MAURY USCG vessel records
← All vessels

LIKI TIKI

LIKI TIKI is a 1971 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in July 2026, along with 32 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 7 July 2026.

Built
1971
Last inspected
7 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 July 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WSN3511
273017
Flag
UNITED STATES
Maury page id
psix-273017

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 32 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

7 July 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8431547
10 June 2025 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8166243
6 May 2025 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8129517
6 June 2024 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7929515
18 April 2023 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7675524
12 May 2022 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7448898
25 January 2022 Drydock Exam · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7385470
17 May 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7202668
22 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6965599
6 June 2019 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6705884
17 October 2018 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6562931
25 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6220426
5 June 2017 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6163202
18 January 2017 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6072844
18 November 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6044011
13 July 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5939717

Deficiency record · 32

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025 Resolved
Fuel Line from tank to engine is deteriorated; Hose must meet requirements of 46CFR 182.720(e)(SAE J-1942)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2025
Resolved 19 June 2025
Resolution: Hose replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 May 2025 Resolved
Pontoon "nose cones" were found to be damaged; demonstrate successful pressure test (2psi) to prove watertight integrity to the attending Marine Inspector
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2025
Resolved 1 July 2025
Resolution: Inspection/test ports added; leaks repaired
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 May 2025 Resolved
Means of performing mandatory post SMI alcohol testing could not be demonstrated; alcohol swabs not onboard or available. Demonstrate ability to meet testing requirements (have alcohol testing swabs readily avail)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2025
Resolved 13 May 2025
Resolution: Received Alcohol Strips
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 June 2024 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel owner stated the outboard engine required a new lower unit. Replace in kind to the satisfaction of the attending MI. 46 CFR 182.05-1 Old T
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2024
Resolved 27 June 2024
Resolution: Cleared.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 April 2023 Resolved
Fire extinguishers have not been serviced in more than one year. Have all fire extiguishers servicing updated.
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 24 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 April 2023 Resolved
Required visual distress signals are expired.
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 24 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 April 2023 Resolved
Light for ring buoy is extinguished.
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 24 April 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 April 2023 Resolved
Marking for fuel shut-off has been removed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 24 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 April 2023 Resolved
Crew training has not been completed within three months.
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 24 April 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2021 Resolved
Revise emergency instructions to suit route and service.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 May 2021 Resolved
Prove proper operation of waterlight prior to operating at night.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 17 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 May 2021 Resolved
Renew fuel hoses with USCG fuel A or B hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2021
Resolved 25 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 May 2020 Resolved
Provide two VDS prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2020
Resolved 22 May 2020
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 May 2020 Resolved
Provide one fire bucket with lanyard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2020
Resolved 22 May 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 Resolved
Install hex nuts on battery terminals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2020
Resolved 22 May 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2020 Resolved
Remove flammable liquids from vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2020
Resolved 22 May 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 June 2019 Resolved
Provide 19 type 1 PFD's.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 June 2019
Resolved 19 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2019 Resolved
Remove wire nuts and housedold wiring. Replace with permanent connectors and marine grade 14 AWG wire.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 19 June 2019
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 6 June 2019 Resolved
Properly label switches on the console.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 19 June 2019
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2019 Resolved
Prove proper operation of the stern light. Vessel restricted to daylight operations until satisfied.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 19 June 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 June 2019 Resolved
Place fire extinguishers in approved brackets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 19 June 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2019 Resolved
Provide means for auxiliary steering.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2019
Resolved 19 June 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 October 2018 Resolved
Renew retro reflective material on 18 life jackets
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 October 2018
Resolved 2 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 17 October 2018 Resolved
Ring Bouy Light was not working; Renew battery or replace. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 October 2018
Resolved 2 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 October 2018 Resolved
Renew wasted fuel line from the fuel shut off valve to the outboard engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 2 November 2018
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 17 October 2018 Resolved
Renew Marpol Placard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 2 November 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 October 2018 Resolved
Provide Company Drug and Alcohol Program and Employee assistance Program.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 2 November 2018
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 17 October 2018 Resolved
Renew Hand Bilge Pump
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 2 November 2018
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 17 October 2018 Resolved
Have onboard chart of operating areas and inland navigation rules.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 2 November 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 17 October 2018 Resolved
Label Fuel Shutoff Valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 October 2018
Resolved 2 November 2018
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 June 2017 Resolved
Remove wire nuts, remove dead end wire and install marine grade boat cable to inverter.
Condition: Placed in Improper Service
Due 5 July 2017
Resolved 25 July 2017
Construction/Loadline › Hull › Hull Plating
Issued 18 November 2016 Resolved
Crop and renew damaged section of starboard pontoon, aft chamber and air test repairs.
Action required: 705 - Other - as specified
Due 31 January 2017
Resolved 18 January 2017
Resolution: Cleared

Ownership record