AQUASTAR

AQUASTAR is a 2001 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 2016, most recently in March 2026, along with 17 deficiencies and 1 casualty investigation in 2004.

Records from 2004 to 2026. Most recent: inspection, 3 March 2026.

Built
2001
Last inspected
3 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2328
Flag
UNITED STATES
Maury page id
psix-27343

Documentation record

Registered dimensions (L × B × D)57.0 ft × 17.7 ft × 7.0 ft
Registered tonnagegross 47 / net 37
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGILLMAN MARINE INC · PANAMA CITY, FL, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 10 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it37 - Simplified, Net Ton
47 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

3 March 2026 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8306177
21 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8129825
23 April 2025 Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 8128968
18 February 2025 Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8080707
17 May 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7914208
7 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7822256
25 May 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7695704
28 February 2023 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7634793
18 January 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7629801
25 August 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7653651
1 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7452314
25 September 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7333608
9 March 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7139405
13 January 2021 Hull Examination · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7123858
14 May 2020 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6953661
30 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814310
29 March 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6652171
28 February 2019 Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6620144
31 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498223
30 January 2018 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6346214
2 August 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6230097
22 June 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6183914
17 May 2017 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6148656
19 January 2017 Administrative Inspection · Examination of Repairs · Plan Review "T" Boat · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6073702
24 March 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5840538
18 February 2016 COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5817819

Deficiency record · 17

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 March 2026 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. ...The registration card must request the owner's name, address, telephone number, type of ship, alternate emergency contact and other information as required by NOAA. The registration card must also contain information regarding the availability to register the EPIRB at NOAA's online web-based registration database... MI observed vessel's EPIRB registration does not have the correct call sign. 46 CFR 184.502 and 47 CFR 80.1061
Action required: 10 - Deficiency Rectified
Resolved 6 March 2026
Resolution: Updated EPIRB registration, corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 May 2024 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The Boyant Appartus lifeline was found degraded. Recommended replacing lifeline.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2024
Resolved 11 July 2024
Resolution: Vessel Rep provided proof via photograph of replaced lifeline. Determined to be satisfactory. Uploaded into Documents tab.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 June 2023 Resolved
Owner/Operator shall heed stability constraints until provided with original stability letter or letter is located: Operation is permitted on Exposed waters. However, you are cautioned that the route and conditions of operation may be further limited as specified on the Certificate of Inspection. A maximum of twenty one (21) persons may be carried on board the vessel of which nineteen (19) may be passengers. Since the total number of persons allowed is based on other considerations in addition to stability, you are cautioned that the number of persons may be further limited as specified on the Certificate of Inspection. No permanent ballast or other such weights shall be added, removed, altered and/or relocated without the authorization and supervision of the cognizant OCMI. The vessel is not fitted with permanent ballast. No watertight bulkheads shall be removed or altered without the authorization and supervision of the cognizant OCMI. No windshields, curtains, canvases, or other wind blocking devices shall be installed on the vessel. Any openings that could allow water to enter into the hull should be kept closed when rough weather or sea conditions exist or are anticipated. The vessel's bilge and voids shall be kept at a minimum content at all times consistent with pollution prevention requirements. You should make every effort to determine the cause of any list of the vessel before taking corrective action. In accordance with 46 CFR 185.315, after loading and prior to departure, the master shall determine that the vessel complies with all applicable stability requirements. The vessel may not depart until it is in compliance with the requirements specified in this letter. It shall be the operator's responsibility to maintain the vessel in a satisfactory stability condition at all times.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 October 2023
Resolution: This office will leave the original letter as is, applicable but unsigned.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 May 2023 Resolved
Vessel must have stern light. Stern light not working. Repair and provide proof of working stern light. Added additional 14 days due to email not sending.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 June 2023
Resolved 25 October 2023
Resolution: Stern light operable.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2021 Resolved
Battery charger was missing drip guard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2021
Resolved 17 March 2021
Resolution: A drip guard has been installed over the battery charger.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 March 2021 Resolved
Lifebuoy painter weak link missing certification tag.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2021
Resolved 17 March 2021
Resolution: Life buoy weak link was replace with a new weak link which included required certification tag.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 8 May 2019 Resolved
01 Secure MSD overboard discharge valve with lock.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 21 May 2019
Resolution: Installed a lock
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2019 Resolved
02 Hardwire freezer and remove cable from engineroom outlet. Outlet must remain covered.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 21 May 2019
Resolution: Installed a gfi outlet and enclosed it in an in-use weather tight outlet
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 July 2018 Resolved
NLT 29OCT18 Vessel shall provide a special consideration request to allow PVC piping in bilge system or remove all rigid non-metallic piping in the bilge system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 October 2018
Resolved 28 February 2019
Resolution: PVC replaced with non rigid hose
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 May 2017 Resolved
High water light does not work for forward berthing bilge. Replace IAW 46 CFR 182.530.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 22 June 2017
Resolution: High water light worked in fwd berthing bilge.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 May 2017 Resolved
Switch labels for fuel shut offs on stbd and generator valve, works but needs to be relabeled. 46 CFR 182.455.
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 May 2017
Resolution: Relabeled appropriately during inspection.
Documentation › Markings/Placards › Warning Signs
Issued 18 May 2017 Resolved
Mount emergency broadcast placard at the operating station IAW 46 CFR 184.506
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2017
Resolved 18 May 2017
Resolution: Re-stenciled placard for legibility.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 May 2017 Resolved
Install fire detection sensor in galley area IAW 46 CFR 177.410
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 2 August 2017
Resolution: Installed and tested, all SAT.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 18 May 2017 Resolved
Purchase ladder to help with the recovery of helpless persons from the water IAW 46 CFR 185.512 and 176.800
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 22 June 2017
Resolution: Ladder purchased and stowed.
Deck/Cargo › Ballast › Piping
Issued 10 May 2017 Resolved
Submersible bilge pump system has been installed incorrect. Bilge system will be installed IAW 46cfr182.520 (e) and 182.710
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 31 July 2018
Resolution: Cleared deficiency and subsequently reissued IAW SECMOB OCMI guidance regarding PVC Piping in Bilge Systems
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 March 2016 Resolved
Smoke detectors are incorrect type. Ensure smoke detectors are UL 217 approved IAW 46 CFR, 177.410(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 24 March 2016
Resolution: Installed correct smoke detectors.
Communications › Radio Communications › VHF Radiotelephone
Issued 3 March 2016 Resolved
VHF radio not equipped with DSC function. Ensure vessel has DSC-equipped VHF radio IAW 46 CFR, 184.502.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 April 2016
Resolved 24 March 2016
Resolution: Installed correct VHF radio.

Casualty record · 1

19 June 2004Routine · role: Involved in a Marine Casualty · activity 2113927
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.