Records from 2000 to 2001. Most recent: inspection, 5 April 2001.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering
Issued 5 April 2001
Resolved
PROVE ENGINE ALARMS FOR #1 AND #2 GENERATORS.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Lifesaving
Issued 5 April 2001
Resolved
REPLACE WIND SOCK ON HELO DECK.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Lifesaving
Issued 5 April 2001
Resolved
PROVIDE PROOF OF EQUIPMENT INVENTORY INCLUDING WATER AND RATIONS FOR LIFEBOAT #3.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Lifesaving
Issued 5 April 2001
Resolved
PROVIDE PROOF OF WATER AND RATIONS COUNT FOR PORT BOAT.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Documentation
Issued 5 April 2001
No resolution recorded
PROVIDE ABS APPROVAL OF CURRENT FIRE AND SAFETY PLANS.
Condition: Unknown
Due 5 May 2001 — due date passed with no resolution recorded
Lifesaving
Issued 5 April 2001
Resolved
PROVIDE DOCUMENTATION FOR PERMANENT #2 LIFERAFT WHEN ONBOARD PERMANENTLY.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Deck/Cargo
Issued 5 April 2001
Resolved
RELOCATE STARBOARD CRANE CONTROL BOX OUTSIDE CLASS 1 DIV 2 AREA OR PROVIDE PROPER CONTROL BOX.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Fire Fighting
Issued 5 April 2001
Resolved
PROPERLY LOCATE AND LABEL ALL CO2 OPERATING STATIONS FOR MACHINERY SPACE, EMERGENCY GENERATOR AND PAINT LOCKER.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Lifesaving
Issued 5 April 2001
Resolved
PROVIDE 50 EA RATIONS FOR ALL 3 LIFE BOATS.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Electrical
Issued 5 April 2001
Resolved
PROVIDE SAFETY CABLES FOR LIGHT FIXTURES IN PIT ROOM.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001
Fire Fighting
Issued 5 April 2001
No resolution recorded
PROVIDE FOAM ANALYSIS.
Condition: Unknown
Due 5 May 2001 — due date passed with no resolution recorded
Deck/Cargo
Issued 5 April 2001
No resolution recorded
PROVIDE PROOF OF NEGATIVE VENTILATION IN THE MUD PIT ROOM. IN ADDITION, AN ALARM MUST SOUND IN ACCORDANCE WITH IMO MODU CODE 89 6.4.1 AND 46 CFR 108.185.
Condition: Unknown
Due 5 May 2001 — due date passed with no resolution recorded
Electrical
Issued 5 April 2001
Resolved
PROVIDE APPROPRIATE LIGHT FIXTURES IN THE DRILLERS CONSOLE. MUST BE ZONE 1 APPROVED. (CLASS 1 DIV 1).
Condition: Unknown
Due 5 April 2001
Resolved 12 July 2001
Construction/Loadline
Issued 5 April 2001
Resolved
REMOVE ALL SILICONE AND REPLACE WITH PROPER ROCKS BLOCK ALL PENETRATIONS ONVESSEL WHERE H2S MONITORING AND CASCADE SYSTEM WAS INSTALLED.
Condition: Unknown
Due 9 April 2001
Resolved 12 July 2001