENT OF BOLTS IN STARBOARD BUNKERING PIPE BLIND FLANGE.BOLTS FAILED TO BE IN AT LEAST EVERY OTHER HOLE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 19 May 1997
Resolved
REPAIR LIGHTS IN FOWARD BOS'N LOCKER. LIGHTS INOPERATIVE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Fire Fighting
Issued 19 May 1997
Resolved
FIRE CONTROL PLAN FAILED TO SHOW LOCATION OF INTERNATIONAL SHORE CONNECTION. ISC WAS ACTUALLY LOCATED ON BRIDGE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Electrical
Issued 19 May 1997
Resolved
REPLACE GLOBES FOR LIGHT FIXTURES IN PORT LIFEBOAT DECK TOOL ROOM (AFT). LIGHT FIXTURES HAVE BARE LIGHT BULBS.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 19 May 1997
Resolved
REMOVE OIL FROM STEERING GEAR ROOM DECK.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 19 May 1997
Resolved
REPAIR DECK PLATE SUPPORT IN PROPELLOR SHAFT ALLEY UNDER ESCAPE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 19 May 1997
Resolved
REPAIR ALARM FOR SLIDING WATERTIGHT DOOR IN ENGINE ROOM. INOPERABLE ALARM ON SHAFT ALLEY WATERTIGHT DOOR.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Engineering
Issued 19 May 1997
Resolved
PROVE PROPER OPERATION OF OIL MIST DETECTOR ON MAIN ENGINE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Lifesaving
Issued 19 May 1997
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS TO SATISFACTION OF ATTENDING CG B/O._x001C_ CREW VERY DISORGANIZED DURING DRILLS. EQUIPMENT FORGOTTEN, PERSONNEL UNSURE OF DUTIES.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Navigation
Issued 3 September 1986
Resolved
VESSEL DID NOT HAVE THE INSTRUCTIONS AND BLOCK DIAGRAM SHOWING THE CHANGEOVER PROCEDURES TO REMOTE STEERING GEAR LOCATIONS POSTED ON THE NAVIGATING BRIDGE OR IN THE STEERING GEAR ROOM.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Navigation
Issued 3 September 1986
Resolved
VESSEL FAILED TO HAVE THE MANEUVERING INFORMATION REQUIRED POSTED ON THE NAVIGATING BRIDGE.
Condition: Unknown
Due 20 May 1997
Resolved 20 May 1997
Documentation
Issued 3 September 1986
Resolved
VESSELS OIL TRANSFER PROCEDURES WERE MISSING THE FOLLOWING ITEMS: PROCEDURES FOR OPERATING EMERGENCY SHUTDOWN, TOPPING OFF TANKS, REPORTING DISCHARGES, AND THE PRODUCT INFORMATION.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Navigation
Issued 3 September 1986
Resolved
VESSEL HAS ON BOARD A 1985 BRITISH ADMIRIALTY LIGHT LIST THAT CONTAINS NO CORRECTIONS FROM NOTICE TO MARINERS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986
Navigation
Issued 3 September 1986
Resolved
VESSEL FAILED TO CONDUCT THE EQUIPMENT TESTS REQUIRED BY 33CFR164.25(A) WITHIN 12 HOURS OF ENTERING U.S. WATERS.
Condition: Unknown
Due 3 September 1986
Resolved 3 September 1986