← All vessels
NEW UTOPIA
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Oceania District (CGD-O) · Other hulls named NEW UTOPIA
NEW UTOPIA is a 1974 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 1987, most recently in March 2025, along with 143 deficiencies — 9 with no resolution recorded — and 1 operational control.
Records from 1987 to 2025. Most recent: inspection, 9 March 2025.
- Built
- 1974
- Last inspected
- 9 March 2025
- Documentation
- Invalid · documentation file of 10 September 2026
- Deficiencies
- 143 recorded · 9 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
114354
7394802 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
7MEW
273226
Flag
SOUTH KOREA
—
Maury page id
psix-273226
Inspections, by type
…with no type recorded22
…past their stated due date9
Years with a record
9 calendar years (1987–2025)
The 24 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)513.5 ft × 68.9 ft × 28.9 ft
Registered tonnagegross 12,344 / net 7,089
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · ONOMMICHI, JAPAN · built 1974
Hull materialNot recorded
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsNot recorded
DocumentationInvalid
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1853 - Dead Weight, Ton
12344 - Regulatory (Subpart C or D), Gross Ton
7089 - Regulatory (Subpart C or D), Net Ton
12344 - Regulatory (Subpart C or D), Gross Ton
7089 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 24
9 March 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8090750
27 March 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 142983
27 March 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 415295
27 March 1998
Quarterly Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 791274
22 January 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 675325
10 January 1998
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 413208
31 December 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 411458
27 March 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 402029
31 January 1997
Control Verification
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 775530
10 January 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 399939
1 January 1997
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 399249
31 December 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 386393
31 December 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 876552
1 January 1995
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 374095
10 January 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 363909
10 January 1994
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1162459
24 February 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 675326
9 February 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 356169
30 December 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 348060
11 January 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 514356
31 December 1988
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 327627
3 August 1988
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 324847
1 May 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015462
30 March 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015461
Deficiency record · 143
Electrical
Issued 27 March 1998
No resolution recorded
While visually inspecting the engineroom, it was observed that several light fixtures were missing the protective covers. Specific Cite: SOLAS 74 amended CH.I/Reg.11_x001C_ _x001C_
Fire Fighting
Issued 27 March 1998
No resolution recorded
While conducting a visual inspection of the ro/ro space (used for trash collection), it was observed that 3 of the portable fire extinguishers wereblocked by debris. (Port side aft, landing by old customs room, and stbd side forward of containers). Specific Cite: SOLAS 74 amended CH.II-2/Reg.21
Fire Fighting
Issued 27 March 1998
No resolution recorded
While visually inspecting the ro/ro space (used for trash collection), it was observed that the fire hose in the station located port side is not compatable with the fire hydrant. Specifc Cite: SOLAS 74 amended CH.II- 2/Reg.21_x001C_
Lifesaving
Issued 27 March 1998
No resolution recorded
While conducting the abandon ship drill, the crew in the #2 lifeboat failedto keep the lifeboat of the reef. Boat drifted until it grounded and holedmaking the boat unusable. Specific Cite: SOLAS 74 amended CH.I/Reg.11._x001C_ _x001C_
Lifesaving
Issued 27 March 1998
No resolution recorded
While conducting the abandon ship drill, it was observed that the port sideembarkation ladders were incorrecly installed; e.g. they were turned 180 degrees when deployed. Specific Cite: SOLAS 74 amended CH.III/Reg.11
Lifesaving
Issued 27 March 1998
No resolution recorded
While conducting the abandon ship drill, it was observed that the ropes andthimbles for the embarkation ladders were worn and wasted. SOLAS 74 amended CH.I/Reg.11.
Construction/Loadline
Issued 27 March 1998
No resolution recorded
While conducting a deck walk, it was observed that the vent closure handle retaining pin for the vent located between # and #8 lifeboats was not in place. Specifc Cite: SOLAS 74 amended CH.I/Reg.11._x001C_ _x001C_
Lifesaving
Issued 27 March 1998
No resolution recorded
While conducting the abandon ship drill, the crew's proficiency in rigging the sail was not demonstrated. Specific Cite: Solas 74 amended CH.III/Reg.18._x001C_ _x001C_
Construction/Loadline
Issued 27 March 1998
No resolution recorded
While conducting a deck walk, it was observed that the #1 emergency watertight door is not adjusted to ensure full design closure. Specific Cite: SOLAS 74 amended CH.I/Reg.11._x001C_ _x001C_
Lifesaving
Issued 27 March 1998
Resolved
While visually inspecting the engineroom and other spaces, it was observed that the emergency escape for the shaft room was blocked with the fresh water transfer hose impeding escape route if needed. Specific Cite: SOLAS74 amended CH.I/Reg.11._x001C_
Lifesaving
Issued 10 January 1998
Resolved
#11 lifeboat sea valve was frozen (seized) in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat dipper is not rustproof as required by SOLAS 60 III.
Lifesaving
Issued 10 January 1998
Resolved
#11 lifeboat alternator beld loose.
Lifesaving
Issued 10 January 1998
Resolved
Passenger galley overheads, ventilation ducting, and other surfaces are covered with grease. Presence of grease creates unacceptable risk of fire.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat oil lamp is not operable in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat mast pulley is frozen in place in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat compass light is not operable in non-adherence with SOLAS 74 (amended) III/19.
Fire Fighting
Issued 10 January 1998
Resolved
Double hinge style glass doors at aft entrance to #4 deck "Brass Room" under some conditions prevent proper closure of fire screen doors located immediately forward of them. Condition of concern exists when glass doors are opened towards "Brass Room."
Fire Fighting
Issued 10 January 1998
Resolved
Lifeline immediately attached to fireman's harness is not fire-proof and isin non-adherence with SOLAS 60 II/63.
Construction/Loadline
Issued 10 January 1998
Resolved
Portside forward door leading to weatherdeck in the "Brass Room" could not be opened in non-adherence with SOLAS 74 (amended) I/11.
Construction/Loadline
Issued 10 January 1998
Resolved
Ventilation ducting in galley is holed and wasted in non-adherence with SOLAS 74 (amended) I/11. Temporary repairs consisting of paper and cloth shall be removed and permanent repairs made not later than 01MAR98.
Electrical
Issued 10 January 1998
Resolved
Electrical installations not safe: e.g. missing light covers/guards in crewmess, aft steering, roro space, deck 4 passageway; electrical outlet in crew mess is not shielded; electrical wiring for NOHMI CO2 Fire Exting- uishing System in CO2 room is pulled away from connection. SOLAS 60 II/23
Lifesaving
Issued 10 January 1998
Resolved
#5 lifeboat mast pulley is frozen in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#3 lifeboat jackknife lanyard is missing in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#3 lifeboat forward slinghook mounting bolt is wasted and in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat aft boat seat fasteners are wasted in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat forward and aft sling hook vertical bracket mounting plates aredeteriorated in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat athwartships bench mast support bracket swivil pin is deteriorated in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#3 lifeboat mast pulley pin is deteriorated and in non-adherence with SOLAS74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat water intake line inboard of the sea valve deteriorated and not permanently attached in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#11 lifeboat cooling water suction line between sea valve and engine was deteriorated and in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat fire extinguisher not recently serviced thereby raising doubtsas to fitness for service and adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat forward sling hook bracket deteriorated in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat forward port side seating not fastened in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#2 Lifeboat aft sling hook upper support bracket fasteners deteriorated in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#4 lifeboat missing boat hook in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#4 lifeboat mast pulley frozen in place in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#6 lifeboat oil lamp not operational in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#6 lifeboat mast pulley frozen in place in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#6 lifeboat wire stay shackles requires require replacement due to deterioration. Deteriorated condition is in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#6 Lifeboat compass illumination does not work in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#5 lifeboat aft slinghook position plate boltes deteriorated in non- adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat mast pulley frozen in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat dipper lanyard is missing in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat jackknife lanyard is missing in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat starboard forward floorboards are deteriorated in non-adherencewith SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat mast support board fasteners are deteriorated in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat forward sling hook position plate bolt wasted in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat aft slinghook position plate bolts are deteriorated in non- adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat aft seat does not fit in mounting slot in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat fasteners for 4th seat from the stern are deteriorated in non- adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#7 lifeboat forward seat does not fit mounting slot in non-adherence with SOLAS 74 (amended) III?19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#9 lifeboat jackknife missing lanyard in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#9 lifeboat mast bottom foundation housing floorboard fasteners deteriorated in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#9 lifeboat floorboards, floorboard fasters, and other wooden appurtenancesdeteriorated in non-compliance with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#11 lifeboat foundation for alternator to radio batteries wasted in non- adherence with SOLAS 60 III/14(e).
Lifesaving
Issued 10 January 1998
Resolved
#9 lifeboat aft slinghook position plate bolts deteriorated in non- adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#11 lifeboat jackknife lanyard missing in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#5 lifeboat compass illumination is not operable and in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#5 lifeboat jackknife lanyard is missing in non-adherence with SOLAS 74 (amended) and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#5 lifeboat forward slinghook position plate boltes are wasted in non- adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#6 lifeboat jackknife has no lanyard in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#8 lifeboat mast pulley frozen in place in non-adherence to SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#8 lifeboat wire stay shackles require replacement due to deterioration. Deteriorated condition is in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#8 lifeboat jackknife is missing a lanyard in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#8 lifeboat aft sling hook bracket and fasteners are deteriorated in non- adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat mast pulley frozen in place in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat missing wire stays in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat is missing sail in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat electric torch is not waterproof in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat jackknife is missing a lanyard in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat mast lower retaining bracket floor board requires securing to come into compliance with SOLAS 74 III/19.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat forward sling hook upper bracket requires renewal due to deterioration. Deteriorated condition is in non-adherence with SOLAS 74 III/19.
Lifesaving
Issued 10 January 1998
Resolved
#10 lifeboat aft sling hook bracket requires renewal due to deterioration. Deteriorated condition is in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat torch case is not waterproof in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat electric torch is damaged and not fit for intended service in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat jackknife is missing lanyard in non-adherence to SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat missing searchlight in non-adherence with SOLAS 60 III/14.
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat engine cover deteriorated and in non-adherence with SOLAS 60 III/9._x001C_
Lifesaving
Issued 10 January 1998
Resolved
#12 lifeboat shaft bearing creates high pitched squeel during operation raising concerns of improper shaft allignment, improper bearing, or other unknown problem in non-adherence with SOLAS 74 (amended) III/19. Vessel required to examine & take corrective action prior to 01FEB98.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat oil lamp is not operable due to a frozen wich adjusting mechanism in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat mast pulley frozen in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat dipper lanyard is missing in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat jackknife lanyard is missing in non-adherence with SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat fore and aft position plate sfor hooks and attachment bolts wasted in non-adherence with SOLAS 74 (amended) III/19 and SOLAS 60 III/11.
Lifesaving
Issued 10 January 1998
Resolved
#1 lifeboat wood floorboards are rotted in non-adherence with SOLAS 74 (amended) III/19.
Lifesaving
Issued 10 January 1998
Resolved
#2 lifeboat jackknife does not have lanyard in non-adherence with SOLAS 60 III/11.
Documentation
Issued 31 December 1997
Resolved
Provide Criterion Numeral required by SOLAS 60 II.5(c).
Fire Fighting
Issued 31 December 1997
Resolved
Many fire doors in staircases do not completely close when automatically released, in non-adherence with SOLAS 74 (amended) II-2/30. Unsat doors identified on New Utopia cabin plan left with vessels Capt. and one copy atMSO Guam.
Fire Fighting
Issued 31 December 1997
Resolved
No fixed fire extingushing system within the duct in the passenger galley, in non-adherence with SOLAS 74 (amended) II-2/41-2.4.3.
Fire Fighting
Issued 31 December 1997
Resolved
No mechanical ventilation (exhaust) installed in CO2 cylinder room in non- adherence with SOLAS 74 (amended) II-2/5.1.13.
Lifesaving
Issued 31 December 1997
Resolved
Lifeboat No. 11, missing 1 plug, oars rotten, rations compartment leaks around opening, engine compartment cover wasted, in non-adherence with_x001C_ SOLAS 60 III/II-a&d, III/3-c.
Lifesaving
Issued 31 December 1997
Resolved
Lifeboat No. 5 missing 1 drain plug in non-adherence with SOLAS 60 III/11-a&d, III/3-c
Lifesaving
Issued 31 December 1997
Resolved
Life boat No. 6 upper mast step rotten/loose, manropes frayed, in non- adhrence with SOLAS 60 III/11-a&d, III/3-c.
Lifesaving
Issued 31 December 1997
Resolved
Lifeboat No. 9, sail equipment missing in non-adherence with SOLAS 60 III/II-a&d, III/3-c.
Lifesaving
Issued 31 December 1997
Resolved
Lifeboat No. 10, upper mast step loose/rotten, rudder retaining pin wasted,in non-adherence with SOLAS 60 III/II-a&d, III/3-c.
Fire Fighting
Issued 31 December 1997
Resolved
Fixed CO2 cylinder room is located 3 decks below open deck in non- adherence with SOLAS 74 (amended) II-2/5.1.13.
Lifesaving
Issued 31 December 1997
Resolved
Most lifeboats, Tillers and rudders wasted or inoperable, bilge pump hoses inoperable/rotten in nnon-adherence with SOLAS 60 III/11-a(xxii).
Lifesaving
Issued 31 December 1997
Resolved
Life boat davit brake No. 10 broke during drill. Restore to good working order to meet requirements of SOLAS 60 III/36-f.
Lifesaving
Issued 31 December 1997
Resolved
Lifeboat No. 9, mast bracket rotten/loose, repair as per SOLAS 60 III/11- a&d, III/3-c.
Accommodation/Occupational Safety
Issued 31 December 1997
Resolved
Passenger galley range duct not fitted with cleaning access hatches in non-adherence with SOLAS 74 (amended) II-2/41-2.4.3.
Fire Fighting
Issued 31 December 1997
Resolved
CO2 cylinder room is not gas tight between room and steering flat in non- adherence with SOLAS 74 (amended) II-2/5.1.13.
Fire Fighting
Issued 31 December 1997
Resolved
Conduct fire drill to satisfaction of attending Marine Inspector as required by SOLAS 74 (amended) I/19.
Fire Fighting
Issued 31 December 1997
Resolved
Vessel plans to allow for Port State confirmation that vessel fully complies with the 1992 Fire Safety Amendments to SOLAS 1974 not submitted to the U.S. Coast Guard Marine Safety Center for examination.
Lifesaving
Issued 31 December 1997
Resolved
Liferaft launch operational instructions not complete as required by SOLAS 74 (amended) III/9.2 in that the instructions do not mention release of side pins, a critical step in launching the raft.
Lifesaving
Issued 31 December 1997
Resolved
Lifeboat no. 1 ration storage watertight container wasted, in non-adherencewith SOLAS 60 III/11-a,d and III/3-c.
Lifesaving
Issued 31 December 1997
Resolved
Life boat No. 2 upper mast step wasted, rudder retaining pin wasted, and_x001C_ rudder post brackets wasted, in non-adherence with SOLAS 60 III/11-a&d, III/3-c
Lifesaving
Issued 31 December 1997
Resolved
Life Boat No. 3, protective covering torn, upper mast step rotten/separatedfrom boat, floor boards rotten/missing, seating rotten/not secured, in non-adherence with SOLAS 60 III/11-a&d, III/3-c.
Lifesaving
Issued 31 December 1997
Resolved
Life boat No. 4 seats loose/Rotten in non-adherence with SOLAS 60 III/11- a&d, III/3-c
Fire Fighting
Issued 31 December 1997
Resolved
No self-closing fire screen doors that are capable of release from a central control station and from a position at the door are located at crew's galley boundaries, as required by SOLAS 74 (amended) II-2/41-2.4.1.
Accommodation/Occupational Safety
Issued 31 December 1997
Resolved
Galley range ducts not fitted with a damper at the lower end of the duct, means to secure exhaust fan(s) within the galley, (both crew and passenger galleys), as required by SOLAS 74 (amended) II-2/41-2.4.3.
Construction/Loadline
Issued 31 December 1997
Resolved
Loadline not painted in color contrasting to hull as required by ICLL 66 ANNEX 1 Chapter 1, Reg. 5.
Fire Fighting
Issued 31 December 1997
Resolved
Doctor's cabin on deck 5F opens directly into stairwell in non-adherence with SOLAS 74 (amended) II-2/41-2.4.5
Navigation
Issued 31 December 1997
Resolved
Chart corrections not up to date, as per 33CFR164.33(a)(1)(ii).
Navigation
Issued 31 December 1997
Resolved
Light list not corrected as required by SOLAS 74 (amended) V/20 and 33 CFR 164.33.
Fire Fighting
Issued 31 December 1997
Resolved
Fire control plan does not indicate information required by SOLAS 74 (amended) 41-2.1.1
Fire Fighting
Issued 31 December 1997
Resolved
Laundry spaces have direct access to stairway enclosures, in non-adherence with SOLAS 74 (amended) II-2/41-2.4.4.
Lifesaving
Issued 31 December 1997
Resolved
Missing low location lighting for door handle to starlight room exit, required by SOLAS 74 (amended) II-2/41-2.4.7.
Unknown
Issued 10 January 1997
Resolved
Fire control plan was written only in Japanese language. _x001C_ SOLAS 74 amended II-2/20.1
Unknown
Issued 10 January 1997
Resolved
Manual and automatic fire doors do not close and seal properly._x001C_ SOLAS 60 II/38
Fire Fighting
Issued 1 January 1997
Resolved
The handles on two portable fire extinguisher doors were missing and one door was painted over as to inhibit its access. Specific Site: SOLAS 60, II/66._x001C_ _x001C_
Electrical
Issued 1 January 1997
Resolved
Sveral electrical switchboard rooms were cluttered with miscellaneous itemsas to restrict access into space. Specific Site: SOLAS 60, II/27(a)(ii)._x001C_ _x001C_ _x001C_
Electrical
Issued 1 January 1997
Resolved
Throughout the vessel, guards were missing from electric lights. Specific Site: SOLAS 60, Reg II/27(a)(v)._x001C_ _x001C_ _x001C_
Lifesaving
Issued 1 January 1997
Resolved
Vessel has not performed the firefighting or abandon ship drills on a weekly basis. Vessel is required to adequately demonstrate both drills in next U.S. port, vessel was scheduled to return to Guam on 10JAN97. Master was cautioned to insure there was time for the drills.
Fire Fighting
Issued 1 January 1997
Resolved
Numerous fire boundry doors were secured open with hooks, ropes, lines. _x001C_ Specific Site: SOLAS 60. Reg. II-42, Reg II/39(a)._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 1 January 1997
Resolved
It was noted that the fire fighting drills and abandon ship drill were not being conducted weekly or logged. Specific Site: SOLAS 60, Reg III/26(a)(i).
Lifesaving
Issued 1 January 1997
Resolved
The vessel was missing two lifebouys with lights and selfactivating smoke capable of quick release from the bridge as required. Specific Site: SOLAS60 Reg III/21(g).
Documentation
Issued 10 January 1994
Resolved
OIL TRANSFER PROCEDURES WERE MISSING A DESCRIPTION OF THE PRODUCTS ROUTINELY TRANSFERED. PROVIDED VESSEL'S CHEIF ENGINEER WITH CARGO INFORMATION CARDS FOR THE PRODUCTS ROUTINELY TRANSFERED.
Documentation
Issued 9 February 1993
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE; MISSING LIST OF PRODUCTS TRANSFERRED BY VSL, DESCRIPTION OF EACH TRANSFER SYSTEM, PROCEDURES FOR EMPTYING MANIFOLDS, MEANS OF COMMUNICATIONS, TOPPING OFF TANKS, ENSURING VALVES ARE CLOSED, REPORTING OIL SPILLS.
Navigation
Issued 3 August 1988
Resolved
33CFR164.33(A)(1)(II) A VESSEL OF 1600 GROSS TONS OR MORE OPERATING IN THE NAVIGABLE WATERS OF THE U.S. SHALL HAVE A CURRENTLY CORRECTED CHART OF THE AREA TO BE TRANSITED.
Navigation
Issued 3 August 1988
Resolved
3CFR164.35(G)(7) A VESSEL OF 1600 GT OR MORE OPERATING IN THE NAVIGABLE WATERS OF THE U.S. SHALL HAVE A WARNING STATEMENT ON IT'S MANEUVERING FACT SHEET.
Construction/Loadline
Issued 30 March 1987
Resolved
ENSURE GASKETS ARE IN PLACE ON PORT AND STARBOARD GOOSENECK VENTS TO BO- SWAIN'S STOREROOM.
Construction/Loadline
Issued 30 March 1987
Resolved
STRAIGHTEN VENT CAP TO NO. 12 FOT ON STARBOARD SIDE OF "C" DECK.
Construction/Loadline
Issued 30 March 1987
Resolved
REPLACE AIR VENT PIPE TO BOILER ROOM ON THE PORT SIDE OF "C" DECK.
Construction/Loadline
Issued 30 March 1987
Resolved
REPLACE GASKET ON WATERTIGHT DOOR TO AFTER STEERING.
Construction/Loadline
Issued 30 March 1987
Resolved
ENSURE PROPER SEAL OF PAINT LOCKER WATERTIGHT DOOR.
Construction/Loadline
Issued 30 March 1987
Resolved
RE-GASKET 3 VENTS IN WAY OF PAINT LOCKER ON STERN SECTION.
Construction/Loadline
Issued 30 March 1987
Resolved
STERN SECTION, PORT AND STARBOARD GOOSENECK VENTS NEED GASKETS.
Construction/Loadline
Issued 30 March 1987
Resolved
STERN SECTION, STARBOARD SIDE, AFT, HATCH COVER TO TRUNK ACCESS NEEDS REPAIR OR REPLACEMENT FOR PROPER SEAL.
Construction/Loadline
Issued 30 March 1987
Resolved
REPAIR DOUBLE DOOR GAKET ON "B" DECK STARBOARD SIDE FORWARD.
Construction/Loadline
Issued 30 March 1987
Resolved
INSTALL WATERTIGHT CLOSURES ON "B" DECK STARBOARD SIDE AIR DUCTS.
Construction/Loadline
Issued 30 March 1987
Resolved
REPLACE WATERTIGHT DOOR ON PORT SIDE OF FORECASTLE LEADING TO BOSWAIN'S LOCKER.
Construction/Loadline
Issued 30 March 1987
Resolved
RENEW GASKET AND PROPERLY SEAL HATCH ON ESCAPE HATCH (CENTERLINE, FOC'SLE) FROM BOSWAIN'S LOCKER.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.