MAURY USCG vessel records
← All vessels

SOUND BOUND ODYSSEY

SOUND BOUND ODYSSEY is a 1986 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2016, most recently in April 2026, along with 96 deficiencies and 7 casualty investigations between 2005 and 2022.

Records from 2005 to 2026. Most recent: inspection, 13 April 2026.

Built
1986
Last inspected
13 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 April 2026
…with no type recorded6
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ9374
272822
Flag
UNITED STATES
Maury page id
psix-272822

Documentation record

Registered dimensions (L × B × D)76.7 ft × 24.1 ft × 8.7 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT, INC · PATTERSON, LA, UNITED STATES · built 1986
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 18 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

USS CARTER HALL (LSD 50) Public Vessel, Unclassified · MISLE 608057 · 2 June 2022 · activity 7600514

Inspection history · 35

13 April 2026 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8347195
21 November 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8272310
21 October 2025 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8256164
10 June 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8156220
25 October 2024 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8024537
24 September 2024 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8008289
23 May 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7915430
2 January 2024 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7844186
8 October 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7806895
23 May 2023 Annual Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7688881
21 December 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7611646
16 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7560178
2 June 2022 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7600514
12 April 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7421906
18 February 2022 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7398096
18 October 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7334656
28 August 2021 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7300083
28 August 2021 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7307204
24 June 2021 In-Service Inspection · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7234400
21 April 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7155148
24 September 2020 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7064397
24 September 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7069499
13 August 2020 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7049419
11 August 2020 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7030769
9 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6999832
23 January 2020 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6894452
30 August 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6850145
9 July 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6744301
12 June 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6712141
11 June 2019 Type not recorded
No type recorded · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6710822
19 July 2018 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6489092
12 March 2018 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6367878
11 March 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6097612
4 August 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5961879
14 March 2016 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5832536

Deficiency record · 96

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 April 2026 Resolved
Stations must have an authorization granted by the FCC. Vessel did not have station license or Bridge-to-Bridge Cert on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: FCC station license and Bridge-to-Bridge certs issued and onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 April 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers for life jackets. Letters and numbers must be at least (2 inches) high. Child life Jacket stowage was not labeled.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Child life jacket stowage labeled correctly.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 13 April 2026 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers for life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Number of child life jacket labeled on Storage.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 April 2026 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguishers brackets not mounted.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: All fire extinguisher mounts installed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 April 2026 Resolved
Vessel did not have a logbook on board to document drills or tests. Get Logbook.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Log book onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 April 2026 Resolved
Protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to the satisfaction of the cognizant [name withheld] shafts on Main Engines were exposed and open. May case crew injury.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 11 May 2026
Resolution: Protective guards installed above both main engine shafts.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 10 June 2025 Resolved
A vessel on Oceans, coastwise or limited coastwise must carry 6 hand red flares and 6 orange smoke signals for a total of 12. You can substituted red for orange, so you can have all red. Vessel only had 9 flares on board. Must replace the 3 missing flares for a total of 12.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: 03 missing flares have been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 10 June 2025 Resolved
FCC Safety Certificate expired May 25th 2025. Must renew FCC Safety Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: Updated FCC safety certifcate available and reviewed during inspection, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 10 June 2025 Resolved
Signage on aft ladder for passenger count on upper deck was broken and missing total passenger count. Replace broken signage to show max passenger count allowed on upper deck in accordance with stability letter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2025
Resolved 21 July 2025
Resolution: Signage updated to show number of passengers permitted on upper deck. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Insulation wetted through (oil)
Issued 25 October 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices,fire hazards,and other hazardous situations must be corrected. Oil soaked lagging found on STBD inboard main engine turbocharger. Remove lagging and repair oil leaks. Install new lagging and make available to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 November 2024
Resolution: Lagging has been cleaned. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Discovered multiple excessive oil leaks on both propulsion engines that present potential fire hazard. Correct oil leaks on both engines and perform sea trials to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 November 2024
Resolution: Excessive oil leaks have been addressed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 25 October 2024 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard. Excessive accumulation of oil was discovered in E/R bilges. Remove oil/debris from E/R bilges and clean to the satisfaction of the attending M/I.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 November 2024
Resolution: ER has been properly cleaned. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Renew broken alternator belt for port main engine. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 November 2024
Resolution: Crew installed new belt. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to:(b) Protect passengers, crew, other persons, and the vessel from electrical hazards and electrical shock. Electrical panel in engine room presents electrical hazards due to missing breaker. Install a blank over spare breaker opening.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew installed blanks on electrical panel. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards and electrical shock. Electrical panel in galley is missing latch. Install new closing latch to breaker panel door.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew installed closing/locking device on panel door. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2024 Resolved
This part contains requirements for the installation, and operation of electrical equipment and systems. Remove dead ended wires in way of both propulsion engines.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew removed dead end wires. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 October 2024 Resolved
Auxiliary machinery of the internal combustion piston type must comply with the provisions of this part. Generator has excessive jacket water leak. Make repairs and perform sea trials to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: J/W leak was addressed on SSDG. All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 October 2024 Resolved
The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. No. 1 void hatch hinge is cracked. Replace with in kind equipment and make available for attending MI.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew replaced hinge on void access door. All SAT.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 25 October 2024 Resolved
A vessel is inspected for compliance with the standards required by this sub chapter. Machinery, equipment, materials, and arrangements not covered by standards in this sub chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Approximately 38 gallons of bleach found in No. 2 void not properly secured. Move containers to another place preferable weather deck or locker to avoid potential chemical spill.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew removed bleach from space. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 October 2024 Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil and fluid power systems, subject to the following requirements: Flexible hose runs must be visible, easily accessible, protected from mechanical damage. L/O cooler flex hose is pinched on L/O filter housing. Adjust hose away from filter housing and replace hose if needed with in kind equipment. Make available for attending MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2024
Resolved 8 November 2024
Resolution: Crew replaced hose and readjusted angle.Crew installed shaffing gear on new hose. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2024 Resolved
For a life float—Approved under approval series 160.027 or other standard specified by the Commandant. Buoyant apparatus may be used to meet requirements for life floats if the buoyant apparatus was installed on board the vessel on or before March 11, 1996, and if the buoyant apparatus remains in good and serviceable condition. All five (05) life floats have meet their service life. Replace with in-kind equipment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024 Resolved
The requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) of this chapter. STBD main engine has a significant oil leak coming from F/W pump. Repair and provide finding to attending MI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 May 2024 Resolved
The requirements for machinery and boilers for steam and electrically propelled vessels are contained in applicable regulations in subchapter F (Marine Engineering) of this chapter. Outboard STBD main engine has a pinched jacket water house near thermostat. Repair and provide finding to attended MI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 May 2024 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Both Port and STBD main engines need guard over rotating machinery (belts) tighten.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2024
Resolved 26 June 2024
Resolution: Received photo evidence. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 January 2024 Resolved
The construction of a vessel must allow the safe operations of the vessel giving consideration to provisions for a seaworthy hull. Fore peak: Identified 12" crack at #3 center joining frame. Make effective repair IAW proposed repair plan.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 January 2024
Resolution: MI's visually inspected completed repairs. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 January 2024 Resolved
The construction of a vessel must allow the safe operations of the vessel giving consideration to provisions for a seaworthy hull. Fore peak: Identified 6" crack on weld IVO #2 port-side frame. Gouge out and re-weld.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 January 2024
Resolution: MI's visually inspected completed repairs. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 2 January 2024 Resolved
A marine sanitation device must be designed to prevent the overboard discharge. Expansion tank for MSD was found wasted. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2024
Resolved 23 May 2024
Resolution: Vessel crew replaced tank with in-kind equipment. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 2 January 2024 Resolved
At every other inspection unsafe practices and other hazardous situations must be corrected. Port-side forward window in accommodation space was loose and not properly sealed. Make proper repairs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 February 2024
Resolved 23 May 2024
Resolution: MI verified new gasket was installed around window. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 July 2023 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. Newly appointed crew member was not familiar with fire drills.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 5 July 2023
Resolution: Crew conducted drills with new crewmember
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 July 2023 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 02 main deck life ring buoys found discolored and severally weathered. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: MI witnessed new ring buoys. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 5 July 2023 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following: Inspection of piping to determine that the system is in operating condition. Piping elbow found clad welded. Make proper repairs.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: MI's witnessed proper repairs on fire main system. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 May 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. CO2 bottles in passenger comp and engine room were installed after 2016 and dont meet UL 2-A or 40 B:C. Install proper extinguishers in the passenger compartment in engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2023
Resolved 19 July 2023
Resolution: MI's witnessed new proper extinguishers. All SAT.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 April 2022 Resolved
All vessels must have nav lights that are in compliance with the applicable sections of the nav rules. Port running light is inoperable. Prove to MI that light is operational.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2022
Resolved 14 April 2022
Resolution: Operator proved port running light is operational. All SAT
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 12 April 2022 Resolved
An EAP training program must be conducted for the employers supervisor. Captain needs EAP training. Provide proof to MIs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 14 April 2022
Resolution: Captain provided proof that training was conducted. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2022 Resolved
Fill pipes must be suitably marked for identification. Fill location(s) on vessel must be marked.
Action required: 705 - Other - as specified
Due 19 April 2022
Resolved 14 April 2022
Resolution: Vessel clearly marked diesel fill pipes throughout. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 April 2022 Resolved
Each battery must be secured to protect shifting with the roll and pitch of vessel. Spare battery was not secure. Secure battery.
Action required: 705 - Other - as specified
Due 19 April 2022
Resolved 14 April 2022
Resolution: Spare battery was secured in battery box with proper cover, all SAT.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 April 2022 Resolved
A vessel must comply with the applicable requirements issued by the FCC. VHF radio is not integrated with GPS. Prove radio has GPS to attending inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2022
Resolved 14 April 2022
Resolution: Vessel proved DSC fuction of the radio and provided a self-test by using MMSI number. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 18 February 2022 Resolved
The construction of a vessel must allow the safe operations of the vessel giving consideration to provisions for a seaworthy hull. Rod room: Crack in overhead port side aft as marked.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 2 March 2022
Resolution: Weld gouged out and re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 August 2021 Resolved
Repairs or alterations to the hull, machinery or equipment that affect the safety of the vessel must not be made without approval of the cognizant [name withheld] master reported a reduction of propulsion on the port main engine, while operating with passengers this date. Trouble shoot, make proper repairs and provide tech report with findings to the satisfaction of the Coast Guard. Prior to passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 August 2021
Resolved 2 September 2021
Resolution: Aft blower, shaft, and chain replaced to the satisfaction of the attending inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 24 June 2021 Resolved
Master reported small leak on air conditioning thru hull fitting. Make proper repairs to the satisfaction of USCG
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2021
Resolution: New section of pipe installed and welded. NDT using dye pen and witnessed; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 24 June 2021 Resolved
Master reported #2 MDE #2 cylinder dropped two valves. Determine cause inspect for damage (further). Make proper repairs, conduct operation test to the satisfaction of the attending Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2021
Resolution: Repairs made to the #2 MDE and conducted underway sea trials.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 21 April 2021 Resolved
Properly post COI under glass.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 April 2021 Resolved
Properly post the stability letter.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 April 2021 Resolved
Provide EPIRB registration and properly affix sticker.
Action required: 705 - Other - as specified
Due 28 April 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2021 Resolved
First aid kit missing ammonia inhalants and iodine applicators.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 5 May 2021
Resolution: Ammonia inhalants and iodine swabs are onbaord and added to the kit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 April 2021 Resolved
Renew painter on center life floats. Restricted to 114 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 21 April 2021 Resolved
Renew retro reflective material on center bottom 10 passenger lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 April 2021 Resolved
Portside FWD engine room bulkhead not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 April 2021 Resolved
Properly secure F/W pump motor in the tank room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 April 2021 Resolved
Properly secure hand rails and lighting fixtures in passenger compartment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 April 2021 Resolved
Firemain discharge piping is leaking and wasted at the joint IVO union.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021 Resolved
Properly clean battery terminals on port main engine and ssdg.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 27 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 April 2021 Resolved
Replace clamps on main engine upper exhaust injection point.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 22 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 April 2021 Resolved
Renew fuel hose on generator fuel filter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 21 April 2021 Resolved
Renew lighting fixture lens above generator.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 28 April 2021
Resolution: Reviewed objective evidence to clear the deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2020 Resolved
Port main engine unable to start due to inoperable starter. Make effective repairs on port main engine starter and prove proper operation to the attending Marine Inspector. Vessel is restricted from carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Rebuilt starter was installed and tested in the presence of the attending Marine Inspector
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020 Resolved
Renew butt connectors on selector switch wire and starter solenoid wires.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2020
Resolution: Connectors for 3 wires were properly renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 August 2020 Resolved
Port MDE would not start while carrying passenger 39 miles offshore. Complete permantent repairs to port MDE prior to carring passengers. All repairs are to be conducted to the satisfaction of attending MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2020
Resolution: Rebuilt starter and starter solenoid installed tested by tech. REP and CG MIs, test SAT.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 9 July 2020 Resolved
Crew did not have valid first aid cards onboard. Prove or provide 50% of crew with valid cards.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2020
Resolved 9 July 2020
Resolution: Master provided documentation for four crewmembers, showing certification for first aid for crewmembers to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2020 Resolved
Remove the dead end wiring on port side of engine room marked by inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2020 Resolved
Stbd engine MDE lube oil pressure gauge is damaged.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 9 July 2020 Resolved
Loover in port side passenger compartment in overhead is loose.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 9 July 2020 Resolved
The engine room hand rail was loose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2020 Resolved
Number of PFD's at stowage locations were missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 July 2020 Resolved
Conduct drills (man overboard & fire) and provide attestation to the office.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2020
Resolved 21 July 2020
Resolution: The deficiency was rectified to the satisfaction of the marine inspector.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 July 2019 Resolved
Hydro is not properly marked on installation date.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 July 2019
Resolved 28 August 2019
Resolution: Verified marking
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2019 Resolved
Fire servicing tags are not properly marked (no date of servicing)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 July 2019
Resolved 28 August 2019
Resolution: Verified servicing date
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 July 2019 Resolved
Mounting hardware is wasted and worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: new hardware installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 July 2019 Resolved
Fire hoses and nozzles are worn and need replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: New hoses meet UL 19
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 July 2019 Resolved
The engine room light fixtures have damaged and or missing len covers.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: New covers installed
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 9 July 2019 Resolved
Provide repair plan for 2" facture on deck.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 11 September 2019
Resolution: M/I attended vessel and verified satisfactory this date. See narrative for detials.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 9 July 2019 Resolved
Remove the tint on aft windows in pilothouse.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: Tint removed
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 July 2019 Resolved
Replace wood fire dampeners with aluminum.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: New aluminum dampners installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 July 2019 Resolved
Remove or replace to boat wire the dead end electrical wires, corrosion on battery terminals, and excessive fluids.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2019
Resolved 28 August 2019
Resolution: Drop cords removed, corrosion removed and battery trays clear of battery fluids.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2018 Resolved
12 life-jackets were found damaged and not servicable.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2018
Resolved 23 July 2018
Resolution: M/I attended and noted all damaged life-jackets had been corrected this date.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 July 2018 Resolved
Replace engine room fire dampner found damaged this date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 July 2018 Resolved
Remove corrosion from pilothouse under operating station wiring connections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2018 Resolved
Remove excessive coolant from overflow container and mantain.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2018 Resolved
The steering post needs to be properly mounted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 July 2018 Resolved
Port and Stbd head doors are missing properly working devices and hardware.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2018 Resolved
Clean and repair leak on hydraulic winch for anchor system.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 4 September 2018
Resolution: Received, reviewed, and accepted documentation from o/o satisfying the requirement.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 March 2017 Resolved
Aft engine room bulkhead and overhead is wasted. Crop and renew with 18 x 18 insert crossing two frame spaces.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2017
Resolved 11 April 2018
Resolution: Completed during dry-dock 2018.
Engineering › Bilge Water Management System › Piping
Issued 30 March 2016 Resolved
An soft patch was discovered on the bilge piping leading from the engine room to the forward compartments. Approximately 16 inch section of the bilge piping (aluminum) was required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder replaced bilge piping in kind, inspected welds, all satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 March 2016 Resolved
The vessel's starboard main engine wet exhaust rubber hose was found in a deteriorated condition. The rubber hose is required to be replaced in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard replaced the rubber hose on the wet exhaust and secured the ends with two stainless steel clamps on each end attaching the hose to the exhaust pipe.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 March 2016 Resolved
The vessels starboard battery box was found deteriorated. The Battery box is required to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Replaced battery box with an fiberglass lined box.
Engineering › Bilge Water Management System › Piping
Issued 18 March 2016 Resolved
One of the bilge gate valves located on the bilge manifold in the engine room was found seized. Repair or replace valve to render the valve operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard was able to repair the valve and it was exercised satisfactorily.
Fire Fighting › Fire Main › Material
Issued 18 March 2016 Resolved
Fire Main piping in the engine room was found with an pinhole leak. Approximately 12 inch section of the fire main is required to be replaced in kind.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Fire Main piping was replaced.
Fire Fighting › Fire Main › Valves
Issued 18 March 2016 Resolved
The fire main stop valve was found inoperable and required repair or replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard replaced fire main gate valve and reinstalled.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 March 2016 Resolved
In void #2 the watertight bulkhead at frame 11 was found wasted with an 1/2 inch diameter hole at the bottom of the bulkhead in way of the center vertical keel. Approximately a 26 inch x 18 inch insert to the bulkhead is required to be installed and completion of non-destructive testing shall be completed in the presence of an marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder installed an 26 inch x 18 inch insert with aluminum 5000 series plate. Welds were tested satisfactorily with an soap and air test.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 18 March 2016 Resolved
In void #2 fractured welds were discovered at starboard longitudinal #3, #4, & #5 in way of frame 11. Fractured welds were also discovered at the port longitudinal #4 in way of frame 11.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder gouged and re-welded fractured welds.
Construction/Loadline › Hull › Bracket
Issued 18 March 2016 Resolved
Three gussets in void #2 that attach the port transverse frames to the starboard transverse frames were found excessively deteriorated. Replace identified three gussets to original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Replaced three gassets, completed visual inspection of welds.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2016 Resolved
Portside transverse frames #5 and #6 in void #2 where found fractured. Replace framing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Transverse frames were cropped and renewed.
Construction/Loadline › Hull › Transverse Frame
Issued 18 March 2016 Resolved
Crop and renew starboard transverse frame #5 where welds are fractured.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Crop and Renewed frame #5.
Construction/Loadline › Hull › Longitudinal Frame
Issued 18 March 2016 Resolved
Identified the overhead deck longitudinal framing at both the port and starboard #7 frames. Replace approximately 3ft section of each frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Replaced overhead framing members. Visually inspected welds.
Construction/Loadline › Hull › Weld
Issued 18 March 2016 Resolved
Identified fractured weld at the connection between the stanchion and the floor frame.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 30 March 2016
Resolution: Shipyard welder gouged and rewelded.
Engineering › Steering Gear System › Linkage
Issued 16 March 2016 Resolved
Starboard rudder was found with significant movement. The ball joints connecting the jockey bar to the rudder stock was found to be worn and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 8 April 2016
Resolution: Shipyard replaced jockey bar, replaced bearings and steering system tested satisfactory.

Casualty record · 7

20 December 2005Routine · role: Involved in a Marine Casualty · activity 2555733
11 June 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6710822
30 August 2019Routine · role: Involved in a Marine Casualty · activity 6850145
13 August 2020Routine · role: Involved in a Marine Casualty · activity 7049419
24 September 2020Routine · role: Involved in a Marine Casualty · activity 7069499
28 August 2021Routine · role: Involved in a Marine Casualty · activity 7307204
2 June 2022Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7600514
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CAROLINA PRINCESS (2005–2022). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.