Records from 2006 to 2025. Most recent: inspection, 12 November 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 24
12 November 2025
DAPI Audit · Deficiency Check · COI Inspection · In-Service Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8261702
29 January 2025
Administrative Inspection · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8067300
27 August 2024
Drydock Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7992707
3 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7926076
22 April 2024
In-Service Inspection · Internal Structural Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7899926
19 April 2024
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7904427
6 February 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7861354
15 December 2022
Deficiency Check · Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7604309
23 August 2022
Deficiency Check · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7540402
14 February 2022
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7396031
1 February 2022
Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7388056
27 January 2022
Annual Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7384465
12 November 2020
COI Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7090119
21 August 2020
Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7038042
9 July 2020
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7001383
19 June 2020
Administrative Inspection · Damage Survey
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6980871
4 February 2020
Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6901462
8 July 2019
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6734818
3 July 2019
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6734723
18 October 2018
Examination of Repairs · Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6570953
26 April 2018
Annual Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6399826
4 April 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6117509
28 October 2016
In-Service Inspection · Drydock Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6296226
12 January 2016
COI Inspection · DAPI Audit
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 5801889
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 November 2025
Resolved
Each distribution panel or switchboard must be totally enclosed and of the dead front type. The panel in the v-berth is not totally enclosed as a cover is missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2025
Resolved 8 December 2025
Resolution: The opening in the distribution panel has been covered.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 November 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil that might create a fire hazard. An excessive amount of oil was noted in the bilge spaces.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2025
Resolution: The excessive oil has been cleaned up and removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wiring was noted under the operating station console.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 23 January 2026
Resolution: Satisfactorily inspected the wiring under the operating station console.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 12 November 2025
Resolved
A marine employer shall comply with the requirements of 46 CFR 4.06. The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in a Serious Marine Incident. The alcohol test strips maintained on board the vessel are not DOT-approved.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2025
Resolved 22 January 2026
Resolution: Newly-acquired alcohol test strips are now maintained at the Christiansted office for this vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 12 November 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 November 2025
Resolved 8 December 2025
Resolution: John provided his marine radio operator permit.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 January 2025
Resolved
Except on a vessel limited to daytime operations, the
compass must be illuminated. The vessel crew could not
prove compass illumination.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 26 February 2025
Resolution: The vessel will no longer conduct night dives and no longer needs a compass that illuminates.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 29 January 2025
Resolved
A vessel must comply with the applicable requirements for any radio installation, including the requirements for a station license and installation certificates to be issued by the FCC in 47 CFR Part 80. The vessel's Communications Act Safety Radiotelephony Certificate could not be produced.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2025
Resolved 11 March 2025
Resolution: Vessel operator provided the re-issued FCC Radiotelephony Certificate.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 August 2024
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Fractured railing on top deck effecting strength of railings and forward on stbd side. Repair.
46 CFR 177.900 (b)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Railings repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 August 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Numerous dead end wires found in engine compartment and steering compartment. Clean up wiring.
46 CFR 183.200 (c)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Dead end wires cleaned up.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 August 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High level float switch not secured in fwd compartment. Secure.
46 CFR 182.530(a)
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Float switch secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2024
Resolved
Machinery and fuel tank spaces must be separated by boundaries that prevent the passage of vapors. The lazarette has a penetration to the engineroom that is not vapor tight. Provide a proper seal to prevent the passage of vapors.
46 CFR 177.405
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Bulkhead sealed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 27 August 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Two through hull penetrations in fuel tank compartment are no longer being used. Plug/cap valves to prevent the ingress of water into space.
46 CFR 177.405
Action required: 705 - Other - as specified
Resolved 28 August 2024
Resolution: Valves were plugged.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 April 2024
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil shall be provided for all propulsion engines and located so as to be in view of the operator. Repair gauges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2024
Resolved 3 June 2024
Resolution: New gauges have been installed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 6 February 2024
Resolved
On a vessel on which the number of passengers
permitted on upper decks is limited by stability
criteria, must be indicated by a durable marking of at
least 1 inch at the entrance way to that deck. Vessel
is missing placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 6 March 2024
Resolution: Placard has been added to vessel for crew only.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2024
Resolved
A vessel must comply with the applicable requirements to be issued by the FCC as set forth in 47 CFR part 80. Vessel is required to have a crew member with a valid FCC operators license. Lance needs his FCC operators license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 12 March 2024
Resolution: [name withheld] has completed his FCC operators course.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2024
Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel missing training log book.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2024
Resolved 6 March 2024
Resolution: Drill logged has been placed on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 December 2022
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Vessel is missing placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 19 December 2022
Resolution: Placard has been placed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 December 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Guard light list. Vessel missing light list.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 19 December 2022
Resolution: Updated charts and light lists have been placed on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 15 December 2022
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, must be indicated by a durable marking of at least 1 inch at the entrance way to that deck. Vessel is missing placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2023
Resolved 19 December 2022
Resolution: Crew only placard has been placed on ladder heading to topside helm station.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 15 December 2022
Resolved
U.S. vessels that transport more than 6 passengers for hire shall pass an inspection by an FCC licensed tech., in accordance with 80.59 once every 5 years. If the ship passes an inspection tech. will issue a Communications act safety radio telephony certificate. Vessel does not have safety radio certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2023
Resolved 7 February 2023
Resolution: Received photo documentation of the FCC safety cert.
04 - Emergency Systems › N/A - No Subsystem › Damage control plan
Issued 27 January 2022
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing actions to be taken in the event of fire, heavy weather or man over board conditions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2022
Resolved 1 February 2022
Resolution: Emergency placard has been placed on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 January 2022
Resolved
On a vessel of at least 26ft. in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. AFT bilge alarm does not work.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2022
Resolved 1 February 2022
Resolution: New bilge pump has been installed and tested. Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 November 2020
Resolved
MDE fuel shut-off was INOP.
Action required: 10 - Deficiency Rectified
Due 12 November 2020
Resolved 12 November 2020
Resolution: Repaired the same day. It was rusty, cleand and operated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 June 2020
Resolved
Broken O-Ring in the hydraulic resevoir causing a loss of hydraulic fluid in the steering system.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 June 2020
Resolved 19 June 2020
Resolution: Replaced O-Ring. Tested steering system.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 February 2020
Resolved
Provide current certificate of documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 10 February 2020
Resolution: Vessel received new COD.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 February 2020
Resolved
Lazarette bilge high water alarm inop. Vessel required to complete rounds every hour while underway.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 11 February 2020
Resolution: Vessel wired alarm into engine room high water alarm to provide some alerting ability until parts came in. New alarm installed and operational 11FEB2020.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 4 February 2020
Resolved
VHF-FM radio could not transmit when tested. Restricted vessel to 1000ft of dock until correctly working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 March 2020
Resolved 5 February 2020
Resolution: Vessel repaired radio and transmit/receive was verified before the vessel carried passengers.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 February 2020
Resolved
Provide working horn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 5 February 2020
Resolution: Air horn provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 February 2020
Resolved
Replace wiring underneath bridge controls that has dead ends and twist on type connectors.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 11 February 2020
Resolution: Repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 February 2020
Resolved
Replace (01) one PFD.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 11 February 2020
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 July 2019
Resolved
Vessel engine room bilge high level alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2019
Resolved 9 July 2019
Resolution: Fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 July 2019
Resolved
Vessels lifebuoy and lifeline require replacing
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 9 July 2019
Resolution: Replaced with new ring buoy and lifeline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 July 2019
Resolved
Vessels emergency fuel shut off did not shut off engine after ten minutes.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 31 July 2019
Resolution: Witnessed emergency fuel shut down operation. All Sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 July 2019
Resolved
Items in vessels first aid kit have expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 24 July 2019
Resolution: Items replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 July 2019
Resolved
Out of compliance with annual inspection
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2019
Resolution: Inspection completed
Electrical › Electric Generation Source (service) › Neutral Ground
Issued 4 April 2017
Resolved
Grounding strap is not securely fatened. (missing nut)
Condition: Improper Installation
Due 4 April 2017
Resolved 4 April 2017
Resolution: Grounding strap securely fastened.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 April 2017
Resolved
Stern light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2017
Resolution: Repalaced and proved proper operation of stern light.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 April 2017
Resolved
Emergency ventilation for engine room inoperable. Starboard side does not shut all the way. Portside lanyard/pull cord broke.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Resolution: Proved proper operation of both port and starboard emergency ventilation shutdowns.
Communications › Alarms/Indicators › High Water Alarm
Issued 4 April 2017
Resolved
Fwd compartment high water alarm inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2017
Resolution: Proved proper operation of high water alarm for fwd compartment.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 January 2016
Resolved
Make forward bilge alarm operational.
Action required: 705 - Other - as specified
Due 12 February 2016
Resolved 25 January 2016
Resolution: Forward bilge alarm operational.