Records from 1986 to 2010. Most recent: inspection, 17 August 2010.
Inspection history · 43
17 August 2010
COC-TVE Renew · ISPS III Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3827879
21 August 2009
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3578355
21 August 2009
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3584516
7 August 2009
COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3583988
29 September 2008
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3334882
26 August 2008
ISPS II Exam · COC-TVE Annual
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3316874
1 August 2007
COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3021032
8 August 2006
COC-TVE Annual
Administrative · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 2740274
3 August 2005
COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2450128
29 July 2004
ISPS II Exam · COC-TVE Annual
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2168613
13 May 2004
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2078893
30 October 2003
Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1939307
27 August 2003
Deficiency Check
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1888745
21 July 2003
Re-Inspection · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 1849422
17 July 2002
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1647259
23 July 2001
Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1644507
8 July 2000
Tank Vessel Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1379124
8 July 1999
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 430621
26 June 1998
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1127201
20 June 1997
Tank Vessel Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1378094
12 June 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 394387
12 June 1996
Tank Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360551
30 May 1996
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1086257
27 June 1995
Tank Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 844438
27 June 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 881002
27 June 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1086253
27 June 1995
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1414490
16 February 1995
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 843732
15 November 1994
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1380103
11 July 1994
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 865385
15 July 1993
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1377011
22 April 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 948795
24 June 1991
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1218622
17 June 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1042428
17 June 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1350563
3 May 1990
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 922979
13 December 1989
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1240414
21 March 1989
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1032268
16 March 1989
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1204653
28 November 1988
Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1344553
21 June 1988
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1208395
14 August 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1337335
21 August 1986
COI Inspection · Credit Drydock
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1007458
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 29 July 2004
Resolved
Pressure Vaccum Relief valves not fitted with 30 x 30 inch mesh flame screens.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 August 2005
Resolution: Installed 30 x 30 mesh flame screen on Pressure Vacuum Relief valves.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 July 2004
Resolved
Install guard over engine alternator pulley
Action required: 15 - Rectify deficiencies by next port
Resolved 2 August 2005
Resolution: Guard installed over engine alternator pulley.
Documentation › Markings/Placards › Warning Signs
Issued 29 July 2004
Resolved
Post warning sign to be visible from both sides of vessel.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 August 2005
Resolution: Warning signs posted both sides of vessel.
Documentation › Certificates/Documents
Issued 21 July 2003
Resolved
Provide on board barge original IOPP certificate. Received faxed copy of new cert issued July 11, 2003. However cert not on board vessel as required by MARPOL 73/78 therefore requirement stands. LEGACY COMPONENT DESC: IOPP Certificate
Due 21 August 2003
Resolved 27 August 2003
Resolution: Original onboard. KPB
Pollution Prevention/Response › Prevention Equipment
Issued 21 July 2003
Resolved
Prove proper operation of pump engine shut down, 2 switches. LEGACY COMPONENT DESC: Cargo Monitor/Control System
Due 21 August 2003
Resolved 27 August 2003
Resolution: Log entries and proof of hydro test provided. KPB
Documentation › Logs/Records
Issued 21 July 2003
Resolved
Provide proof of required servicing/test of fuel oil piping. LEGACY COMPONENT DESC: Transfer Equipment Test/Inspection Records
Due 21 August 2003
Resolved 27 August 2003
Resolution: Log entries and proof of hydro test provided. KPB
Engineering › Fuel Oil Service System
Issued 21 July 2003
Resolved
Remove excessive standing oil and hydraulic fluid from deck of engine compartment and repair leaks as appropriate.
Due 21 August 2003
Resolved 27 August 2003
Resolution: Area cleaned and being maintained IAW regulations and safe working practices. KPB
Electrical › Electrical Distribution System (service)
Issued 21 July 2003
Resolved
Provide blanks IWO engine compartment switch board (3 holes) LEGACY COMPONENT DESC: Distribution Panel Bus
Due 21 August 2003
Resolved 27 August 2003
Resolution: Blanks inserted satisfactory condition provided. KPB
Electrical › Electrical Distribution System (service)
Issued 21 July 2003
Resolved
Remove dead ended wires IWO engine space. (Several locations). Also remove and properly secure wires IWO engines having wire nut attached. Found 1 missing leaving exposed wires. (7 wire nuts applied) LEGACY COMPONENT DESC: Wiring
Due 21 August 2003
Resolved 27 August 2003
Resolution: Wire nuts removed and proper connection made. KPB
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 July 2003
Resolved
Repair P/V manual handles and ensure operational test completed as required by your op manual. LEGACY COMPONENT DESC: Pressure/Vacuum Relief Valve
Due 21 August 2003
Resolved 29 October 2003
Resolution: New handles manufactured and installed during dockside period Sep/Oct 03, rcvd mail attesting to same. KPB
Fire Fighting › Fire Pumps
Issued 21 July 2003
Resolved
Repair leaking fire pump seals. LEGACY COMPONENT DESC: Gland Sealing
Due 21 August 2003
Resolved 29 October 2003
Resolution: Fire pump replaced during dockside period Sep/Oct 03, rcvd mail attesting to same. KPB
Electrical › Electrical Distribution System (service)
Issued 21 July 2003
Resolved
Repair ground fault found IWO distribution boxes in engine compartment. (Engine block heaters & hot water heater). LEGACY COMPONENT DESC: Wiring
Due 21 August 2003
Resolved 27 August 2003
Resolution: Wire repairs completed with satisfactory results. KPB
Deck/Cargo
Issued 12 June 1996
Resolved
The prime mover emergency shutdown for the cargo pumps is inoperative. Thisdiscrepency is to be completed to the satisfaction of an attending flag state surveyor prior to entering United States waters.
Condition: Unknown
Due 24 June 1996
Resolved 24 June 1996
Documentation
Issued 15 November 1994
Resolved
OBTAIN IOPP CERTIFICATE PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Unknown
Issued 22 April 1992
Resolved
OPEN PRESSURE VESSEL FOR INTERNAL INSPECTION PRIOR TO PLACING IN SERVICE OR30 APR 92 WHICH EVER SHOULD OCCUR FIRST._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1992
Resolved 29 April 1992
Deck/Cargo
Issued 22 April 1992
Resolved
CONDUCT SATISFACTORY HYDROSTATIC TEST OF CARGO PIPING IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PRIOR TO DEPARTURE FROM POINT WELLS, WA AFTER LOADING NEXT CARGO OR 30 APR 92 WHICH EVER SHOULD OCCUR FIRST._x001C_ _x001C_
Condition: Unknown
Due 30 April 1992
Resolved 29 April 1992
Fire Fighting
Issued 17 June 1991
Resolved
PROVIDE SERVICING REPORT FOR HALON AND DETECTING SYSTEMS.
Condition: Unknown
Due 17 June 1991
Resolved 17 June 1991
Deck/Cargo
Issued 21 June 1988
Resolved
INSTALL HYDRAULIC RELIEF VALVE IN THE HYDRAULIC OIL COOLER SYSTEM, SET TO RELIEVE AT OR BELOW 3 BAR.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Unknown
Issued 21 June 1988
Resolved
INSTALL 4 REACH RODS THRU THE DECK FOR THE AFT PEAK TANKS.
Condition: Unknown
Due 21 June 1988