RELIANCE is a 1986 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1986, most recently in November 2025, along with 92 deficiencies, 2 operational controls and 6 casualty investigations between 2006 and 2024.

Records from 1986 to 2025. Most recent: inspection, 12 November 2025.

Built
1986
Last inspected
12 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCY7809
274659
Flag
UNITED STATES
367384130
Maury page id
psix-274659

Inspections, by type

…with no type recorded7
Years with a record 32 calendar years (1986–2025)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 12.5 ft × 4.2 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS · CAPE CANAVERAL FL · built 1986
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST CROIX, VI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 26 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCY7809MMSI 367384130 · active · compulsorily equipped · granted 13 September 2018, expires 25 November 2028
WCW6023MMSI not assigned · expired · voluntarily equipped · granted 21 May 1996, cancelled 22 July 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

12 November 2025 DAPI Audit · Deficiency Check · COI Inspection · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8261702
29 January 2025 Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8067300
27 August 2024 Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7992707
3 June 2024 Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7926076
22 April 2024 In-Service Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7899926
19 April 2024 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7904427
6 February 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7861354
15 December 2022 Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7604309
23 August 2022 Deficiency Check · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7540402
14 February 2022 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7396031
1 February 2022 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7388056
27 January 2022 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7384465
12 November 2020 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7090119
21 August 2020 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7038042
9 July 2020 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7001383
19 June 2020 Administrative Inspection · Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6980871
4 February 2020 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6901462
8 July 2019 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6734818
3 July 2019 Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6734723
18 October 2018 Examination of Repairs · Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6570953
26 April 2018 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6399826
4 April 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6117509
28 October 2016 In-Service Inspection · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6296226
12 January 2016 COI Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5801889
15 August 2015 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5220222
1 October 2014 Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4997642
2 February 2012 Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4236770
14 September 2011 Drydock Exam · Internal Structural Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4148899
27 January 2011 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3933758
10 March 2010 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3702124
3 March 2010 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3689034
3 April 2009 Internal Structural Exam · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3444962
25 March 2008 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3170454
24 September 2007 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3035712
11 July 2007 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3015426
15 March 2007 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3166415
23 October 2006 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2806534
24 February 2006 COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2591339
30 September 2005 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2301659
2 May 2005 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2345218
20 April 2004 Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2049145
26 September 2003 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1917130
30 April 2003 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1783713
6 May 2002 Hull Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1613585
11 April 2002 Re-Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1604037
30 March 2001 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1068167
27 March 2001 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1455979
10 January 2001 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1469332
9 July 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1051786
25 May 2000 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 818306
24 May 2000 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1468142
5 October 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1044547
17 June 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 863002
27 April 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 793390
27 April 1999 Plan Review "T" Boat
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1126004
23 April 1999 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444134
16 December 1998 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 808639
4 November 1998 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 808482
29 October 1998 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 803627
29 September 1998 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1444065
31 March 1998 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1416680
11 March 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1377965
3 June 1996 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1084164
21 September 1995 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879887
1 May 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 865736
31 March 1995 Hull Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 837036
24 February 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1143383
8 December 1989 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1222476
17 November 1988 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1205395
31 May 1988 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1194452
23 October 1987 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1325924
7 February 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1028948
10 October 1986 Initial Certification · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1327947

Deficiency record · 92

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025 Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. The panel in the v-berth is not totally enclosed as a cover is missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 8 December 2025
Resolution: The opening in the distribution panel has been covered.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 November 2025 Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. An excessive amount of oil was noted in the bilge spaces.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2025
Resolution: The excessive oil has been cleaned up and removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wiring was noted under the operating station console.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 23 January 2026
Resolution: Satisfactorily inspected the wiring under the operating station console.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 November 2025 Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The alcohol test strips maintained on board the vessel are not DOT-approved.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 22 January 2026
Resolution: Newly-acquired alcohol test strips are now maintained at the Christiansted office for this vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 November 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 8 December 2025
Resolution: John provided his marine radio operator permit.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 January 2025 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. The vessel crew could not prove compass illumination.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 26 February 2025
Resolution: The vessel will no longer conduct night dives and no longer needs a compass that illuminates.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 January 2025 Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. The vessel's Communications Act Safety Radiotelephony Certificate could not be produced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 11 March 2025
Resolution: Vessel operator provided the re-issued FCC Radiotelephony Certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 August 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Fractured railing on top deck effecting strength of railings and forward on stbd side. Repair. 46 CFR 177.900 (b)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Railings repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 August 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Numerous dead end wires found in engine compartment and steering compartment. Clean up wiring. 46 CFR 183.200 (c)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Dead end wires cleaned up.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 August 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High level float switch not secured in fwd compartment. Secure. 46 CFR 182.530(a)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Float switch secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2024 Resolved
Machinery and fuel tank spaces must be separated by boundaries that prevent the passage of vapors. The lazarette has a penetration to the engineroom that is not vapor tight. Provide a proper seal to prevent the passage of vapors. 46 CFR 177.405
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Bulkhead sealed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 August 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Two through hull penetrations in fuel tank compartment are no longer being used. Plug/cap valves to prevent the ingress of water into space. 46 CFR 177.405
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Valves were plugged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 April 2024 Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil shall be provided for all propulsion engines and located so as to be in view of the operator. Repair gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2024
Resolved 3 June 2024
Resolution: New gauges have been installed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 6 February 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, must be indicated by a durable marking of at least 1 inch at the entrance way to that deck. Vessel is missing placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 6 March 2024
Resolution: Placard has been added to vessel for crew only.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2024 Resolved
A vessel must comply with the applicable requirements to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a crew member with a valid FCC operators license. Lance needs his FCC operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 12 March 2024
Resolution: [name withheld] has completed his FCC operators course.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2024 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel missing training log book.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 6 March 2024
Resolution: Drill logged has been placed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 December 2022 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Vessel is missing placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 19 December 2022
Resolution: Placard has been placed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 December 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard light list. Vessel missing light list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 19 December 2022
Resolution: Updated charts and light lists have been placed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 15 December 2022 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, must be indicated by a durable marking of at least 1 inch at the entrance way to that deck. Vessel is missing placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 19 December 2022
Resolution: Crew only placard has been placed on ladder heading to topside helm station.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 15 December 2022 Resolved
U.S. vessels that transport more than 6 passengers for hire shall pass an inspection by an FCC licensed tech., in accordance with 80.59 once every 5 years. If the ship passes an inspection tech. will issue a Communications act safety radio telephony certificate. Vessel does not have safety radio certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2023
Resolved 7 February 2023
Resolution: Received photo documentation of the FCC safety cert.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 27 January 2022 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing actions to be taken in the event of fire, heavy weather or man over board conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2022
Resolved 1 February 2022
Resolution: Emergency placard has been placed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2022 Resolved
On a vessel of at least 26ft. in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. AFT bilge alarm does not work.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2022
Resolved 1 February 2022
Resolution: New bilge pump has been installed and tested. Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2020 Resolved
MDE fuel shut-off was INOP.
Action required: 10 - Deficiency Rectified
Due 12 November 2020
Resolved 12 November 2020
Resolution: Repaired the same day. It was rusty, cleand and operated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2020 Resolved
Broken O-Ring in the hydraulic resevoir causing a loss of hydraulic fluid in the steering system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Replaced O-Ring. Tested steering system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 February 2020 Resolved
Provide current certificate of documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 10 February 2020
Resolution: Vessel received new COD.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 February 2020 Resolved
Lazarette bilge high water alarm inop. Vessel required to complete rounds every hour while underway.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 11 February 2020
Resolution: Vessel wired alarm into engine room high water alarm to provide some alerting ability until parts came in. New alarm installed and operational 11FEB2020.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 4 February 2020 Resolved
VHF-FM radio could not transmit when tested. Restricted vessel to 1000ft of dock until correctly working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2020
Resolved 5 February 2020
Resolution: Vessel repaired radio and transmit/receive was verified before the vessel carried passengers.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 February 2020 Resolved
Provide working horn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 5 February 2020
Resolution: Air horn provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2020 Resolved
Replace wiring underneath bridge controls that has dead ends and twist on type connectors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 11 February 2020
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2020 Resolved
Replace (01) one PFD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 11 February 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 July 2019 Resolved
Vessel engine room bilge high level alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 9 July 2019
Resolution: Fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2019 Resolved
Vessels lifebuoy and lifeline require replacing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 9 July 2019
Resolution: Replaced with new ring buoy and lifeline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 July 2019 Resolved
Vessels emergency fuel shut off did not shut off engine after ten minutes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 31 July 2019
Resolution: Witnessed emergency fuel shut down operation. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 July 2019 Resolved
Items in vessels first aid kit have expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 24 July 2019
Resolution: Items replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 July 2019 Resolved
Out of compliance with annual inspection
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2019
Resolution: Inspection completed
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 4 April 2017 Resolved
Grounding strap is not securely fatened. (missing nut)
Condition: Improper Installation
Due 4 April 2017
Resolved 4 April 2017
Resolution: Grounding strap securely fastened.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 April 2017 Resolved
Stern light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2017
Resolution: Repalaced and proved proper operation of stern light.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 April 2017 Resolved
Emergency ventilation for engine room inoperable. Starboard side does not shut all the way. Portside lanyard/pull cord broke.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Resolution: Proved proper operation of both port and starboard emergency ventilation shutdowns.
Communications › Alarms/Indicators › High Water Alarm
Issued 4 April 2017 Resolved
Fwd compartment high water alarm inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Resolution: Proved proper operation of high water alarm for fwd compartment.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 January 2016 Resolved
Make forward bilge alarm operational.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: Forward bilge alarm operational.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 3 March 2010 Resolved
Provide proof or servicing for system.
Due 17 March 2010
Resolved 17 March 2010
Resolution: Received notification from master that servicing was completed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 March 2010 Resolved
Provide audible alarm for fixed fire system.
Due 17 March 2010
Resolved 4 May 2010
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 March 2010 Resolved
Provide bonding wire between fuel tank and fuel fill pipe.
Due 17 March 2010
Resolved 17 March 2010
Resolution: Received notification from master that wire was installed.
Engineering › Fuel Oil Service System › Filter
Issued 3 March 2010 Resolved
Provide flame shield for RACOR fuel filter.
Due 17 March 2010
Resolved 27 April 2010
Engineering › Bilge Water Management System › Hose
Issued 3 March 2010 Resolved
Provide positive shut-off valves at through hull fittings from bilge dishchargee lines.
Due 17 March 2010
Resolved 27 April 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 April 2009 Resolved
Provide evidence of Random Drug testing for crew.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 April 2009
Resolved 3 April 2009
Resolution: Corrected.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 April 2009 Resolved
Provide missing flashlight.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 2 October 2009
Resolution: Cleared all Sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2009 Resolved
Refill first aid kit.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 2 October 2009
Resolution: Cleared all sat.
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 3 April 2009 Resolved
Provide onboard missing chart.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 2 October 2009
Resolution: Cleared all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 3 April 2009 Resolved
Provide missing fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 April 2009
Resolution: Replaced.
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 April 2009 Resolved
Provide new compass with light onboard.
Action required: 705 - Other - as specified
Due 10 April 2009
Resolved 2 October 2009
Resolution: Cleared all sat.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 25 March 2008 Resolved
Remove anchor from steering room. the anchor is rubbing and cutting into the hull. Remove the anchor within 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: Relocated anchor.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 March 2008 Resolved
Electrical board back panel is missing causing electrical cables to be left exposed. Make permanent repairs within 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: Installed new cover.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 March 2008 Resolved
Label electric panel to correspond with switches. make repairs within 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: Labeled panel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 March 2008 Resolved
Provide bracket for Dry Chemical fire extinguisher. Make repairs in 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: New bracket.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 25 March 2008 Resolved
connect fire boy pull pin and cable. replace with the correct cable to operational condition within 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: Installed correct cable.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 March 2008 Resolved
Pain reliever medication in the first aid kit was expired. replace with current bottle within 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: Replaced medication.
Engineering › Fuel Oil Service System › Filter
Issued 25 March 2008 Resolved
Provide bowl for Raycor fuel filter. Make repairs within 14 days to the satisfaction of the Coast Guard.
Action required: 705 - Other - as specified
Due 8 April 2008
Resolved 7 May 2008
Resolution: Installed racor bowl.
Engineering
Issued 6 May 2002 Resolved
Renew engine mounts
Condition: Improper/Lack of Maintenance
Due 6 June 2002
Resolved 6 May 2002
Engineering
Issued 6 May 2002 Resolved
Renew cooling salt water hoses
Due 6 June 2002
Resolved 6 May 2002
Engineering
Issued 6 May 2002 Resolved
Make repairs to fiberglass muffler where cracked.
Due 6 June 2002
Resolved 6 May 2002
Construction/Loadline › Hull
Issued 11 April 2002 Resolved
Make hatches watertight.
Due 11 May 2002
Resolved 11 April 2002
Documentation
Issued 27 March 2001 Resolved
COMPLETE DRILLS TO THE SATISFACTION OF THE ATTENDING CG INSPECTOR.
Condition: Unknown
Due 27 March 2001
Resolved 27 March 2001
Engineering
Issued 24 May 2000 Resolved
Provide handle for fuel shut off valve.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Navigation
Issued 24 May 2000 Resolved
Make proper repairs to navigation lights. Vessel is restricted to daylightoperations until corrected.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Lifesaving
Issued 24 May 2000 Resolved
Make proper repairs to the life float lifeline webbing strap.
Condition: Unknown
Due 24 May 2000
Resolved 24 May 2000
Lifesaving
Issued 31 March 1998 Resolved
Replace line on life ring buoy
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Electrical
Issued 31 March 1998 Resolved
Remove dead ended wires from the operating station
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Lifesaving
Issued 31 March 1998 Resolved
Replace retroreflective tape and lines on life float
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Construction/Loadline
Issued 31 March 1998 Resolved
On all four main deck hatches, provide water tight gasket.
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Lifesaving
Issued 31 March 1998 Resolved
Install retroreflective tape on life ring bouy
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Navigation
Issued 31 March 1998 Resolved
Make horn operable
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Construction/Loadline
Issued 31 March 1998 Resolved
On forward three main deck hatches, provide retention wire.
Condition: Unknown
Due 30 September 1998
Resolved 30 September 1998
Navigation
Issued 31 March 1998 Resolved
Make operational navigation lights_x001C_ Port, Starboard, and anchor
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Construction/Loadline
Issued 31 March 1998 Resolved
On main engine hatch, provide hatch securing device.
Condition: Unknown
Due 31 March 1998
Resolved 31 March 1998
Engineering
Issued 3 June 1996 Resolved
Renew the 1 1/2 inch diameter rubber hose between the seastrainer and the main diesel engine's rew water pump. 46 CFR Part 182.20-10.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 3 June 1996 Resolved
Provide and post emergency instructions in accordance with 46 CFR Part 185.25-1.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Documentation
Issued 3 June 1996 Resolved
Prior to placing vessel back in service, submit written proof of a chemicaltesting program which complies with 46 CFR Part 16 to USCG Resident Inspection Office for review.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Documentation
Issued 3 June 1996 Resolved
Post the vessel's stability letter in accordance with 46 CFR Part 185.12-1 prior to vessel departure.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Navigation
Issued 3 June 1996 Resolved
Renew aluminum flat bar which the steel rudder post passes through (stabilizer bar) due to severe wastage caused by stray electical current. 46 CFR Part 182.30-1.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Construction/Loadline
Issued 3 June 1996 Resolved
Scrape away all furry wood in the engine compartment and treat same with a wood preservative.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 3 June 1996 Resolved
Make minor repairs to life float cover where split and torn.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 3 June 1996 Resolved
Restow life float's seapainter so it will not jam in the canister. 46 CFR Part 180.20.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Lifesaving
Issued 3 June 1996 Resolved
Mark the vessel's name on the required ring buoy in accordance with 46 CFR Part 185.30-5.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Fire Fighting
Issued 3 June 1996 Resolved
Provide a longer hose for the hand operated fire and bilge pump in accordance with 46 CFR Part 181.10-5.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Engineering
Issued 3 June 1996 Resolved
Renew the 8 inch diameter rubber exhaust hose approximately 30 inches in length between the maine diesel engine and the aft bulkhead in the engine compartment.
Condition: Unknown
Due 3 June 1996
Resolved 3 June 1996
Documentation
Issued 31 March 1995 Resolved
PROVIDE DOCUMENTATION OF A PREEMPLOYMENT, RANDOM AND POST CASUALTY CHEMICALTESTING PROGRAM IN ACCORDANCE WITH TITLE 46 C.F.R. PART 16.
Condition: Unknown
Due 31 March 1995
Resolved 31 March 1995
Documentation
Issued 31 March 1995 Resolved
PROVIDE DOCUMENTATION OF FCC STATION LICENSE.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 31 March 1995 Resolved
PROVIDE A COPY OF THE LAST SERVICE REPORT FOR ALL ON BOARD B-II PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Construction/Loadline
Issued 10 October 1986 Resolved
PROVIDE THE OFFICE COPY OF TEST SPECIMEN OF THE HULL, FLEXURAL, TENSILE, RESIN CONTENT AND LAY UP SEQUENCES.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Construction/Loadline
Issued 10 October 1986 Resolved
PROVE WATERTIGHTNESS OF ALL MAINDECK HATCHES PRIOR TO SAILING.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Documentation
Issued 10 October 1986 Resolved
PROVIDE PROPER FCC STATION LICENSE AND SAFETY RADIO TELEPHONEY CERTIFICATE.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986

Casualty record · 6

23 October 2006Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 injured · activity 2806534
11 July 2007Routine · role: Involved in a Marine Casualty · 1 injured · activity 3015426
10 March 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3702124
15 August 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5220222
9 July 2020Routine · role: Involved in a Marine Casualty · activity 7001383
19 April 2024Routine · role: Involved in a Marine Casualty · activity 7904427
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.