MAURY USCG vessel records Sign in
← All vessels

SOUND BOUND ODYSSEY

SOUND BOUND ODYSSEY is a 1986 passenger vessel (inspected). The Coast Guard has recorded 78 inspections since 1986, most recently in April 2026, along with 205 deficiencies and 7 casualty investigations between 2005 and 2022.

Records from 1986 to 2026. Most recent: inspection, 13 April 2026.

Built
1986
Last inspected
13 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ9374
272822
Flag
UNITED STATES
367426330
Maury page id
psix-272822

Inspections, by type

…with no type recorded7
Years with a record 35 calendar years (1986–2026)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)76.7 ft × 24.1 ft × 8.7 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC · PATTERSON, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ9374MMSI 367426330 · active · compulsorily equipped · granted 29 April 2026, expires 29 April 2036
WTV7572MMSI 367426330 · cancelled · compulsorily equipped · granted 6 November 2019, cancelled 27 April 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

USS CARTER HALL (LSD 50) Public Vessel, Unclassified · MISLE 608057 · 2 June 2022 · activity 7600514

Inspection history · 78

13 April 2026 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8347195
21 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8272310
21 October 2025 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8256164
10 June 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8156220
25 October 2024 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8024537
24 September 2024 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8008289
23 May 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7915430
2 January 2024 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7844186
8 October 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7806895
23 May 2023 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7688881
21 December 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7611646
16 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7560178
2 June 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7600514
12 April 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7421906
18 February 2022 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7398096
18 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7334656
28 August 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7300083
28 August 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7307204
24 June 2021 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7234400
21 April 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7155148
24 September 2020 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7064397
24 September 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7069499
13 August 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7049419
11 August 2020 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7030769
9 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6999832
23 January 2020 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6894452
30 August 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6850145
9 July 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6744301
12 June 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6712141
11 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6710822
19 July 2018 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6489092
12 March 2018 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6367878
11 March 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6097612
4 August 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5961879
14 March 2016 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5832536
4 August 2015 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5200990
19 August 2014 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4959315
25 March 2014 Deficiency Check · Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4819866
25 January 2011 Annual Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3928059
28 January 2010 Internal Structural Exam · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3666381
13 January 2009 Internal Structural Exam · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3393117
6 November 2007 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3094490
10 November 2005 Periodic Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2532581
4 November 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2235455
24 November 2003 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1956818
4 November 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1945013
6 November 2002 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1702831
18 December 2001 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1473728
6 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075865
1 November 2001 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1417407
13 December 1999 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1464898
3 November 1999 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1418618
5 November 1998 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1404634
9 December 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 777871
6 November 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1119342
6 January 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1096221
6 November 1996 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1463990
14 December 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458257
8 November 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1186286
29 March 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 836906
29 March 1995 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1133459
16 November 1994 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 868067
21 December 1993 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 849433
23 November 1993 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1153689
17 March 1993 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 834233
6 January 1993 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1132873
23 December 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1268872
2 October 1991 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 938292
2 January 1991 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1221550
13 March 1990 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1233449
9 February 1990 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 911240
4 January 1990 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 934922
24 January 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894372
3 August 1988 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1035210
7 March 1988 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1337197
5 August 1987 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1031000
13 January 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1317763
13 August 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309390

Deficiency record · 205

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2026 Resolved
Stations must have an authorization granted by the FCC. Vessel did not have station license or Bridge-to-Bridge Cert on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: FCC station license and Bridge-to-Bridge certs issued and onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers for life jackets. Letters and numbers must be at least (2 inches) high. Child life Jacket stowage was not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Child life jacket stowage labeled correctly.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 April 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers for life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Number of child life jacket labeled on Storage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2026 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguishers brackets not mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: All fire extinguisher mounts installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 April 2026 Resolved
Vessel did not have a logbook on board to document drills or tests. Get Logbook.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Log book onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2026 Resolved
Protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to the satisfaction of the cognizant [name withheld] shafts on Main Engines were exposed and open. May case crew injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Protective guards installed above both main engine shafts.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 June 2025 Resolved
A vessel on Oceans, coastwise or limited coastwise must carry 6 hand red flares and 6 orange smoke signals for a total of 12. You can substituted red for orange, so you can have all red. Vessel only had 9 flares on board. Must replace the 3 missing flares for a total of 12.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: 03 missing flares have been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2025 Resolved
FCC Safety Certificate expired May 25th 2025. Must renew FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: Updated FCC safety certifcate available and reviewed during inspection, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 June 2025 Resolved
Signage on aft ladder for passenger count on upper deck was broken and missing total passenger count. Replace broken signage to show max passenger count allowed on upper deck in accordance with stability letter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: Signage updated to show number of passengers permitted on upper deck. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 25 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices,fire hazards,and other hazardous situations must be corrected. Oil soaked lagging found on STBD inboard main engine turbocharger. Remove lagging and repair oil leaks. Install new lagging and make available to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2024
Resolution: Lagging has been cleaned. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Discovered multiple excessive oil leaks on both propulsion engines that present potential fire hazard. Correct oil leaks on both engines and perform sea trials to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 November 2024
Resolution: Excessive oil leaks have been addressed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 October 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. Excessive accumulation of oil was discovered in E/R bilges. Remove oil/debris from E/R bilges and clean to the satisfaction of the attending M/I.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 November 2024
Resolution: ER has been properly cleaned. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Renew broken alternator belt for port main engine. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2024
Resolution: Crew installed new belt. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards and electrical shock. Electrical panel in engine room presents electrical hazards due to missing breaker. Install a blank over spare breaker opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew installed blanks on electrical panel. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards and electrical shock. Electrical panel in galley is missing latch. Install new closing latch to breaker panel door.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew installed closing/locking device on panel door. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
This part contains requirements for the installation, and operation of electrical equipment and systems. Remove dead ended wires in way of both propulsion engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew removed dead end wires. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 October 2024 Resolved
Auxiliary machinery of the internal combustion piston type must comply with the provisions of this part. Generator has excessive jacket water leak. Make repairs and perform sea trials to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: J/W leak was addressed on SSDG. All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 October 2024 Resolved
The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. No. 1 void hatch hinge is cracked. Replace with in kind equipment and make available for attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew replaced hinge on void access door. All SAT.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 25 October 2024 Resolved
A vessel is inspected for compliance with the standards required by this sub chapter. Machinery, equipment, materials, and arrangements not covered by standards in this sub chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Approximately 38 gallons of bleach found in No. 2 void not properly secured. Move containers to another place preferable weather deck or locker to avoid potential chemical spill.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew removed bleach from space. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024 Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements: Flexible hose runs must be visible, easily accessible, protected from mechanical damage. L/O cooler flex hose is pinched on L/O filter housing. Adjust hose away from filter housing and replace hose if needed with in kind equipment. Make available for attending MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew replaced hose and readjusted angle.Crew installed shaffing gear on new hose. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2024 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. All five (05) life floats have meet their service life. Replace with in-kind equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024 Resolved
The requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) of this chapter. STBD main engine has a significant oil leak coming from F/W pump. Repair and provide finding to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024 Resolved
The requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) of this chapter. Outboard STBD main engine has a pinched jacket water house near thermostat. Repair and provide finding to attended MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 May 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Both Port and STBD main engines need guard over rotating machinery (belts) tighten.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 January 2024 Resolved
The construction of a vessel must allow the safe operations of the vessel giving consideration to provisions for a seaworthy hull. Fore peak: Identified 12" crack at #3 center joining frame. Make effective repair IAW proposed repair plan.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 January 2024
Resolution: MI's visually inspected completed repairs. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 January 2024 Resolved
The construction of a vessel must allow the safe operations of the vessel giving consideration to provisions for a seaworthy hull. Fore peak: Identified 6" crack on weld IVO #2 port-side frame. Gouge out and re-weld.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 January 2024
Resolution: MI's visually inspected completed repairs. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 2 January 2024 Resolved
A marine sanitation device must be designed to prevent the overboard discharge. Expansion tank for MSD was found wasted. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2024
Resolved 23 May 2024
Resolution: Vessel crew replaced tank with in-kind equipment. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 January 2024 Resolved
At every other inspection unsafe practices and other hazardous situations must be corrected. Port-side forward window in accommodation space was loose and not properly sealed. Make proper repairs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2024
Resolved 23 May 2024
Resolution: MI verified new gasket was installed around window. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 July 2023 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Newly appointed crew member was not familiar with fire drills.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 July 2023
Resolution: Crew conducted drills with new crewmember
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 July 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 02 main deck life ring buoys found discolored and severally weathered. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: MI witnessed new ring buoys. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 July 2023 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping to determine that the system is in operating condition. Piping elbow found clad welded. Make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: MI's witnessed proper repairs on fire main system. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. CO2 bottles in passenger comp and engine room were installed after 2016 and dont meet UL 2-A or 40 B:C. Install proper extinguishers in the passenger compartment in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: MI's witnessed new proper extinguishers. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 April 2022 Resolved
All vessels must have nav lights that are in compliance with the applicable sections of the nav rules. Port running light is inoperable. Prove to MI that light is operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2022
Resolved 14 April 2022
Resolution: Operator proved port running light is operational. All SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 12 April 2022 Resolved
An EAP training program must be conducted for the employers supervisor. Captain needs EAP training. Provide proof to MIs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 14 April 2022
Resolution: Captain provided proof that training was conducted. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2022 Resolved
Fill pipes must be suitably marked for identification. Fill location(s) on vessel must be marked.
Action required: 705 - Other - as specified
Due 19 April 2022
Resolved 14 April 2022
Resolution: Vessel clearly marked diesel fill pipes throughout. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2022 Resolved
Each battery must be secured to protect shifting with the roll and pitch of vessel. Spare battery was not secure. Secure battery.
Action required: 705 - Other - as specified
Due 19 April 2022
Resolved 14 April 2022
Resolution: Spare battery was secured in battery box with proper cover, all SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 April 2022 Resolved
A vessel must comply with the applicable requirements issued by the FCC. VHF radio is not integrated with GPS. Prove radio has GPS to attending inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 14 April 2022
Resolution: Vessel proved DSC fuction of the radio and provided a self-test by using MMSI number. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 February 2022 Resolved
The construction of a vessel must allow the safe operations of the vessel giving consideration to provisions for a seaworthy hull. Rod room: Crack in overhead port side aft as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: Weld gouged out and re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2021 Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without approval of the cognizant [name withheld] master reported a reduction of propulsion on the port main engine, while operating with passengers this date. Trouble shoot, make proper repairs and provide tech report with findings to the satisfaction of the Coast Guard. Prior to passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2021
Resolved 2 September 2021
Resolution: Aft blower, shaft, and chain replaced to the satisfaction of the attending inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 June 2021 Resolved
Master reported small leak on air conditioning thru hull fitting. Make proper repairs to the satisfaction of USCG
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2021
Resolution: New section of pipe installed and welded. NDT using dye pen and witnessed; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 June 2021 Resolved
Master reported #2 MDE #2 cylinder dropped two valves. Determine cause inspect for damage (further). Make proper repairs, conduct operation test to the satisfaction of the attending Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2021
Resolution: Repairs made to the #2 MDE and conducted underway sea trials.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 April 2021 Resolved
Properly post COI under glass.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2021 Resolved
Properly post the stability letter.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 April 2021 Resolved
Provide EPIRB registration and properly affix sticker.
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2021 Resolved
First aid kit missing ammonia inhalants and iodine applicators.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 5 May 2021
Resolution: Ammonia inhalants and iodine swabs are onbaord and added to the kit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 April 2021 Resolved
Renew painter on center life floats. Restricted to 114 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 April 2021 Resolved
Renew retro reflective material on center bottom 10 passenger lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 April 2021 Resolved
Portside FWD engine room bulkhead not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 April 2021 Resolved
Properly secure F/W pump motor in the tank room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 April 2021 Resolved
Properly secure hand rails and lighting fixtures in passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2021 Resolved
Firemain discharge piping is leaking and wasted at the joint IVO union.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021 Resolved
Properly clean battery terminals on port main engine and ssdg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2021 Resolved
Replace clamps on main engine upper exhaust injection point.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 22 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 April 2021 Resolved
Renew fuel hose on generator fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 April 2021 Resolved
Renew lighting fixture lens above generator.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2020 Resolved
Port main engine unable to start due to inoperable starter. Make effective repairs on port main engine starter and prove proper operation to the attending Marine Inspector. Vessel is restricted from carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Rebuilt starter was installed and tested in the presence of the attending Marine Inspector
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020 Resolved
Renew butt connectors on selector switch wire and starter solenoid wires.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Connectors for 3 wires were properly renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020 Resolved
Port MDE would not start while carrying passenger 39 miles offshore. Complete permantent repairs to port MDE prior to carring passengers. All repairs are to be conducted to the satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2020
Resolution: Rebuilt starter and starter solenoid installed tested by tech. REP and CG MIs, test SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 9 July 2020 Resolved
Crew did not have valid first aid cards onboard. Prove or provide 50% of crew with valid cards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2020
Resolved 9 July 2020
Resolution: Master provided documentation for four crewmembers, showing certification for first aid for crewmembers to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2020 Resolved
Remove the dead end wiring on port side of engine room marked by inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2020 Resolved
Stbd engine MDE lube oil pressure gauge is damaged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 9 July 2020 Resolved
Loover in port side passenger compartment in overhead is loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 9 July 2020 Resolved
The engine room hand rail was loose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2020 Resolved
Number of PFD's at stowage locations were missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 July 2020 Resolved
Conduct drills (man overboard & fire) and provide attestation to the office.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 July 2019 Resolved
Hydro is not properly marked on installation date.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2019
Resolved 28 August 2019
Resolution: Verified marking
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2019 Resolved
Fire servicing tags are not properly marked (no date of servicing)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 July 2019
Resolved 28 August 2019
Resolution: Verified servicing date
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 July 2019 Resolved
Mounting hardware is wasted and worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: new hardware installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2019 Resolved
Fire hoses and nozzles are worn and need replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: New hoses meet UL 19
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 July 2019 Resolved
The engine room light fixtures have damaged and or missing len covers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: New covers installed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 July 2019 Resolved
Provide repair plan for 2" facture on deck.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 September 2019
Resolution: M/I attended vessel and verified satisfactory this date. See narrative for detials.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 9 July 2019 Resolved
Remove the tint on aft windows in pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: Tint removed
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 July 2019 Resolved
Replace wood fire dampeners with aluminum.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: New aluminum dampners installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2019 Resolved
Remove or replace to boat wire the dead end electrical wires, corrosion on battery terminals, and excessive fluids.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: Drop cords removed, corrosion removed and battery trays clear of battery fluids.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2018 Resolved
12 life-jackets were found damaged and not servicable.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2018
Resolved 23 July 2018
Resolution: M/I attended and noted all damaged life-jackets had been corrected this date.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2018 Resolved
Replace engine room fire dampner found damaged this date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 July 2018 Resolved
Remove corrosion from pilothouse under operating station wiring connections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2018 Resolved
Remove excessive coolant from overflow container and mantain.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2018 Resolved
The steering post needs to be properly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 July 2018 Resolved
Port and Stbd head doors are missing properly working devices and hardware.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2018 Resolved
Clean and repair leak on hydraulic winch for anchor system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 March 2017 Resolved
Aft engine room bulkhead and overhead is wasted. Crop and renew with 18 x 18 insert crossing two frame spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 11 April 2018
Resolution: Completed during dry-dock 2018.
Engineering › Bilge Water Management System › Piping
Issued 30 March 2016 Resolved
An soft patch was discovered on the bilge piping leading from the engine room to the forward compartments. Approximately 16 inch section of the bilge piping (aluminum) was required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder replaced bilge piping in kind, inspected welds, all satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 March 2016 Resolved
The vessel's starboard main engine wet exhaust rubber hose was found in a deteriorated condition. The rubber hose is required to be replaced in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard replaced the rubber hose on the wet exhaust and secured the ends with two stainless steel clamps on each end attaching the hose to the exhaust pipe.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 March 2016 Resolved
The vessels starboard battery box was found deteriorated. The Battery box is required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Replaced battery box with an fiberglass lined box.
Engineering › Bilge Water Management System › Piping
Issued 18 March 2016 Resolved
One of the bilge gate valves located on the bilge manifold in the engine room was found seized. Repair or replace valve to render the valve operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard was able to repair the valve and it was exercised satisfactorily.
Fire Fighting › Fire Main › Material
Issued 18 March 2016 Resolved
Fire Main piping in the engine room was found with an pinhole leak. Approximately 12 inch section of the fire main is required to be replaced in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Fire Main piping was replaced.
Fire Fighting › Fire Main › Valves
Issued 18 March 2016 Resolved
The fire main stop valve was found inoperable and required repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard replaced fire main gate valve and reinstalled.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 March 2016 Resolved
In void #2 the watertight bulkhead at frame 11 was found wasted with an 1/2 inch diameter hole at the bottom of the bulkhead in way of the center vertical keel. Approximately a 26 inch x 18 inch insert to the bulkhead is required to be installed and completion of non-destructive testing shall be completed in the presence of an marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder installed an 26 inch x 18 inch insert with aluminum 5000 series plate. Welds were tested satisfactorily with an soap and air test.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 March 2016 Resolved
In void #2 fractured welds were discovered at starboard longitudinal #3, #4, & #5 in way of frame 11. Fractured welds were also discovered at the port longitudinal #4 in way of frame 11.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder gouged and re-welded fractured welds.
Construction/Loadline › Hull › Bracket
Issued 18 March 2016 Resolved
Three gussets in void #2 that attach the port transverse frames to the starboard transverse frames were found excessively deteriorated. Replace identified three gussets to original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Replaced three gassets, completed visual inspection of welds.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2016 Resolved
Portside transverse frames #5 and #6 in void #2 where found fractured. Replace framing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Transverse frames were cropped and renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2016 Resolved
Crop and renew starboard transverse frame #5 where welds are fractured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Crop and Renewed frame #5.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 March 2016 Resolved
Identified the overhead deck longitudinal framing at both the port and starboard #7 frames. Replace approximately 3ft section of each frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Replaced overhead framing members. Visually inspected welds.
Construction/Loadline › Hull › Weld
Issued 18 March 2016 Resolved
Identified fractured weld at the connection between the stanchion and the floor frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder gouged and rewelded.
Engineering › Steering Gear System › Linkage
Issued 16 March 2016 Resolved
Starboard rudder was found with significant movement. The ball joints connecting the jockey bar to the rudder stock was found to be worn and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 8 April 2016
Resolution: Shipyard replaced jockey bar, replaced bearings and steering system tested satisfactory.
Engineering › Bilge Water Management System › Piping
Issued 4 August 2015 Resolved
Crop/renew forepeak bilge pipe IWO engine room manifold due to leak in weld
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 5 August 2016
Resolution: FWD bilge pipe was renewed.
Engineering › Fuel Oil Service System › Hose
Issued 4 August 2015 Resolved
Renew stbd MDE hose (outer jacket wasted)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 16 September 2015
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 4 August 2015 Resolved
Provide circuit breaker card to corresponding numbered breakers w/ amperages (engine room)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 16 September 2015
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 August 2015 Resolved
Update navigation publications for area of operation (Light List, Tide/Current Tables, U.S. Coast Pilots)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 16 September 2015
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 4 August 2015 Resolved
Stencil vsl name on port/stbd ring buoys
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 16 September 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 August 2015 Resolved
Renew expired items IWO first aid kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 16 September 2015
Electrical › Electrical Distribution System (service) › Conductor
Issued 19 August 2014 Resolved
Hardwire power supply IWO E/R cameras. Extension cords are currently fitted.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 14 October 2014
Lifesaving › Lifebuoys › Serviceable
Issued 19 August 2014 Resolved
New ring buoy on upper deck due to degradation.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 7 April 2015
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 19 August 2014 Resolved
Mount bell bracket IWO aft pilothouse.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 14 October 2014
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 August 2014 Resolved
Lengthen waterlight lines and clean out waterlight lenses due to contamination.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 14 October 2014
Fire Fighting › Fire Main › Pressure
Issued 19 August 2014 Resolved
Relocate fire pump gauge in discharge piping. Currently mounted in pump volute.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 14 October 2014
Lifesaving › Lifefloat › Markings
Issued 19 August 2014 Resolved
Paint life-floats international orange. Lifefloats are red.
Action required: 705 - Other - as specified
Due 19 September 2014
Resolved 5 August 2016
Resolution: Lifefloats are correct color and condition for service.
Communications › Radio Communications › EPIRB
Issued 19 August 2014 Resolved
Service EPIRB battery by 31AUG14.
Action required: 705 - Other - as specified
Due 31 August 2014
Resolved 14 October 2014
Engineering › Bilge Water Management System › Piping
Issued 25 March 2014 Resolved
Attending inspectors noted wasted union IWO Forepeak bilge suction valve.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 4 April 2014
Resolution: Attending inspectors verified installation of new union IWO Forepeak bilge suction valve.
Construction/Loadline › Hull › Bracket
Issued 25 March 2014 Resolved
Attending inspectors noted fractured weldments IWO Forepeak (x10), fractured strenght plate IWO FR #2, & fractured weldment IWO FR #1 (lower)
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 31 March 2014
Resolution: Attending inspectors verified repairs made to weldments IWO Forepeak.
Construction/Loadline › Hull › Longitudinal Frame
Issued 25 March 2014 Resolved
Attending inspectors noted fractured bottom longitudinal IWO Void #2 (rodroom) (first longitudinal outboard CVK @ bulkhead)
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 4 April 2014
Resolution: Attending inspectors witnessed installation of bottom longitundal.
Construction/Loadline › Hull › Transverse Frame
Issued 25 March 2014 Resolved
Attending inspectors noted fractured transverse frame (#2) IWO Void #2 (rod room).
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 4 April 2014
Resolution: Attending inspectors verified installation of new transverse frame IWO FR#2, Void #2 (rod room).
Construction/Loadline › Hull › Bracket
Issued 25 March 2014 Resolved
Attending inspectors noted fractured bracket/strength plate IWO FR#2, Void #2 (rod room).
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 4 April 2014
Resolution: Attending inspectors verified repairs made to bracket/strenght plate IWO FR#2, Void #2 (rod room).
Construction/Loadline › Hull › Weld
Issued 25 March 2014 Resolved
Attending inspectors noted fractured weldments IWO Void #2 (rod room) throughout space in addition to fractured weldments IWO deck support stanchions (port & starboard).
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 31 March 2014
Resolution: Attending inspectors verified repairs made to fractured weldments (pick up''s) and deck stanchions IWO Void #2.
Construction/Loadline › Hull › Keel
Issued 25 March 2014 Resolved
Attending inspectors noted fractures IWO vessels keel approx. 1.5' fwd of dry dock plugs.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 4 April 2014
Resolution: Attending inspectors verified repairs made to vessels fractured keel. NDT was performed IAW ABS Rules for NDT.
Engineering › Fuel Oil Service System › Piping
Issued 25 March 2014 Resolved
Attending inspectors noted wasted fuel piping IWO port E/R.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 2 April 2014
Resolution: Attending inspectors verified repairs made to vessels fuel piping system IWO port E/R.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 March 2014 Resolved
Attending inspectors noted severe pitting IWO lower portion of fwd lazarette bulkhead, port side.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 2 April 2014
Resolution: Attending inspectors verified repairs made to fwd lazarette bulkhead, portside. Repairs were verified IAW ABS Rules for NDT.
Construction/Loadline › Hull › Bracket
Issued 25 March 2014 Resolved
Attending inspectors noted three (03) severely wasted strength plates/brackets IWO lazarette @ CVK.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 2 April 2014
Resolution: Attending inspectors verified repairs made to strenght plates/brackets IWO lazarette.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 25 March 2014 Resolved
Attending inspectors noted pitting IWO SSDG exhaust piping @ flex coupling (lazarette).
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 31 March 2014
Resolution: Attending inspector verified condition of exhaust piping (metallic) IWO flex coupling.
Construction/Loadline › Structures › Machinery Space Opening
Issued 25 March 2014 Resolved
Attending inspector noted fractures to top of ladder IWO lazarette.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 2 April 2014
Resolution: Attending inspector verified repairs made to ladder IWO lazarette.
Construction/Loadline › Hull › Stiffener
Issued 25 March 2014 Resolved
Attending inspectors noted mising deck support structure IWO lazarette.
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 2 April 2014
Resolution: Attending inspectors verified instllation and repair of deck support structure IWO lazarette.
Construction/Loadline › Hull › Keel
Issued 25 March 2014 Resolved
Attending inspectors noted minor damage IWO fwd keel (port & stbd).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 April 2014
Resolved 2 April 2014
Resolution: Attending inspectors verified repairs made to vessels keel.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 25 January 2011 Resolved
Certificate of Documentation needs to have Coastwise and fishery endorsement on it.
Action required: 705 - Other - as specified
Due 21 February 2011
Resolved 21 February 2011
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 January 2011 Resolved
Replace Retro-tape on several life jackets
Action required: 705 - Other - as specified
Due 21 February 2011
Resolved 21 February 2011
Stability › Watertight Integrity › General
Issued 25 January 2011 Resolved
Float balls in deck vents need to be replaced
Action required: 705 - Other - as specified
Due 21 February 2011
Resolved 21 February 2011
Fire Fighting › Fire Main › Pressure
Issued 25 January 2011 Resolved
Install pressure guage IWO fire pump discharge.
Action required: 705 - Other - as specified
Due 21 March 2011
Resolved 13 June 2012
Engineering › Bilge Water Management System › Manifold
Issued 25 January 2011 Resolved
Renew soft patched piping IWO bilge /washdown system.
Action required: 705 - Other - as specified
Due 21 March 2011
Resolved 15 November 2011
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 January 2011 Resolved
Renew wasted/pinholed R/W cooling piping IWO generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2011
Resolved 15 November 2011
Fire Fighting › Fire Pumps › Pressure
Issued 28 January 2010 Resolved
Fire Pump was seized. Prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 January 2010
Resolved 28 January 2010
Resolution: Proper operation was witnessed by a CG Marine Inspector.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 January 2009 Resolved
Replace/renew all retro on life rings
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 January 2009 Resolved
Replace/renew batteries in Life Float lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Lifesaving › Lifefloat › Painter
Issued 13 January 2009 Resolved
Renew painter line on port life float line
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Navigation › Piloting/Steering › Marine Charts
Issued 13 January 2009 Resolved
Provide updated paper charts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 January 2009 Resolved
Provide update correction of light list and coast pilot for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Construction/Loadline › Structures › Scuttle
Issued 13 January 2009 Resolved
Repair/replace fwd hatch- 18 freeman hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Construction/Loadline › Structures › Scuttle
Issued 13 January 2009 Resolved
Repair/replace gasket around steering hatch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 13 January 2009 Resolved
Repair/replace 3 adult lifejacket (failed for retro).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 January 2009 Resolved
Label all life jacket storage locations 2 inches minimum.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 13 January 2009 Resolved
Paint draft marks in contrasting color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 2 April 2009
Engineering › Fuel Oil Service System › Piping
Issued 13 January 2009 Resolved
Repair/replace generator fuel return line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 January 2009 Resolved
Conduct fire and man overboard drills underway. Unable to conduct drills due to weather.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 26 January 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 November 2007 Resolved
Replace expired medicines in First Aid Kit.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 10 January 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 6 November 2007 Resolved
Replace outdated CG Light List and Coast Pilot.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2007
Resolution: Replaced
Electrical › Lighting (service) › Lighting Fixture
Issued 6 November 2007 Resolved
Replace fixture cover on Fwd Port side main deck.
Action required: 705 - Other - as specified
Due 30 January 2008
Resolved 26 January 2009
Engineering › Steering Gear System › Yoke
Issued 6 November 2007 Resolved
Complete repairs to steering system and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2007
Engineering › Bilge Water Management System › Interface Detector
Issued 6 November 2007 Resolved
Repair/replace bilge pump wiring in aft steering compartment.
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Bracket
Issued 6 November 2007 Resolved
Repair weld fracture in vee at frame #3 in fwd peak tank.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 10 January 2008
Deck/Cargo › Mooring/Anchoring › Winch
Issued 6 November 2007 Resolved
Repair hydraulic leak in anchor windlass.
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Bracket
Issued 6 November 2007 Resolved
Repair fracture in frame #5 Stbd side of vee IWO bracket.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 November 2007 Resolved
Repair fractures in frame #5 port and starboard IWO floor frame bracket and shelf floor longs.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Bracket
Issued 6 November 2007 Resolved
Repair fracture in frame #6 vee IWO deck support bracket.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 November 2007 Resolved
Repair fracture in frame #6 port and stbd outboard.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Bracket
Issued 6 November 2007 Resolved
Repair fracture to frame #7 port and stbd sides of vee.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 10 January 2008
Construction/Loadline › Hull › Hull Plating
Issued 6 November 2007 Resolved
Repair fractures at frame #7 port and stbd side deck support in overhead.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 10 January 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 6 November 2007 Resolved
Repair fractures at frames #8, 9, 13 & 14, port and stbd side of vee.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Construction/Loadline › Hull › Transverse Frame
Issued 6 November 2007 Resolved
Repair fracture to frame #14 IWO deck support in floorlong.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 10 January 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 6 November 2007 Resolved
Repair leak in oil guage line to bridge.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 6 November 2007 Resolved
Replace holed MSD piping stbd side from bulkhead.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Resolution: Replaced with PVC pipe and did not install metallic shutoff valve at bulkhead penetrations IAW 46CFR182.720. Considered to be temporary repair.
Engineering › Freshwater Generation System › Piping
Issued 6 November 2007 Resolved
Replace holed washdown piping stbd side.
Action required: 705 - Other - as specified
Due 6 December 2007
Resolved 9 November 2007
Engineering › Bilge Water Management System › Not Operational
Issued 6 November 2007 Resolved
Remount engine room high bilge level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 November 2007
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 November 2005 Resolved
Many lifejackets need new retroreflective tape. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 November 2005
Resolution: New retro-tape was applied and new lifejackets were purchased.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 November 2005 Resolved
Vessel required to post lifejacket donning placard in a conspicuous place. 46 CFR 185.516
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 November 2005
Resolution: Vessel has posted lifejacket donning placard.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 10 November 2005 Resolved
Vessel markings for lifejacket storage locations was worn and faded. Vessel required to clearly mark storage location of lifejackets. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 November 2005
Resolution: Lifejacket storage locations are clearly marked.
Lifesaving › Hand Flares › Storage
Issued 10 November 2005 Resolved
Container for flares must be marked IAW 46 CFR 185.614.
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 November 2005
Resolution: Container for flares is clearly marked.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 November 2005 Resolved
Vessel is required to have an emergency broadcast placard posted IAW 46 CFR 184.506.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 November 2005
Resolution: Vessel posted emergency broadcast placard in the operating station.
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 November 2005 Resolved
Lifefloat retroreflective tape needs to be renewed. Lifefloats must be separated by spacers IAW 46 CFR 180.137(f).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 19 December 2005
Resolution: Lifefloat retro tape was renewed and spacers are now in place.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 November 2005 Resolved
Retroreflective tape on ring life buoys needs to be renewed. 46 CFR 185.604(i)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2005
Resolved 16 November 2005
Resolution: Tape renewed on ing life buoys
Engineering › Feedwater/Condensate Water System › Piping
Issued 10 November 2005 Resolved
Crack in overboard pipe in starboard aft engine room space.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 19 December 2005
Resolution: Overboard pipe was cropped and renewed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 November 2005 Resolved
Guards missing on main engine belts. 46 CFR 177.960.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 19 December 2005
Resolution: Guards are now in place.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 10 November 2005 Resolved
Fire pump needs new seal/packing. 46 CFR 181.300.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2005
Resolved 19 December 2005
Resolution: New packing was added to fire pump.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 10 November 2005 Resolved
Bracket for hydraulic winch was broken and hose leaks oil. 46 CFR 184.300.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2005
Resolved 19 December 2005
Resolution: Bracket was repaired and hydraulic pump will be changed out to address leaks.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 10 November 2005 Resolved
A/C overboard pipe needs a valve and a check valve. 46 CFR 182.720.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2005
Resolved 19 December 2005
Resolution: A/C overboard pipe was fitted with check valve and ball valve.
Stability › Watertight Integrity › General
Issued 10 November 2005 Resolved
Bulkhead fittings below main deck need to be watertight. 46 CFR 179.320(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 December 2005
Resolved 19 December 2005
Resolution: Bulkhead fittings were inspected and are now watertight..
Lifesaving
Issued 6 November 1996 Resolved
VESSEL IS RESTRICTED TO CARRYING NOT MORE THAN 96 TOTAL PERSONS ON BOARD DURING "OCEANS" VOYAGES UNTIL THE STBD UPPER LIFEFLOAT IS PROPERLY REPAIREDOR REPLACED.
Condition: Unknown
Due 6 November 1996
Resolved 6 November 1996
Lifesaving
Issued 8 November 1995 Resolved
PRIOR TO OPERATING WITH PASSENGERS, STENCIL 22 PERSON LIFE FLOAT WITH MAXIMUM NUMBER OF ALLOWABLE PERSONS.
Condition: Unknown
Due 9 November 1995
Resolved 16 November 1995
Construction/Loadline
Issued 8 November 1995 Resolved
PROVIDE HULL MARKINGS IN ACCORDANCE WITH 46 CFR PART 185.30-3.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Engineering
Issued 8 November 1995 Resolved
REPLACE/CLEAN FLAME SCREEN ON PORT SIDE FUEL VENT.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Construction/Loadline
Issued 8 November 1995 Resolved
REPAIR/REPLACE WASTED AREA OF BULKHEAD LOCATED IN AFTER STEERING COMPARTMENT (LOWER SECTION, MIDSHIP) IN WAY OF EXISTING TEMP REPAIR. TO BECOMPLETED AT VESSEL'S NEXT DRYDOCK EXAM BUT NLT 01JAN96.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Lifesaving
Issued 8 November 1995 Resolved
PROVIDE PADDLE FOR 22 PERSON LIFE FLOAT, WHERE MISSING, PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 9 November 1995
Resolved 16 November 1995
Engineering
Issued 8 November 1995 Resolved
LABEL EMERGENCY FUEL OIL SHUT-OFF PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 9 November 1995
Resolved 16 November 1995
Construction/Loadline
Issued 8 November 1995 Resolved
INSTALL KEEPER CHAINS TO ALL WATERTIGHT HATCHES.
Condition: Unknown
Due 9 November 1995
Resolved 16 November 1995
Engineering
Issued 29 March 1995 Resolved
REPAIR WATER LEAK IN STARBOARD MDE MUFFLER.
Condition: Unknown
Due 29 March 1995
Resolved 30 March 1995
Construction/Loadline
Issued 29 March 1995 Resolved
CLEAN TO BARE METAL AN PRESERVE PITS IN THE LOWER PORTION OF THE FWD STEERING SPACE BULKHEAD.
Condition: Unknown
Due 8 April 1995
Resolved 30 March 1995
Navigation
Issued 29 March 1995 Resolved
CORRECT LOOSE STEERING SYSTEM CROSS-LINK PINS.
Condition: Unknown
Due 8 April 1995
Resolved 30 March 1995
Navigation
Issued 29 March 1995 Resolved
GRIND AND DRILL AND WELD AREAS OF CREVICE CORROSION IN BOTH RUDDER SHAFTS.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Navigation
Issued 29 March 1995 Resolved
LOCATE AND CORRECT LEAK IN STEERING RAM.
Condition: Unknown
Due 8 April 1995
Resolved 30 March 1995
Lifesaving
Issued 16 November 1994 Resolved
PROVIDE 3 PADDLES FOR LIFEFLOATS PRIOR TO VESSELS OPERATION.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Lifesaving
Issued 16 November 1994 Resolved
REPAIR OR REMOVE HOT WATER HEATER.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Construction/Loadline
Issued 16 November 1994 Resolved
REPAIR CRACKED WELD ON DECK STANCHION, FORWARD PORT SIDE, NUMBER 2 VOID.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Lifesaving
Issued 16 November 1994 Resolved
LOCATE AND REPAIR HYDRAULIC LEAK IN FORE PEAK.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Electrical
Issued 16 November 1994 Resolved
REMOVE WIRE NUTS FROM A/C PUMP CONNECTION IN NUMBER 2 VOID.
Condition: Unknown
Due 16 November 1994
Resolved 16 November 1994
Fire Fighting
Issued 16 November 1994 Resolved
PROVIDE SUCTION HOSE FOR THE HAND FIRE PUMP TO REACH FROM THE MAIN DECK TO THE WATER PRIOR TO VESSELS OPERATION.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Construction/Loadline
Issued 23 November 1993 Resolved
REWELD FRACTURES TO BOTTOM LONGS IN NUMBER 1 & 2 VOIDS AT ADJOINING BULKHEAD.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Lifesaving
Issued 23 November 1993 Resolved
PROVIDE 17 ADULT AND 1 CHILDS PFD'S. TOTAL PERSONS ALLOWED REDUCED TO 137 UNTIL PROVIDED.
Condition: Unknown
Due 23 November 1993
Resolved 23 November 1993
Construction/Loadline
Issued 6 January 1993 Resolved
MAKE PERMANENT REPAIRS TO THE FRACTURES IN #1 AND #2 VOIDS AS DISCUSSED WITH MASTER.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Navigation
Issued 6 January 1993 Resolved
MAKE OPERABLE SECOND MARINE RADIO._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1993
Resolved 7 January 1993
Lifesaving
Issued 6 January 1993 Resolved
PROVIDE A SUITABLE RESCUE PLATFORM.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Lifesaving
Issued 6 January 1993 Resolved
PROVIDE ONE RING BUOY.
Condition: Unknown
Due 6 January 1993
Resolved 6 January 1993
Construction/Loadline
Issued 2 October 1991 Resolved
MAKE PERMANENT REPAIRS TO WELD FRACTURES IN TWO FWD COMPARTMENTS ALL AS DISCUSSED WITH OWNER.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Construction/Loadline
Issued 4 January 1990 Resolved
REWELD CRACKED WELDS IN THE #2 FRAME AT THE DECK CONNECTION IN THE WATER TANK VOID SPACE, BOTH SIDES.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990 Resolved
REWELD CRACKED WELD AT THE TOP OF THE STARBOARD STANCHION IN THE FORWARD VOID.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Construction/Loadline
Issued 4 January 1990 Resolved
REWELD CRACKED WELD IN WAY OF #2 FRAME AND #1 BOTTOM LONG IN THE WATER TANK VOID SPACE, STARBOARD SIDE.
Condition: Unknown
Due 4 January 1990
Resolved 4 January 1990
Electrical
Issued 5 August 1987 Resolved
COVER OPENING IN CIRCUIT BREAKER PANEL WITH SUITABLE BLANKING PLATE.
Condition: Unknown
Due 5 August 1987
Resolved 5 August 1987
Electrical
Issued 5 August 1987 Resolved
REMOVE QUARTZ TYPE LIGHT FIXTURES.
Condition: Unknown
Due 5 August 1987
Resolved 5 August 1987

Casualty record · 7

20 December 2005Routine · role: Involved in a Marine Casualty · activity 2555733
11 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6710822
30 August 2019Routine · role: Involved in a Marine Casualty · activity 6850145
13 August 2020Routine · role: Involved in a Marine Casualty · activity 7049419
24 September 2020Routine · role: Involved in a Marine Casualty · activity 7069499
28 August 2021Routine · role: Involved in a Marine Casualty · activity 7307204
2 June 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7600514
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CAROLINA PRINCESS (2005–2022). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record